• Title/Summary/Keyword: treatment efficiency

Search Result 5,229, Processing Time 0.036 seconds

Evaluation on Removal Efficiency of Cryptosporidium using Surrogate in Pilot Plant of Conventional Water Treatment Process (표준정수처리 파일럿에서 Cryptosporidium 유사체를 이용한 Cryptosporidium 제거효율 평가)

  • Park, Sangjung;Chung, Hyenmi;Choi, Heejin;Jun, Yongsung;Kim, Jongmin;Kim, Taeseung;Chung, Dongil
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.399-405
    • /
    • 2010
  • In order to quantify removal efficiency of Cryptosporidium in water treatment process and evaluate factors influencing removal efficiency of Cryptosporidium in each step of water treatment process, large pilot plant system ($100m^3/day$) and Cryptracer, surrogate of Cryptosporidium, were used. The removal efficiency of Cryptracer was around 0.8~1 log in coagulation process and 3.3~4.8 log in sand filtration process under ordinary environmental conditions. Factors influenced removal efficiency of Cryptracer were high fluctuate turbidity and water temperature. High fluctuate turbidity made difficult to adjust optimum PAC concentration, caused to drop removal efficiency of coagulation process (0.5 log). Inadequate coagulation process influenced to sand filtration process (2.1 log), caused to decline of removal efficiency in the whole process (2.6 log). Low temperature below $2^{\circ}C$ also influenced coagulation process (0.6 log). Therefore, It is shown that careful attention in the control of Cryptosporidium is needed in flood period, when high fluctuate turbidity would be, and winter period of low temperature.

Evaluation of the Non-point Source Treatment Facility using the porous lightweight aggregate and the recycled aggregate (다공성 경량골재 및 순환골재를 이용한 비점오염원 저감시설의 처리효율 평가)

  • Kang, Young-Heoun;Jang, Dae-Chang;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.735-741
    • /
    • 2009
  • This study intends to evaluate the efficiency of non-point source reduction technique by using the porous lightweight and recycled aggregate which microorganism is seeded. In case of infiltration velocity 30~70 mm/hr in high concentration of influent, it is indicated that SS was 40~94%, COD 44~91%, BOD 4~91%, TN 1.2~66%, TP 7~70% of removal efficiency. Removal efficiency is good in infiltration velocity 30 > 50 > 70㎜/hr order. Therefore, the non-point source treatment facility filled with lightweight and recycled aggregate using microbial seeding shows higher removal efficiency than a conventional sand and gravel. We confirm that the function and efficiency are improved significantly and applied to treat non-point sources.

Removal Characteristics of Hazard Organic Substances in the Multi-stage Ozone Contactor (다단오존접촉조에서 유해화학물질의 제거특성)

  • 박영규
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.41-49
    • /
    • 1999
  • The water treatment by was performed to remove VOC and organic substances in the multi-stage ozone contactor. Ozone is mainly utilized to change the chemical structures of organic substance, of which finally has the purpose to degrad them. The removal efficiency of VOC has 20~60% at the ozone concentration of 3 ppm, in case of trichloroethylene, its efficiency is reduced by 85% at the ozone contact time of 8 min. Design factors such as the number of stage, ozone concentration, zone contact time are determined for optimal treatment in the multi-stage contactor.

  • PDF

A Study on Improvement of Sewage Treatment System (오염처리장의 처리효율 개선연구)

  • 성일화
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.3
    • /
    • pp.36-40
    • /
    • 1993
  • The objective of this research was to retrofit an on-site sewage treatment system suitable to current situation of Korea to reduce the pollution loading and preserve the invaluable water resources. Operation at the F/M ratio of 0.1 kg. BOD/kg MLSS day showed 87.1% BOD removal efficiency and 84.5% COD removal efficiency, and its effluent concentration was 6.4 mg/l as BOD and 21.7 mg/l as COD. Average removal of total nitrogen showed high removal efficiency of 80%.

