• Title/Summary/Keyword: two-dimensional treatment

Search Result 447, Processing Time 0.029 seconds

A study on the development of 64 channels computerized cardiac mapping system (64채널 심장전기도 시스템 구현에 관한 연구)

  • Chang, Byung-Chul;Kim, Nam-Hyun;Jung, Sung-Hun;Ra, Sang-Weon;Cho, Bum-Koo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.88-91
    • /
    • 1994
  • It is well known that multipoint and computerized intraoperative mapping systems improve the results of surgery for Wolff-Parkinson-White syndrome and show tremendous potential for opening an entirely new era of surgical intervention for the more common and lethal types of supraventricular tachyarrhythmias such as atrial flutter and atrial fibrillation. In addition, the ability to map and ablate the sometimes fleeting automatic atrial tachycardia is greatly enhanced by computerized mapping systems. In this study, we have developed 64 channel computerized data analysis system using microcomputer (Macintosh IIx) for basic research of electrophysiology and electrical propagation. The bipolar electrogram information is acquired from 64 cardiac sites simultaneously at a sampling rate of 1ksamples/sec with continuous and total data storage of up to 30 seconds. When the reference electrogram is selected and reference point is picked up, delay time from the reference point in displayed on two dimensional diagram of the heart. System design permits easy expansion to almost 256 simultaneous sites, This system is expected to enable us to study pathophysiology of cardiac arrhythmia and to improve the results of diagnosis and surgical treatment for cardiac arrhythmia.

  • PDF

Analysis of setup error at rectal cancer radiotherapy technique (직장암 방사선치료기법별 자세오차에 관한 분석)

  • Kim, Jeong-Ho;Bae, Seok-Hwan;Kim, Ki-Jin;Yu, Se-Jong;Kim, Jee-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6346-6352
    • /
    • 2013
  • Radiotherapy of rectal cancer requires a stabilized image but the movement of patients is almost unavoidable in radiotherapy. In this study, the setup error using the radiation treatment technique was compared according to the loading time and BMI(Body Mass Index) for 14 patients with rectal cancer. In addition, the variation of the dose by the average setup error was compared. Therefore, the technique of a selective standard was established. As a result, 3DCRT(3-Dimensional Radiation Therapy) and VMAT(Volumetric Modulated Arc Therapy) showed a similar time and error. In comparison, IMRT(Intensity Modulated Radiation Therapy) increased the time two fold and the error four fold. In BMI, a more pyknic patient showed a larger error for all techniques. Regarding the dose, IMRT and VMAT increased much more than 3DCRT in the average error at the small bowel. Therefore, 3DCRT of the short time will be applied to pyknic rectal cancer. Moreover, VMAT selects than IMRT in the overexposure of the small bowel.

Determination of Aneurysmal Location with 3 Dimension-Computed Tomographic Angiography in the Microsurgery of Paraclinoid Aneurysms

  • Kim, Min-Young;Chung, Seung-Young;Kim, Seung-Min;Park, Moon-Sun;Jung, Sung-Sam
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • Objective : Determining the location of paraclinoid aneurysms for microsurgery is important for selecting treatment options, especially when deciding on the release of the dural ring in direct clipping. We examined the reliability of using the optic strut as an anatomical landmark for evaluating the location of paraclinoid aneurysms. Methods : Cadaveric dissection was performed to establish the relationship of the optic strut to the dural ring. Results from these anatomic studies were compared with the three-demensional computed tomographic angiographic [3D-CTA] findings of nine patients with ten paraclinoid aneurysms between May 2004 and October 2005. These, 3D-CTA results were then compared with intraoperative findings. Results : The inferior boundary of the optic strut accurately localized the point at the proximal dural ring in cadaveric study. The optic strut and its relationship to the aneurysms was well observed on the multiplanar reformats of 3D-CTA. During microsurgery, nine of ten aneurysms were verified to arise from distal to the upper surface of the optic strut. Two aneurysms that had arisen between the inferior and superior boundary of the optic strut were observed to lie within the carotid cave. One aneurysm which had arisen at the inferior boundary of the optic strut and directed inferiorly was observed to lie within the cavernous sinus just after the release of the proximal ring. Conclusion : The optic strut, as identified with multiplanar reformats of 3D-CTA, provided a reliable anatomic landmark for the proximal rings and an important information about the location of aneurysms around the anterior clinoid process (ACP). Therefore, 3D-CTA and the optic strut could become an invaluable tool and a landmark in the assessment of the location of paraclinoid aneurysms for microsurgery.

