• Title/Summary/Keyword: two-point threshold

Search Result 122, Processing Time 0.027 seconds

Impact of Financial Instability on Economic Activity: Evidence from ASEAN Developing Countries

  • TRAN, Tra Thi Van
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.9 no.1
    • /
    • pp.177-187
    • /
    • 2022
  • Theoretical literature agrees on the interaction between financial instability and economic activity but explains it's dynamic in two points of view: one is that the transmission mechanism occurs in one unique regime and the other reckons a shift of regime leads to the alteration of the transmission mechanism. This study aims to find evidence of the multi-regime transmission for ASEAN developing countries. The author employs the technique of Threshold vector auto regression using the financial stress index standing for financial instability. Monthly data is collected, covering a period long enough with many episodes of high stress in recent decades. There are two conclusions: (1) A financial shock has a negative and stronger impact on economic activity during a high-stress period than it does during a low-stress period; (2) the response of economic activity to a negative financial shock during high-stress periods is stronger than it is during normal times. The findings point to the importance of the financial stress index as an additional early warning indicator for the real economy sector, as well as the positive effect that a reduction in financial stress may have on economic activity, implying the importance of "unconventional" monetary policy in times of high financial stress.

Implementation of point-of-care platforms for rapid detection of porcine circovirus type 2

  • Chiao-Hsu Ke;Mao-Yuan Du;Wang-Ju Hsieh;Chiu-Chiao Lin;James Mingjuh Ting;Ming-Tang Chiou;Chao-Nan Lin
    • Journal of Veterinary Science
    • /
    • v.25 no.2
    • /
    • pp.28.1-28.11
    • /
    • 2024
  • Background: Porcine circovirus type 2 (PCV2) infection is ubiquitous around the world. Diagnosis of the porcine circovirus-associated disease requires clinic-pathological elements together with the quantification of viral loads. Furthermore, given pig farms in regions lacking access to sufficient laboratory equipment, developing diagnostic devices with high accuracy, accessibility, and affordability is a necessity. Objectives: This study aims to investigate two newly developed diagnostic tools that may satisfy these criteria. Methods: We collected 250 specimens, including 170 PCV2-positive and 80 PCV2-negative samples. The standard diagnosis and cycle threshold (Ct) values were determined by quantitative polymerase chain reaction (qPCR). Then, two point-of-care (POC) diagnostic platforms, convective polymerase chain reaction (cPCR, qualitative assay: positive or negative results are shown) and EZtargex (quantitative assay: Ct values are shown), were examined and analyzed. Results: The sensitivity and specificity of cPCR were 88.23% and 100%, respectively; the sensitivity and specificity of EZtargex were 87.65% and 100%, respectively. These assays also showed excellent concordance compared with the qPCR assay (κ = 0.828 for cPCR and κ = 0.820 for EZtargex). The statistical analysis showed a great diagnostic power of the EZtargex assay to discriminate between samples with different levels of positivity. Conclusions: The two point-of-care diagnostic platforms are accurate, rapid, convenient and require little training for PCV2 diagnosis. These POC platforms can discriminate viral loads to predict the clinical status of the animals. The current study provided evidence that these diagnostics were applicable with high sensitivity and specificity in the diagnosis of PCV2 infection in the field.

The Effect of Applying Various Tools to the Stiffness and Muscle Tone of Hamstring Muscles (다양한 도구의 적용이 뒤넙다리근의 뻣뻣함과 근 긴장도에 미치는 영향)

  • Hwang, Sunghyun;Kim, Taeho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.223-230
    • /
    • 2020
  • Purpose : The purpose of this study was to examine the effects of tools (i., extracorporeal shock wave therapy, massage gun, and foam roller) on range of motion, muscle tone and pain threshold among patients with hamstring stiffness. Methods : Fourteen participants with hamstrings stiffness were recruited. Interventions were performed 6 times, and each session was for 30 seconds using the three tools. The range of motion, muscle tone, and pain threshold were measured. The order of the use of the three tools was randomly determined. The foam roller was made to move from the bottom of the hip crease to the upper part of the back of the hamstring. Additionally, velocity 5 vibration stimulation was performed on the hamstring using a massage gun. Moreover, vibration stimulation was performed on the hamstring with extracorporeal shock wave therapy 5 minutes, 5 Hz, and 1,500 strokes. The flexibility of the posterior thigh muscle was based on maintaining the knee and hip joints in a 90 ° bend in the supine position. The joint angle of the knee was measured, when the knee was actively extended, at the maximum point where the posterior thigh muscle was stretched. The elasticity of the posterior thigh muscle was measured while the subject was prone and in a relaxed state without any force. Measurements were made at the muscle abdominal area of the semitendinosus muscle of the posterior femur, and the area to be measured was marked with a pen. The measurement of the tenderness threshold of the posterior femur was measured using a tenderness meter(Commander Algometer, J-Tech, USA). The force value at the point at which the pressure sensation change to pain was measured after applying vertical pressure to the posterior femur muscle, which was the halfway point between the ischial tuberosity and the popliteal surface of the subject lying on their stomach. Results : The extracorporeal shock wave therapy increased stiffness and, muscle tone, and caused changes in the pain threshold, whereas the other two tools had no effect on these indices. Conclusion : Extracorporeal shock wave therapy has important effects on range of motion and muscle stiffness and can be used in warmup protocols.

