• Title/Summary/Keyword: two adjacent structures

검색결과 233건 처리시간 0.025초

Performance of an isolated simply supported bridge crossing fault rupture: shake table test

  • Xiang, Nailiang;Yang, Huaiyu;Li, Jianzhong
    • Earthquakes and Structures
    • /
    • 제16권6호
    • /
    • pp.665-677
    • /
    • 2019
  • This study utilizes large-scale shake table test to investigate the seismic performance of an isolated bridge with lead rubber bearings crossing an active fault. Two transverse restraining systems with and without shear keys are tested by applying spatially varying ground motions. It is shown that the near-fault span exhibits larger bearing displacement than the crossing-fault span. Bridge piers away from the fault rupture are more vulnerable than those adjacent to the fault rupture by attracting more seismic demand. It is also verified that the shear keys are effective in restraining the bearing displacement on the near-fault span, particularly under the large permanent ground displacement.

Clinical Applications of Dual-Energy CT

  • Saira Hamid;Muhammad Umer Nasir;Aaron So;Gordon Andrews;Savvas Nicolaou;Sadia Raheez Qamar
    • Korean Journal of Radiology
    • /
    • 제22권6호
    • /
    • pp.970-982
    • /
    • 2021
  • Dual-energy CT (DECT) provides insights into the material properties of tissues and can differentiate between tissues with similar attenuation on conventional single-energy imaging. In the conventional CT scanner, differences in the X-ray attenuation between adjacent structures are dependent on the atomic number of the materials involved, whereas in DECT, the difference in the attenuation is dependent on both the atomic number and electron density. The basic principle of DECT is to obtain two datasets with different X-ray energy levels from the same anatomic region and material decomposition based on attenuation differences at different energy levels. In this article, we discuss the clinical applications of DECT and its potential robust improvements in performance and postprocessing capabilities.

Performance indicator of the atmospheric corrosion monitor and concrete corrosion sensors in Kuwait field research station

  • Husain, A.;Al-Bahar, Suad Kh.;Salam, Safaa A. Abdul
    • Smart Structures and Systems
    • /
    • 제17권6호
    • /
    • pp.981-994
    • /
    • 2016
  • Two field research stations based upon atmospheric corrosivity monitoring combined with reinforced concrete corrosion rate sensors have been established in Kuwait. This was established for the purpose of remote monitoring of building materials performance for concrete under Kuwait atmospheric environment. The two field research sites for concrete have been based upon an outcome from a research investigation intended for monitoring the atmospheric corrosivity from weathering station distributed in eight areas, and in different regions in Kuwait. Data on corrosivity measurements are essential for the development of specification of an optimized corrosion resistance system for reinforced concrete manufactured products. This study aims to optimize, characterize, and utilize long-term concrete structural health monitoring through on line corrosion measurement and to determine the feasibility and viability of the integrated anode ladder corrosion sensors embedded in concrete. The atmospheric corrosivity categories supported with GSM remote data acquisition system from eight corrosion monitoring stations at different regions in Kuwait are being classified according to standard ISO 9223. The two nominated field sites where based upon time of wetness and bimetallic corrosion rate from atmospheric data where metals and rebar's concrete are likely to be used. Eight concrete blocks with embeddable anodic ladder corrosion sensors were placed in the atmospheric zone adjacent to the sea shore at KISR site. The anodic ladder corrosion rate sensors for concrete were installed to provide an early warning system on prediction of the corrosion propagation and on developing new insights on the long-term durability performance and repair of concrete structures to lower labor cost. The results show the atmospheric corrosivity data of the environment and the feasibility of data retrieval of the corrosion potential of concrete from the embeddable sets of anodic ladder corrosion sensors.

모듈방식 FRP 선체를 위한 Moulding-In 개념 기반의 접합 이음부 개발에 관한 연구 (On the Development of Bonded Joints for Modular FRP Hulls using Moulding-In Concept)

