Investigation Between Gas in Oil Analysis and the Source of Trouble in Transformer (변압기 절연유 가스분석과 고장원인 검토)

  • Kweon Dong-Jin;Kwak Joo-Sik;Eun Jong-Young;Min Byeong-Moon;Yu Dong-Gyon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.8
    • /
    • pp.343-349
    • /
    • 2005
  • The gas in oil analysis of transformer is the most widely used technology for diagnosis of transformer in the world. It has brought excellent results to prevention of transformer failure. The criteria for maintenance and judgement, however, is still required continuous supplement to improve the accuracy of the diagnosis on the basis of accumulated data of gas analysis and investigations in the transformer In this study, the relationship between the detection rate of the defects and the source of troubles are analyzed according to the investigation in the transformer, which was conducted by KEPCO in 2004. As a result, the validity of the criteria being used at present was examined thoroughly.

On-line Test Equipment for Cable Joint by RF Sensing (RF 감지 방식 on-line 케이블 접속재 진단)

  • 이왕하;이성희;정희돈;김덕규;이동영
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.11
    • /
    • pp.661-667
    • /
    • 2003
  • It has little possibility that a cable causes any problem in electric power facilities. But when a trouble occurs in cable or cable joint, the damage is very severe. The main causes of the cable defections are bad cable making procedure, poor cable operation and deterioration according to the years. There are some cases to have potential problems due to many cable connection points, because of short length of cable, especially in 154㎸ system. In this study, novel method to measure partial discharge in cable joints is proposed and the effectiveness and the reliability of the proposed method is shown through experiment results of field.

The Driving Method of Power Switching Device Using Pizoelectric Transformer (전력 Switching 소자를 압전트랜스로 구동하는 방법)

  • Hwang, Min-Kyu;Lee, Sang-Kyun;Lee, Jae-Choon
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2458-2460
    • /
    • 1998
  • To drive motor or heating machine, it needs the electric power system like the apparatus of inverter. This electric power system obviously comprises power switching devices and drivers to run them. And this system has the topology comprised one/many arm(s), - each arm has high side switching device and low side switching device. Transformer, photocoupler, and HVIC having functions of isolation and level shift which are important thing to drive high side switching device are used as component of drivers in conventional apparatus. Piezoelectric transformers are proposed in this paper, and applied to drive high side swiching device. Through experiments, the possiblities of driving high side switching device are presented and the problems are mooted concurrently. But, we also consider a counterplan for solving the mooted trouble issues.

  • PDF

Stabilization of Modified Deceleration Mode for Improvement of Low-energy Ion Implantation Process (저 에너지 이온 주입의 개선을 위한 변형된 감속모드 이온 주입의 안정화 특성)

  • 서용진;박창준;김상용
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.3
    • /
    • pp.175-180
    • /
    • 2003
  • As the integrated circuit device shrinks to the deep submicron regime, the ion implantation process with high ion dose has been attracted beyond the conventional ion implantation technology. In particular, for the case of boron ion implantation with low energy and high dose, the stabilization and throughput of semiconductor chip manufacturing are decreasing because of trouble due to the machine conditions and beam turning of ion implanter system. In this paper, we focused to the improved characteristics of processing conditions of ion implantation equipment through the modified deceleration mode. Thus, our modified recipe with low energy and high ion dose can be directly apply in the semiconductor manufacturing process without any degradation of stability and throughput.

A Study on Gate Trigger Current of SCR (SCR 게이트 전류의 변화특성에 관한 연구)

  • Seong, Houng-Su;Won, Hak-Jai;Han, Seung-Mun;Ha, Jeong-Hoon;Park, Ho-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1333-1335
    • /
    • 2000
  • In order to turn on the SCR gate, trigger signal source have to provide appropriate gate current and voltage under the gate rating based on the characteristic of SCR, the nature of load and power. It will be essential design factors such as trigger source impedance, trigger signal occurring, signal time width and turn off conditions. Also minimum gate trigger current is changed with the deterioration of SCR. SCR, which is needed large gate trigger current absolutely, is very important for SCR characteristic test because it causes unstable output in the misfile or makes a trouble to pulse trigger circuits. This paper shows scheme to test the performance of SCR with the precision analyzing mechanism and the changing trend of minimum gate current under the trigger conditions.

