• Title/Summary/Keyword: turn-off switching

Search Result 313, Processing Time 0.034 seconds

Special quality research by pulse transformer stabilization by high tension output module of medical ultra series laser II (산부인과용 $CO_2$ 연속형 레이저의 고압출력 모듈에 따른 펄스트랜스 안정화 특성연구(II))

  • Kim, Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.1
    • /
    • pp.49-56
    • /
    • 2007
  • Various kind of laser had been used on addition to endoscope for obstetrics and gynecology, gas laser such as CO2 laser had been used mainly much in laparoscope surgical operation mainly Thermal effect of beam displays other result different component parts of cellular tissue and different close of a marketplace of laser beam and priority solidification of temperature increase consists in cellular tissue, and cutting or carbonization process happens and evaporation by breakdown of cellular tissue happens more than $300^{\circ}$. <중략> Ostabilization of pulse transformer by high tension output module of CO2analog laser for obstetrics and gynecology that accomplish marks of honor kind switching and accuracy is required, and stabilize with laser output applying Turn-off in existent hard switching forward converter, on city happened switching damage, damage increase of output diode station recovery special quality, parasitism shock, design and result that manufacture, brought result that improve than existing product. Will be bought to get into superior result if supplement as systematic late.

  • PDF

A Simple Structure of Zero-Voltage Switching (ZVS) and Zero-Current Switching (ZCS) Buck Converter with Coupled Inductor

  • Wei, Xinxin;Luo, Ciyong;Nan, Hang;Wang, Yinghao
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1480-1488
    • /
    • 2015
  • In this paper, a revolutionary buck converter is proposed with soft-switching technology, which is realized by a coupled inductor. Both zero-voltage switching (ZVS) of main switch and zero-current switching (ZCS) of freewheeling diode are achieved at turn on and turn off without using any auxiliary circuits by the resonance between the parasitic capacitor and the coupled inductor. Furthermore, the peak voltages of the main switch and the peak current of the freewheeling diode are significantly reduced by the coupled inductor. As a result, the proposed converter has the advantages of simple circuit, convenient control, low consumption and so on. The detailed operation principles and steady-state analysis of the proposed ZVS-ZCS buck converter are presented, and detailed power loss analysis and some simulation results are also included. Finally, experimental results based on a 200-W prototype are provided to verify the theory and design of the proposed converter.

Traction IGBT Modules Design Issues and Precautions (전철용 IGBT 모듈 설계연구)

  • Gopal, Devarajan;Lho, Young-Hwan;Kim, Yoon-Ho
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1853-1859
    • /
    • 2008
  • IGBT modules are designed for low loss, rugged for all environments and user friendly. Low on state saturation voltage with high switching speed is the primary concerns. In this paper selection of IGBT, module ratings and characteristics are discussed. The IGBT design topic of protection against over voltage and over current are covered. Emphasis on turn off switching, short circuit switching and necessary precautions are dealt. Selection of IGBT device, gate drive power, and its lay out considerations are covered in detail.

  • PDF

A Study on the Reliability and Optimal Control of Half-Bridge Inverter for Induction Beating System (유도 가열용 Half-Bridge 인버터 시스템의 신뢰성 향상 및 최적제어에 관한 연구)

  • 유상봉
    • Journal of the Korean Professional Engineers Association
    • /
    • v.33 no.1
    • /
    • pp.94-105
    • /
    • 2000
  • The purpose of this paper is to obtain the improved reliability and optimal control of the half-bridge inverter for induction heating system. Parasitic inductance components within the inverter circuit for induction heating including the loss-less turn-off snubber capacitor considerably affect stable operation and noise level of the system. This paper analyzes the effect of the inductance in detail and presents a new snubber configuration suitable for the half-bridge inverter to effectively reduce it. In the half-bridge inverter for induction heating the capacity of the loss-less snubber capacitor determines the switching losses because the zero voltage turn-on switching is used. However, the increase of the capacitor is limited by the system specifications, so that it is not easy work to reduce the switching loss. To effectively overcome the limitation, this paper introduces an active auxiliary resonant circuit suitable for the half-bridge inverter circuit, which operates actively according to the variation of load condition. It is also one of the most important study issues for the half-bridge inverter driven induction heater that the development of optimal control scheme considering varied load condition should be achieved. The control strategy ensures a very stable operation of overall inverter system and zero voltage turn-on switching irrespective of sensitive load parameter variations, in particular, even under the non-magnetic materials.

  • PDF

Interleaved ZVS Resonant Converter with a Parallel-Series Connection

  • Lin, Bor-Ren;Shen, Sin-Jhih
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.528-537
    • /
    • 2012
  • This paper presents an interleaved resonant converter with a parallel-series transformer connection in order to achieve ripple current reduction at the output capacitor, zero voltage turn-on for the active switches, zero current turn-off for the rectifier diodes, less voltage stress on the rectifier diodes, and less current stress on the transformer primary windings. The primary windings of the two transformers are connected in parallel in order to share the input current and to reduce the root-mean-square (rms) current on the primary windings. The secondary windings of the two transformers are connected in series in order to ensure that the transformer primary currents are balanced. A full-wave diode rectifier is used at the output side to clamp the voltage stress of the rectifier diode at the output voltage. Two circuit modules are operated with the interleaved PWM scheme so that the input and output ripple currents are reduced. Based on the resonant behavior, all of the active switches are turned on under zero voltage switching (ZVS), and the rectifier diodes are turned off under zero current switching (ZCS) if the operating switching frequency is less than the series resonant frequency. Finally, experiments with a 1kW prototype are described to verify the effectiveness of the proposed converter.

