• 제목/요약/키워드: tube plate

검색결과 498건 처리시간 0.04초

Improving buckling response of the square steel tube by using steel foam

  • Moradi, Mohammadreza;Arwade, Sanjay R.
    • Structural Engineering and Mechanics
    • /
    • 제51권6호
    • /
    • pp.1017-1036
    • /
    • 2014
  • Steel tubes have an efficient shape with large second moment of inertia relative to their light weight. One of the main problems of these members is their low buckling resistance caused from having thin walls. In this study, steel foams with high strength over weight ratio is used to fill the steel tube to beneficially modify the response of steel tubes. The linear eigenvalue and plastic collapse FE analysis is done on steel foam filled tube under pure compression and three point bending simulation. It is shown that steel foam improves the maximum strength and the ability of energy absorption of the steel tubes significantly. Different configurations with different volume of steel foam and composite behavior is investigated. It is demonstrated that there are some optimum configurations with more efficient behavior. If composite action between steel foam and steel increases, the strength of the element will improve, in a way that, the failure mode change from local buckling to yielding.

원심성형법으로 제조한 고온초전도 튜브의 특성 분석 (Characteristics of HTS tube fabricated by centrifugal forming process)

  • 장건익;박용민
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.211-215
    • /
    • 2000
  • Bi-2212 HTS tube was fabricated by CFP(Centrifugal Forming Process). Slury was prepared in the mixing ratio of 8:2 between powder and binder and ball-milled for 24 hrs. Slurry was initially charged into the rotating mold with 300${\sim}$450 rpm and heated at the temperature ranges of 840${\sim}$860$^{\circ}$C for partial melting to finally obtain a uniformly textured tube shape. It was observed the plate-like grains with more than 20 ${\mu}$m were well oriented along the rotating axis and the measured T$_c$ was around 67K. In this paper we will discuss and analyze the tube characteristics depending on many different processing parameters such as, powder composition, binder mixing ratio between powder and binder, motor speed, heating temperature and etc.

  • PDF

An Experimental Study of the Airside Performance of Slit Fin-and-Tube Heat Exchangers under Dry and Wet Conditions

  • Chang, Keun-Sun;Long, Phan-Than
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권1호
    • /
    • pp.7-14
    • /
    • 2009
  • Water condensate accumulated on the surface of a fin-and-tube heat exchanger significantly affects its thermal and hydraulic performances. The purpose of this study is to investigate the effects of condensate retention on the air-side heat transfer performance and flow friction for various flow and geometric conditions. Total of twelve samples of slit and plate fin-and-tube heat exchangers are tested under dry and wet conditions. The thermal fluid measurements are made using a psychrometric calorimeter. Frontal air velocity varies in the range from 0.7 m/s to 1.5 m/s. Using the experimental data, presented are heat transfer coefficients in terms of Colburn j-factors and friction factors, and these data are compared with the existing correlations.

설계 조건에 따른 7mm 직경 핀-관 열교환기의 성능비교 (Performance Comparison of 7mm Fin-Tube Heat Exchangers for Various Design Conditions)

  • 장근선;김혁;홍석률;김영재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.633-638
    • /
    • 2006
  • This study presents the air side heat transfer and friction characteristics of fin-tube heat exchangers with various fin types. A total of 8 samples of heat exchangers are tested. Fin patterns tested are slit, louver and plate fins. Each fin type has three cases of number of tube rows(N=1, 2, 3) and two different fin pitches. The results are plotted in terms of Colburn j-factor and friction factor f with respect to Reynolds number in the range of 200 to 510.

  • PDF

Free vibration analysis of a laminated trapezoidal plate with GrF-PMC core and wavy CNT-reinforced face sheets

  • Yingqun Zhang;Qian Zhao;Qi Han;N. Bohlooli
    • Steel and Composite Structures
    • /
    • 제48권3호
    • /
    • pp.275-291
    • /
    • 2023
  • This paper has focused on presenting vibration analysis of trapezoidal sandwich plates with 3D-graphene foam reinforced polymer matrix composites (GrF-PMC) core and FG wavy CNT-reinforced face sheets. The porous graphene foam possessing 3D scaffold structures has been introduced into polymers for enhancing the overall stiffness of the composite structure. Also, 3D graphene foams can distribute uniformly or non-uniformly in the plate thickness direction. The effective Young's modulus, mass density and Poisson's ratio are predicted by the rule of mixture. In this study, the classical theory concerning the mechanical efficiency of a matrix embedding finite length fibers has been modified by introducing the tube-to-tube random contact, which explicitly accounts for the progressive reduction of the tubes' effective aspect ratio as the filler content increases. The First-order shear deformation theory of plate is utilized to establish governing partial differential equations and boundary conditions for trapezoidal plate. The governing equations together with related boundary conditions are discretized using a mapping-generalized differential quadrature (GDQ) method in spatial domain. Then natural frequencies of the trapezoidal sandwich plates are obtained using GDQ method. Validity of the current study is evaluated by comparing its numerical results with those available in the literature. It is explicated that 3D-GrF skeleton type and weight fraction, carbon nanotubes (CNTs) waviness and CNT aspect ratio can significantly affect the vibrational behavior of the sandwich structure. The plate's normalized natural frequency decreased and the straight carbon nanotube (w=0) reached the highest frequency by increasing the values of the waviness index (w).

