• 제목/요약/키워드: treated sewage

검색결과 244건 처리시간 0.034초

국내 지렁이 이용기술 현황조사 (A Study on Vermicomposting Technology in Korea)

  • 최훈근;김규연;김종모;이창호
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2001년도 춘계 학술대회
    • /
    • pp.19-25
    • /
    • 2001
  • Recently in Korea, treatment and disposal of organic wastes have being the mostimportant is sue due to governmental strong regulation of landfill banning Especially the sewage sludge and food wastes will be restricted from the direct landfilling, after the year 2003 and 2005 respectively. Thus the considerable change in treatment methods of organic wastes is founded to transfer toward recycling the organic wastes, In these trends. vermicomposting is being enlightened newly in Korea. In November of 1999. the first symposium focusing the organic waste treatment using the earthworm was held with attending many peoples including earthworm company, experts. and professors. In that symposium, it was reported that the vermicomposting plants treating organic wastes had increased to about 80 plants and had treated about 110,000 tons per year in Korea Many local governments and companies showed the interest in vermicomposting of organic wastes and needed the collaboration with each other and foreign countries. In for reclamation materials, the extraction of some medical drugs from earthworm was expanding the research and development fields, In this paper, the history of vermicomposting in Korea was reviewed and the present stanls and future aspect were showed.

  • PDF

하수처리수의 농업용수 재이용에 따른 포장단위 수질영향 분석 (Analysis of Wastewater Reuse Effect on Field-Scale Water Quality)

  • 성충현;김성재;김성민;김상민
    • 한국농공학회논문집
    • /
    • 제53권4호
    • /
    • pp.59-65
    • /
    • 2011
  • The purpose of this study was to analyze the water quality change when wastewater applied to study paddy fields. CREAMS-PADDY (Chemical, Runoff and Erosion from Agricultural Management System) model was used to estimate the field-scale water quality. Simulated results were compared with observed data monitored from Byeongjeom study paddy fields which is located near the Suwon sewage treatment plant in Gyeonggi-do. Significance analysis was performed for the three different irrigation water quality level and five fertilizer reduction scenarios using LSD (Least Significant Difference) and DMRT (Duncan's Multiple Range Test). Total nitrogen was found to be significant for both irrigation water quality level and fertilizer reduction while total phosphorus was not. Annual drainage load for total nitrogen was reduced by 66~92 % compared to irrigation load when treated wastewater irrigated to study paddy fields from 2002 to 2007. Total phosphorus was reduced by 70~86 %.

폐기물 성상분석과 매립장 침출수가 환경에 미치는 영향에 관한 연구 (A Study on the Component Analysis of Municipal Solid Wastes and the Effect of Landfill Leachate on the Evironment)

  • 윤오섭
    • 한국환경보건학회지
    • /
    • 제18권1호
    • /
    • pp.58-62
    • /
    • 1992
  • The objective of this study is to investigate the generation rates, composition, propertion and lower heating values of each material in the municipal solid wastes(MSW) as well as the effect of landfill leachate on the environment in Taejon. The results are as follows: 1. The annual average generation rate of MSW in Taejon is approximately 1.7kg/c.d. 2. The weight percent of combustible matters is on average 80 and the lower heating value of MSW is measured to be more than 1,700 kcal/kg after removing the briquette component. 3. It is necessary for us to take a proper management system for leachate treatment in the landfill because it has many problems in the sewage and groundwater. 4. It is recommeded that MSW be treated by multiple methods such as the sanitary landfill, resources and recovery, composting and incineration.

  • PDF

은나노 모래를 이용한 모래여과에서 유기물질 제거 및 소독 효과에 관한 연구 (A Study on the Removal of Organics and Disinfection Effect in Sand Filter Using Nano Silver Sand)

  • 선용호
    • KSBB Journal
    • /
    • 제27권1호
    • /
    • pp.16-20
    • /
    • 2012
  • In this study, novel nano silver sand filtration method was compared with UV treatment and normal sand filtration method through filtering treated water from sewage treatment plant. As a result, $BOD_5$ removal rate of nano silver sand filtration showed higher approximately 31% and 23%, comparing with UV treatment and sand filtration. Moreover, $KMnO_4$ removal rate of nano silver sand was about 6.6 and 2.8 times higher than other two methods. In addition, it showed better for removing SS and total coliform, comparing with others. Also, there is no bacteria on nano silver sand after experiments. Therefore, nano silver sand filtration will be effective for advanced water treatment.

