• Title/Summary/Keyword: tube internal

Search Result 586, Processing Time 0.025 seconds

Magnetic Abrasive Polishing for Internal Face of STS Tube using Sludge Abrasive Grain

  • Kim, Hee-Nam;Soh, Dea-Wha;Hong, Sang-Jeen;Lee, Byung-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.3
    • /
    • pp.128-132
    • /
    • 2005
  • In this paper, we have investigated the characteristics of the magnetic abrasive using sludge on polishing of internal finishing of seamless stainless steel (STS304) tube applying magnetic abrasive polishing. Either white alumina (WA) or green carborundum (GC) grain was used to resin sludge at a low temperature, and the sludge of magnetic abrasive powder was synthesized and crushed into 200 meshes. Surface roughness was measured before and after polishing, and more than $40\%$ of improvement of surface roughness was achieved when WA grain was used under a specific condition. Even though some degree of surface roughness due to deeper scratches still exist, but the result showed a prospective magnetic abrasive polishing using sludge with WA or GC grains.

Magnetic Abrasive Polishing for Internal Face of Seamless Stainless Steel Tube Using Sludge Abrasive Grain (슬러지 연마입자를 이용한 이음매 없는 스테인리스강 튜브내면의 자기연마)

  • Kim, Hee-Nam;Yun, Yeo-Kwon;Kim, Sang-Baek;Choi, Hee-Sung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.6
    • /
    • pp.151-157
    • /
    • 2004
  • In this paper deals with behavior of the magnetic abrasive using sludge on polishing characteristics in a new internal finishing of seamless stainless steel tube applying magnetic abrasive polishing. The magnetic abrasive using sludge-abrasive grain WA and GC used to resin bond fabricated low temperature. And sludge of magnetic abrasive powder fabricated that sludge was crused into 200 mesh. The previous research have made an experiment in the static state the movement of magnetic abrasive grain is nevertheless in the dynamic state. In this paper, We could have investigated into the changes of the movement of magnetic abrasive grain. In reference to this result, we could have made the experiment which is set under the condition of the magnetic flux density, polishing velocity according to the form of magnetic brush.

Magnetic Abrasive Polishing for Internal Face of Seamless Stainless Steel Tube using Sludge Abrasive Grain

  • Kim, Hee-Nam
    • Journal of the Speleological Society of Korea
    • /
    • no.78
    • /
    • pp.23-27
    • /
    • 2007
  • In this paper, we have investigated the characteristics of the magnetic abrasive using sludge on polishing of internal finishing of seamless stainless steel tube applying magnetic abrasive polishing. Either white alumina grain was used to resin sludge at a low temperature, and the sludge of magnetic abrasive powder was synthesized and crushed into 200 meshes. Surface roughness was measured before and after polishing, and more than 40% of improvement of surface roughness was achieved when grain was used under a specific condition. Even though some degree of surface roughness due to deeper scratches still exist, but the result showed a prospective magnetic abrasive polishing using sludge with white alumina grains.

Investigation on circular and octagonal concrete-filled double skinned steel tubular short columns under axial compression

  • R, Manigandan;Kumar, Manoj;Shedge, Hrishikesh N.
    • Steel and Composite Structures
    • /
    • v.44 no.1
    • /
    • pp.141-154
    • /
    • 2022
  • This paper describes the experimental and numerical investigation on circular and octagonal CFDST short columns under concentric loading to study their responses to various internal circular steel tube sizes by the constant cross-sectional dimensions of the external circular and octagonal steel tube. The non-linear finite element analysis of circular and octagonal CFDST columns was executed using the ABAQUS to forecast and compare the axial behavior influenced by the various sizes of internal circular steel tubes. The study shows that the axial compressive strength and ductility of circular and octagonal CFDST columns were significantly influenced by inner steel tubes with the strengths of constituent materials.

