• 제목/요약/키워드: triple point of water

검색결과 15건 처리시간 0.028초

핵심국제비교용 물의 삼중점 셀 제작과 비교 실험 및 불확도 평가 (Construction and Comparison Measurement of Triple Point Water Cells for using Key Comparison and Evaluation of Uncertainty)

  • 강기훈;김용규;감기술
    • 센서학회지
    • /
    • 제13권2호
    • /
    • pp.114-120
    • /
    • 2004
  • The $Comet{\acute{e}}$ Consultatif de $Thermom{\acute{e}}trie$ (CCT) under the Comete International des Poids et Measures (CIPM) has decided to perform the Key Comparison (KC) for triple point of water cells used as a reference fixed point of thermometry at the 21st meeting held at November 2001, and the Bureau International des Poids et Measures (BIPM) has been nominated as a KC coordinator. According to the KC protocol prepared by BIPM, KRISS performed the KC experiments and evaluate a uncertainty. The temperature difference between two reference cells for the Korea Research Institute of Standards and Science (KRISS) and a test cell for the transfer standard, which is moved to BIPM was 0.024 mK and the combined standard uncertainty evaluated 0.055 mK.

초정밀 온도센서의 저온 영역 교정 장치 개발 (Development of the calibration system for very accurate thermometers at low temperatures)

  • 양인석;송창호;강기훈;김용규
    • 센서학회지
    • /
    • 제17권3호
    • /
    • pp.188-194
    • /
    • 2008
  • For the accurate calibrations of thermometers at low temperatures, triple points of oxygen and argon have been realized using sealed-type triple point cells. The triple points were realized with both adiabatic and continuous heating methods. The resistance of three capsule-type standard platinum resistance thermometers were measured at the triple points of oxygen, argon, mercury and water for the calibrations of these thermometers in the range from $-220^{\circ}C$ to $0.01^{\circ}C$. The extended uncertainty, with the coverage factor of 2, of the calibration in this range is smaller than 1 mK.

국가표준향상과 핵심국제비교를 위한 물의 삼중점 온도 측정 (Measurement of triple point of water temperature for improvement of the national standards and key comparison)

  • 양인석;이영희
    • 센서학회지
    • /
    • 제30권5호
    • /
    • pp.349-356
    • /
    • 2021
  • The Korea Research Institute of Standards and Science (KRISS), a National Metrology Institute of Korea, participated in the second-round of the international key comparison CCT-K7.2021 of triple point of water (TPW) cells. For the key comparison, three TPW cells, one of which had been used in the old CCT-K7 comparison, were assigned as the national standard of the TPW. The temperature difference (ΔT) between the average of the new and old national standards and ΔT between the new national standard and the transfer standard were measured. The comparison between the new and old national standards indicated a temperature increase of 69.5 µK after both the standards were corrected for the isotopic composition. The uncertainty of the national standard of the TPW temperature was 28 µK, and the uncertainty of ΔT was 14 µK. Three aspects of improvements in the new comparison compared to the old one were noted: (1) inclusion of two quartz cells in the national standard strengthens its long-term stability; (2) the standard deviation associated with the measurement of ΔT was reduced from 21 µK to 9.6 µK; (3) and the measured immersion profile of the TPW cells was much closer to the theoretically predicted dependence.

캡슐형 백금저항온도계 국제비교를 위한 네온, 산소, 아르곤, 수은 및 물의 삼중점 실현 (Realization of Triple Point of Ne, $O_2$, Ar, Hg and $H_2O$ for International Comparison of Capsule-type Platinum Resistance Thermometer)

  • 강기훈;김용규;감기술
    • 센서학회지
    • /
    • 제9권3호
    • /
    • pp.153-162
    • /
    • 2000
  • 평형수소 삼중점 (13.8033 K)부터 물의 삼중점 (273.16 K) 온도영역에서 표준온도계로 사용되는 캡슐형 백금저항온도계를 일차 교정하려면 고순도 물질의 삼중점이 사용된다. 국제온도눈금-1990 (ITS-90)을 확립하기 위해 평형수소, 네온, 산소, 아르곤, 수은 및 물의 삼중점 중에서 평형수소의 삼중점을 제외한 5 개의 삼중점을 실현하였다. 각각의 삼중점에서 국제비교용으로 채택된 캡슐형 백금저항온도계 2대의 저항을 2회 반복하여 측정하였다. 측정된 삼중점에서의 합성표준불확도는 A형 불확도와 B형 불확도 평가방법을 고려하여 산출하였다. 한국표준과학연구원에서 ITS-90에 정의된 네온, 산소, 아르곤, 수은 및 물의 삼중점에서의 합성표준불확도 추정결과는 각각 0.18 mK, 0.14 mK, 0.14 mK, 0.24 mK 및 0.11 mK 이었다.

  • PDF

표준백금저항온도계를 이용한 온도측정능력 상호비교 (Inter-comparison of temperature measurement capability using standard platinum resistance thermometers)

  • 감기술;강주식;이용재;이광복;김용규;박승남
    • 센서학회지
    • /
    • 제18권1호
    • /
    • pp.86-94
    • /
    • 2009
  • Temperature measurement capability was inter-compared using the transfer standard platinum resistance thermometers(SPRT) among four laboratories of KRISS. The transfer SPRTs were primarily calibrated at the triple point of water and Ga melting point, then used at inter-comparison experiment. Temperature difference of calibration value between temperature laboratory and length laboratory at $20^{\circ}C$ was -0.7 mK and +2.4 mK at density laboratory. Temperature measured near $20^{\circ}C$, $25^{\circ}C$ and $30^{\circ}C$ at fluid flow laboratory was deviated by $34.2{\sim}80.4\;mK$ from the calibration values of the transfer SPRT. Ga melting points was inter-compared among three laboratories, and the difference of Ga melting points against the standard Ga melting point of temperature laboratory were $0.03{\sim}0.54\;mK$ at length laboratory and 0.02 mK at density laboratory.

