• Title/Summary/Keyword: tray

Search Result 579, Processing Time 0.034 seconds

Growth and Yield of Sedum sarmentosum as Affected by Planting Density in Cultivation System Using a Rice Nursery Tray (벼 육묘상자를 이용한 돌나물 재배에서 삽식밀도에 따른 생육 및 수량)

  • Kim, Hyo-Jin;Lee, Seung-Yeob
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.2
    • /
    • pp.196-202
    • /
    • 2008
  • To establish a cultivation system of Sedum sarmentosum using a rice nursery tray ($30{\times}60{\times}3\;cm$) in non-heating plastic film house, cuttings of two local strains (Wanju and Keumsan) were prepared and planted at different planting densities (40, 60 and 80 cuttings per tray) on September 7th, and subsequent growth and yield at pre- and post-winter season were investigated. When pre-wintering growth were measured at 60 days after planting, high planting density (80 cuttings/tray) decreased leaf length and lateral shoot number per plant compared to 40 cuttings/tray. When post-wintering growth were measured on April 20th, no significant growth differences as affected by planting density were observed in Keumsan strain, while decreased stem diameter, node number and leaf number were observed in Wanju strain planted at 80 cuttings/tray compared to 40 cuttings/tray. Fresh and dry weights were not significantly different as affected by planting density, but those were significantly increased in Wanju strain compared to Keumsan strain. When regrowth characteristics followed by the first harvest were measured on June 5th, significantly increased stem number was observed at 80 cuttings/tray compared to 40 cuttings/ tray. Fresh and dry weight were significantly increased in Keumsan strain planted at 80 cuttings/tray compared to 40 cuttings/tray, and dry weight were increased in Wanju strain compared to Keumsan strain. Wanju strain showed higher shoot yield, thicker stem, shorter node and larger leaf, and non-succulent stem under high planting density compared to Keumsan strain. Accordingly, the optimum density was 40 cuttings per tray, and Wanju strain was adequate for the cultivation system using a rice nursery tray.

Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique

  • Pastoret, Marie-Helene;Krastl, Gabriel;Buhler, Julia;Weiger, Roland;Zitzmann, Nicola Ursula
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.287-293
    • /
    • 2017
  • PURPOSE. To compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression. MATERIALS AND METHODS. A machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials: i) putty-wash technique with a prefabricated metal tray (MET) using putty and regular body, ii) single-phase impression with custom tray (CUS) using regular body material, and iii) two-stage technique with stock metal tray (SEP) using putty with a separating foil and regular body material. All impressions were poured with epoxy resin. Six different distances (four intra-abutment and two inter-abutment distances) were gauged on the metal master model and on the casts with a microscope in combination with calibrated measuring software. The differences of the evaluated distances between the reference and the three test groups were calculated and expressed as mean (${\pm}SD$). Additionally, the 95% confidence intervals were calculated and significant differences between the experimental groups were assumed when confidence intervals did not overlap. RESULTS. Dimensional changes compared to reference values varied between -74.01 and $32.57{\mu}m$ (MET), -78.86 and 30.84 (CUS), and between -92.20 and 30.98 (SEP). For the intra-abutment distances, no significant differences among the experimental groups were detected. CUS showed a significantly higher dimensional accuracy for the inter-abutment distances with -0.02 and -0.08 percentage deviation compared to MET and SEP. CONCLUSION. The separation foil technique is a simple alternative to the custom tray technique for single tooth restorations, while limitations may exist for extended restorations with multiple abutment teeth.

Stress Analysis of Total Knee System Depending on Implant Materials and Fixation Methods (인공무릎관절에 있어서 임플란트의 재료 및 고정방법에 따른 응력분석)

  • Cho, C.H.;Cho, Y.K.;Choi, J.B.;Choi, K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.484-488
    • /
    • 1997
  • Three-dimensional finite element analyses were used to compare the stress distribution and the stability of the fixation among seven different tibial components and to investigate the effect due to implant materials in total knee arthroplasty. The components included an intact tibia(Type I), Cemented Cobalt-Chromium tibial tray implanted with a PMMA cemented Co-Cr stem(Type II), Cemented Co-Cr tibial tray with a uncemented Co-Cr stem(Type III), Cemented Ultra High Molecular Weight Polyethylene (UHMWPE) tibial tray with a cemented UHMWPE stem (Type IV), Cemented UHMWPE tray with a uncemented UHMWPE stem(Type V), Cemented Co-Cr tray without a stem(Type VI), and Cemented UHMWPE tray without a stem(Type VII). Uncemented components were assumed to have complete bony in growth and a rigid state of fixation between component and bone. The interface between bone/cement/component of cemented components was also assumed to be fully bonded. Bi-condylar forces were applied. The results indicated that Uncemented stem components provided lower bone stress shielding and stress concentration. The UHMWPE tray and stem component showed better agreement with the intact tibia than the Co-Cr Alloy tray and stem components. If the implant tray can be fixed firmed without a stem, Cemented PE tray without a stem(Type VII) may be recommended to give the best characteristics in the sense of stress distribution and stability.

