Sine-wave and Trigger Pulse Generator for SS-OCT (SS-OCT용 정현파 및 트리거 펄스 발생기)

  • Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.398-403
    • /
    • 2015
  • In this paper, the sine-wave and trigger pulse generator with capability of frequency high-resolution and time-variable trigger edge has implemented. It fulfills well the requirements for SS-OCT with frequency resolution of 1 Hz, frequency stability of ${\leq}{\pm}0.03Hz$ and time-variable trigger edge. Through its performance test applied to the wavelength swept laser, 90 nm, sweeping range and 10mW average optical power were obtained. This showes that the realized generator can replace the commercial high cost and high performance signal generators employed by current SS-OCT systems.

Development portable hair removal applies PET ($Pause^{10-90}$ and $Energy^{20-40}$ $Trigger^{1-7}$) function

  • Kim, Whi-Young
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.2
    • /
    • pp.223-230
    • /
    • 2009
  • For pulse trigger way and the energy injection rate according to PET ($Pause^{10-90}$ $Energy^{20-40}$ $Trigger^{1-7}$) function, indeed, human body condition, period of dormancy in this research about this back correctly adjustment possible and designed harmless micro carrying along style hair exclusion so that can design and manufacture and run special quality examination and Xenon flash lamp to crawl in human body. Because creating individual's skin model to do stable treatment by light transmission way by skin impedance and measure, must embody treatment special quality of most suitable that draw skin color, energy, wave length, approximately, transmission time, pulse delay etc. and want. Specially, saved standard of war treatment pulse modeling by skin impedance, and manufacture pulse modeling system of most suitable by skin subordinate, and embody suitable treatment pulse. Specially, embody as could do root of a hair exclusion being emitted in pulse form using multi wave length of 560nm, 590nm, 640nm, 755nm and embodied clinical data. If become research repletion furthermore little more, is seen that can approximate in commercialization.

Effects of Extracorporeal Shock Wave Therapy in Pain Point on Range of Motion, Pain and Mechanical Muscle Properties in Myofascial Pain Syndrome (근막통증증후군 환자에게 통증점 체외충격파 치료가 경추의 가동 범위, 통증, 근육의 기계적 특성에 미치는 영향)

  • Jung, Koo-Young;Yoon, Tae-Lim;Lee, Jun-Hee
    • Physical Therapy Korea
    • /
    • v.28 no.1
    • /
    • pp.53-58
    • /
    • 2021
  • Background: To evaluate whether extracorporeal shock wave therapy (ESWT) in the pain point is a more effective treatment than the trigger point for myofascial pain syndrome (MPS) of the upper trapezius. Objects: The purpose of this study was to compare the most effective areas when applying extracorporeal shock wave therapy. Methods: A total of 30 patients with MPS were randomly assigned to the trigger point in the ESWT (n = 15) and pain point ESWT (n = 15) groups. Interventions in both groups were performed in one session, i.e., 2,000 shocks with 1.5 bar intensity. Pain and function were assessed using the visual analog scale (VAS) and cervical range of motion (ROM) and based on mechanical muscle properties. Statistical analysis was performed using the repeated measures two-way analysis of variance to determine the significance probability between pre- and post-test. Results: Changes in mechanical muscle properties were not statistically significant between the two groups. However, VAS and cervical ROM showed statistically significant differences at pre- and post-intervention, regardless of the group (p < 0.05). Conclusion: Although no significant difference was observed in the intervention effect, applying an extracorporeal shock wave to the pain point rather than the pain trigger point should be considered in order to save time in effectively and accurately identifying the pain trigger point and site.

Design of a Full-Wave Rectifier with Vibration Detector for Energy Harvesting Applications (에너지 하베스팅 응용을 위한 진동 감지기가 있는 전파정류 회로 설계)

  • Ka, Hak-Jin;Yu, Chong-Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.421-424
    • /
    • 2017
  • This paper describes a full-wave rectifiers for energy harvesting circuit using vibration detector. The designed circuit operates only when the vibration is detected through the vibration detector and the active diode. When there is no vibration, the comparator is turned off to prevent leakage of energy stored in the $C_{STO}$. The energy stored in the capacitor is used to drive the level converter and the active diode. The energy stored in the capacitor is supplied to an active diode designed as an output power. The vibration detector is implemented with Schmitt Trigger and Peak Detector with Hysteresis function. The proposed circuit is designed in a CMOS 0.35um technology and its functionality has been verified through extensive simulations. The designed chip occupies $590{\mu}m{\times}583{\mu}m$.

  • PDF

Pressure pain threshold and visual analogue scale changes in the high and low energy extracorporeal shock wave

  • Yang, You-Jin;Lee, Seung-Joon;Choi, Matthew
    • Physical Therapy Rehabilitation Science
    • /
    • v.3 no.2
    • /
    • pp.142-147
    • /
    • 2014
  • Objective: This study aims to investigate high energy and low energy extracorporeal shockwave therapy (ESWT) and which one is more effective for shoulder pain. Design: Single blind randomized controlled trial. Methods: Fifty two subjects with upper trapezius (UT) trigger point (TrP) participated in this study. They were allocated to high energy (n=26) and low energy group (n=26). This study applies ESWT and investigates the changes of pressure pain threshold (PPT) and visual analogue scale (VAS). The high and low energy groups received focused piezo electric type ESWT 4 Hz, 1,000 pulses and 0.351 and $0.092mJ/mm^2$ respectively. Outcome measures of PPT and pain was measured by algometer and pain VAS. These measurements were performed before and after treatment. Results: The PPT value was significantly increased in both groups after treatment (p<0.05) and VAS scores were significantly decreased after treatment in both groups (p<0.05). However, there were no significant differences between groups. Conclusions: ESWT is an effective treatment for the application of the UT TrP. Although there were significant effects of extracorporeal shock wave therapy on PPT and VAS scores, there were no signficant differences between high and low energy extracorporeal shock wave therapy.

