• 제목/요약/키워드: two adjacent structures

검색결과 236건 처리시간 0.022초

Cap truss and steel strut to resist progressive collapse in RC frame structures

  • Zahrai, Seyed Mehdi;Ezoddin, Alireza
    • Steel and Composite Structures
    • /
    • 제26권5호
    • /
    • pp.635-647
    • /
    • 2018
  • In order to improve the efficiency of the Reinforced Concrete, RC, structures against progressive collapse, this paper proposes a procedure using alternate path and specific local resistance method to resist progressive collapse in intermediate RC frame structures. Cap truss consists of multiple trusses above a suddenly removed structural element to restrain excessive collapse and provide an alternate path. Steel strut is used as a brace to resist compressive axial forces. It is similar to knee braces in the geometry, responsible for enhancing ductility and preventing shear force localization around the column. In this paper, column removals in the critical position at the first story of two 5 and 10-story regular buildings strengthened using steel strut or cap truss are studied. Based on nonlinear dynamic analysis results, steel strut can only decrease vertical displacement due to sudden removal of the column at the first story about 23%. Cap truss can reduce the average vertical displacement and column axial force transferred to adjacent columns for the studied buildings about 56% and 61%, respectively due to sudden removal of the column. In other words, using cap truss, the axial force in the removed column transfers through an alternate path to adjacent columns to prevent local or general failure or to delay the progressive collapse occurrence.

Directional adjacency-score function for protein fold recognition

  • Heo, Mu-Young;Cheon, Moo-Kyung;Kim, Suhk-Mann;Chung, Kwang-Hoon;Chang, Ik-Soo
    • Interdisciplinary Bio Central
    • /
    • 제1권2호
    • /
    • pp.8.1-8.6
    • /
    • 2009
  • Introduction: It is a challenge to design a protein score function which stabilizes the native structures of many proteins simultaneously. The coarse-grained description of proteins to construct the pairwise-contact score function usually ignores the backbone directionality of protein structures. We propose a new two-body score function which stabilizes all native states of 1,006 proteins simultaneously. This two-body score function differs from the usual pairwise-contact functions in that it considers two adjacent amino acids at two ends of each peptide bond with the backbone directionality from the N-terminal to the C-terminal. The score is a corresponding propensity for a directional alignment of two adjacent amino acids with their local environments. Results and Discussion: We show that the construction of a directional adjacency-score function was achieved using 1,006 training proteins with the sequence homology less than 30%, which include all representatives of different protein classes. After parameterizing the local environments of amino acids into 9 categories depending on three secondary structures and three kinds of hydrophobicity of amino acids, the 32,400 adjacency-scores of amino acids could be determined by the perceptron learning and the protein threading. These could stabilize simultaneously all native folds of 1,006 training proteins. When these parameters are tested on the new distinct 382 proteins with the sequence homology less than 90%, 371 (97.1%) proteins could recognize their native folds. We also showed using these parameters that the retro sequence of the SH3 domain, the B domain of Staphylococcal protein A, and the B1 domain of Streptococcal protein G could not be stabilized to fold, which agrees with the experimental evidence.

스카이브릿지를 이용한 RC 주거용 건물의 진동제어 (Vibration Control of RC Residential Building Structure Using Sky-Bridge)

  • 안상경;오정근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.450-453
    • /
    • 2006
  • Coupling adjacent building with supplemental damping devices is a developing method of reduced structural response due to wind and seismic excitations. The philosophy is to allow structures, vibrating at different frequencies, to exert control forces upon one another to reduce the overall responses of the system. This paper studies the effect of installing vibration control devices of two high rise building structures(49 stories and 42 stories) connected by sky-bridge. According to the analysis results the use of sky-bridge can be effective in increasing damping ratio of the system.

