고속철도 터널에서 발생하는 파동현상에 관한 충격파관의 연구(1) - 압축파의 특성에 대하여 - (Study of Shock Tube for Wave Phenomenon in High Speed Railway Tunnel(1) - On the characteristics of Compression Wave -)

  • 김희동
    • 대한기계학회논문집
    • /
    • 제18권10호
    • /
    • pp.2686-2697
    • /
    • 1994
  • When a railway train enters a tunnel at high speed, a compression wave is formed in front of the train and propagates along the tunnel. The compression wave subsequently emerges from the exit of the tunnel, which causes an impulsive noise. In order to estimate the magnitudes of the noises and to effectively minimize them, the characteristics of the compression wave propagating in a tunnel must be understood. In the present paper, the experimental and analytical investigations on the attenuation and distortion of the propagating compression waves were carried out using a model tunnel. This facility is a kind of open-ended shock tube with a fast-opening gate valve instead of a general diaphragm. One-dimensional flow model employed in the present study could appropriately predict the strength of the compression wave, Mach number and flow velocity induced by the compression wave. The experimental results show that the strength of a compression wave decreases with the distance from the tunnel entrance. The decreasing rate of the wave strength and pressure gradient in the wave is strongly dependent on the strength of the initial compression wave at the tunnel entrance.

미기압파 저감을 위한 고속전철 열차-터널 조건의 근사최적설계 (Approximate Optimization of High-speed Train Shape and Tunnel Condition to Reduce the Micro-pressure Wave)

  • 김정희;이종수;권혁빈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1023-1028
    • /
    • 2004
  • A micro-pressure wave is generated by the high-speed train which enters a tunnel, and it causes explosive noise and vibration at the exit. It is known that train speed, train-tunnel area ratio, nose slenderness and nose shape mainly influence on generating micro-pressure wave. So it is required to minimize it by searching optimal values of such train shape factors and tunnel condition. In this study, response surface model, one of approximation models, is used to perform optimization effectively and analyze sensitivity of design variables. Owen's randomized orthogonal array and D-optimal Design are used to construct response surface model. In order to increase accuracy of model, stepwise regression is selected. Finally SQP(Sequential Quadratic Programming) optimization algorithm is used to minimize the maximum micro-pressure wave by using built approximation model.

  • PDF

제트 홴 방식 환기시스템을 사용하는 터널의 환기량에 영향을 주는 인자에 대한 수치해석 검토 (A Numerical Analysis on the Effect of Parameters for the Flow Rate through the Tunnel with Jet Fan Ventilating System)

  • 김사량;김기정;허남건;김영일
    • 설비공학논문집
    • /
    • 제14권7호
    • /
    • pp.567-574
    • /
    • 2002
  • In the present study, ventilation flow rates and pressure rises through a road tunnel are simulated numerically using CFD with the various conditions such as roughness height, swirl angle of jet fan, entrance and exit effect and hub to tip ratio. By using a modified wall function, friction factor can be predicted under 10% of error with respect to the Moody chart for the circular pipe flow and 15%, for the present tunnel. For more precise design, the effects of the swirl angle and hub to tip ratio of jet fan, which is not included in the theoretical equation of pressure rise by jet fan are necessary to be considered.

Overview of Flow Diagnosis in a Shock Tunnel

  • Kim, Ikhyun;Lee, Sungmin;Park, Gisu;Lee, Jong Kook
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권3호
    • /
    • pp.425-435
    • /
    • 2017
  • In this work, an overview of flow diagnosis in a shock tunnel is made by means of using established techniques that are easy to setup, economical to arrange, and simple to measure. One flow condition was considered having Mach number of 6 at the nozzle-exit, regarded as freestream. Measured aerothermodynamic data such as shock wave speed, wall static and total pressures, surface heat flux, and shock stand-off distance ahead of test model showed good agreement with calculation. This study shows an overall procedure of flow diagnosis in a shock tunnel in a single manuscript. Outcomes are thought to be useful in the field of education and also in a preliminary stage of high-speed vehicle design and tests, that need to be performed within a short time with decent accuracy.

