• 제목/요약/키워드: two-layer aquifer

검색결과 26건 처리시간 0.027초

분할유동차원 2층 대수층에서의 투수성, 층간흐름, 저류성의 효과 (Permeability, crossflow and storativity effects in two-layer aquifer system with fractional flow dimension)

  • 함세영
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 추계학술대회
    • /
    • pp.81-84
    • /
    • 2000
  • Two-layer aquifer system with fractional flow dimension is composed of contiguous two layers: Layer 1 (lower layer) and Layer 2 (upper layer) with different permeability and specific storage each other. For this aquifer system, we assume that groundwater flow originates only from Layer 1 on the pumping well. The aquifer system considers wellbore storage and skin effects on the pumping well. Dimensionless drawdown curves for different flow dimensions are analyzed for different lambda (λ, crossflow coefficient) values, kappa ($textsc{k}$, permeability ratio between Layer 1 and Layer 2) values and omega ($\omega$, storativity ratio between Layer 1 and Layer 2) values. The curves for Layer 1 and Layer 2 show characteristic trend each other.

  • PDF

다층-대수층 시스템의 지하수 해석 (An Analysis of Groundwater Flow in the Multi-aquifer System)

  • 김민환;전일권;정재성
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제7권4호
    • /
    • pp.10-16
    • /
    • 2002
  • 본 연구의 목적은 누수대수층으로 분리된 다층-대수층에 대한 지하수 해석이다. Crank-Nicolson방법에 의한 유한차분법을 적용하여 1차원이며 정상상태인 2중 대수층 구조에 대해 해석해와 비교하였다. 수치해와 해석해는 거의 일치하였으므로 수치해를 2차원의 확장된 다층-대수층 구조에 적용하였다. 이는 한 개 또는 여러 개의 대수층에서 양수하는 경우에 각 대수층에서의 수두값을 계산할 수 있게 하였다. 본 연구는 지하수의 효율적인 운영에 도움이 될 것이다.

FEFLOW를 이용한 천부지열 활용 예측 모델링

  • 심병완;송윤호;김형찬
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.399-402
    • /
    • 2004
  • An aquifer thermal energy storage (ATES) model is simulated by FEFLOW according to the scenario of heat pump operation in two layered confining aquifer. The scenario is consisted of 4 steps: 90 days pumping (west well) and waste water injection (east well: 35 $^{\circ}C$), 90 day s stop, 90days pumping (east well) and waste water injection (west well: 5 $^{\circ}C$), and 95 days stop. The injection of the waste water is limited in the second layer and the first layer is aquitard. The temperature distribution at the surface shows low difference with reference temperature and opposit aspect with that of the second layer because the thermal transition through the first layer is very slow. Even though the simulated thermal transition in the aquifer system have a difference with real ATES system, optimal design and operate system can be developed with field tests and operational experience.

  • PDF

누수대수층에 대한 수리상수 추정과 해석 (Parameters Estimation and Analysis for Leaky Aquifer System)

  • 김민환
    • 대한지하수환경학회지
    • /
    • 제5권3호
    • /
    • pp.123-128
    • /
    • 1998
  • 본 연구에서 고려한 누수대수층 구조는 상부의 자유면대수층과 하부의 피압대수층으로 구성되어있으며 이들 사이에 누수층(leaky layer)이 있다. 상부 지하수 수위의 하강에 따른 피해 방지와 효율적인 지하수 관리를 위해서 상부와 하부의 지하수 수두 변화가 동시에 파악되어야 한다. 누수대수층 구조의 피압대수층(하부)에서 양수를 할때 자유면대수층(상부)은 하부와 상부 대수층을 구분하는 누수층의 영향을 받게 된다. 누수층을 해석하기 위해서 이 층에 대한 수리상수의 결정이 필요하다. 본 논문에서 수리상수를 결정하기 위한 개선된 SM(slope-matching)방법을 제시하였다. 그리고 누수대수층 구조에서 상부와 하부의 지하수 수두를 예측하기 위해 유한차분법을 이용하여 수치모형을 구성하였다. 수치모형의 검증을 위해 1차원 누수대수층 구조에 대한 해석해를 이용하여 정상류 상태에서 수두를 비교하였다. 그 결과는 잘 일치하고 있으며 2차원 누수대수층의 하부층인 피압대수층에서 양수를 할 때 상부 대수층과 하부 대수층에서 지하수 수두의 거동을 고찰하였다.

