• Title/Summary/Keyword: treatment cost

Search Result 2,218, Processing Time 0.029 seconds

A Study about Applicability of Treatment for Backwash Water Using Tubular Membrane System with Dead-End Operation Mode (역세 배출수 처리를 위한 관형막의 전량여과 운전 적용에 대한 연구)

  • Eom, Jung Yeol;Kim, Kwan Yeop;Kim, Young Hoon;Song, June Sup;Kim, Hyung Soo;Han, Myung Ae;Yang, Hyung Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.4
    • /
    • pp.437-444
    • /
    • 2008
  • Many other countries have investigated the new backwash water treatment process to save the existing water resource. There are various methods for reusing backwash water, but the membrane system has received the most interest for its efficiency. The objective of this study was to certify the application of membrane filtration system for the backwash water treatment. The experiment equipment was composed of Lab scale tubular membrane filtration system. Generally, cross-flow operation mode is used in the tubular membrane system but cross-flow operation mode demands high electric cost mainly for the pump energy. So to cut off electric cost, dead-end operation mode was used in this experiment. Filtration and bleed operation cycle was used in this membrane system. Backwash water was concentrated during the filtration process and when backwash water reached our target suspended solid concentration, it was discharged from this system. For efficient operation of filtration and bleed, mathematical matrix was drawn up and with this matrix we could simulate various sets of filtration and bleed time.

The Removal of Organics in an Oxidation Ditch (산화구에서의 유기물 처리에 관한 연구)

  • 김건흥
    • Water for future
    • /
    • v.13 no.3
    • /
    • pp.71-76
    • /
    • 1980
  • The oxidation ditch is an efficient, low cost form of treatment of domestic and many industrial waste. It has gained rapid acceptance because of its simplicity, low cost operation, ease of operation, simple mintenance and flexibiltiy. The objective of this investigation was to measure the removal of organics in an existing dithc that does not have return sludge and which is not preceded by primary sedimentation. To accomplish this objective, samples of the wastewater influent and effluent were collected from the wastewater treatment plant of Mansfield, Texas during practical training. These samples were collected over an extended period of time to obtain samples at various treatment temperatures. Two analytical tests, COD and suspended solids, were used to monitor the operation of the plant. The results show that high removal efficiencies were obtained at high temperatures, with the efficiency decreasing as the temperature decreased to approximatedly 16$^{\circ}C$, at which point the efficienty tmeperature relationship appeared to stabilize.

  • PDF

Recent Progress in Zeolite Membrane for Wastewater Treatment: A Review (폐수처리를 위한 제올라이트 막의 최근 연구에 대한 총설)

  • Lee, Joo Yeop;Patel, Rajkumar
    • Membrane Journal
    • /
    • v.32 no.4
    • /
    • pp.227-234
    • /
    • 2022
  • Wastewater is released from leather, textile, paint, wood, or dye processing industries as well as petroleum refining industries. Wastewater from these industries contains water pollutant such as heavy metals and nitrogen compounds and has high chemical oxygen demand (COD). While there various filtering pollutants from wastewater for safe disposal, membrane-based technology is one of the most efficient methods for its high efficiency and low cost. Among various membranes, zeolite membranes gain spotlight for its cost-effectiveness and have undergone a lot of research. This review is focused on recent progress in zeolite membrane for wastewater treatment in following order: i) wastewater treatment, ii) microfiltration membrane, iii) hollow fiber membrane, and iv) ultrafiltration membrane.

Dehydration and RDF Production of Organic Sludge with Hydrothermal Pre-treatment Process (증기열 전처리공정을 이용한 유기성 슬러지의 건조 및 성형연료화)

  • Park, Se-Joon;Choi, Yong-Sung;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.526-531
    • /
    • 2009
  • This paper suggests the dehydration and RDF(Refuse Derived Fuel) production of organic sludge, livestock manure and sewerage sludge causing environmental problems, with hydrothermal pre-treatment process. The renewable technology from the organic wastes must involve short treatment time required, reusable energy source, anti-odor and viruses, low cost for the treatment, and well-fertilization. The hydrothermal pre-treatment process promotes to evaporate moisture in the sludge after being shortly treated in a reactor, which is supplied steam and heat by an external boiler, due to the pressure with steam breaks the cell walls of the sludge, so this process removes the internal moisture of the cell. Then, the treated sludge(solid-state) is mixed with waste vinyls called RDF(6,706kcal/kg).

