• 제목/요약/키워드: trigger wave

검색결과 47건 처리시간 0.026초

SS-OCT용 정현파 및 트리거 펄스 발생기 (Sine-wave and Trigger Pulse Generator for SS-OCT)

  • 엄진섭
    • 센서학회지
    • /
    • 제24권6호
    • /
    • pp.398-403
    • /
    • 2015
  • In this paper, the sine-wave and trigger pulse generator with capability of frequency high-resolution and time-variable trigger edge has implemented. It fulfills well the requirements for SS-OCT with frequency resolution of 1 Hz, frequency stability of ${\leq}{\pm}0.03Hz$ and time-variable trigger edge. Through its performance test applied to the wavelength swept laser, 90 nm, sweeping range and 10mW average optical power were obtained. This showes that the realized generator can replace the commercial high cost and high performance signal generators employed by current SS-OCT systems.

Development portable hair removal applies PET ($Pause^{10-90}$ and $Energy^{20-40}$ $Trigger^{1-7}$) function

  • Kim, Whi-Young
    • Journal of information and communication convergence engineering
    • /
    • 제7권2호
    • /
    • pp.223-230
    • /
    • 2009
  • For pulse trigger way and the energy injection rate according to PET ($Pause^{10-90}$ $Energy^{20-40}$ $Trigger^{1-7}$) function, indeed, human body condition, period of dormancy in this research about this back correctly adjustment possible and designed harmless micro carrying along style hair exclusion so that can design and manufacture and run special quality examination and Xenon flash lamp to crawl in human body. Because creating individual's skin model to do stable treatment by light transmission way by skin impedance and measure, must embody treatment special quality of most suitable that draw skin color, energy, wave length, approximately, transmission time, pulse delay etc. and want. Specially, saved standard of war treatment pulse modeling by skin impedance, and manufacture pulse modeling system of most suitable by skin subordinate, and embody suitable treatment pulse. Specially, embody as could do root of a hair exclusion being emitted in pulse form using multi wave length of 560nm, 590nm, 640nm, 755nm and embodied clinical data. If become research repletion furthermore little more, is seen that can approximate in commercialization.

근막통증증후군 환자에게 통증점 체외충격파 치료가 경추의 가동 범위, 통증, 근육의 기계적 특성에 미치는 영향 (Effects of Extracorporeal Shock Wave Therapy in Pain Point on Range of Motion, Pain and Mechanical Muscle Properties in Myofascial Pain Syndrome)

  • 정구영;윤태림;이준희
    • 한국전문물리치료학회지
    • /
    • 제28권1호
    • /
    • pp.53-58
    • /
    • 2021
  • Background: To evaluate whether extracorporeal shock wave therapy (ESWT) in the pain point is a more effective treatment than the trigger point for myofascial pain syndrome (MPS) of the upper trapezius. Objects: The purpose of this study was to compare the most effective areas when applying extracorporeal shock wave therapy. Methods: A total of 30 patients with MPS were randomly assigned to the trigger point in the ESWT (n = 15) and pain point ESWT (n = 15) groups. Interventions in both groups were performed in one session, i.e., 2,000 shocks with 1.5 bar intensity. Pain and function were assessed using the visual analog scale (VAS) and cervical range of motion (ROM) and based on mechanical muscle properties. Statistical analysis was performed using the repeated measures two-way analysis of variance to determine the significance probability between pre- and post-test. Results: Changes in mechanical muscle properties were not statistically significant between the two groups. However, VAS and cervical ROM showed statistically significant differences at pre- and post-intervention, regardless of the group (p < 0.05). Conclusion: Although no significant difference was observed in the intervention effect, applying an extracorporeal shock wave to the pain point rather than the pain trigger point should be considered in order to save time in effectively and accurately identifying the pain trigger point and site.

