• Title/Summary/Keyword: two-dimensional detection

Search Result 348, Processing Time 0.03 seconds

Calibration of Optical Dimensional Measurement System Using Optical Microscope (광학현미경을 이용한 비접촉식 치수측정시스템의 교정)

  • Park, Hyun-Goo;Park, Min-Cheol;Kim, Seung-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.11
    • /
    • pp.118-125
    • /
    • 1997
  • Non-contacting optical microscopes are increasingly used in recent industrial applications of probes for coordinate measuring machines. They have been found more efficient than conventional touch trigger porbes with ball tips especially in inspecting small-sized objects. There are two major factors affecting measuring accuracy: (1) geometric relations between coordinate systems, (2) magnification ratios of a microscope. In order to determine the magnification ratios exactly, optical imaging of edge was theroretically analyzed and practically adopted to image processing for edge detection. In addition, this paper proposes a geometric calibration method to obtain exact coordinates of measured points from the relations between the machine coordinate system and the image. In the method, the error according to the squareness between the machine axises was also removed. The method was practically adopted to a real coordinate measuring machine. An ultraprecision measurement of 0.2 um uncertainty can be practically achieved.

  • PDF

Spontaneous closure of perimembranous ventricular septal defect in a cat

  • Soolyi Park;Hyunseon Jeong;Seunggon Lee
    • Korean Journal of Veterinary Research
    • /
    • v.63 no.4
    • /
    • pp.36.1-36.4
    • /
    • 2023
  • We discuss the case of a 5-month-old male British Shorthair cat referred to our hospital following the detection of a heart murmur during a routine vaccination appointment. Two-dimensional echocardiography revealed a 1.18 mm ventricular septal defect (VSD) located immediately below the aortic valve, without signs of secondary cardiac remodeling. Given the absence of cardiac dysfunction, no treatment was administered, and the cat was periodically monitored over the next 2 years. Echocardiography at 29 months of age revealed no signs of the VSD. Future studies are needed to increase the evidence base for spontaneous VSD closure in small animals.

Three-Dimensional Digital Subtraction Angiographic Evaluation of Aneurysm Remnants after Clip Placement

  • Ahn, Soon-Seob;Kim, Young-Don
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.3
    • /
    • pp.185-190
    • /
    • 2010
  • Objective : The aneurysm remnants rate was evaluated via three-dimensional digital subtraction angiography (3D-DSA) in the postoperative evaluation of clipped aneurysms. Methods : Data on surgically clipped aneurysms of anterior circulation obtained via postoperative 3D-DSA from February 2007 to March 2009 were gathered. The results of the postoperative 3D-DSA and of two-dimensional digital subtraction angiography (2D-DSA) for the detection of aneurysm remnants were compared, and an investigation was performed as to why 2D-DSA had missed some aneurysm remnants that were detected in the 3D-DSA. Various surgical factors that revealed aneurysm remnants in the 3D-DSA were also evaluated. Results : A total of 39 neck remnants of 202 clipped aneurysms (19.3%) were confirmed in 3D-DSA, and these were classified according to Sindou's classification of aneurysm remnants. Patients with only a neck remnant found in the 3D-DSA represented 17.3% (35/202 aneurysms) of the whole series, and those with a residuum of neck plus sac found in the 3D-DSA represented 1.9% (4/202 aneurysms). The causes of aneurysm remnants were no full visualization (14/39, 35.9%), parent and perforator artery protection (10/39, 25.6%), clip design problems (8/39, 20.5%), and broadnecked aneurysm (7/39, 17.9%). Conclusion : Patients with ${\leq}2$mm aneurysm remnants showed an increased risk of undetectable aneurysm remnants in the 2D-DSA. The most frequent location of the missed aneurysm in 2D-DSA was the anterior communicating artery. 3D-DSA showed more aneurysm remnants than what is indicated in the existing literature, the 2D-DSA.

Automatic analysis of golf swing from single-camera video sequences (단일 카메라 영상으로부터 골프 스윙의 자동 분석)

  • Kim, Pyeoung-Kee
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.5
    • /
    • pp.139-148
    • /
    • 2009
  • In this paper, I propose an automatic analysis method of golf swine from single-camera video sequences. I define necessary swing features for automatic swing analysis in 2-dimensional environment and present efficient swing analysis methods using various image processing techniques including line and edge detection. The proposed method has two characteristics compared with previous swing analysis systems and related studies. First, the proposed method enables an automatic swing analysis in 2-dimension while previous systems require 3-dimensional environment which is relatively complex and expensive to run. Second, swing analysis is done automatically without human intervention while other 2-dimensional systems necessarily need analysis by a golf expert. I tested the method on 20 swing video sequences and found the proposed method works effective for automatic analysis of golf swing.

