• 제목/요약/키워드: two-step cooling

검색결과 66건 처리시간 0.02초

물/PG-기반 $Al_2O_3$ 나노유체를 적용한 수냉식 CPU 쿨러의 냉각성능 (Cooling Performance of Liquid CPU Cooler using Water/PG-based $Al_2O_3$ Nanofluids)

  • 박용준;김규한;이승현;장석필
    • 한국분무공학회지
    • /
    • 제19권1호
    • /
    • pp.19-24
    • /
    • 2014
  • In this study, the cooling performance of a liquid CPU cooler using the water/propylene glycol(PG)-based $Al_2O_3$ nanofluids is experimentally investigated. Water/PG-based $Al_2O_3$ nanofluids are manufactured by two-step method with ultrasonic energy for 10 hours. The volume fractions of the nanofluids are 0.25% and 0.35%. Thermal conductivity and viscosity of the nanofluids are measured to theoretically predict the thermal performance of the liquid CPU cooler using performance factor. Performance factor results indicate that the cooling performance of the liquid CPU cooler can be improved using the manufactured nanofluids. To evaluate the cooling performance of the liquid CPU cooler experimentally, temperature differences between ambient air and heater are measured for base fluid and nanofluids respectively. Based on the results, it is shown that performance of the liquid CPU cooler using $Al_2O_3$ nanofluids is improved maximum up to 8.6% at 0.25 Vol.%.

ADI의 조직특성에 미치는 2단 오스테나이트화 처리조건의 영향 (Effect of Two Step Austenitizing Treatment Conditions on the Microstructural Characteristics of ADI)

  • 최석림;윤기혁;문원진;강창룡;김한군
    • 열처리공학회지
    • /
    • 제11권1호
    • /
    • pp.46-53
    • /
    • 1998
  • The variation of the mechanical properties, microstructures and the formation of retained austenite with heat treatment conditions in austempered ductile cast iron has been investigated. In the case of austempered ductile cast iron below 25mm diameter, it has been found that a pearlite structure are not obtained under a super cooled condition at range of $0.05^{\circ}C/sec{\sim}10^{\circ}C/sec$, and the matrix is precipitated in graphite, bainite and retained austenite. After austempering treatment the retained austenite is increased with decreasing cooling rate. The elongation increases with decreasing super cooling rate, and the optimum result has been shown to be the elongation of 15.6% at super cooling rate of $0.05^{\circ}C/sec$. The optimum result has been shown to be the tensile strength-elongation balance of $1656kgf/mm^2.%$ and it is more than doubled to as the casting state and continuous cooling condition.

  • PDF

생쥐배아의 동결보존에 관한 실험적 연구 (The Experimental Study on Cryopreservation of Mouse Embryo)

  • 이여일;권영숙;박현정
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제28권1호
    • /
    • pp.55-63
    • /
    • 2001
  • Objectives: This study was carried out to evaluate the effects of embryonic stage, cryoprotectant, and freezing-thawing method on the rates of survival and development of the cryopreserved mouse early embryo and finally to establish the cryopreservation method of surplus embryos obtained during assisted reproductive technology (ART). Materials and Methods: Two to eight cell embryos were obtained from oviducts of mated $F_1$ hybrid female mice superovulated by pregnant mare's serum gonadotropin (PMSG) and human chorionic gonadotropin (hCG). Two-step 1,2-propanediol (PROH), dimethylsulfoxide (DMSO) and 4-step PROH DMSO were used as cryoprotectant and dehydration and rehydration method of embryos, and slow-cooling or rapid-cooling method was used as frozen program. The survival rates of embryos were measured after thawing and rehydration, and the developmental rates of embryos were compared and observed during culturing embryos for 24, 48, 72, 96 hrs. Results: As for the survival and development rates of embryos according to embryonic stage, the survival rate of 2 cell stage in PROH and DMSO was significantly higher than 4-8 cell (64.5% versus 62.1 %,79.7% versus 73.2%) (p<0.01, p<0.01), but the development rates of 4-8 cell embryos in PROH and DMSO were significantly higher than 2 cell embryos for whole culture period (p<0.01) and the development rates of 4-8 cell embryos in PROH were significantly higher than 2 cell embryos in DMSO (p<0.01). As for the survival and development rates of embryos according to cryoprotectant, the survival rate of 2 cell embryo in DMSO was significantly higher than that in PROH (74.4% versus 64.5%) (p<0.01), whereas the development rate of embryos was not differ till 24 hrs. The developmen1 rate from morular to hatching blastocyst, however, was significantly higher in PROH than in DMSO during 48 hr (p<0.01). The survival rate of 4-8 cell embryo was 62.1% in PROH and 73.2% in DMSO. The development rates of embryo in PROH were significantly higher for whole culture periods (p<0.01, 0.05). In respect to the effect of freezing and thawing program on the survival and development rates of embryos, method of slow cooling and rapid thawing was more effective than that of rapid cooling and rapid thawing. Conclusions: The survival rate of embryo in 2 cell stage was higher than in 4-8 cell stage, and PROH appears more effective cryoprotectant than DMSO because PROH showed better development rates of embryos in 2 and 4-8 cell stage. Moreover, slow cooling and rapid thawing method was considered as the best cryopreservation program.