Performance Analysis of R744 (Carbon Dioxide) Transcritical Refrigeration System Using Internal Heat Exchanger (내부 열교환기를 이용한 R744용 초임계 냉동사이클의 성능 분석)

  • Son, Chang-Hyo;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.459-465
    • /
    • 2009
  • This paper considers the influence of internal heat exchangers to the efficiency of a refrigerating system. These internal heat exchangers(liquid-suction or suction-line heat exchangers) can, in some cases, yield improved system performance while in other cases they degrade system performance. A steady state mathematical model is used to analysis the performance characteristics of refrigeration system with internal heat exchanger. The influence of operating conditions, such as gas cooler pressure and evaporation temperatures, superheat in the evaporator and temperature of gas cooler outlet, to optimal dimensions of the heat exchanger is also analyzed in the paper. The main results were summarized as follows : the mass flowrate of R744, inner diameter tube and length of internal heat exchanger, and effectiveness have an effect on the cooling capacity, compressor work and RCI(Relative capacity index) of this system. With a thorough grasp of these effect, it is necessary to design the R744 compression refrigeration cycle using internal heat exchanger.

CFT seismic reinforcement method using diaphragm pre-assembled ㄷ-shaped column (다이어프램 선 조립 ㄷ형태 기둥을 이용한 CFT내진보강공법)

  • Woo, Jong-Yeol;Shin, Seung-Hun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.151-152
    • /
    • 2022
  • When reinforcing an existing building with the Concrete Filled Tube(CFT) structure, it is impossible to form a diaphragm inside with the existing method. Therefore, in this study, a construction method was proposed so that the internal diaphragm could be welded on four sides by using a slot to transmit force.

  • PDF

A Report on Three Cases of Acupuncture Needles Found Remaining in Patients' Bodies (체내에서 침이 발견된 사례 보고)

  • Yang, Na-Rae;Kim, Mi-Kyung;Choi, Dong-Jun;Han, Chang-Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.32 no.1
    • /
    • pp.144-151
    • /
    • 2011
  • Objectives : To report the cases of forgotten needles found in the patients' bodies since Dong-guk University Ilsan Hospital opened, and arouse considerable attention to prevent recurrence. Methods : Oriental medical doctors in the hospital has applied acupuncture on patients' bodies in case of need, and the other staffs removed the needles after treatment. Results : All the patients in the cases had cerebrovascular disease with paralysis, aphasia, cognitive disorder and disturbance of consciousness as well as dysphagia requiring gastrotomy tube and dysfunction of respiration requiring tracheal cannula. The pathways the acupuncture needles were passing through are presumed to be transtracheal via the hole of tracheal cannula in two cases, and transgastrointestinal via mouth or the opening of gastrotomy tube. The needle was excreted with stool without any harm to the patient in the latter case, while the impact of the needles on the respiratory system or thorax of the patients in the former two cases is ambiguous. The hospital has taken some measures to prevent recurrence. Conclusions : There are not a few at high-risk of occurrence of forgotten needles that might induce medical problems among patients in oriental medical clinics or hospitals. Authors expect this report arouses all the people involved in the whole procedure of acupuncture treatment, including oriental medical doctors, nurses, nurse-assistants and caregivers considerable attentions to the possible occurrence and risk of forgotten needles.

A Case of Ovarian Hyperstimulation Syndrome with Massive Pleural Effusion (다량의 흉수를 동반한 난소 과자극 증후군 1례)

  • Park, Hyeong-Kwan;Kim, Yu-Il;Hwang, Jun-Hwa;Jang, Il-Gweon;Kim, Yung-Chul;Lee, Yu-Il;Park, Kyung-Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.3
    • /
    • pp.684-691
    • /
    • 1997
  • 1be ovarian hyperstimulation syndrome is a rare but serious complication of ovulation induction therapy with gonadotropin. The clinical manifestations are generalized edema, ascites with pleural effusion and may become life-threatening in severe cases. The pathophysiology is still unknown, therefore, the treatment should be symptomatic and conservative. We report a case of severe OHSS with massive right pleural effusion in excess of ten liters after human menopausal gonadotropin therapy because of secondary infertility. Fluid and electrolyte imbalances were corrected and albumin was administered. A right chest tube was placed for a total of sixteen days, draining eleven liters of pleural effusion totally, resulting a dramatic decrease of pleural effusion and improvement of symptoms.

  • PDF