Keratanase II Digestion Accompanied with a Liquid Chromatography/Tandem Mass Spectrometry for Urinary Keratan Sulfate Quantitative Analysis

  • Chuang, Chih-Kuang;Lin, Hsiang-Yu;Wang, Tuen-Jen;Huang, Sung-Fa;Lin, Shuan-Pei
    • Journal of mucopolysaccharidosis and rare diseases
    • /
    • v.3 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: Mucopolysaccharidosis IV (MPS IV) is a disease characterized by deficient activity of N-acetylgalactosamine-6-sulfatase (GALNS) causing excessive lysosomal storage of keratan sulfate (KS). The identification of the relevant disaccharide units of KS after keratanase II digestion followed by liquid chromatography/tandem mass spectrometry detection (LC-MS/MS) is validated and applicable for the preliminary diagnosis of MPS IV. Methods: A total of 67 urine samples were collected and analyzed from 11 MPS IV patients comprising 10 MPS IVA and one MPS IVB patients, and 56 normal controls. Urinary glycosaminoglycan was first precipitated by the Alcian blue method followed by a digestion of keratanase II. The protonated species of the digested disaccharide products were detected by using multiple reaction monitoring experiment. Results: One particular disaccharide of KS was selected. The transition mass-to-charge (m/z) of the parent ion and its daughter ion after collision was $462.0{\rightarrow}97.0$, whereas the chondrosine used as an internal standard in this assay was m/z $353.9{\rightarrow}73.0$. The results corresponded well with the two-dimensional electrophoresis method. The quantities of urinary KS were significantly raised in confirmed MPS IV patients when comparing with those of normal controls ($170.2{\pm}81.1$ vs. $4.06{\pm}1.92{\mu}g/mL$). Conclusion: The LC-MS/MS method for MPS IVA determination is specific, sensitive, validated, and applicable for urinary KS quantification. This method can be used not only as a first-line biochemistry examination of MPS IVA, but also as an outcome survey after enzyme replacement therapy.

Vision-based Potato Detection and Counting System for Yield Monitoring

  • Lee, Young-Joo;Kim, Ki-Duck;Lee, Hyeon-Seung;Shin, Beom-Soo
    • Journal of Biosystems Engineering
    • /
    • v.43 no.2
    • /
    • pp.103-109
    • /
    • 2018
  • Purpose: This study has been conducted to develop a potato yield monitoring system, consisting of a segmentation algorithm to detect potatoes scattered on a soil surface and a counting system to count the number of potatoes and convert the data from two-dimensional images to masses. Methods: First, a segmentation algorithm was developed using top-hat filtering and processing a series of images, and its performance was evaluated in a stationary condition. Second, a counting system was developed to count the number of potatoes in a moving condition and calculate the mass of each using a mass estimation equation, where the volume of a potato was obtained from its two-dimensional image, and the potato density and a correction factor were obtained experimentally. Experiments were conducted to segment potatoes on a soil surface for different potato sizes. The counting system was tested 10 times for 20 randomly selected potatoes in a simulated field condition. Furthermore, the estimated total mass of the potatoes was compared with their actual mass. Results: For a $640{\times}480$ image size, it took 0.04 s for the segmentation algorithm to process one frame. The root mean squared deviation (RMSD) and average percentage error for the measured mass of potatoes using this counting system were 12.65 g and 7.13%, respectively, when the camera was stationary. The system performance while moving was the best in L1 (0.313 m/s), where the RMSD and percentage error were 6.92 g and 7.79%, respectively. For 20 newly prepared potatoes and 10 replication measurements, the counting system exhibited a percentage error in the mass estimation ranging from 10.17-13.24%. Conclusions: At a travel speed of 0.313 m/s, the average percentage error and standard deviation of the mass measurement using the counting system were 12.03% and 1.04%, respectively.

Security Analysis of MAC Algorithm using Block Cipher (블록 암호 알고리즘을 애용한 MAC 분석)

  • Seo Chang-Ho;Yun Bo-Hyun;Maeng Sung-Reol
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.2 s.34
    • /
    • pp.39-47
    • /
    • 2005
  • This paper proposes and analyzes the MAC(Message Authentication Code) algorithm that is used for the transition integrity and the entity authentication of message. The MAC algorithm uses the DES algorithm which has 64-bit block and 56-bit key and we compare the security according to 64-bit and 32-bit length of MAC value. Moreover, we use the SEED algorithm which has 128-bit block and 128-bit key and compare the security according to 128-bit and 64-bit length of MAC value. We analyze the security the forgery attack according to length of message and length of MAC value. this paper, a coarse-to-fine optical flow detection method is proposed. Provided that optical flow gives reliable approximation to two-dimensional image motion, it can be used to recover the three-dimensional motion. but usually to get the reliable optical flows are difficult. The proposed algorithm uses Horn's algorithm (or detecting initial optical flow, then Thin Plate Spline is introduced to warp a image frame of the initial optical flow to the next image frame. The optical flow for the warped image frame is again used iteratively until the mean square error between two image sequence frames is lowered. The proposed method is experimented for the real moving Picture image sequence. The proposed algorithm gives dense optical flow vectors.