  • 정한구
    • 한국전산구조공학회논문집
    • /
    • 제30권6호
    • /
    • pp.531-539
    • /
    • 2017
  • 전통적인 FRP 선체 제작에는 mould가 요구되며, mould의 높은 제작비용은 FRP 선박 제작자에게 비용부담을 주고 있다. 이를 극복하기 위한 방안으로 강선 건조에서 사용되는 블록 혹은 모듈 방식의 제작기법에 착안한 modular construction 방안이 제시되었다. 이 제작방안을 FRP 선체에 효율적으로 적용하기 위해서는 설계 및 제작 측면에서 간략하면서도 구조적 안정성을 갖는 접합 이음부 개발이 이루어져야 한다. 따라서, 본 논문에서는 모듈방식의 FRP 선체 제작을 위해 moulding-in 개념을 기반으로 한 경제적인 접합 이음부 개발에 관한 연구를 수행하였다. FRP 샌드위치 판을 대상으로 step, scarf-step 그리고 scarf 이음부 형상을 갖는 moulded-in을 수지주입식진공성형 공정에 도입하여 성공적으로 접합된 FRP 샌드위치 판을 제작하였다. 이에 대해 구조적 안정성 평가를 목적으로 인장 및 4점 굽힘 시험 그리고 유한요소해석을 수행하였다. 시험과 해석결과에 대한 비교 연구를 통해 본 연구에서 개발된 접합 이음 내용이 모듈방식의 FRP 선체 제작에 적용 가능함을 확인할 수 있었다.

Cyanide- and Phenoxo-Bridged Heterobimetallic Fe(III)-Mn(III) Coordination Polymer: Synthesis, Crystal Structures and Magnetic Properties

  • Zhang, Daopeng;Kong, Lingqian;Li, Yueyun;Wang, Ping;Chen, Xia
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권9호
    • /
    • pp.2684-2688
    • /
    • 2014
  • Two two-dimensional cyanide- and phenoxo-bridged heterometallic M(II)-Mn(III) (M = Ni, Pd) coordination polymers $\{[Mn(saltmen)]_4[Ni(CN)_4]\}(ClO_4)_2{\cdot}CH_3OH{\cdot}H_2O$ (1) and $\{[Mn(saltmen)]_4[Pd(CN)_4]\}(ClO_4)_2{\cdot}CH_3CN{\cdot}H_2O$ (2) ($saltmen^{2-}$ = N,N'-(1,1,2,2-tetramethylethylene)bis(salicylideneaminato)dianion) have been obtained by using $K_2[M(CN)_4]$ as building blocks and a salen-tpye Schiff-base manganese(III) compound as assembling segment. Single X-ray analysis reveals their isostrutural cyanide-bridged $MMn_4$ pentanuclear cationic structure. The four Schiff base manganese units of the pentanuclear entity are self-complementary through the phenoxo oxygen atoms from the neighboring complex, therefore forming cyanide- and phenoxo-bridged 2D sheet-like structure. Investigation over magnetic susceptibilities reveals the overall ferromagnetic coupling between the adjacent Mn(III) ions bridged by the phenoxo oxygen atoms with J = 2.13 and $2.21cm^{-1}$ for complexes 1 and 2, respectively.

A simplified method for estimating fundamental periods of pylons in overhead electricity transmission systems

  • Tian, Li;Gao, Guodong;Qu, Bing
    • Earthquakes and Structures
    • /
    • 제19권2호
    • /
    • pp.119-128
    • /
    • 2020
  • In seismic design of a pylon supporting transmission lines in an overhead electricity transmission system, an estimation of the fundamental periods of the pylon in two orthogonal vertical planes is necessary to compute the seismic forces required for sizing pylon members and checking pylon deflections. In current practice, the fundamental periods of a pylon in two orthogonal vertical planes are typically obtained from eigenvalue analyses of a model consisting of the pylon of interest as well as some adjacent pylons and the transmission lines supported by these pylons. Such an approach is onerous and numerically inconvenient. This research focused on development of a simplified method to determine the fundamental periods of pylons. The simplified method is rooted in Rayleigh's quotient and is based on a single-pylon model. The force vectors that can be used to generate the shape vectors required in Rayleigh's quotient are presented in detail. Taking three pylons selected from representative overhead electricity transmission systems having different design parameters as examples, the fundamental periods of the chosen pylons predicted from the simplified method were compared with those from the rigorous eigenvalue analyses. Result comparisons show that the simplified method provides reasonable predictions and it can be used as a convenient surrogate for the tedious approach currently adopted.