The Effect of Sa-Am Lung Tonifying Acupuncture on Radial Pulse in Healthy Human Subjects (폐정격(肺正格) 자침이 촌관척(寸關尺) 맥파 변화에 미치는 영향)

  • Kim, Na-Yeon;Kang, Jae-Hui;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.29 no.5
    • /
    • pp.17-29
    • /
    • 2012
  • Objectives : The purpose of this study is to find the effects of Sa-Am lung tonifying acupuncture on radial pulse through the parameters difference. Methods : Forty healthy subjects participated in this study, acupuncture group and control group were divided. Compared various parameters of radial pulse between two groups, and the significantly changed 16 parameters ware measured using 3 dimensional pulse imaging system(DMP-3000) before, right after, 30 minutes after, and 60 minutes after acupuncture at Chon, Gwan, Cheok in acupucture group. Results : After lung tonifying acupuncture, radial pulse 16 parameters were showed changes significantly according to the time at each measuring location. 1. Heart rate, T2/T, T5, T5/T and W/T significantly decreased, W significantly increased. 2. Modulus of elasticity significantly decreased in left Cheok. 3. Amplitude of H4 significantly increased in left Gwan and right Cheok. 4. AIx, AIxHR significantly decreased in left Gwan and significantly increased in right Chon. 5. Area of pulse, area of W significantly increased in right Cheok. 6. Pulse energy, energy/min, EIx significantly decreased in left Cheok. 7. Maximum variation time of each parameter is showed different according to the parameter. Conclusions : Lung tonifying acupuncture exerts an influence on radial purse parameters. Further radial pulse change study on various acupuncture treatment is required.

The use of digital periapical radiographs to study the prevalence of alveolar domes

  • Xambre, Pedro Augusto Oliveira Santos;Valerio, Claudia Scigliano;Cardoso, Claudia Assuncao e Alves;Custodio, Antonio Luis Neto;Manzi, Flavio Ricardo
    • Imaging Science in Dentistry
    • /
    • v.46 no.3
    • /
    • pp.179-184
    • /
    • 2016
  • Purpose: In the present study, we coined the term 'alveolar dome' and aimed to demonstrate the prevalence of alveolar domes through digital periapical radiographs. Materials and Methods: This study examined 800 digital periapical radiographs in regard to the presence of alveolar domes. The periapical radiographs were acquired by a digital system using a photostimulable phosphor (PSP) plate. The ${\chi}^2$ test, with a significance level of 5%, was used to compare the prevalence of alveolar domes in the maxillary posterior teeth and, considering the same teeth, to verify the difference in the prevalence of dome-shaped phenomena between the roots. Results: The prevalence of alveolar domes present in the first pre-molars was statistically lower as compared to the other maxillary posterior teeth (p<0.05). No statistically significant difference was observed in the prevalence of alveolar domes between the maxillary first and second molars. Considering the maxillary first and second molars, it was observed that the palatal root presented a lower prevalence of alveolar domes when compared to the distobuccal and mesiobuccal roots (p<0.05). Conclusion: The present study coined the term 'alveolar dome', referring to the anatomical projection of the root into the floor of the maxillary sinus. The maxillary first and second molars presented a greater prevalence of alveolar domes, especially in the buccal roots, followed by the third molars and second pre-molars. Although the periapical radiograph is a two-dimensional method, it can provide dentists with the auxiliary information necessary to identify alveolar domes, thus improving diagnosis, planning, and treatment.

