• Title/Summary/Keyword: tray

Search Result 579, Processing Time 0.029 seconds

RETENTIVE FORCE OF ADJUSTABLE DENTAL IMPRESSION TRAYS WITH DIFFERENT RETENTION FORMS (유지형태에 따른 가변형 치과 인상용 트레이의 유지력에 관한 연구)

  • Song Kie-Bum;Kim Sung-Rok;Park Kwang-Soo;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.15-29
    • /
    • 2005
  • Statement of problem. The adjustable dental impression trays were made for being adjusted their width automatically along the width of dental arch. Purpose. The purpose of this study was to investigate the best retentive form of adjustable dental impression tray, and so to make it a more satisfactory product. Material and methods. The eight pairs of adjustable trays were made of ABS(acrylonitrile butadiene styrene) with different distribution of holes and with or without the rim on the border area of them. The experiment was done with the horse-shoe shaped metal plate to pull out the set impression body from the tray, and the tray jig which was made for holding the tray on a lower part of Universal Testing Machine(UTM, Zwick Z020, Zwick Co., Germany). After the impression in the tray was allowed to set four minutes, a tensile force was applied at right angles to the tray which had been previously seated on the jig. The force was applied to measure a maximum retentive force by use of a UTM at a constant strain rate of 100mm per minute. A 2-factor analysis of variance (p<.05) was used to determine whether differences existed among distribution of retentive holes and between rim existing and not. Results. 1 The retentive force of the upper and lower resin tray with 2mm holes on the tray border was highest(25.83/24.98kg). (p<.05) 2. As the tray had more retentive holes, it was less retentive. 3. There was no significant difference in the retentive force of the varied hole intervals in the case of distributing all the area. (p>.05) 4. The rimless trays were more retentive generally, than the rimmed trays except 2 case: upper tray group-all area / 2 mm, intervals and lower tray group-margin only / 2 mm, intervals.(p<.05) 5. Most of the adjustable trays were showed higher retentive force than perforated metal tray except the lower group that perforated on the all area at intervals of 2 mm.

Optimum Packaging Design of Packaging Tray and Cushion Pad of Korean Pears for Exporting using FEA Simulation (FEA 시뮬레이션 기법을 이용한 수출용 한국 배 포장 트레이 및 완충패드 최적 포장설계)

  • Choi, Dong-Soo;Son, Jae-Yong;Kim, Jin-Se;Kim, Yong-Hoon;Park, Chun-Wan;Jung, Hyun-Mo;Hwang, Sung-Wook
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.5
    • /
    • pp.843-852
    • /
    • 2020
  • Among the many packaging materials used in cushion packaging, there is a lack of optimum design for packaging trays and cushion pads used in pear packaging for export and domestic distribution. It causes over-packaging due to excessive material input, and can be solved by applying various parameters needed to optimize the design of the packaging tray and cushion pad considering the packaging material and the number of pears in the box. In the case of a cushion pad for pears, the economic efficiency of material and thickness should be considered. Therefore, it is possible to design a packaging tray and cushion pad depending on eco-friendly packaging materials (PLA, PET) used by applying appropriate design parameters. The static characteristics of the materials used for the packaging of pears were analyzed using FEA (finite element analysis) simulation technique to derive the optimal design parameters. In this study, we analyzed the contact stress and deformation of PET, PLA tray (0.1, 0.5 1.0, 1.5 and 2 mm) and PET foam (2.0, 3 .0 and 4.0 mm) with pears to derive appropriate cushion packaging design factors. The contact stress between the pear and PET foam pad placed on PLA, PET trays were simulated by FEA considering the bioyield strength (192.54±28 kPa) of the pears and safety factor (5) of packaging design, which is the criterion of damage to the pears. For the combination of PET tray and PET foam buffer pad, the thickness of the PET foam is at least 3 mm, the thickness of the PET foam is at least 1.0 mm, the thickness of the foam is at least 2 mm, and if the thickness of the PET tray is at least 1.5 mm, the thickness of the foam is at least 1 mm, suitable for the packaging design. In addition, for the combination of PLA tray and PET foam pad, the thickness of the PET foam was not less than 2 mm if the thickness of the PLA tray was 0.5 mm, and 1 mm or more if the thickness of the PLA tray was not less than 1.0 mm, the thickness of the PET foam was suitable for the packaging design.