Algorithm Development and Experimental Verification of Acoustic Emission First-arrival-time Determination for the Source Location (정확한 미소파괴음의 발생위치 분석을 위한 신호 도달시간 결정 알고리즘 연구 및 실험적 검증)

  • Jang, Hyun-Sic;Choi, Jun-Young;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.25 no.4
    • /
    • pp.587-598
    • /
    • 2015
  • We examined various existing threshold methods for the determination of the first arrival time of acoustic emission (AE), and developed a new variable threshold method that could determine the first arrival time of AE more accurately and more quickly than existing methods. The new method, a modification of an existing threshold method, does not fix the threshold, but applies variable thresholds for the AE signals according to noise analysis. Two- and three-dimensional models were established to test the effectiveness of the new method. It could determine source locations of AE in a two-dimensional model 38.3% more accurately than the pre-existing threshold methods. Its accuracy improvement over the existing methods in a three-dimensional model was about 15.2%. A practical test involved measuring the source locations of AE during three-point bending tests of granite cores. The new method placed the sources closer to the fracture plane than did the pre-existing methods, indicating its superior (and quicker) ability to determine the source locations of AE.

Crowd escape event detection based on Direction-Collectiveness Model

  • Wang, Mengdi;Chang, Faliang;Zhang, Youmei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.9
    • /
    • pp.4355-4374
    • /
    • 2018
  • Crowd escape event detection has become one of the hottest problems in intelligent surveillance filed. When the 'escape event' occurs, pedestrians will escape in a disordered way with different velocities and directions. Based on these characteristics, this paper proposes a Direction-Collectiveness Model to detect escape event in crowd scenes. First, we extract a set of trajectories from video sequences by using generalized Kanade-Lucas-Tomasi key point tracker (gKLT). Second, a Direction-Collectiveness Model is built based on the randomness of velocity and orientation calculated from the trajectories to express the movement of the crowd. This model can describe the movement of the crowd adequately. To obtain a generalized crowd escape event detector, we adopt an adaptive threshold according to the Direction-Collectiveness index. Experiments conducted on two widely used datasets demonstrate that the proposed model can detect the escape events more effectively from dense crowd.

The Study on the Verification of Speaker Change using GMM-UBM based KL distance (GMM-UBM 기반 KL 거리를 활용한 화자변화 검증에 대한 연구)

  • Cho, Joon-Beom;Lee, Ji-eun;Lee, Kyong-Rok
    • Journal of Convergence Society for SMB
    • /
    • v.6 no.4
    • /
    • pp.71-77
    • /
    • 2016
  • In this paper, we proposed a verification of speaker change utilizing the KL distance based on GMM-UBM to improve the performance of conventional BIC based Speaker Change Detection(SCD). We have verified Conventional BIC-based SCD using KL-distance based SCD which is robust against difference of information volume than BIC-based SCD. And we have applied GMM-UBM to compensate asymmetric information volume. Conventional BIC-based SCD was composed of two steps. Step 1, to detect the Speaker Change Candidate Point(SCCP). SCCP is positive local maximum point of dissimilarity d. Step 2, to determine the Speaker Change Point(SCP). If ${\Delta}BIC$ of SCCP is positive, it decides to SCP. We examined verification of SCP using GMM-UBM based KL distance D. If the value of D on each SCP is higher than threshold, we accepted that point to the final SCP. In the experimental condition MDR(Missed Detection Rate) is 0, FAR(False Alarm Rate) when the threshold value of 0.028 has been improved to 60.7%.