미계측 유역에서 저수량 산정 방법 비교 연구 (Comparative Study on Evaluating Low-Flow in Ungauged Watershed)

  • 백경오
    • 한국안전학회지
    • /
    • 제29권1호
    • /
    • pp.31-36
    • /
    • 2014
  • In this study, the methodologies for evaluating the low-flow at the ungauged watershed are reviewed and assessed. The ungauged watershed can be classified into different situations such as the partially recorded watershed and the completely ungauged watershed. The extension method and the percentile method are used to evaluated the low-flow at the partially recorded watershed. The drainage-area ratio method and the regional regression method are used at the completely ungauged watershed. These four methods are applied and validated based on the hydrological and geometric data acquired from unit watersheds in Han River basin for TMDLs. In case of partially recorded watershed, the values of low-flow evaluated by the extension method are in better agreement with measured flow-rate rather than those by the percentile method. In case of completely ungauged watershed, the drainage-area method is broadly used to estimate the low-flow. It must be paid attention to consider the treated sewage discharge produced at watersheds when applying the method.

Treatment of Domestic Wastewater by the Application of Electrochemical Membrane Bioreactor and Generation of Bioelectricity

  • Yadav, Saurabh;Kamsonlian, Suantak;Pal, Shubham
    • 공업화학
    • /
    • 제33권5호
    • /
    • pp.532-537
    • /
    • 2022
  • The need for obtaining treated wastewater that meets high quality standards for discharge or reuse necessitates the use of highly efficient wastewater treatment techniques. In the present study, experiments have been carried out to reduce the concentration level of biological oxygen demand (BOD), chemical oxygen demand (COD), and total dissolved solids (TDS) from the wastewater sample. Treatment of sample of a real municipal wastewater collected from a sewage treatment plant (STP) was carried out in an electrochemical membrane bioreactor (EMBR). The EMBR was operated continuously for five days, and readings were taken at regular intervals. This paper has experimental results conducted in EMBR that indicate reduction of BOD, COD, and TDS levels of up to 32.25%, 29.25%, and 31.93%, respectively. Further, it was observed that a current of magnitude of 0.00752 mA was generated due to the metabolic activities of bacteria present in municipal wastewater, which gradually decreased day by day due to the decay of bacteria.

해조류 첨가를 통한 하수슬러지 산발효 효율 증대 (Enhanced Acidification Efficiency of Sewage Sludge by Seaweed Addition)

  • 신상룡;이모권;김민균;홍성민;김동훈
    • 유기물자원화
    • /
    • 제25권1호
    • /
    • pp.15-21
    • /
    • 2017
  • 본 연구에서는 하수슬러지의 유기산 생산에 있어 해조류 첨가를 통한 상승효과를 확인하고자 새로운 접근을 시도하였다. 기질농도를 동일하게 20 g COD/L로 하고 하수슬러지와 해조류의 혼합비율을 COD 기준, 100:0, 75:25, 50:50, 25:75, 0:100으로 조절하여 실험하였다. 실험 온도는 $35^{\circ}C$, 중온에서 이루어졌고 메탄 생산균의 활성을 억제하기 위해서 $90^{\circ}C$, 20분간 열처리된 혐기성소화슬러지를 식종균으로 이용하였다. 실험결과를 살펴보면, 해조류의 첨가량이 증가할수록 유기산의 농도도 증가하는 경향을 나타내었으며 혼합비율별 100:0, 75:25, 50:50, 25:75, 0:100 (하수슬러지:해조류) 유기산 생산량은 각각 1.45, 3.22, 4.28, 5.24, 4.82 g COD/L이었다. 하수슬러지와 해조류만의 유기산 생산량을 기반으로 하여 상승효과를 계산한 결과, 혼합비율 75:25, 50:50, 25:75 에서 각각 0.92, 1.14, 1.26 g COD/L로 나타났다. 이는 해조류가 25% 비율로 첨가 시 전체 생산된 유기산의 40%가 상승효과에 의해 생산되었음을 의미하며, 해조류의 상대적인 높은 C/N비와 생분해도에 기인한다.

혼합 소화공정에서 내부반송과 다양한 전처리를 통한 하수 슬러지 처리 (Sewage Sludge Treatment with Internal Recirculation and Diverse Pre-treatment Methods Using Combined Digestion Process)