Development of the Spark-gap Switch with Dual Trigger System (쌍방향 시동방식의 고속투입스위치 개발)

  • Kim, Maeng-Hyeon;Seo, Yun-Taek;Park, Seung-Jae;Park, Byeong-Rak;Go, Ui-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.7
    • /
    • pp.359-364
    • /
    • 2000
  • This paper is introducing a newly developed spark-gap switch with dual trigger system, into which the current from the voltage source is injected along with the test sequence during the synthetic testing of high voltage circuit-breaker. The currently-used spark gap switch is narrow in operating range due to the use of the method of triggering energy being injected by single way. As a result, the frequent happening of misoperation has greatly reduced the test quality and test efficiency and has required the cost of maintenance excessively. In this study, accordingly, in order to basically remove these problems, another triggering system is installed to the opposite direction on the existing triggering system; attaching the same time and the same rising time of pulse wave as on the existing system, so that at a comparatively trigger gap distance from the main electrode(the gap can be operated at 60% of self-break voltage, while at 80% in the current system), the main electrode has been enabled to be closed by the development of spark gap switch with dual trigger system.

  • PDF

Nonlinearity Correction Method in FMCW Laser Range Finder (FMCW 레이저 거리 측정기의 비선형성 보정 방법)

  • Jung, Soo-Yong;Lee, Seong Ro;Jeong, Min A;Park, Chang-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.4
    • /
    • pp.351-358
    • /
    • 2013
  • We propose a correction method of nonlinear frequency sweep in an FMCW(Frequency Modulated Continuous Wave) laser range finder. FMCW laser range finder requires linear frequency sweep for high resolution, and nonlinear frequency sweep makes the system performance degrade. In general, VCO(Voltage Controlled Oscillator) which is a component used for frequency modulation in FMCW method has nonlinear property. To correct the nonlinear frequency sweep, we utilize an auxiliary delay structure for generating trigger signal of ADC(Analog to Digital Converter). Because the trigger signal has same rate of change with the beat signal, the nonlinearity of the beat signal can be corrected. the experimental results show that the proposed method effectively eliminates the nonlinear frequency sweep problem and enhances the system performance.

A Design of Real-Time QRS Detection in Physio-Module for Echocardiography (심초음파용 실시간 심전도 QRS 검출 모듈에 관한 연구)

  • Jang, Won-Seuk;Kim, Nam-Hyun;Kim, Eong-Sok;Jeon, Dae-Keun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.3
    • /
    • pp.40-47
    • /
    • 2010
  • In this study, we investigated the performance of real-time QRS complex detection algorithm in physio-module for echocardiography. The performance of QRS detection module in echocardiography was evaluated according to international standard, EC-13 and we compared with commercialized physio-module with QRS complex detection. In this study, we can get performance of QRS complex detection, pacer pulse detection, Tall t-wave rejection and arrhythmia detection within EC-13's criteria and we can get improved QRS trigger delay time and baseline wondering rejection times in compared with commercialized physio-module.

Event Trigger Generator for Gravitational-Wave Data based on Hilbert-Huang Transform

  • Son, Edwin J.;Chu, Hyoungseok;Kim, Young-Min;Kim, Hwansun;Oh, John J.;Oh, Sang Hoon;Blackburn, Lindy;Hayama, Kazuhiro;Robinet, Florent
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.55.4-56
    • /
    • 2015
  • The Hilbert-Huang Transform (HHT) is composed of the Empirical Mode Decomposition (EMD) and the Hilbert Spectral Analysis (HSA). The EMD decomposes any time series data into a small number of components called the Intrinsic Mode Functions (IMFs), compared to the Discrete Fourier Transform which decomposes a data into a large number of harmonic functions. Each IMF has varying amplitude and frequency with respect to time, which can be obtained by HSA. The time resolution of the modes in HHT is the same as that of the given time series, while in the Wavelet Transform, Constant Q Transform and Short-Time Fourier Transform, there is a tradeoff between the resolutions in frequency and time. Based on the time-dependent amplitudes of IMFs, we develop an Event Trigger Generator and demonstrate its efficiency by applying it to gravitational-wave data.

  • PDF

Contrast-Enhanced Magnetic Resonance Imaging at True End-Diastole to Quantify Reproducible Transmural Extent of Myocardial Hyperenhancement

  • 최병욱;최규옥;김영진;정남식;임세중
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.44-44
    • /
    • 2003
  • To determine feasibility of contrast-enhanced MRI (co-MRI) at true end-diastole (ED) free from limitation of time for inversion-recovery and trigger window for quantifying transmural extent of infarction. 대상 및 방법: MRI was performed in 18 patients with myocardial infarction. Cine imaging and co-MRI with same registered slices in short axis were peformed. To allow true ED co-MRI, ECG synchronization should use two RR-intervals for one acquisition of a segment of k-space by setting the heart rate to half that of the true heart rate. Trigger delay time was adjusted to the RR-interval for imaging at ED and to the sum of RR-interval plus the time between R-wave and the end-systole (ES) determined in cine images for imaging at ES.