Development of Computer Assisted 3-D Simulation and Prediction Surgery in Craniofacial Distraction Osteogenesis (악안면 골신장술의 치료계획을 위한 3차원 시뮬레이션 프로토콜의 개발)

  • Paeng Jun-Young;Lee Jee-Ho;Lee Jong-Ho;Baek Seung-Hak;Kim Myung-Jin
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.6 no.2
    • /
    • pp.91-105
    • /
    • 2003
  • There are significant limitations in the precision of mandibular distraction in setting a desired occlusal and facial esthetic outcome. The purpose of this study is to present the simulation method for the distraction osteogenesis treatment planning. 3-D surgery simulation software programs V-works and V-Surgery(Cybermed, Seoul, Korea) were used from the 3D CT data in addition to the conventional data facial photography, panorama and cephalogram, dental cast model. We have utilized already for the various surgical procedures to get information preoperatively for the maxillofacial surgery like cancer localization and reconstructive surgery, orthognathic surgery and implant surgery in the department of Oral and Maxillofacial surgery, Seoul National University Hospital. On the software, bone cutting can be done at any place and any direction. Separated bone segment can be mobilized in all 3 dimensional direction. After the 3D simulation on the software program, mock surgery on the RP model can be performed. This planning method was applied to two hemifacial microsomia patients. With this protocol, we could simulate the movement of bony segment after maxillofacial distraction osteogenesis

  • PDF

Positional changes in the mandibular proximal segment after intraoral vertical ramus osteotomy: Surgery-first approach versus conventional approach

  • Jung, Seoyeon;Choi, Yunjin;Park, Jung-Hyun;Jung, Young-Soo;Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.50 no.5
    • /
    • pp.324-335
    • /
    • 2020
  • Objective: To compare postoperative positional changes in the mandibular proximal segment between the conventional orthognathic surgery (CS) and the surgery-first approach (SF) using intraoral vertical ramus osteotomy (IVRO) in patients with Class III malocclusion. Methods: Thirty-eight patients with skeletal Class III malocclusion who underwent bimaxillary surgery were divided into two groups according to the use of preoperative orthodontic treatment: CS group (n = 18) and SF group (n = 20). Skeletal changes in both groups were measured using computed tomography before (T0), 2 days after (T1), and 1 year after (T2) the surgery. Three-dimensional (3D) angular changes in the mandibular proximal segment, condylar position, and maxillomandibular landmarks were assessed. Results: The mean amounts of mandibular setback and maxillary posterior impaction were similar in both groups. At T2, the posterior portion of the mandible moved upward in both groups. In the SF group, the anterior portion of the mandible moved upward by a mean distance of 0.9 ± 1.0 mm, which was statistically significant (p < 0.001). There were significant between-group differences in occlusal changes (p < 0.001) as well as in overjet and overbite. However, there were no significant between-group differences in proximal segment variables. Conclusions: Despite postoperative occlusal changes, positional changes in the mandibular proximal segment and the position of the condyles were similar between CS and SF, which suggested that SF using IVRO achieved satisfactory postoperative stability. If active physiotherapy is conducted, the proximal segment can be adapted in the physiological position regardless of the occlusal changes.