  • PDF

대수층 축열 에너지 활용 모델의 온도 분포 시뮬레이션 연구 (A study of the simulation of thermal distribution in an aquifer thermal energy storage utilization model)

  • 심병완;송윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.697-700
    • /
    • 2005
  • Aquifer Thermal Energy Storage (ATES) system can be very cost-effective and renewable energy sources, depending on site-specific parameters and load characteristics. In order to develop an ATES system which has certain hydrogeological characteristics, understanding of the thermo hydraulic processes of an aquifer is necessary for a proper design of an aquifer heat storage system under given conditions. The thermo hydraulic transfer for heat storage is simulated using FEFLOW according to two sets of pumping and waste water reinjection scenarios of heat pump operation in a two layered confined aquifer. In the first set of model, the movement of the thermal front and groundwater level are simulated by changing the locations of injection and pumping well in seasonal cycle. However, in the second set of model the simulation is performed in the state of fixing the locations of pumping and injection well. After 365 days simulation period, the temperature distribution is dominated by injected water temperature and the distance from injection well. The small temperature change is appears on the surface compared to other slices of depth because the first layer has very low porosity and the transfer of thermal energy are sensitive at the porosity of each layer. The groundwater levels and temperature changes in injection and pumping wells are monitored to validate the effectiveness of the used heat pump operation method and the thermal interference between wells is analyzed.

  • PDF

Hunt 해석해를 이용한 천부대수층 지하수 양수로 인한 하천수 감소 영향 분석 (Evaluation of stream depletion from groundwater pumping in shallow aquifer using the Hunt's analytical solution)

  • 이정우;정일문;김남원;홍성훈
    • 한국수자원학회논문집
    • /
    • 제49권11호
    • /
    • pp.923-930
    • /
    • 2016
  • 본 연구에서는 2층 누수대수층-하천 시스템에 관한 Hunt (2009)의 해석해를 이용하여 천부대수층 지하수 양수가 하천수량에 미치는 영향을 분석하였다. 대수층 및 하상의 수리특성 조건에 따라 총 2,187가지 경우의 수에 대해서 양수량 대비 하천수 감소량을 산정한 결과 하천고갈인자가 1,000-10,000 보다 큰 경우에 비교적 작은 값을 나타내었으며, 하천바닥층 수리전도도보다는 1, 2층간 반대수층의 수리전도도 크기에 상대적으로 민감한 반응을 보였다. 또한, Hunt (1999)의 해석해로 산정한 하천수 감소비에 비해 최대 0.3을 넘는 차이가 발생하는 등 1층의 하천고갈인자가 큰 경우에는 2층의 수리특성치에 큰 영향을 받는 것으로 분석되었다. 실제로 충주시에 위치한 임의의 천부지하수 관정에 적용하여 양수 경과시간에 따른 하천수 감소비를 산정한 결과 수일 내로 0.8을 초과하여 하천수에 미치는 영향이 단기간에 크게 발생하였으며, 또한 누수계수가 작고 천부대수층의 수리확산계수가 큰 지역에서는 하천-관정 이격거리가 하천수 감소량 크기를 결정하는데 지배적인 인자인 것으로 분석되었다.