  • PDF

A clinical study of the effects of Oriental medical treatment on Vascular Dementia (Vascular Dementia에 관(關)한 한의학적(韓醫學的) 임상연구(臨床硏究))

  • Hyun Kyung-Chul;Kim Jong-Woo;Whang Wei-Wan
    • Journal of Oriental Neuropsychiatry
    • /
    • v.10 no.1
    • /
    • pp.147-157
    • /
    • 1999
  • In order to confirm the efficiency of Oriental medical treatment on Vascular dementia, 24 probable and possible vascular dementia patients diagnosed by ADDTC criteria, were chosen and followed among the patients who had visited KOMC from April, 1996 to March, 1997. They were given herbal and acupuncture therapy, mainly focused on circulating qi(順氣)and removing phlegm(治痰) which is generally applied in early stage of cerebro-vascular disease, and then assessed by the improvement of stage according to the level of impairment, as proposed by APA. The results were as followed. 1. Out of 25 cases, 8 patients showed 2 grade improvement(++), 15 patients showed 1 grade improvement(+), and 1 patient showed no change. 2. The efficiency of treatment is higher when they're given treatment earlier. 3. The efficiency of treatment is higher when their symptoms are lighter. In conclusion, this study shows meaningful effect of Oriental medical treatment on vascular dementia and also shows that It's more effective in the case of short onset and mild symptom.

  • PDF

The Effect of Plasma Treatment on the OLED Characteristics (플라즈마 처리가 유기발광다이오드의 특성에 미치는 영향)

  • Shin, Se-Jin;Ahn, Jong-Myung;Kim, Min-Young;Jang, Ji-Geun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.1 s.18
    • /
    • pp.23-26
    • /
    • 2007
  • The effects of plasma treatment on the ITO/glass substrate before deposition of organic materials were investigated in the fabrication of green light emitting organic devices with $Alq_3-C545T$ fluorescent system. In our experiments, the optimum plasma treatment was obtained at the power and time of 150W and 2 minutes under the $Ar(50%)/O_2$ ambient of 1 mTorr. The green OLED with plasma treatment at 150W for 2 minutes showed the luminance and efficiency of $4700\;cd/m^2$ and 8 lm/W at 10V, respectively. On the contrary, the same structured device without plasma treatment showed much lower performance with the luminance of $2600\;cd/m^2$ and the efficiency of 3.6 lm/W at 10 V.

  • PDF

Hair Damage and Wave Efficiency according to the Degree of Alkalinity in Permanent Wave

  • Jeong, Nam-Young;Lim, Sun-Nye;Choi, Chang-Nam
    • Applied Microscopy
    • /
    • v.42 no.3
    • /
    • pp.136-141
    • /
    • 2012
  • Diversification and individualization are pursued to fulfill the increasing human desire for beauty. There are many methods to change human appearances; of these, a permanent wave is often applied to improve beauty. A permanent wave uses physical and chemical methods to break and reform the bonds of natural hair. Thus, research into the optimized conditions for permanent waves is necessary to minimize hair damage and improve the efficiency of the treatment. The object of this study is to examine the effect of varying the alkalinity (8%, 12%, and 16%) of the permanent wave treatment on the wave efficiency, degree of hair damage via tensile strength, and degree of hair protein release. The results indicate that the treatment with the highest alkalinity (16%) is more effective than that with 8% alkalinity; however, the degree of hair damage when treated with the 16% alkalinity wave is higher than with the 8% alkalinity wave. Additionally, hair proteins increasingly dissolve with increasing alkalinity of the permanent wave.