에너지 하베스팅 응용을 위한 진동 감지기가 있는 전파정류 회로 설계 (Design of a Full-Wave Rectifier with Vibration Detector for Energy Harvesting Applications)

  • 가학진;유종근
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 추계학술대회
    • /
    • pp.421-424
    • /
    • 2017
  • 본 논문에서는 진동 감지기가 있는 전파 정류 하베스팅 회로를 설계하였다. 설계된 회로는 진동 감지기와 능동다이오드를 통해 진동이 감지될 때에만 동작하며, 진동이 없을 때 비교기를 off시켜 $C_{STO}$에 저장된 에너지의 누설을 방지한다. 커패시터에 저장된 에너지는 레벨 변환기와 능동다이오드의 구동에 사용된다. 진동 감지기는 Hysteresis 기능이 있는 Schmitt Trigger와 피크검출기로 구현하였다. 제안된 회로는 $0.35{\mu}m$ CMOS 공정으로 설계하였으며, 모의실험을 통해 동작을 검증하였다. 설계된 에너지 하베스팅 회로의 칩 면적은 $590{\mu}m{\times}583{\mu}m$이다.

  • PDF

Pressure pain threshold and visual analogue scale changes in the high and low energy extracorporeal shock wave

  • Yang, You-Jin;Lee, Seung-Joon;Choi, Matthew
    • Physical Therapy Rehabilitation Science
    • /
    • 제3권2호
    • /
    • pp.142-147
    • /
    • 2014
  • Objective: This study aims to investigate high energy and low energy extracorporeal shockwave therapy (ESWT) and which one is more effective for shoulder pain. Design: Single blind randomized controlled trial. Methods: Fifty two subjects with upper trapezius (UT) trigger point (TrP) participated in this study. They were allocated to high energy (n=26) and low energy group (n=26). This study applies ESWT and investigates the changes of pressure pain threshold (PPT) and visual analogue scale (VAS). The high and low energy groups received focused piezo electric type ESWT 4 Hz, 1,000 pulses and 0.351 and $0.092mJ/mm^2$ respectively. Outcome measures of PPT and pain was measured by algometer and pain VAS. These measurements were performed before and after treatment. Results: The PPT value was significantly increased in both groups after treatment (p<0.05) and VAS scores were significantly decreased after treatment in both groups (p<0.05). However, there were no significant differences between groups. Conclusions: ESWT is an effective treatment for the application of the UT TrP. Although there were significant effects of extracorporeal shock wave therapy on PPT and VAS scores, there were no signficant differences between high and low energy extracorporeal shock wave therapy.

쌍방향 시동방식의 고속투입스위치 개발 (Development of the Spark-gap Switch with Dual Trigger System)

  • 김맹현;서윤택;박승재;박병락;고의석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권7호
    • /
    • pp.359-364
    • /
    • 2000
  • This paper is introducing a newly developed spark-gap switch with dual trigger system, into which the current from the voltage source is injected along with the test sequence during the synthetic testing of high voltage circuit-breaker. The currently-used spark gap switch is narrow in operating range due to the use of the method of triggering energy being injected by single way. As a result, the frequent happening of misoperation has greatly reduced the test quality and test efficiency and has required the cost of maintenance excessively. In this study, accordingly, in order to basically remove these problems, another triggering system is installed to the opposite direction on the existing triggering system; attaching the same time and the same rising time of pulse wave as on the existing system, so that at a comparatively trigger gap distance from the main electrode(the gap can be operated at 60% of self-break voltage, while at 80% in the current system), the main electrode has been enabled to be closed by the development of spark gap switch with dual trigger system.

  • PDF

FMCW 레이저 거리 측정기의 비선형성 보정 방법 (Nonlinearity Correction Method in FMCW Laser Range Finder)

  • 정수용;이성로;정민아;박창수
    • 한국통신학회논문지
    • /
    • 제38C권4호
    • /
    • pp.351-358
    • /
    • 2013
  • 본 논문에서는 연속파 주파수 변조(FMCW) 레이저 거리 측정기에서 주파수 변화의 비선형성을 보정하는 기술을 제안하였다. FMCW 기반의 레이저 거리측정기는 높은 거리 분해능을 위해 주파수 변화의 선형성이 요구되며, 비선형성이 존재할 경우 비트 신호의 주파수가 일정하지 않아 거리 측정 성능에 심각한 영향을 미치게 된다. 하지만 일반적으로 주파수 변조를 위해 사용하는 VCO(Voltage Controlled Oscillator)의 출력은 비선형적인 특성을 가지게 된다. 이와 같은 주파수 변화의 비선형성을 보정하기 위하여 본 논문에서는 보조 딜레이 구조를 사용하였다. 보조 딜레이 구조에서 생성되는 신호는 거리 정보를 가진 비트 신호와 동일한 변화율을 가지며, ADC(Analog to Digital Converter)의 Trigger 신호로 사용된다. 즉, 비트 신호의 주파수와 동일한 변화율을 가지는 신호를 Trigger로 사용하여 비트 신호를 샘플링 함으로 비선형성이 보정되어 일정한 비트 주파수를 얻을 수 있고, 따라서 정확한 거리 측정을 할 수 있게 된다. 이에 대한 성능을 검증하기 위해 실험을 수행하여 그 결과를 제시하였다. 제안한 방식에 의해 비성형성으로 인한 FMCW 레이저 거리 측정기의 측정 오차를 개선하여 시스템의 성능이 향상되는 것을 확인할 수 있었다.