The Accuracy of Master Cast for Implant Prosthesis According to the Types of Impression Tray and Splinting Methods of Impression Copings (인상용 트레이의 종류와 인상용 코핑의 연결고정이 임플랜트 주모형의 정확성에 미치는 영향)

  • Lee, Jee-Hyuk;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.433-445
    • /
    • 2010
  • The aim of this study was to evaluate the fixation effect by connecting impression copings and to compare the three types of impression trays which were used in open tray impression technique. Experimental groups used 3 types of impression trays which are custom tray, plastic metal combination tray and polycarbonate stock tray. These three groups were subdivided into splinted and non-splinted impression copings group. The total number of experimental groups was six. 10 specimens were made for each group. We used 1-screw test, observing the specimen on which only one side abutment of reference framework was fixated with 20 Ncm. The gap between implant analogue and abutment of the other side was observed by stereo microscope. It was measured at 6 points in each specimen. Measuring value was selected when same result was revealed 3 times. Recorded data were statistically analyzed. Whether impression copings were splinted or not, there was no significant difference among custom tray group, plastic metal combination tray group, and polycarbonate stock tray group. Significant statistical difference in vertical fit discrepancy was found between splinted and non-splinted impression copings group with custom tray, plastic metal combination tray and polycarbonate stock tray (p<0.05).

A STUDY ON ACCURACY AND DIMENSIONAL STABILITY ACCORDING TO IMPRESS10N METHODS (인상채득방법과 방향에 따른 인상체의 정밀성과 체적 안정성에 관한 연구)

  • Lee, Jae-Young;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.567-580
    • /
    • 1999
  • Accurate reproduction of intraoral tissue is essential in the fabrication of fixed prosthesis. This selection of impression material and method is very important. In this study, vinyl polysiloxane type impression material $Panasil^{(R)}$ was used. Three impression methods ; one-step technique, individual tray technique, and individual tooth tray technique using the vinyl polysiloxane type bite registration material $Futar^{(R)}$ Occlusion, were used to take horizontal and vertical impression. Improved stone models were fabricated. The amount of occlusal surface discrepaneies, interabutment distance discrepancies, amount of marginal defect were evaluated with the $X-PLAN360d^{(R)}$ and photoscanning. The results were as follows. 1. There was no significant difference in occlusal surface according to the directions and techniques of impression taking. 2. There was no significant difference in interabutment distance discrepancies according to the directions and techniques of impression taking 3. There was no significant difference in marginal discrepancies according to the direction of impression taking but there was significant difference between one-step technique and individual tray technique, individual tooth tray technique (P<0.05). Taken together, these results suggest that individual tray technique and individual tooth tray technique are more accurate for impression taking than one-step technique.

  • PDF

Development of the Mechenical System and Vision Algorithm for the External Appearance Test Using Vision Image Processing (비전 이미지 프로세싱을 이용한 외관검사가 가능한 기계시스템 및 비전 알고리즘 개발)

  • Kim, Young-Choon;Kim, Young-Man;Kim, Sung-Gil;Kim, Hong-Bae;Cho, Moon-Taek
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.202-208
    • /
    • 2016
  • In this study, the defect in connection with a C-tray was inspected using a low-cost camera. The four test items were the device overlapping in the tray, the bending of the tray, the loaded quantity of the tray, and the device pocket leaving, an algorithm was developed for defining and detecting the above defect types. Therefore, the developed handling system could extend the application of the stack of the c-tray and provide a quantity verification inspection on the packing processing. The machine operation control program, which can ensure the optimal inspection image to match the scan speed, was developed and the control program that can process the user gui and the vision image utilizing the control was developed. Overall, a mechanical system that is practicable for obtaining an image and processing the vision data was designed.

Growth effects of novel heating system using heater-installed rearing tray on silkworm, Bombyx mori

  • Jeong, Chan Young;Kim, Kee Young;Kim, Nam-Suk;Kang, Sang Kuk;Park, Jong Woo;Cha, Ik Seob;Kim, Seong-Wan
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.45 no.1
    • /
    • pp.22-28
    • /
    • 2022
  • Silkworms are very sensitive to changes in temperature and humidity, and unless it is a suitable temperature and humidity to grow, the productivity and quality of silkworms are greatly reduced. Therefore, it is very important to manage temperature and humidity for silkworm feeding facilities. In particular, it is essential to install heating facilities in Asian countries with distinct seasonal changes. During the feeding period, many farms manage the temperature and humidity of feeding facilities by installing and using electric heaters inside the facilities. However, it is very difficult to manage the room temperature stably by the heaters. In addition, unlike the temperature inside the facility, silkworms could undergo severe temperature changes as the inside of the rearing tray could not be warm enough. In this study, in order to improve the previous heating method, the new rearing method that directly heats the bottom of the rearing tray was developed. Compared to the previous room-heating system, the novel heater-installed tray (HIT) system significantly reduced the change in temperature during the experimental period. In addition, the number of days of silkworm growth up to harvest was shortened, which was effective in growth performance, and it was also found that silkworms grew more uniformly in HIT system than in previous system. Moreover, as the heater tubes were installed directly under the rearing tray, it quickly dried mulberry leaves and silkworm feces after feeding, and as a result, the environment in the tray was greatly improved with decrease the labor of breeder. In conclusion, these results suggest that the heater-installed rearing tray method greatly improves silkworm quality, increases weight of silkworms, and final profits compared to the previous room heating system with electric heaters.