  • PDF

패턴 인식을 통한 미소 구조물의 변형 측정 기법 개발 (An Experimental Technique with Pattern Recognition for Deformation Measurement of Small Structures)

  • 박태상;백동천;이순복
    • 소성∙가공
    • /
    • 제11권7호
    • /
    • pp.614-619
    • /
    • 2002
  • For an accurate measurement of the material behavior of small structures, a new optical experimental technique is proposed to measure the deformation. The test method uses the dual microscope that can measure the relative deformation of two adjacent regions. The magnified view is captured by CCD cameras and the relative deformation can be measured by the pattern matching and tracing method. Using this experimental technique, the deformation of solder joints in electronic packaging and the strain of the nickel thin film are measured.

MR 감쇠기의 준능동 퍼지제어기법을 이용한 인접구조물의 지진응답제어 (Seismic Response Control of Adjacent Structures by Semi-Active Fuzzy Control of Magneto-Rheological Damper)

  • 김민섭;옥승용;박관순
    • 한국지진공학회논문집
    • /
    • 제13권3호
    • /
    • pp.39-50
    • /
    • 2009
  • 인접건물 사이에 감쇠기 형태의 에너지 소산장치를 설치하고 연결함으로써, 지진 응답을 줄이고 내진 성능을 향상시킬 수 있는 방법에 대하여 연구를 수행하였다. 서로 인접한 건물 간의 진동제어를 위하여 준능동 MR 감쇠기를 이용하는 퍼지 제어기법을 제시하고, MR 감쇠기의 감쇠력 조절을 시간에 따라 제어할 수 있도록 제시한 방법으로 제어기를 설계하였다. 제시한 방법의 타당성을 검증하기 위하여 수치모사를 수행하였으며, 다양한 역사지진의 지진응답 해석을 통해서 비제어시, 수동제어 및 준능동 퍼지제어 등에 대한 최대응답을 비교 분석하였다. 수치모사 결과 제시한 방법은, 다양한 주파수 성분을 가진 여러 가지 지진에 대해 매우 효과적인 제진 성능을 보이는 것으로 나타났다.

근접 깊은 굴착에서 천공장비에 의한 지반교란 특성 사례 연구 (Case Study of Ground Disturbance Characteristic due to Drilling Machine in Adjacent Deep Excavation)

  • 김성욱;한병원
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.77-84
    • /
    • 2003
  • Deep excavations in the urban areas have been frequently going on in large scale. Soil-nailing and Earth-anchor supporting methods are generally used in deep excavation. These construction methods cause ground disturbances during drilling process, and damages of adjacent structures and ground due to the differential settlement throughout construction period, and unexpected behaviors of supporting system according to the characteristics of drilling machine and ground condition. This article introduces two actual examples of adjacent deep excavation for the construction of university buildings in granitic Seoul area. The important results of construction and measurements obtained using Crawler drilling machine for Soil-nailing and Earth-anchor supporting methods are summarized. And some suggestions are given to improve and develop the technique of design and construction in the deep excavation projects having similar ground condition and supporting method.

  • PDF

Mitigation of seismic collision between adjacent structures using roof water tanks

  • Mahmoud, Sayed
    • Earthquakes and Structures
    • /
    • 제18권2호
    • /
    • pp.171-184
    • /
    • 2020
  • The potential of using the roof water tanks as a mitigation measure to minimize the required separation gap and induced pounding forces due to collisions is investigated. The investigation is carried out using nonlinear dynamic analysis for two adjacent 3-story buildings with different dynamic characteristics under two real earthquake motions. For such analysis, nonlinear viscoelastic model is used to simulate forces due to impact. The sloshing force due to water movement is modelled in terms of width of the water tank and the instantaneous wave heights at the end wall. The effect of roof water tanks on the story's responses, separation gap, and magnitude and number of induced pounding forces are investigated. The influence of structural stiffness and storey mass are investigated as well. It is found that pounding causes instantaneous acceleration pulses in the colliding buildings, but the existence of roof water tanks eliminates such acceleration pulses. At the same time the water tanks effectively reduce the number of collisions as well as the magnitude of the induced impact forces. Moreover, buildings without constructed water tanks require wider separation gap to prevent pounding as compared to those with water tanks attached to top floor under seismic excitations.