심초음파용 실시간 심전도 QRS 검출 모듈에 관한 연구 (A Design of Real-Time QRS Detection in Physio-Module for Echocardiography)

  • 장원석;김남현;김응석;전대근
    • 전자공학회논문지SC
    • /
    • 제47권3호
    • /
    • pp.40-47
    • /
    • 2010
  • 본 연구는 심초음파에서 사용되는 실시간 심전도 QRS 검출성능 및 심전도 trigger 시간 지연 등의 생체신호측정모듈의 성능 개선을 확인하고자 하였다. 심초음파에서 사용되는 생체신호측정모듈의 심전도 QRS 검출에 대한 성능 평가 중에서 심전도 QRS 크기와 폭에 따른 검출성능, Tall T-wave 제거성능, 부정맥이 있는 심전도의 QRS 검출성능 및 Pacer pulse 검출성능은 심전도 국제 규격인 EC-13을 기준으로 성능을 비교 평가하였으며, QRS의 trigger 신호 지연 시간 및 기저선 복귀시간은 기존에 상용화되어 심초음파에 사용되고 있는 생체신호측정모듈의 성능과 비교 평가하였다. 본 연구에서는 위 4가지 항목은 국제규격인 EC-13 기준을 크게 만족하였으며, QRS의 trigger 신호 지연 시간은 심박수에 따라 17m~21ms 빠른 검출 결과를 보였으며 심전도 기저선 복귀시간도 1 beat 이상 빠른 결과를 보였다.

Event Trigger Generator for Gravitational-Wave Data based on Hilbert-Huang Transform

  • Son, Edwin J.;Chu, Hyoungseok;Kim, Young-Min;Kim, Hwansun;Oh, John J.;Oh, Sang Hoon;Blackburn, Lindy;Hayama, Kazuhiro;Robinet, Florent
    • 천문학회보
    • /
    • 제40권2호
    • /
    • pp.55.4-56
    • /
    • 2015
  • The Hilbert-Huang Transform (HHT) is composed of the Empirical Mode Decomposition (EMD) and the Hilbert Spectral Analysis (HSA). The EMD decomposes any time series data into a small number of components called the Intrinsic Mode Functions (IMFs), compared to the Discrete Fourier Transform which decomposes a data into a large number of harmonic functions. Each IMF has varying amplitude and frequency with respect to time, which can be obtained by HSA. The time resolution of the modes in HHT is the same as that of the given time series, while in the Wavelet Transform, Constant Q Transform and Short-Time Fourier Transform, there is a tradeoff between the resolutions in frequency and time. Based on the time-dependent amplitudes of IMFs, we develop an Event Trigger Generator and demonstrate its efficiency by applying it to gravitational-wave data.

  • PDF

Contrast-Enhanced Magnetic Resonance Imaging at True End-Diastole to Quantify Reproducible Transmural Extent of Myocardial Hyperenhancement

  • 최병욱;최규옥;김영진;정남식;임세중
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.44-44
    • /
    • 2003
  • To determine feasibility of contrast-enhanced MRI (co-MRI) at true end-diastole (ED) free from limitation of time for inversion-recovery and trigger window for quantifying transmural extent of infarction. 대상 및 방법: MRI was performed in 18 patients with myocardial infarction. Cine imaging and co-MRI with same registered slices in short axis were peformed. To allow true ED co-MRI, ECG synchronization should use two RR-intervals for one acquisition of a segment of k-space by setting the heart rate to half that of the true heart rate. Trigger delay time was adjusted to the RR-interval for imaging at ED and to the sum of RR-interval plus the time between R-wave and the end-systole (ES) determined in cine images for imaging at ES.

  • PDF