  • PDF

PWR 사용후핵연료 중간저장시설의 몬테칼로 차폐해석 방법에 대한 계산효율성 개선방안 연구 (Development for Improvement Methodology of Radiation Shielding Evaluation Efficiency about PWR SNF Interim Storage Facility)

  • 김태만;서명환;조천형;차길용;김순영
    • Journal of Radiation Protection and Research
    • /
    • 제40권2호
    • /
    • pp.92-100
    • /
    • 2015
  • 경수로 사용후핵연료 건식 중간저장시설의 방사선영향평가 효율성 개선을 목적으로 '선원항 지정방법에 따른 민감도 평가', '2-Step 계산'기법 개발 및 '냉각기간 이득효과' 적용에 따른 방사선 영향평가를 수행하였다. 본 연구에서는 저장건물의 용기배열 순서에 따라 순차적으로 선원항을 지정하여 직접선량에 미치는 민감도를 평가하였으며, 차폐건물 외벽에서의 방사선량은 내벽과 인접한 최근접 2개 열에 의한 영향이 지배적임을 확인하였다. 또한, 저장시설에 차폐 건물이 도입될 경우, 막대한 전산해석 시간을 감소시키기 위해 '2-Step 계산'기법을 수립하여 평가한 결과는 절반가량의 해석시간으로 직접(1-Step) 계산결과와 유사한 결과를 도출하였다. 마지막으로, 저장시설에 순차적으로 저장되는 저장용기의 보관기간을 사용후핵연료의 실제 냉각기간을 적용하면 건물 외벽에서의 방사선량이 냉각기간을 모두 동일하게 설정한 계산값에 비해 40% 정도 낮게 평가됨을 확인하였다. 본 연구는 중간저장시설의 방사선 영향평가를 위한 몬테칼로 차폐해석 방법의 효율성을 향상시키고자 수행되었으며, 좀 더 다양한 사례에 대한 평가를 통하여 신뢰성을 향상시킨다면 저장시설의 설계 및 부지경계 기준설정에 활용할 수 있을 것이다.

연속주조 몰드의 구조해석 (Structural Analysis of Continuous Casting Mold)

  • 원종진;이종선;홍석주
    • 한국공작기계학회논문집
    • /
    • 제10권4호
    • /
    • pp.104-110
    • /
    • 2001
  • The objective of this study is structural analysis of continuous casting mold. A two-dimensional finite element model was developed to compute the temperature distribution, thermal stress and thermal strain behavior for continuous casting mold. Structural analysis was made using thermal analysis result, utilizing transient analysis of ANSYS. This structural analysis results, many variables such as casting speed, cooling condition film coefficient, convection and load condition are considered.

  • PDF

이중외피시스템을 적용한 고층 주거용건물의 자연환기 성능평가 (A Study on Natural Ventilation Performance for a Double-Skin Facade System in Apartment Buildings)

  • 석호태;김동화;최정민
    • 한국주거학회논문집
    • /
    • 제14권3호
    • /
    • pp.119-126
    • /
    • 2003
  • The purpose of this study is to evaluate the natural ventilation performance for variable external wind speed as a preliminary step to determining the seasonal operating modes of the Double-skin Facade System applied to apartment buildings. For this purpose, two simulation programs are used to compare the Double-Skin Facade System with the Double Sash Window. First, TAS is used to plan a schedule for natural ventilation during the intermediate season and to analyze the cooling loads. Second, CFD is used for a more detailed airflow analysis on a typical floor plan of the model building. The results of the simulations on natural ventilation performance show that the Double-Skin Facade System can reduce the cooling load by 10.5% compared to the Double Sash Window.