고속도로터널의 붕락유형과 원인 분석 (Analysis of Collapse Shape and Cause in the Highway Tunnel)

  • 김낙영;김성환;정형식
    • 한국터널지하공간학회 논문집
    • /
    • 제2권3호
    • /
    • pp.13-24
    • /
    • 2000
  • 본 논문에서는 고속도로터널의 붕락형태와 원인분석, 보강방법에 대하여 다루었다. 고속도로터널의 붕락형태를 분석해 보면 3가지 유형으로 분류된다. 지반풍화로 인해 터널붕락이 지표면까지 함몰된 경우 35%, 불리한 암반절리로 인한 터널내 국부적인 쐐기형 암반블럭 붕락의 경우 50%, 터널굴진방향과 미끄럼면의 교차로 인해 터널내 침하가 발생한 경우 15%의 비율로 조사되었고 터널붕락이 발생된 위치는 입출구 40m 이내와 입출구와 인접한 계곡부에서 85%, 비상주차대과 본선접속부에서 15% 발생되었다. 고속도로터널에서 발생한 붕락을 파괴개념으로 분석하면 활동파괴가 83%이상을 차지하는 것으로 분석되었다.

  • PDF

고속철도 터널에서 발생하는 파동현상에 관한 충격파관의 연구(2)-압축파의 감쇠와 비선형효과- (Study of Shock Tube for Wave Phenomenon in High Speed Railway Tunnel(II)-attenuation and Nonlinear Effect of Compression Waves-)

  • 김희동;송미일태
    • 대한기계학회논문집
    • /
    • 제19권8호
    • /
    • pp.1972-1981
    • /
    • 1995
  • As a railway train enters a tunnel at high speed, a compression wave is formed in front of the train and propagates along the tunnel. The compression wave subsequently emerges from the exit of the tunnel, which causes an impulsive noise. The impulsive noise is closely related to the pressure gradient of the compression wave propagating the tunnel. In order to investigate the characteristics of the compression waves, in the present study an experiment was made using a shock tube. The results show that the strength of a compression wave decreases with the distance from the tunnel entrance and the nonlinear effect of compression wave appears to be significant if strength of the initial compression wave is greater than 7 kPa. Furthermore if the wave pattern is known, attenuation of the compression wave propagating in a tunnel can be reasonably predicted by a theoretical equation considering viscous action and heat transfer in boundary layer.

터널 내 대기오염물질의 공간분포 예측 (Prediction of spatial distribution of air pollutants within tunnel)

  • 박일건;홍민선;김범석;강호근
    • 한국터널지하공간학회 논문집
    • /
    • 제14권6호
    • /
    • pp.607-616
    • /
    • 2012
  • 지속적인 터널 건설의 증가는 터널 내 대기질 관리에 대한 필요성을 점증시키고 있어 측정 및 모델 모사를 통한 터널 내 대기질 거동에 대한 연구를 수행하였다. 남산1호 터널 입구와 출구의 $CO_2$ 농도차는 250 ppm~400 ppm으로 출구쪽이 높았으며 환기를 안 하는 차량 내부의 농도는 외부에 비해 200 ppm~300 ppm 낮게 측정되었다. 교통량이 적을 시 터널 내 유속은 빨라지며 일정한 농도 구배를 나타내고, 교통량이 증가하면 일정치 않은 농도 구배를 나타내는 것으로 나타났다.