  • 하정협;최석순;박종문
    • 공업화학
    • /
    • 제29권5호
    • /
    • pp.613-619
    • /
    • 2018
  • 본 연구에서는 유입 슬러지에 다양한 전처리 방법과 고액분리장치를 이용한 유출수의 잉여슬러지를 농축 후 내부반송을 적용하여, 중온혐기-고온호기 혼합 슬러지 처리 공정의 슬러지 소화효율과 메탄가스 생성량에 미치는 영향을 비교 검증하였다. 실험실 규모의 혼합 소화공정장치를 제작하여 서로 다른 유입 슬러지 전처리방법을 적용하여 5단계로 실험을 진행하였다. 1단계에서는 열-알칼리처리 전처리를 하여 슬러지를 공급하였고, 2, 3, 4단계에서는 유출수로부터 농축된 잉여슬러지의 내부반송과 각각 열-알칼리처리, 열처리, 알칼리 처리(7일)를 거친 유입 슬러지를 공급하였다. 마지막 5단계에서는 전처리를 하지 않은 슬러지를 공급하였다. 실험 결과, 1단계에서 4단계까지 진행되는 동안 Volatile Suspended Solid (VSS) 제거율은 유입 슬러지 전처리와 내부반송을 적용하는 경우 크게 증가하였으며, 메탄생성량 또한 2단계에서 슬러지 내부반송과 열-알칼리처리 전처리 적용의 경우 285 mL/L/day까지 크게 증가하였다. 한편, 5단계에서 전처리를 하지 않은 슬러지를 공급하였을 경우 VSS 제거율과 메탄 생성량이 크게 감소하였다. 결론적으로, 유입 슬러지의 열-알칼리처리 전처리와 유출수의 농축 잉여슬러지의 내부반송을 통해 복합 슬러지 처리 공정의 슬러지 제거 효율과 메탄생성량을 크게 증가시킬 수 있었다.

경안천${\sim}$팔당호의 부영양화와 수질오염 특성 (Eutrophication and Water Pollution Characteristics of the Kyongan Stream to Paltang Reservoir)

  • 조주래;황순진;조경제;신재기
    • 생태와환경
    • /
    • 제33권4호통권92호
    • /
    • pp.387-394
    • /
    • 2000
  • 경안천의 상${\cdot}$하류와 팔당호 주요 유입부에서 부영양화 양상과 수질오염 특성을 파악하기 위해 2000년 4월부터 7월까지 조사하였다. 경안천 수질은 전형적인 과영양상태를 보였고 상류에 위치한 오${\cdot}$폐수처리장(sewage wastewater treatment plant, SWTP)의 배출수가 본류와 합류된 직후부터 크게 악화되었으며, 이에 대한 영향은 하류의 부영양화에 절대적이었다. 배출수로부터 비롯되는 NH$_{4}$와 SRP 영양염은 하류로 유하하면서 급감하는 반면에 자생유기물의 chl-a는 중류에서 폭발적인 증가를 보였다. 환경요인 중 본류에서 NH$_{4}$, SRP 및 chl-a의 평균농도는 각각 1,343 ${\mu}$g N/l, 1,779 ${\mu}$g P/l 및 188 ${\mu}$g/l였고, 특히 P에 대한 부하가 매우 컸으며 식물플랑크톤 생장에 미치는 영향이 현저하였다. 팔당호 유입부 수질의 비교에서 경안천은 북한강과 남한강의 다른 하천에 비해 오염 수준이 가장 높은 것으로 볼 수 있었다. 결과적으로 볼 때, 경안천 뿐만 아니라 팔당호의 상수원 수질보호를 위해서는 오${\cdot}$폐수 처리수의 점오염원 관리에 대한 대책 마련이 매우 시급한 것으로 판단되었다.

  • PDF

유입수 분배비와 체류시간이 ASA 공정의 가정오수 처리효율에 미치는 영향 (Effects of Influent Flow Distribution Ratio and HRT on Sewage Treatment Efficiency of the ASA Process)

  • 양은경;성일화
    • 환경위생공학
    • /
    • 제24권1호
    • /
    • pp.13-24
    • /
    • 2009
  • ASA공정은 유입수를 혐기조와 무산소조에 분배하여 유입시킴으로써 반송슬러지에 영양 물질을 공급하여 슬러지의 안정화 및 인 방출을 유도하고, 후속 호기조에서 유기물 제거, 인 과잉섭취 및 질산화를 조장하며, 무산소조에서는 내부반송을 하지 않고 폐수의 탄소원을 이용하여 탈질함으로써 내생탈질을 증가시키는 공법이다. 본 연구에서는 가정오수에 ASA공정을 적용하여 유입수의 분배비와 체류시간이 처리효율에 미치는 영향을 파악하였다. 유입수 분배비와 HRT는 BOD 제거에 큰 영향을 미치지 않았고 BOD 제거율은 운전기간 동안 92.0% 이상 안정적으로 유지되었다. 유입수 분배비가 4:6일 때에는 질소제거율이 82.6%, 9:1일 때에는 인제거율이 67.8%로서 가장 높게 나타났다. ASA공정에 의한 가정오수처리에서 유입수의 분배비는 6:4, HRT는 8hr일 때 제거율이 가장 양호하였으며, 이때 질소, 인제거율은 각각 82.6%와 59.5%이었다.