The Characteristics with HRT Variation on InSub Pilot Plant for Advanced Sewage Treatment

  • Kang, Jin-Young;Huh, Mock
    • Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.174-179
    • /
    • 2009
  • The InSub system(applied for a patent) was developed, as it combined the indirectly aerated submerged biofiltration(InSub) reactor and Anaerobic/ Anoxic reactor. This system which can eliminate organism and nutrient materials at the same time, which is safe and economical to be maintained and managed is more simple process than the complicated existing biological advanced sewage treatment system. The most suitable HRT of this study showed 9 hours. As looking into the effluent concentration and removal efficiency of each item at 9 hours of HRT, each effluent concentration for $SS,\;BOD5,\;COD_{Mn},\;and\;COD_{Cr}$ was 1.46 mg/L, 7,09 mg/L, 9.84 mg/L and 16.42 mg/L. And their removal efficiency was 96.98%. 90.59%, 77.18% and 83.92%, respectively. Each effluent concentration of T-N and T-P was 10.42 mg/L and 1.04 mg/L. Their removal efficiency was 73.38% and 61.62%, respectively. This pilot plant experiment(the state was without the internal recycling.) followed a variety of HRT. The results confirmed that it was to be advanced sewage treatment system with high efficiency when it combined with the internal recycling.

A Study on the Dye Wastewater Treatment Using TiO2 Photocatalyst/Ozonation (광촉매/오존을 이용한 염색폐수처리에 관한 연구)

  • Kim, Chang-Kyun;Chung, Ho-Jin;Kim, Jong-Suk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.6
    • /
    • pp.663-670
    • /
    • 2007
  • This study was performed to provide basic information for evaluating the efficiency and applicable extent of photocatalysis and ozonation for the treatment of dye wastewater. The treatability of dye wastewater by $UV/TiO_2$ and $UV/TiO_2/O_3$ advanced oxidation process (AOP) was investigated under various conditions. The experiments were conducted in a batch reactor of 50 liters equipped with twelve UV Lamps of 16W. In $UV/TiO_2$ AOP, the removal efficiency of TCODMn and Color increased to 58% and 67% respectively with increasing UV intensity. Also, The removal efficiency of TCODMn and Color increased to 97% and 99% respectively with increasing $H_2O_2$. Acid area was more efficient than neutral and alkalic areas in wastewater treatment, and pH 5 was the most effective and the treatment efficiency continually increased as the amount of photocatalyst was increased. When the photocatalyst was increased, TCODMn was removed faster than Color.

A Study on Landfill Leachate Treatment by Reduced Pressure Evaporation. (감압증발법을 이용한 매립장 침출수 처리에 관한 연구)

  • 문추연;은종극;이태호
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.73-79
    • /
    • 1997
  • This research was intended as an investigation of applying Reduced Pressure Evaporation as efficient treatment method for landfill leachate. According to the variance of time, temperature, pressure and pH in experiments, the properties of leachate treatment are follows. The removal efficiencies of COD, NH$_{3}$-N, TOC, Conductivity and SS on the basis of reaction time was 96.4%-97.5%, -1.4%-53.7%, 81.7%-89.0%, 92.0%-95.3% and 99.86%-99.97%, respectively. When the pH of Influent was 7.5, the pH of effluent was increased to 10-11 with time elapse. It is concluded that the orgin of pH increase may be ammonia. When the properties of concentrate were investigated at the concentration ratio 90%(V/V), concentration difficiency represented in the ratio of experimental value/calculated value had following orders ; COD>TOC>NH$_{3}$-N>Conductivity>SS. Concentrate had good precipitation because of additive thermal treatment in the process. When evaporation experiments with pH adjustment of 4.0, 6.0, 7.5, 9.0 and 10.0 were performed ; Acidic evaporation experiments(pH 4.0, 6.0) showed low removal efficiency(81.6, 87.6%) of COD and high removal efficiency (97.5%. 84.6%) of NH$_{3}$-N at initial evaporation. Basic evaporation(pH 9.0, 10.0) showed high removal efficiency (97.2%, 98.9%) of COD and very low removal efficiency (-7.4%, -27.2%) of NH$_{3}$-N at initial evaporation.

  • PDF