P.C.를 이용한 물과 증기 열물성치의 전산수식화에 관한 연구 (A Study on the Computerized Formulation of the Thermodynamic Properties of Water and Steam by Personal Computer)

  • 김경석;김원영;김경근;김용모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제16권4호
    • /
    • pp.88-101
    • /
    • 1992
  • Properties of water and steam are very important for the steam ejector CAD program as a subroutine and design of the Shell & Tube type steam condenser. Present formular programs are based on the Skeleton Table of ASME, and are able to calculate the thermodynamoc properties of water and steam throughout the whole of the region that extend in pressure from 0 to 1000 bar and temperature from 0.01 to 80$0^{\circ}C$. When comparing calculated values for specific volume, enthalpy and entropy with the Skeleton Table 1967 and IAPS Skeleton Table 1984, values fell well within tolerances specified except near the extremes of the range of interest at the critical point and triple point, where deviations were slightly larger.

  • PDF

A Study on Ice Slurry Production by Water Spray

  • Kim, Byeong-Sun;Lee, Yoon-Pyo;Yoon, Seong-Young;Lee, Jin-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.45-55
    • /
    • 1998
  • A theoretical and experimental study is performed to investigate the characteristics of ice slurry product. By diffusion-controlled evaporation model the possibility of ice slurry is theoretically anticipated. The water vapor evaporated from the surface of droplets is extracted continuously from the chamber by a vacuum pump. The droplet diameter is measured by silicon immersion method. The ice slurry is obtained by spraying droplets of ethylene glycol aqueous solution in the chamber where pressure is maintained under the triple point of water. The droplet with the diameter of 300 $\mu\textrm{m}$and the initial temperature of 2$0^{\circ}C$ was changed into ice particle within the chamber of 1.33m in height.

  • PDF

수분무에 의한 아이스 슬러리 생성에 관한 연구 (A study on ice-slurry production by water spray)

  • 김병선;이윤표;윤성영;이진호
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.134-143
    • /
    • 1997
  • A theoretical and experimental study has been performed to investigate the characteristics of ice-slurry product. By diffusion-controlled model, the possibility of ice slurry has been theoretically anticipated. The water vapor evaporated from the surface of droplets is extracted continuously from the chamber by a vacuum pump. The droplet diameter was measured by silion immersed method. The ice slurry has been obtained by spraying droplets of ethylene-glycol aqueous solution in the chamber where pressure is maintained under the triple point of water. The droplet of which the diameter is $300{\mu}m$, and the initial temperature is $20^{\circ}C$, was changed into ice particle within the chamber of which the height is 1.33m.

  • PDF

아토피 피부염의 발생시긱별 변화에 대한 경락학적 해석 (The Meridian Interpretation of Atopic Dermatitis Phases)

  • 조용주;김진주
    • 한방안이비인후피부과학회지
    • /
    • 제17권1호
    • /
    • pp.1-15
    • /
    • 2004
  • The different growth steps of human show the different energetic phenomenon such as the strength of triple energizer, the sale of extra meridian, and the stability of 12 meridians. So we have to understand the physiological and pathological phenomena on this point of view. Especially atopic dermatitis means the loss of adaptability under the lack of genuine energy. If you approach to this disease not with any perception of excess or deficiency of the human genuine energy but with simple symptom enumeration or partial diagnosis, it will be dangerous. So we must approach to this disease with more concrete and objective body-centered standard. Thus when we cure and diagnose infants with this disease, we should focus on stablizing the "Energy of Earth(土)" digestive ability, under the consideration of inducement to the enough "Byun-Jeung-Hu(變蒸候)" and the function of Triple Energizer. Through this process we can lead infants to the beginning equipment state(始全). Until 7 years old, we should stabilize the Link Vessel(維脈) by clarifying interior and exterior classification of Nutritive Element and Defensive Energy to control the child's energy of metal(金), water(水), wood(木) and fire(火) in the basis of the energy of earth(土). And also we should stabilize the Heel Vessel(?脈) through the Water and Fire complement each other to control the movements and to control sleep and awakening. Through this process, we can lead children to the basal equipment state(本全). After then, until adolescent phase, we should control 12 meridian and 8 extra meridian by leading vital function to be harmonized and prosperous on the basis of the meridian to reach the mature equipment state(旣全). Adult atopic dermatitis should be controlled through conciliation between meridian and internal organs by differentiating male from female.

  • PDF

백금저항온도센서를 이용한 국가교정기관의 교정능력 평가 및 실험방법 (Experimental method and evaluation of the calibration capability for the national calibration centers using the platinum resistance temperature sensors)

  • 감기술;유성호;김성민;이인식
    • 센서학회지
    • /
    • 제14권4호
    • /
    • pp.231-236
    • /
    • 2005
  • Calibration capability was evaluated using the reference-grade platinum resistance thermometer (PRT) in the temperature range of $-50^{\circ}C$ to $250^{\circ}C$ for the national calibration centers. The reference-grade PRT was calibrated at the several fixed points, which was composed by the freezing points of Sn, In, the melting point of Ga and the triple point of water and Hg, before and after the round-robin test (RRT) experiments. The temperature scale of reference-grade PRT was compared to the local standard PRT's using the system of the national calibration centers. $E_{n}$ values was calculated by the temperature difference between the reference-grade PRT and the local standard PRT, and the best measurement capability. Finally, the capability of the national calibration centers was evaluated by the $E_{n}$ values.