A Novel Step-up AC-DC Converter with PFC by Discontinuous Current Control (전류불연속 제어에 의한 새로운 PFC 승압형 AC-DC 컨버터)

  • Kim, Choon-Sam;Shim, Jae-Sun;Kim, Chun-Sik;Lee, Hyun-Woo;Kwak, Dong-Kurl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.142-148
    • /
    • 2006
  • In this paper, authors propose a novel step-up AC-DC converter operated with power factor correction (PFC) and with high efficiency. The proposed converter behaves with discontinuous current control (DCC) of input current. The input current waveform in the proposed converter is got to be a discontinuous sinusoid form in proportion to magnitude of at input voltage under the constant duty cycle switching. Therefore, the input power factor is nearly unity and the control method is simple. In the general DCC converters, the switching devices are turned-on with the zero current switching (ZCS). But turn-off of the switching devices is done at the maximum current. To achieve a soft switching at turn-off, the proposed converter uses a new partial resonant circuit, which results in the very low switching loss and the high efficiency of converter.

Characteristic analysis of linear switched reluctance motor according to switching condition (스위칭 조건에 따른 리니어 스위치드 릴럭턴스 전동기의 특성 해석)

  • Jang, Seok-Myeong;Park, Ji-Hoon;You, Dae-Joon;Sung, Ho-Kyung;Cho, Han-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.725-726
    • /
    • 2008
  • This paper deals with characteristic analysis of Linear Switched Reluctance Motor (LSRM) according to switching condition. When approved current in each phase by decided position, we made sure current and voltage according to turn-on, turn-off. In dynamic simulation of LSRM, through an experiment, we decided turn-on position of inductance profile. Also, we presented dynamic characteristic analysis model which is consisted at motor and sensor signal part, etc., and substitute circuit constant that get using magnetic equivalent circuit method, we confirmed current and voltage waveform.

  • PDF

A novel ZVS interleaved totem-pole PFC converter with reduced circulating current and diode reverse recovery current (순환전류와 다이오드 역회복 전류가 작은 인터리빙 방식의 새로운 ZVS 토템폴 PFC 컨버터)

  • ;Choe, U-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.189-191
    • /
    • 2018
  • This paper introduces a novel ZVS interleaved totem-pole PFC with the reduced circulating current and the reverse recovery current of the diodes. With the help of a simple auxiliary inductor, both ZVS turn-on of the main switches and soft turn-off of the body diodes can be achieved. In the proposed totem-pole PFC topology since the switching losses and the reverse recovery losses can be significantly reduced, the typical Si MOSFETs can be employed. In addition the circulating current is reduced by adjusting the switching frequency. The proposed PFC topology can be a low cost solution to achieve high efficiency in high power PFC applications. The validity and the feasibility of the proposed topology is verified by the experimental results with a 3.3kW interleaved totem-pole PFC converter.

  • PDF

Novel Zero-Current-Transition PWM DC/DC Converters (새로운 Zero-Current-Transition PWM DC/DC 컨버터)

  • 이민광;이동윤;현동석
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.2
    • /
    • pp.79-85
    • /
    • 2001
  • In this paper, a novel Zero-Current-Transition (ZCT) technique, which provides Zero-Current-Switching (ZCS) turn-off of the main switch, the main diode and the auxiliary switch, is presented. The proposed auxiliary circuit consists of minimum elements only one auxiliary switch, resonant inductor and resonant capacitor. Also the reduced di/dt, which is obtained by resonant inductor, helps soft turn-on of the main switch. Besides, to eliminate the additional conduction loss and current stress on main switch, a topological variation was performed. The theoretical analysis and the operation principle of the new ZCT techniques are described in detail with a boost converter as an example. To verify the validity of the proposed ZCT techniques, the simulation and the experiment were performed under 1kW output power and 100kHz switching frequency.

  • PDF

An improved Commutation Cell for PWM Converter (PWM 컨버터를 위한 향상된 ZVZCS Commutation Cell)

  • 유승희
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.388-391
    • /
    • 2000
  • In this paper a modified ZVZCS(zero-voltage/zero-current switching) commutation cell with minimum additional components which provides soft switching at both turn-on and turn-off of main and auxiliary switches as well as diodes in PWM converters is presented. The proposed soft-switching technique is suitable for not only minority but also majority carrier semiconductor devices. The auxiliary switch of the proposed ZVZCS commutation cell is in parallel with the main switch and therefore there is no current stress on the main switch and diode. The operation principles of the proposed ZVZCS commutation cell are theoretically analyzed using the PWM boost converter topology as an example. Theoretical analysis simulation and experimental results verify the validity of the PWM boost converter topology with the proposed ZVZCS commutatioin cell.

  • PDF