Estimating the maximum pounding force for steel tall buildings in proximity subjected to wind

  • Tristen Brown;Ahmed Elshaer;Anas Issa
    • Wind and Structures
    • /
    • 제39권1호
    • /
    • pp.47-69
    • /
    • 2024
  • Pounding of structures may result in considerable damages, to the extent of total failure during severe lateral loading events (e.g., earthquakes and wind). With the new generation of tall buildings in densely occupied locations, wind-induced pounding becomes of higher risk due to such structures' large deflections. This paper aims to develop mathematical formulations to determine the maximum pounding force when two adjacent structures come into contact. The study will first investigate wind-induced pounding forces of two equal-height structures with similar dynamic properties. The wind loads will be extracted from the Large Eddy Simulation models and applied to a Finite Element Method model to determine deflections and pounding forces. A Genetic Algorithm is lastly utilized to optimize fitting parameters used to correlate the maximum pounding force to the governing structural parameters. The results of the wind-induced pounding show that structures with a higher natural frequency will produce lower maximum pounding forces than those of the same structure with a lower natural frequency. In addition, taller structures are more susceptible to stronger pounding forces at closer separation distances. It was also found that the complexity of the mathematical formula from optimization depends on achieving a more accurate mapping for the trained database.

Investigation of divergence tunnel excavation according to horizontal offsets between tunnels

  • Hong, Soon-Kyo;Oh, Dong-Wook;Kong, Suk-Min;Lee, Yong-Joo
    • Geomechanics and Engineering
    • /
    • 제21권2호
    • /
    • pp.111-122
    • /
    • 2020
  • In most cases in urban areas, construction of divergence tunnel should take into account proximity to existing tunnel in operation. This inevitably leads to deformation of adjacent structures and surrounding ground. Preceding researches mainly dealt with reinforcing of the diverging section for the stability including the pillar. This has limitations in investigating the interactive effects between existing structures and surrounding ground due to the excavation of the divergence tunnel. In this study, the complex interactive behavior of pile, the operating tunnel, and the surrounding ground according to horizontal offsets between the two adjacent tunnels was quantitatively analyzed based on conditions diverged from operating tunnel in urban areas. The effects on ground structures confirmed by analyzing the ground surface settlements, pile settlements, and the axial forces of the pile. The axial forces of lining in operating tunnel investigated to estimate their impact on existing tunnel. In addition, in order to identify the deformation of the surrounding ground, the close range photogrammetry applied to the laboratory model test for confirming the underground displacements. Two-dimensional finite element numerical analysis was also performed and compared with the results. It identified that the impact of excavating a divergence tunnel decreased as the horizontal offset increased. In particular, when the horizontal offset was larger than 1.0D (D is the diameter of operating tunnel), the impact on existing structures further reduced and the deformation of surrounding ground was concentrated at the top of the divergence tunnel.

Optimum location for the belt truss system for minimum roof displacement of steel buildings subjected to critical excitation

  • Kamgar, Reza;Rahgozar, Peyman
    • Steel and Composite Structures
    • /
    • 제37권4호
    • /
    • pp.463-479
    • /
    • 2020
  • Currently, there are many lateral resisting systems utilized in resisting lateral loads being produced in an earthquake. Such systems can significantly reduce the roof's displacement when placed at an optimum location. Since in the design of tall buildings, the minimum distance between adjacent buildings is important. In this paper, the critical excitation method is used to determine the best location of the belt truss system while calculating the minimum required distance between two adjacent buildings. For this purpose, the belt truss system is placed at a specific story. Then the critical earthquakes are computed so that the considered constraints are satisfied, and the value of roof displacement is maximized. This procedure is repeated for all stories; i.e., for each, a critical acceleration is computed. From this set of computed roof displacement values, the story with the least displacement is selected as the best location for the belt truss system. Numerical studies demonstrate that absolute roof displacements induced through critical accelerations range between 5.36 to 1.95 times of the San Fernando earthquake for the first example and 7.67 to 1.22 times of the San Fernando earthquake for the second example. This method can also be used to determine the minimum required distance between two adjacent buildings to eliminate the pounding effects. For this purpose, this value is computed based on different standard codes and compared with the results of the critical excitation method to show the ability of the proposed method.