A Computational Study of the Focusing Phenomenon of Weak Shock Wave (약한 충격파의 포커싱 현상에 관한 수치해석적 연구)

  • Kweon Yong Hun;Kim Heuy Dong
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.169-172
    • /
    • 2002
  • When a plane shockwave reflects ken a concave wall, it is focused at a certain location, resulting in extremely high local pressure and temperature. This focusing is due to a nonlinear phenomenon of shock wave. The focusing phenomenon has been extensively applied to many diverse folds of engineering and medical treatment as well. In the current study, the focusing of shock wave over a reflector is numerically investigated using a CFD method. The Harten-Yee total variation diminishing (TVD) scheme is used to solve the unsteady, two-dimensional, compressible, Euler equations. The incident shock wave Mach number $M_{s}\;of\;1.1{\~}l.3$ is applied to the parabolic reflectors with several different depths. Detailed focusing characteristics of the shock wave are investigated in terms of peak pressure, gasdynamic and geometrical foci. The results obtained are compared with the previous experimental results. The results obtained show that the peak pressure of shock wave focusing and its location strongly depend on the magnitude of the incident shock wave and depth of parabolic reflector. It is also found that depending up on the depth of parabolic reflector, the weak shock wave focusing process can classified into three distinct patterns : the reflected shock waves do not intersect each other before and after focusing, the reflected shock waves do not intersect each other before focusing, but intersect after focusing, and the reflected shock waves intersect each other before and after focusing. The predicted Schlieren images represent the measured shock wave focusing with a good accuracy.

  • PDF

An Algorithim for Converting 2D Face Image into 3D Model (얼굴 2D 이미지의 3D 모델 변환 알고리즘)

  • Choi, Tae-Jun;Lee, Hee-Man
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.4
    • /
    • pp.41-48
    • /
    • 2015
  • Recently, the spread of 3D printers has been increasing the demand for 3D models. However, the creation of 3D models should have a trained specialist using specialized softwares. This paper is about an algorithm to produce a 3D model from a single sheet of two-dimensional front face photograph, so that ordinary people can easily create 3D models. The background and the foreground are separated from a photo and predetermined constant number vertices are placed on the seperated foreground 2D image at a same interval. The arranged vertex location are extended in three dimensions by using the gray level of the pixel on the vertex and the characteristics of eyebrows and nose of the nomal human face. The separating method of the foreground and the background uses the edge information of the silhouette. The AdaBoost algorithm using the Haar-like feature is also employed to find the location of the eyes and nose. The 3D models obtained by using this algorithm are good enough to use for 3D printing even though some manual treatment might be required a little bit. The algorithm will be useful for providing 3D contents in conjunction with the spread of 3D printers.

Biomechanical Analysis of the Implanted Constrained and Unconstrained ICR Types of Artificial Disc using FE Model (순간중심 고정식 및 이동식 인공디스크 적용에 대한 유한요소 모델을 이용한 생체역학적 분석)

  • Yun Sang-Seok;Jung Sang-Ki;Kim Young-Eun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.4 s.181
    • /
    • pp.176-182
    • /
    • 2006
  • Although several artificial disc designs have been developed for the treatment of discogenic low back pain, biomechanical changes with its implantation were rarely studied. To evaluate the effect of artificial disc implantation on the biomechanics of functional spinal unit, a nonlinear three-dimensional finite element model of L4-L5 was developed with 1-mm CT scan data. Biomechanical analysis was performed for two different types of artificial disc having constrained and unconstrained instant center of rotation(ICR), ProDisc and SB Charite III model. The implanted model predictions were compared with that of intact model. Angular motion of vertebral body, forces on the spinal ligaments and facet joint, and stress distribution of vertebral endplate for flexion-extension, lateral bending, and axial rotation with a compressive preload of 400N were compared. The implanted model showed increased flexion-extension range of motion compared to that of intact model. Under 6Nm moment, the range of motion were 140%, 170% and 200% of intact in SB Charite III model and 133%, 137%, and 138% in ProDisc model. The increased stress distribution on vertebral endplate for implanted cases could be able to explain the heterotopic ossification around vertebral body in clinical observation. As a result of this study, it is obvious that implanted segment with artificial disc suffers from increased motion and stress that can result in accelerated degenerated change of surrounding structure. Unconstrained ICR model showed increased in motion but less stress in the implanted segment than constrained model.