고속철도 터널 입구후드에 관한 수치해석적 연구 (Numerical Study on High-Speed railway Tunnel Entrance Hood)

  • 김희동;김동현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 창립기념 춘계학술대회 논문집
    • /
    • pp.604-611
    • /
    • 1998
  • High-speed railway trains entering and leaving tunnels generate finite amplitude pressure wave which propagate back and forth along the tunnels, reflecting at the open ends of the tunnels and at other discontinuities such as ventilation shafts and the train themselves. In present day railways, the magnitudes of the pressure waves are much too small to cause structual damage, but they are a serious potential source of aural discomport for passengers on unsealed trains. Almost always do the pressure waves propagating along the tunnels lead to a hazardous impulse noise near the exit portal of the tunnel. In order to alleviate such undesirable phenomena, some control strategies have been applied to the compression wave propagating inside the tunnel. The objective of the current work is to investigate the effect of tunnel entrance hoods on the entry compression wave at the vicinity of the tunnel entrance. Three types of entrance hoods were tested by the numerical method using the characteristics of method for a wide range of train speeds. The results show that the maximum pressure gradient of compression wave can be considerably reduced by the tunnel entrance hood. Desirable hood shape for reduction of the pressure transients and impulse noise was found to be of abrupt type hood with its cross-sectional area 2.5times the tunnel area.

  • PDF

고속주행시 철도터널내 공기압 특성에 관한 기초연구 - 미기압(MPW)을 중심으로 (A study on the characteristics for aerodynamics at high speed in railway tunnels - focused on the micro pressure wave)

  • 김효규;최판규;유지오
    • 한국터널지하공간학회 논문집
    • /
    • 제16권2호
    • /
    • pp.249-260
    • /
    • 2014
  • 열차가 고속으로 터널을 진입할 때 압축파가 발생하게 된다. 이 압축파가 터널 출구부에 도달하면 일부는 외부로 방출되고 일부는 팽창파의 형태로 반사되어 터널내부로 전파된다. 이러한 파는 충격파의 형태로 외부로 방출되는데, 이를 미기압(micro pressure wave)이라고 한다. 미기압파는 터널 출구부에 소음 및 진동문제를 일으키며, 이 현상이 클수록 민가 및 주변 유리창에 손상과 거주자의 불안을 일으키는 원인이 된다. 따라서 고속철도 건설을 위해서는 미기압에 대한 대책과 이에 대한 예측이 필요한 실정이다. 이에 본 연구는 운영중인 터널에서의 미기압 측정사례와 터널내 압력기울기에 대한 수치해석을 통하여, 차량의 전두부 형상 및 터널 갱구부 형상에 따른 영향을 분석하였다. 그 결과로, 본 연구에서는 미기압파의 강도를 예측하는 방법을 제시하였으며, 이를 통해서 터널 연장과 단면적에 따른 미기압 강도를 해석하였다.

고속철도의 터널입구 형상변황에 따른 압력파동 현상에 관한 수치적 연구 (Numerical Study on the Effects of Pressure Wave Propagation for Tunnel Entrance Shape Change in High-Speed Railways)

  • 목재균;백남욱;유재석;최윤호
    • 한국자동차공학회논문집
    • /
    • 제5권2호
    • /
    • pp.50-59
    • /
    • 1997
  • When a front head of train enters a tunnel at a high speed, compression wave is generated at tunnel entrance due to the confinement effect and propagated along the tunnel with sound of speed. The propagated compression wave is reflected at tunnel exit due to abrupt pressure change at passage. The reflected wave is expansion pressure wave. And when the rear head of train goes through the tunnel entrance, another expansion pressure wave is generated and propagated along the tunnel. The pressure drop occurs seriously around train when the two expansion pressure waves come cross on train in the tunnel. In order to reduce the pressure drop, the compression wave front must be controlled because the intensity and magnitude of pressure drop is nearly proportional to that of compression wave at tunnel entrance. This study relates to reduction of the pressure wave gradient with respect to tunnel entrance shape change with various kind of angle and rounding. The results show characteristics of wave propagation in tunnel, usefulness of characteristic curve to estimate proper time domain size in numerical study and measuring time in actual experiment. Also rounding is contributed to improve pressure wave front even if its radius is very small at tunnel entrance. In order to improve of pressure wave front at tunnel entrance, proper angle is prefered to rounding with big radius and an angle of around 14$^{\circ}$ is recommended according to this simulations, And it is expected to reduce additional pressure drop in tunnel when the location and the size of the internal space for attendant equipment are considered in advance.

  • PDF