Dehydration and RDF Production of Organic Wastes with Pressurized Hydrothermal Treatment Process (증기가압형 처리공정을 이용한 유기성 폐기물의 건조처리 및 고형연료화)

  • Park, Se-Joon;Choi, Young-Chan;Choi, In-Kyu
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.5
    • /
    • pp.439-446
    • /
    • 2009
  • This paper investigates the dehydration and RDF (Refuse Derived Fuel) production of organic wastes, livestock manure and sewerage sludge with pressurized hydrothermal treatment process. The renewable technology for the organic wastes must involve short treatment time required, reusable energy source, anti-odor and viruses, low cost for the treatment, and well-fertilization. The pressurized hydrothermal treatment process promotes to evaporate moisture in the waste after being shortly treated in a reactor, which uses steam and heat supplied by an external boiler. By the pressurized steam, the cell walls of the waste break and effectively release the internal moisture. Then, the dried waste can be mixed with waste vinyls to produce RDF with a higher heating value as high as 6,700 kcal/kg.

Development of Treatment Facilities for Swinery Wastewater Using Steel-making Slag (제강슬래그를 이용한 돈사폐수 처리 시설 개발)

  • 이건주;이종은;김순영;김태희;백승철
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.4
    • /
    • pp.127-133
    • /
    • 2000
  • The incomplete treatment of the swinery wastewater is one of the major factors of the river contamination resulting from an eutrophication. Even through many treatments were considered to reduce the contamination of the river by the swinery wastewater, the most effective treatment was not developed yet. Therefore, this project was focused on the development of the treatment that was a low cost and a high efficiency using a steel-making slag. The swinery wastewater was passed through a U-type tube packing the slag in the laboratory. And the swinery wastewater was cleaned effectively in the laboratory experiment. Based on these laboratory results, the treatment facility in a stock farm was constructed to confirm the effect of slag on the first-treated swinery wastewater. After the treatment of the first-treated swinery wastewater through the slag, the water quality of the river was improved and the biodiversity was increased.

  • PDF

Breast Cancer Inpatients Undergoing Mastectomy from a Hospital in Guangzhou, China: A Retrospective Analysis 2004-2013

  • Lu, Jian-Jun;Li, Heng-Ai;Xiong, Ying
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.11
    • /
    • pp.4577-4581
    • /
    • 2015
  • Background: To explore the hospitalizations of breast cancer patients undergoing mastectomy, and to provide a basis for management, clinical prevention and treatment. Materials and Methods: We conducted an investigation by means of the retrospective survey and the medical records retrieval system, and made out the data of patients suffered from breast cancer in a hospital in Guangzhou from 2004 to 2013, including age, medical payment methods, pathological type, treatment, treatment results, complications, hospitalization days, cost and so on. Results: The average age of the inpatients was 50.14 years old. The main histologic types were infiltrating duct carcinoma (88.06%). The main surgery was modified radical mastectomy (80.41%). The cure rate was 90.80% during the 10 years. The main medical payment method was self-paying (57.28%). The average hospital stay was 13.51 days, and average hospitalization cost was RMB 23,083.66 yuan, proportion of drug fees up to 39.70%. Postoperative complication rate was 0.79%. The self-paying group was with the highest proportion of drug fees (P<0.05), while the free medical service group was with the longest hospitalization days (P<0.05). Conclusions: The payment methods significantly affected the proportion of drug fees and hospitalization days. The therapeutic effect was satisfactory with less complications and reasonable proportion of drug fees in our hospital.