Evaluation of pepper seedling growth according to the growing period and tray for automatic transplanting

  • Md Nafiul, Islam;Md Zafar, Iqbal;Mohammod, Ali;Ye-Seul, Lee;Jea-Keun, Woo;Il-Su, Choi;SunOk, Chung
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.4
    • /
    • pp.945-956
    • /
    • 2021
  • The effective growth of pepper seedlings relies on the growing period and tray used, which both aim to minimize seedling damage during the transplantation process. Therefore, the objective of this study was to evaluate the effect of red and green pepper seedling growth in plug and cylindrical paper pot (CPP) trays with different growth periods of the seedlings. Two different seedling growth trays were used for the two varieties of pepper seedlings in the same growing media. The pepper seedling growth rates were investigated at 15, 30, and 45 days for each of variety. Important parameters, e.g., the plant height, fresh weight for the plant and root, number of leaves, leaf length and width, and leaf chlorophyll contents, were measured. During the experiment, the CPP tray maintained uniform seedling growth as compared to the plug tray. CPP trays ensured the height of the seedling, with these results 0.84 to 1.6 times higher than those of the plug tray for all conditions, indicating the good quality of the pepper seedlings. The shoot and root weights were found to be greater with more leaves in the CPP tray seedlings for 45 days compared to the seedlings grown in the plug tray, whereas the green pepper variety showed a greater leaf ratio than the red pepper seedlings. The analysis of pepper seedling growth presented in this study will guide the selection of suitable growth trays and seedling periods for farmers when they undertake automatic pepper transplantation in the field.

Development of Dental Scanning System and Reproduction of Adjustable Upper Dental Impression Tray (치과용 스캐닝 시스템의 개발과 가변형 상악용 트레이의 재현성)

  • Cha, Young-Youp;Eom, Sang-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.3
    • /
    • pp.300-304
    • /
    • 2010
  • This study was performed to development a dental three-dimensional laser scanning system and measure the accuracy of new adjustable upper dental impression tray. The metal stock, individual, and new adjustable stock trays were used for 30 stone casts(10 casts each) duplicated a resin master model of maxilla. The dental stone was poured in a vinyl polysiloxane impressions and allowed to set for on hour. The master model and the duplicated casts were digitized using an dental scanning system. The distance between the reference points were measured and analyzed on the graphic image of 3D graphic software of CATIA. The statistical significance of the differences between the groups was determined by a two-way ANOVA. There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch. The adjustable upper stock tray showed clinically acceptable accuracies of the study cast produced by them.

Effect of Resin Material on Molding Characteristics of Disposable Tray for Korean Food (재질이 도시락 용기의 성형 특성에 미치는 영향)

  • Park, Hyung-Woo;Koh, Ha-Young;Kang, Tong-Sam;Shin, Dong-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.252-255
    • /
    • 1988
  • The molding characteristics, hardness and overall quality of the Korean style disposible food tray made from the low and medium density polystyene sheets were investigated and the results were obtained as follows. The volume difference of 8 sectional trays was 56.4% between the two materials, and that of 5 sectional trays was 41.8%. The more the sectional number of the tray, the larger the volume difference. Medium density polystylene tray had the better solid characteristics and overall acceptance than the low density polystlene tray.

  • PDF

The Development of Pulp Mold Tray for Melon Packaging (멜론 포장용 펄프몰드 난좌 개발)

  • Choi, Seung Ryul;Jung, Hoon;Choi, Dong Soo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.19 no.3
    • /
    • pp.125-131
    • /
    • 2013
  • In order to protect agricultural products against damage by physical load, various shock absorbing materials is used. As the demands of environment protection increase, the use of plastic materials have been restricted. On the other hand, Pulp mold products have some benefits - easy manufacturing, superior shock absorbing and eco-friendly. In order to develop pulp mold tray for melon packaging as shock absorbing packaging material, we investigated physical properties and vibration transmission characters of 180, 200 and 220 g pulp mold tray for melon. As the weight of pulp increased, compression strength and shock absorbing performance increased, while vibration transmissibility decreased. Especially in case of 180g pulp mold tray, it is not suitable for melon packaging because the transmitted vibration acceleration was higher than the forced vibration acceleration. And 200g pulp mold tray is suitable for melon packaging because the vibration transmissibility was lowest in three trays. And the vibration acceleration transmitted to the melon in edge of pulp mold tray was higher than to the melon in center of pulp mold tray. As the result of the simulated transportation test, the firmness of melon packaging using pulp mold tray was higher than that of conventional packaging. Therefore, these results suggest that pulp mold tray packaging could be suitable for melon packaging.

  • PDF