H.264 기반 다시점 비디오 부호화를 위한 양자화 계수 결정 방법 (Quantization Parameter Selection Method For H.264-based Multi-view Video Coding)

  • 박필규;호요성
    • 한국통신학회논문지
    • /
    • 제32권6C호
    • /
    • pp.579-584
    • /
    • 2007
  • 최근 다시점 비디오를 효율적으로 부호화하기 위해 다양한 시공간 예측 구조들이 제안되었다. 이 논문에서는 다시점 비디오 부호화 예측 구조에서 각 GOP의 첫 화면들에 삽입되는 B$_{ANC}$ 화면을 위해 양자화 계수를 결정하는 방법을 제안한다. 각 시점의 영상 화질을 균일하게 유지하고 전체적인 부호화 효율을 높이기 위해 B$_{ANC}$ 화면의 양자화 계수를 적응적으로 조절하며, 인접한 두 참조화면의 비트-왜곡 비용값을 사용하여 상관도를 추정하고 이를 이용하여 B$_{ANC}$ 화면의 양자화 계수를 결정한다. 이 논문에서 제안한 방법을 다시점 비디오 참조 예측 구조에 적용하여 부호화한 결과, 0.09$\sim$0.16 dB 정도의 PSNR 개선을 얻었다.

Multi-objective durability and layout design of fabric braided braking hose in cyclic motion

  • Cho, J.R.;Kim, Y.H.
    • Steel and Composite Structures
    • /
    • 제25권4호
    • /
    • pp.403-413
    • /
    • 2017
  • The fabric braided braking hose that delivers the driver's braking force to brake cylinder undergoes the large deformation cyclic motion according to the steering and bump/rebound motions of vehicle. The cyclic large deformation of braking hose may give rise to two critical problems: the interference with other adjacent vehicle parts and the micro cracking stemming from the fatigue damage accumulation. Hence, both the hose deformation and the fatigue damage become the critical issue in the design of braking hose. In this context, this paper introduces a multi-objective optimization method for minimizing the both quantities. The total length of hose and the helix angles of fabric braided composite layers are chosen for the design variables, and the maximum hose deformation and the critical fatigue life cycle are defined by the individual single objective functions. The trade-off between two single objective functions is made by introducing the weighting factors. The proposed optimization method is validated and the improvement of initial hose design is examined through the benchmark simulation. Furthermore, the dependence of optimum solutions on the weighting factors is also investigated.

석회화치성낭의 두 증례보고 (Two cases report of Calcifying Odontogenic Cyst)

  • 이병도;이완;팽준영;이준;최문기;손현진
    • Imaging Science in Dentistry
    • /
    • 제39권3호
    • /
    • pp.169-173
    • /
    • 2009
  • The calcifying odontogenic cyst (COC) is a rare disorder of the jaws and shows various radiographic features. The purpose of this study is to describe the different radiographic appearances of 2 cases of COC. Case 1 was located in the posterior maxilla extending into maxillary sinus, showing unilocular radiolucency with a well-defined margin. Cortical bone expansion and thinning were prominent. Root resorption of adjacent teeth was apparent. Case 2 showed unilocular radiolucency with a calcified material. Calcification was supposed to be dystrophic dental hard structures, detected at the periphery of the lesion. Ghost cell and proliferation of ameloblastoma-like tissues were common features for these two lesions on histopathological findings. This reports presented common and atypical radiographic features of the COC.

  • PDF

Frequency variation in construction stages and model validation for steel buildings

  • Aras, Fuat
    • Steel and Composite Structures
    • /
    • 제22권3호
    • /
    • pp.647-662
    • /
    • 2016
  • This study aims to monitor the variation of modal frequencies of steel buildings during their construction sequence. In this respect, construction of a steel building is followed by vibration based measurements. The monitored building is a three-story educational building within a building group whose structural system consists of steel moment resisting steel frames and eccentric braces. Five different acceleration measurements in two perpendicular directions are taken on five different construction stages, starting from the erection of the columns and beams ending with the completion of the construction. The recorded measurements are transferred into frequency domain and the dominant frequencies for each case have been determined. The change in the dominant frequencies is evaluated with the existing construction stages and performed constructional works between the stages. The last measurement, performed on the building in service, revealed the first two dominant frequencies as mutual in X and Y direction, showing that these dynamic modes are torsional modes. This result is investigated by numerical analysis performed with finite element model of the building constructed for design purpose. Lower frequencies and different mode shapes are determined from numerical analysis. The reason of lower frequencies is discussed and the vibration survey is extended to determine the effects of an adjacent building. The results showed that the building is in strong relation with an adjoining building in spite of a designed construction joint.