  • PDF

Depthmap Generation with Registration of LIDAR and Color Images with Different Field-of-View (다른 화각을 가진 라이다와 칼라 영상 정보의 정합 및 깊이맵 생성)

  • Choi, Jaehoon;Lee, Deokwoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.28-34
    • /
    • 2020
  • This paper proposes an approach to the fusion of two heterogeneous sensors with two different fields-of-view (FOV): LIDAR and an RGB camera. Registration between data captured by LIDAR and an RGB camera provided the fusion results. Registration was completed once a depthmap corresponding to a 2-dimensional RGB image was generated. For this fusion, RPLIDAR-A3 (manufactured by Slamtec) and a general digital camera were used to acquire depth and image data, respectively. LIDAR sensor provided distance information between the sensor and objects in a scene nearby the sensor, and an RGB camera provided a 2-dimensional image with color information. Fusion of 2D image and depth information enabled us to achieve better performance with applications of object detection and tracking. For instance, automatic driver assistance systems, robotics or other systems that require visual information processing might find the work in this paper useful. Since the LIDAR only provides depth value, processing and generation of a depthmap that corresponds to an RGB image is recommended. To validate the proposed approach, experimental results are provided.

Proteomic Analysis of Polycyclic Aromatic Hydrocarbons (PAHs) Degradation and Detoxification in Sphingobium chungbukense DJ77

  • Lee, Soo Youn;Sekhon, Simranjeet Singh;Ban, Yeon-Hee;Ahn, Ji-Young;Ko, Jung Ho;Lee, Lyon;Kim, Sang Yong;Kim, Young-Chang;Kim, Yang-Hoon
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.11
    • /
    • pp.1943-1950
    • /
    • 2016
  • Polycyclic aromatic hydrocarbons (PAHs) are commonly present xenobiotics in natural and contaminated soils. We studied three (phenanthrene, naphthalene, and biphenyl) xenobiotics, catabolism, and associated proteins in Sphingobium chungbukense DJ77 by two-dimensional gel electrophoresis (2-DE) analysis. Comparative analysis of the growth-dependent 2-DE results revealed that the intensity of 10 protein spots changed identically upon exposure to the three xenobiotics. Among the upregulated proteins, five protein spots, which were putative dehydrogenase, dioxygenase, and hydrolase and involved in the catabolic pathway of xenobiotic degradation, were induced. Identification of these major multifunctional proteins allowed us to map the multiple catabolic pathway for phenanthrene, naphthalene, and biphenyl degradation. A part of the initial diverse catabolism was converged into the catechol degradation branch. Detection of intermediates from 2,3-dihydroxy-biphenyl degradation to pyruvate and acetyl-CoA production by LC/MS analysis showed that ring-cleavage products of PAHs entered the tricarboxylic acid cycle, and were mineralized in S. chungbukense DJ77. These results suggest that S. chungbukense DJ77 completely degrades a broad range of PAHs via a multiple catabolic pathway.

Source Image Based New 3D Rotational Angiography for Differential Diagnosis between the Infundibulum and an Internal Carotid Artery Aneurysm : Pilot Study

  • Jang, Hyeongyu;Jung, Woo Sang;Myoung, Seong Uk;Kim, Jung-Jae;Jang, Chang Ki;Cho, Kwang-Chun
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.726-731
    • /
    • 2021
  • Objective : Distinguishing between an infundibulum and a true aneurysm is clinically important. This study aimed to evaluate whether using source image based new three-dimensional rotational angiography (S-n3DRA) can increase the rate of aneurysm detection and improve distinction between a true aneurysm and an infundibulum. Methods : Twenty-two consecutive patients with 23 lesions, were evaluated by time-of-flight (TOF) magnetic resonance angiography (MRA), S-n3DRA, and digital subtraction angiography (DSA). The data were retrospectively and independently reviewed by two neurointerventionists, and the diagnoses based on TOF MRA, S-n3DRA, and DSA were compared. The diagnostic efficacy (interobserver agreement and diagnostic performance) of S-n3DRA was compared with that of TOF MRA. Results : S-n3DRA showed higher interobserver agreement (κ=0.923) than TOF MRA (κ=0.465) and significantly higher accuracy than MRA in distinguishing an aneurysm from an infundibulum (p=0.0039). Conclusion : Compared to MRA, S-n3DRA could provide better screening accuracy and information for distinguishing an aneurysm from an infundibulum. Therefore, S-n3DRA has the potential to reduce the need for DSA.