Self-Esteem, Body Image and Factors Influencing on Depression of Infertile Women (난임여성의 자아존중감, 신체상과 우울에 미치는 영향요인)

  • Hwang, Ran Hee
    • Journal of Digital Convergence
    • /
    • v.15 no.10
    • /
    • pp.537-549
    • /
    • 2017
  • This purpose of this study was to investigate self-esteem, body image and depression in infertile women and to identify factors influencing depression. There were statistically significant difference in self-esteem on variables such as age, education, occupation, pressure of treatment cost. There were statistically significant difference in body image on variables such as period of marriage, education, pressure of treatment cost. There were statistically significant difference in depression on variables such as age, education, family structure, pressure of treatment cost. Self-esteem was positively correlated with body image(r=.688, p=.000). Depression was negatively correlated with self-esteem(r=-.710, p=.000) and body image(r=-.526, p=.000). Factors influencing depression were self-esteem(b=-0.66, p=.000), Living with parents-in-law(b=-7.92, p=.001), and age over 40 years(b=-1.72, p=.033), which explained 63.5%.

Review of Domestic Sleep Industry Classification Criteria and Aanalysis of characteristics of related companies

  • Yu, Tae Gyu
    • International journal of advanced smart convergence
    • /
    • v.11 no.1
    • /
    • pp.111-116
    • /
    • 2022
  • After COVID-19, the number of people with sleep disorders around the world is increasing. In particular, in the flow of the 4th industrial revolution, the differentiation of types and characteristics of the sleep industry is accelerating. Therefore, in this study, the characteristics of each type of sleep-related industry were reclassified from an industrial point of view, and based on this, an attempt was made to review the classification system that can help companies develop sleep products and improve related national systems. Based on the 10th standard industry classification, we compared input cost, value, and usability and analyzed common characteristics, treatments, and preventive effects based on this. A comprehensive taxonomy using matrix analysis was reviewed. As a result, in terms of cost (A), the most common sleeping products are general mattresses and general bedding. It is an IOT device (auxiliary device), and the value aspect (B, B/D) included sleep cafe, bedding rental and management service, and sleep consulting. In terms of utility (A/B), a total of 6 product groups including sleep aids (health functional foods) belong to this category, and in terms of treatment (A/C), a total of 3 product groups including sleep clinics (medical services) belong to this category. As for the product group (A/D) with both properties, it was found that non-insurance sleep treatment medical devices, sleep-related over-the-counter drugs, and some sleep monitoring applications belong to this category. Ultimately, it was found that the sleep industry classification enables the most active product development and composition according to the relative relationship between cost and utility, and treatment and utility. appeared to be necessary.

Field Application of Least Cost Design Model on Water Distribution Systems using Ant Colony Optimization Algorithm (개미군집 최적화 알고리즘을 이용한 상수도관망 시스템의 최저비용설계 모델의 현장 적용)

  • Park, Sanghyuk;Choi, Hongsoon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.4
    • /
    • pp.413-428
    • /
    • 2013
  • In this study, Ant Colony Algorithm(ACO) was used for optimal model. ACO which are metaheuristic algorithm for combinatorial optimization problem are inspired by the fact that ants are able to find the shortest route between their nest and food source. For applying the model to water distribution systems, pipes, tanks(reservoirs), pump construction and pump operation cost were considered as object function and pressure at each node and reservoir level were considered as constraints. Modified model from Ostfeld and Tubaltzev(2008) was verified by applying 2-Looped, Hanoi and Ostfeld's networks. And sensitivity analysis about ant number, number of ants in a best group and pheromone decrease rate was accomplished. After the verification, it was applied to real water network from S water treatment plant. As a result of the analysis, in the Two-looped network, the best design cost was found to $419,000 and in the Hanoi network, the best design cost was calculated to $6,164,384, and in the Ostfeld's network, the best design cost was found to $3,525,096. These are almost equal or better result compared with previous researches. Last, the cost of optimal design for real network, was found for 66 billion dollar that is 8.8 % lower than before. In addition, optimal diameter for aged pipes was found in this study and the 5 of 8 aged pipes were changed the diameter. Through this result, pipe construction cost reduction was found to 11 percent lower than before. And to conclusion, The least cost design model on water distribution system was developed and verified successfully in this study and it will be very useful not only optimal pipe change plan but optimization plan for whole water distribution system.