A Pilot Study of Acupuncture Treatment for the Osteoarthritis of the Knee Joint on the EBM(Evidence Basement Medicine) (근거중심의학에 근거한 퇴행성 슬관절염에 관한 침치료 임상선행연구)

  • Lim, Jeong-A;Lee, Jong-Deok;Lee, Sang-Kwan;Lee, Sung-Young;Moon, Hyung-Cheol;Choi, Sun-Mi;Chung, Young-Hae;Kim, Sung-Chul
    • Journal of Acupuncture Research
    • /
    • v.23 no.1
    • /
    • pp.187-215
    • /
    • 2006
  • Objectives : To determine whether the pragmatic acupuncture treatment provides more effective pain relief than treatment using the same acupuncture point to the all patients. Methods : We randomly allocated participants to treatment group 1 and 2. The group 1 is the pragmatic treatment group and the group 2 is using the same acupuncture point to the all patients. Primary outcomes were measured by the Western Ontario and McMaster Universities Osteoarthritis index(WOMAC) pain and function scores at 4, 8, and 14 weeks. Secondary outcomes were measured by 100mm VAS(Visual Analog Scale), ROM(Range of Motion) using Goniometer, and pain threshold using pressure algometer. Results : When patients were extension of the knee, they were statistically significant in improvement of the ROM in 14 weeks. Whole body condition and pain rate through VAS measurement were improved significantly in 14 weeks. Also pain score and function score of WOMAC were improved significantly in 14 weeks. We could get difference in pain score of two acupuncture groups significantly in 14 weeks. But we could not get difference in whole score of two acupuncture groups significantly. Local temperature using T.C thermometer was changed significantly in 14 weeks. But we could not get difference in whole score of two acupuncture groups significantly. Excluding above item, DITI, pain threshold, and ROM of the knee flexion were no difference in before and after treatment.

  • PDF

Fluid-elastic Instability in a Tube Array Subjected to Two-Phase Cross Flow (2 상 횡 유동장에 놓인 관군의 유체탄성불안정성)

  • Sim, Woo-Gun;Park, Mi-Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.2
    • /
    • pp.124-132
    • /
    • 2009
  • Experiments have been performed to investigate fluid-elastic instability of tube bundles, subjected to twophase cross flow. Fluid-elastic is the most important vibration excitation mechanism for heat exchanger tube bundles subjected to the cross flow. The test section consists of cantilevered flexible cylinder(s) and rigid cylinders of normal square array. From a practical design point of view, fluid-elastic instability may be expressed simply in terms of dimensionless flow velocity and dimensionless mass-damping parameter. For dynamic instability of cylinder rows, added mass, damping and the threshold flow velocity are evaluated. The Fluid-elastic instability coefficient is calculated and then compared to existing results given for tube bundles in normal square array.

Thermodynamic Incompatibility of Food Macromolecules (식품 거대분자의 열역학적 비혼합성)

  • 황재관;최문정
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.27 no.5
    • /
    • pp.1019-1025
    • /
    • 1998
  • Proteins and polysaccharides are major food macromolecules. Generally, the mixture of these macromolecules can be separated into two phases because of their thermodynamic incompatibility. Phase separ-ation is explained by equilibrium phase diagram, which comprises binodal curve, critical point, phase separation threshold, tie-line and rectilinear diameter. Phase separation of protein-polysacc-haride solution is affected by pH, temperature, ionic strength, molecular weight, molecular structure, etc. Membraneless osmosis has been developed to concentrate protein solutions, using the phase diagram constituted by proteins and polysaccharides. Protein-polysaccharide mixtures are very promising fat mimetics because solution of mixtures forms water-continuous system with two phase-separated gels, which give plastic texture and a fatty mouthfeel.

  • PDF

DYNAMICS OF AN IMPROVED SIS EPIDEMIC MODEL

  • Reza Memarbashi;Milad Tahavor
    • The Pure and Applied Mathematics
    • /
    • v.30 no.2
    • /
    • pp.203-220
    • /
    • 2023
  • A new modification of the SIS epidemic model incorporating the adaptive host behavior is proposed. Unlike the common situation in most epidemic models, this system has two disease-free equilibrium points, and we were able to prove that as the basic reproduction number approaches the threshold of 1, these two points merge and a Bogdanov-Takens bifurcation of codimension three occurs. The occurrence of this bifurcation is a sign of the complexity of the dynamics of the system near the value 1 of basic reproduction number. Both local and global stability of disease-free and endemic equilibrium point are studied.