암모니아/물 흡수식 냉동기의 수직원관형 흡수기의 동적 모델 (Dynamic Model of a Vertical Tube Absorber for Ammonia/water Absorption Refrigerators)

  • 문현석;정은수;김병주
    • 설비공학논문집
    • /
    • 제14권10호
    • /
    • pp.844-853
    • /
    • 2002
  • A dynamic model which simulates the coupled heat and mass transfer within a vertical tube absorber was developed. The liquid film is a binary mixture of two components, and both of these components are present in the vapor phase. The pressure, concentration, temperature and mass flow rate of the vapor are obtained by assuming that the pressure is uniform within an absorber. The model was applied to an absorber for an ammonia/water absorption refrigerator. The transient behaviors of the pressure, the outlet temperature and the concentration of the solution and the cooling water outlet temperature on a step change at the absorber inlet of the cooling water temperature, the vapor mass flow rate and the concentration of the solution were shown.

제한공간내 펄스가열에 기인한 열음향파의 전달특성에 관한 수치적 연구 (A Numerical Study on the Transmission of Thermo-Acoustic Wave Induced by Step Pulsed Heating in an Enclosure)

  • 황인주;김윤제
    • 설비공학논문집
    • /
    • 제14권11호
    • /
    • pp.914-922
    • /
    • 2002
  • Thermo-acoustic waves can be thermally generated in a compressible flow field by rapid heating and cooling, and chemical reaction near the boundary walls. This mechanism is very important in the space environment in which natural convection does not exist. Also this may be a significant factor for heat transfer when the fluids are close to the thermodynamic critical point. In this study, the generation and transmission characteristics of thermo-acoustic waves in an air-filled confined domain with two-step pulsed heating are studied numerically. The governing equations are discretized using control volume method, and are solved using PISO algorithm and second-order upwind scheme. For the purpose of stable solution, time step was set to the order of $1\times10_-9s,\;and\;grids\;are\;50\times2000$. Results show that temperature and pressure distributions of fluid near the boundary wall subjected to a rapid heating are increased abruptly, and the induced thermo-acoustic wave propagates through the fluid until it decays due to viscous and heat dissipation. Pressure waves have sharp front shape and decay with a long tail in the case of step heating, but these waves have sharp pin shape in the case of pulsed heating.

극저온 열처리 공정이 6061 알루미늄 합금의 잔류응력과 인장특성에 미치는 영향 (Effects of Cryogenic Treatment on Residual Stress and Tensile Properties for 6061 Al Alloy)

  • 박기정;고대훈;김병민;임학진;이정민;조영래
    • 대한금속재료학회지
    • /
    • 제49권1호
    • /
    • pp.9-16
    • /
    • 2011
  • To develop a 6061 aluminum alloy with low residual stress and high tensile strength, a cryogenic treatment process was investigated. Compared to the conventional heat treatment process for precipitation hardening with artificial aging, the cryogenic treatment process has two additional steps. The first step is cryogenic quenching of the sample into liquid nitrogen, the second step is up-hill quenching of the sample into boiling water. The residual stress for the sample was measured by the $sin^2{\psi}$ method with X-ray diffraction. The 6061 aluminum alloy sample showed 67% relief in stress at the cryogenic treatment process with artificial aging at $175^{\circ}C$. From this study, it was found that the optimum cryogenic treatment process for a sample with low residual stress and high tensile strength is relatively low cooling speed in the cryogenic quenching step and a very high heating speed in the up-hill quenching step.

Performance Analysis of an Inert Gas Generator for Fire Extinguishing

  • 김수용
    • 연구논문집
    • /
    • 통권29호
    • /
    • pp.5-15
    • /
    • 1999
  • Present study deals with performance analysis of an inert gas generator (IGG) which is to be used as an effective mean to suppress the fire. The IGG uses a turbo jet cycle gas turbine engine to generate inert gas for fire extinguishing. It is generally known that a lesser degree of oxygen content in the product of combustion will increase the effectiveness of fire suppressing. An inert gas generator system with water injection will bring advantages of suffocating and cooling effects which are considered as vital factors for fire extinguishing. As the inert gas is injected to the burning site, it lowers the oxygen content of the air surrounding the flame as well as reduces the temperature around the fire as the vapour in the inert gas evaporates during the time of spreading. Some important aspects of influencing parameters, such as, air excess coefficient. $\alpha$, compressor pressure ratio, $ pi_c$, air temperature before combustion chamber, $T_2$, gas temperature after combustion chamber, $T_3$, mass flow rate of water injection, $M_w$, etc., on the performance of IGG system are investigated. Calculations of total amount of water needed to reduce the turbine exit temperature to pre-set nozzle exit temperature employing a heat exchanger were made to compare the economics of the system. A heat exchanger with two step cooling by water and steam is considered to be better than water cooling only. Computer programs were developed to perform the cycle analysis of the IGG system and heat exchanger considered in the present study.

  • PDF