닭의 추백리병에 관한 연구 I. 추백리 진단에 있어서 혈청응집과 Agar-gel 침강반응과의 비교 시험 (Studies on Diagnosis for Pullorum Disease Comparative Experiments for the Diagnosis of Pullorum Disease by Tube Agglutination and Agar-gel Precipitin Tests with Chicken Sera)

  • 최재윤;이시영;이창구
    • 대한수의학회지
    • /
    • 제10권2호
    • /
    • pp.1-5
    • /
    • 1970
  • In these studies the efficracy of plate, tube agglutination and agar-gel precipitin test were compared for the detection of pullorum infected chickens. From all the chickens showing positive reaction in agar-gel precipitin test, Salmonella pullorum organisms were isolated.

  • PDF

중공롤러의 절단면 형상변화에 따른 변형거동 특성해석 (Characteristic Analysis of Displacement Behavior of Hollow Rollers with Cross Sectional Area Profiles)

  • 정준기;김청균
    • 한국가스학회지
    • /
    • 제19권4호
    • /
    • pp.55-61
    • /
    • 2015
  • 본 연구에서는 여러 가지의 절단면 형상과 하중지지 용량을 높이기 위해 원판을 설치한 중공롤러의 변위거동 특성을 유한요소법으로 해석하였다. FEM 해석결과에 의하면, 중공롤러의 절단면 형상은 외측튜브, 중간튜브, 내측튜브와 이들 튜브들 사이를 연결하기 위해 X형 또는 Y형 컬럼을 설치한 경우는 중공롤러의 중간부에서 발생하는 최대 변위량을 줄여주는 효과가 있다. 여기에 중공롤러의 중간부 두께를 30~40mm 갖는 원판을 설치할 경우는 중공롤러의 최대 변위량을 줄이는데 효과가 크다는 해석결과를 제시하였다. 본 연구에서는 원통롤러의 전체 중량에 연계된 최대 변위량 비율을 고찰한 최적설계 데이터를 제하였다. FEM 해석결과에 의하면, 중공롤러에서 발생하는 최대 변위량과 전체 중량의 비율을 줄인 설계모델로는 4, 5와 6번을 추천할 수 있다.

흡수관 형상과 일사 각도에 따른 진공관형 태양열 집열기의 성능 변화 (Thermal Performance Variations of Glass Evacuated Tube Solar Collectors Depending on the Absorber Shape and the Incidence Angle of Solar Ray)

  • 김용;서태범;강용혁
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.659-668
    • /
    • 2005
  • The thermal performances of glass evacuated tube solar collectors are numerically investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are numerically investigated. Dealing with only collecting tube, the effects of not only the shape of the absorber tube but also the incidence angle of solar irradiation on the thermal performance of the collector are studied because the energy obtained by the absorber can be varied according to the incidence angle of solar radiation. However, the solar irradiation consists of the beam radiation as well as the diffuse radiation. Also, in actual system, the interference of solar irradiation and heat transfer interaction between the tubes should be considered. Therefore, this study considered these effects is carried out experimentally and numerically. The accuracy of the numerical model is verified by experiments. The result shows that the thermal performance of the absorber used a plate fin and U-tube is about $25\%$ better than those of the other models.

냉장고용 핀-튜브 증발기의 착상 성능해석에 관한 연구 (Numerical Analysis on the Frosting Performance of a Fin-tube Evaporator for a Refrigerator)

  • 이무연;이호성;장용희;김용찬
    • 대한기계학회논문집B
    • /
    • 제32권4호
    • /
    • pp.307-316
    • /
    • 2008
  • The objective of this study is to provide numerical and experimental data that can be used to investigate the performance characteristics of a flat plate fin-tube evaporator in household and commercial refrigerators under frosting conditions. Computer simulations with variations of operating conditions such as air inlet temperature, relative humidity, and geometries were performed to find out optimal design parameters of a fin-tube evaporator for household and commercial refrigerators. The tube-by-tube method was used in the simulation and the frost growth model was considered under frosting conditions. The developed analytical model predicted the decreasing rates of heat transfer capacity and air flow rate ratio within ${\pm}$10% compared to the experimental results for a refrigerator under real operating conditions. As a result, the frost thickness at $3^{\circ}C$ & 80% is increased 40% than that of $-3^{\circ}C$ & 80%, and the frost thickness at $3^{\circ}C$ & 90% is increased 30% than that of $3^{\circ}C$ & 60%. Accordingly, the operating time of the evaporator in the refrigerator was reduced with the increase of the decreasing rate of air flow rate ratio at each condition.

평판형 태양열 집열판의 집열관 온도분포 특성 (The Characteristics of Temperature Distributions for Flat Tube Type Solar Collector Type)

  • 모종근;배철환;정효민;정한식
    • 태양에너지
    • /
    • 제19권3호
    • /
    • pp.85-91
    • /
    • 1999
  • This study represented experimental research on the flat-plate solar collector. The heat performances were measured the tube array surface temperature by thermal-couple. The solar collector($W{\times}H$) of $580{\times}1100$, various tilt angles of 30, 45, 60 degree and the internal tube number of 4, 6, 8, 10(ea) were utilized in the present investigation. It is found that the thermal concentration is higher as the tilt angle become larger and the solar tubes are more and more. In this stuby obtained results of following: The array of tubes in collector has the best nice in that the number of tube is eight and the tilt angle is 60 degree. The collect energy by each tube array shown high value by increase the number of tubes and tilt angles. In addition to, the collect energy depends on by the tilt angle than the number of tube.

  • PDF