해석적 모형을 이용한 심부대수층 지하수 양수로 인한 하천수 감소량 분석 (Evaluation of Stream Depletion from Groundwater Pumping in Deep Aquifer Using An Analytical Model)

  • 이정우;정일문;김남원
    • 대한토목학회논문집
    • /
    • 제36권5호
    • /
    • pp.769-777
    • /
    • 2016
  • 본 연구에서는 2층 누수대수층 시스템에 관한 Ward and Lough (2011)의 해석해를 이용하여 심부대수층 양수로 인한 하천수 감소량을 분석하였다. 하천변에 위치한 110개 지하수 관정 각각에 대해 양수량 대비 하천수 감소량을 산정한 결과 양수기간 5년 동안 작게는 0.1미만에서 크게는 0.8을 초과하여 관정 위치에 따라 큰 차이를 나타내었다. 단일 대수층 구조에 대한 Hunt (1999) 해석해 적용 결과와의 비교를 통해서 Ward and Lough (2011)의 해석해로 구한 하천수 감소량은 두 층의 수리특성의 상이함과 연직 방향 지체의 영향으로 평균적으로 약 50 % 만큼 작게 산정되었다. 충적층에 대한 하천고갈인자가 약 1,000 보다 크거나 암반층의 하천고갈인자가 100보다 큰 경우, 또는 연직 누수계수가 $10^{-5}s^{-1}$보다 작을 경우에는 지하수 양수가 하천수 감소에 미치는 영향이 작은 것으로 분석되었다. 또한 미 측정값인 충적층의 투수량계수 및 저류계수, 충적층과 연결된 하천의 하상수리전도도, 암반층 연직수리전도도 등의 크기에 따른 하천수 감소량의 변동 특성을 평가하였다.

다공질매체내의 류체류동 (Fluid flow in a Two-layer porous medium)

  • 이충구;조성환
    • 기계저널
    • /
    • 제16권1호
    • /
    • pp.49-53
    • /
    • 1976
  • Groundwater flow in a two-layer aquifer is studied theoretically and experimentally. Nonlinear differential equations are independently linearized for the upper and the lower layer, and approximate solutions are obtained. Fine sands and coarse sands are used in experiments. For steady flow, theoretical solutions agrees excellently with experimental results For unsteady flow, however, agreement is not so good, because the experimental conditions do not match with theoretical assumptions.

  • PDF

해수 침투에 대한 층상 불균질성 및 지하수 양수 방식의 영향 삼차원 수치 모의 (Three-Dimensional Numerical Simulation of Impacts of Layered Heterogeneity and Groundwater Pumping Schemes on Seawater Intrusion)

  • 박화석;김중휘;염병우;김준모
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제13권4호
    • /
    • pp.8-21
    • /
    • 2008
  • 지질 매체의 층상 불균질성과 지하수 양수 방식이 해안 대수층 내에서의 지하수 유동과 염분 이동에 미치는 영향을 정량적으로 분석하기 위하여 수리동역학적 분산 수치 모델을 이용한 일련의 삼차원 수치 모델링이 수행되었다. 해수 침투에 대한 층상 불균질성의 영향을 평가하기 위하여 하부 사토층(대수층)과 상부 점토층(준대수층)으로 구성된 층상 불균질 해안 대수층과 이에 상응하는 등가의 물질로 구성된 균질 해안 대수층을 수치 모델링하였다. 또한 해수 침투에 대한 지하수 양수 방식의 영향을 평가하기 위하여 전체 수치 모델링 기간 동안에 동일한 양의 지하수를 양수하는 연속적인 지하수 양수 방식과 두 개의 주기적인 지하수 양수 방식을 상기한 두 해안 대수층에 적용하였다. 수치 모델링 결과는 주기적인 지하수 양수 방식이 층상 대수층의 하부 사토층뿐만 아니라 상부 점토층에서의 지하수 유동과 염분 이동에 보다 중대한 악영향을 끼치며, 주기적인 지하수 양수 시에 양수 강도가 클수록 지하수 염수화가 공간적 및 시간적으로 더욱 심화됨을 보여준다. 이는 해수 침투에 의한 지하수 염수화를 최소화하기 위해서는 지속적인 지하수 양수 방식이 보다 더 적합할 수 있음을 의미한다. 또한 수치 모델링 결과는 주기적인 지하수 양수시에 상부 점토층에서의 지하수 염수화 양상이 하부 사토층에서의 그것에 비해 매우 다르게 발생함을 보여준다. 이러한 두 지층 사이의 지하수 염수화 양상의 차이는 층상 해안 대수층의 층상 불균질성에 기인하는 것으로 해석된다.