  • PDF

Changes of Recloser's TC Curve for the Improvement of Distribution Line Protection Coordination (배전선로 보호협조 개선을 위한 리클로져 TC커브 변경)

  • Lee, Jung-Ho;Ha, Bok-Nam;Cho, Ham-Hun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.964-966
    • /
    • 1998
  • The TC curve of recloser which used in KEPCO's distribution line is a little different in a pattern with the TC curve of sub-station OCR. So it sometimes fails in protection coordination. And the recloser sometimes does mis-open/close owing to the inrush current of CB reclosing when a fault occurred on the source-side of the recloser. The mis-open/close is another trouble maker. This Paper Present a new delay TC curve of recloser which has the same pattern with the TC curve of OCR, and a new instantaneous TC curve of recloser which doesn't mal-function to the inrush current. In addition, this paper present another two TC curves for the serial positioning of 2 reclosers. So we accomplished the simple protection coordination of OCR-recloser-fuse.

  • PDF

Computational Analysis of Air Flow in a Spinner for Drying LCD Glass Panel (LCD 기판 세정건조용 스피너 설계를 위한 내부유동 해석)

  • Kwak Ho Sang;Lee Sang Woo;Lee Sanghyun;Kim Yong Bum
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.114-119
    • /
    • 2002
  • A numerical model is employed for design of a spinner device to dry the 5-th generation LCD glass panel. The turbulent flow in a spinner is driven by rotation of a large disk and suction by the exhaust system connected to vacuum chamber, which is simulated by using the FLUENT package. Based on numerical simulation, the required capacity of exhaust system is assessed. The effects of the presence of cover on the flow characteristics are examined. A computational trouble shooting is attempted to resolve the problem of panel rising which occurred in real experiments.

  • PDF

Development and Estimation of Hinge Belt Plate in Combination Type (복합형 힌지 벨트 플레이트의 개발과 평가)

  • Ha, Man-Kyung;Jun, Jae-Uhk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.5 no.4
    • /
    • pp.86-92
    • /
    • 2006
  • In the automobile and machine industry, Forming type conveyer system have problems in that hinge belt plate are stretched, produce a noise and get abrasion. they make the machine get out of order. we make hinge belt thicker for reducing the trouble. Thick hinge belt was stronger. But it was heavier. And it was hard to come up with buyer's expectations because the mold which makes the hinge belt have limit of strength, life cycle and size. So, we developed the machine welded each part of hinge belt plate.

  • PDF

Motion Characteristic Evaluation of Sliding Cover for High Speed Type Machine (Sliding cover의 고속 운동 특성 평가)

  • 강재훈;송준엽;박화영;이승우;황주호;이현용;이찬홍;이후상
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.446-449
    • /
    • 2002
  • Recently, advanced manufacturing system with high speed and intelligent have been developed for the betterment of machining ability. In this case, reliability prediction work with motion characteristic evaluation of sliding cover has also important roll from design procedure to manufacturing and assembly process. Accordingly in this study, H/W test -bed system for reliability evaluation of sliding cover has been developed to obtain proper reference data for design of new model, and also prevention trouble, quality and life cycle improvement extremely for advanced mother machinary.

  • PDF

The Effect of Solution Pressure to the Release in a Supercooled Aqueous Solution

  • Kang, Chae-Dong;Kim, Byung-Seon;Hong, Hi-Ki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.1
    • /
    • pp.25-31
    • /
    • 2009
  • Supercooled type ice storage system with aqueous solution (or water) may have trouble with non-uniform release of supercooling even though it contributes to the simplicity of system and ecological improvement. The non-uniform release increases the instability of the system because it may cause an ice blockage in pipe or cooling part. In order to suppress the release of the supercooling, a cooling experiment was tried to an ethylene glycol(EG) 3 mass% solution corresponding with pressurization. Also, the frequency ratio of the release of the supercooling was measured to the pressurization from 101 to 505 kPa. At results, the frequency ratio of supercooling release tends to decrease as the pressure of the aqueous solution increased in each cooling rate. Moreover, it tends to decrease as the cooling rate of the solution decreased in each pressure.