  • PDF

Control Strategy and Algorithm for Levitation of Over-actuated Passive Maglev Tray System (과구동 자기부상 무전원 트레이의 부상제어 전략 및 자세제어 알고리즘)

  • Ahn, Changsun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.6
    • /
    • pp.553-562
    • /
    • 2015
  • This paper presents a strategy and an algorithm for levitation control of an over-actuated passive maglev tray system. The passive maglev tray system has more actuators than its degrees of freedom. The actuators of the system are switching when the tray travels longitudinally. Furthermore, the levitation forces of the actuators are non-homogeneous because the actuation devices are not in the moving platform. These characteristics make a limit in using conventional control approaches for levitation. For smooth actuator switching, the actuator force generation should be dependent on longitudinal positions of the tray. To enable constant pose tracking, this research introduces a control strategy and a control algorithm based on integral controllers on virtual variables. The states of the tray are estimated using a Kalman filter and fed to the proposed controller. The performances of the proposed control strategy and the algorithm are validated through tests.

A Study on the Tray Panel Analysis Using Static Implicit Finite Element Method (정적-내연적 유한요소법을 이용한 Tray 판넬 해석에 관한 연구)

  • Jung, Dong-Won;Ahn, Hyun-Gil
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.4 no.1
    • /
    • pp.30-36
    • /
    • 2005
  • The static implicit finite element method is applied effectively to analyze total tray panel stamping processes, which include the forming stage. Complicated and abnormal large size tray panel was analyzed by using commercial program called AutoForm. Analysis results examining possibility and validity of the AutoForm software and the factor study are presented. Further, the simulated results for the total tray panel stamping processes are shown and discussed. Its application is being increased especially in the automotive industrial area for the cost reduction, weight saving, and improvement of strength.

  • PDF

A Study on the Development of Plastic Mold Tray Inserting Machine (플라스틱 몰드 트레이 자동 투입장치 개발에 관한 연구)

  • Lee C.M.;Shin S.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.759-762
    • /
    • 2005
  • A tray inserting machine is developed for automation of inserting plastic mold tray into a cardboard box. Plastic mold tray is used for protecting breakdown of glass bottles. In this paper, two types of processes to divide the plastic mold tray are proposed. As a result, adhesion method by vacuum pad is accepted. And also, static and modal analysis for the machine are carried out to check the machine design using the commercial software, CATIA V5.

  • PDF

Validity of Clinically Used Tray Transmission Factor (임상적으로 쓰이는 차폐선반투과율의 타당성에 관한 연구)

  • 윤형근
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.218-224
    • /
    • 2003
  • Purpose:By evaluating the dependence of the tray transmission factor (tray factor) on collimator setting and tray thickness, we determined the validity of the clinically used single tray factor for standard radiation field size (10${\times}$10 $\textrm{cm}^2$). Methods and Materials:For each X ray energies (6 and 10 MV), outputs were measured by using 5 steps of tray thickness (0, 6, 8, 10, 12 mm) and 7 steps of radiation field size (5${\times}$5, 10${\times}$10, 15${\times}$15, 20${\times}$20, 25${\times}$25, 30${\times}$30, 35${\times}$35 $\textrm{cm}^2$) at 10 cm phantom depth. Outputs were measured in both 'with tray' and 'without tray' conditions by using radiation with the same monitor units, and the tray factors were determined by the ratios of the two outputs. To evaluate the validity of a single tray factor obtained for standard radiation field, we analyzed the pattern of the field sizes in cases treated at our hospital in 2002. Results : In the 6 MV X-ray, the increases in the tray factor between the standard field (l0${\times}$10 $\textrm{cm}^2$) and the largest field (35${\times}$35 $\textrm{cm}^2$) were 0.517%, 0.835%, 1.058%, 1.066% in 6, 8, 10, and 12 mm thickness tray, respectively. In the 10 MV X-ray, the increases in the fray factor between the standard field (10${\times}$10 $\textrm{cm}^2$) and the largest field (35${\times}$35 $\textrm{cm}^2$) were 0.517%, 0.836%, 1.058%, 1.066% in 6, 8, 10, 12 mm thickness tray, respectively. In a major portion of clinical cases, when the field size was smaller than 20${\times}$20 $\textrm{cm}^2$, the tray factor was in good agreement with the standard tray factor. However, in cases where the field sizes were 30${\times}$30 $\textrm{cm}^2$ and 35${\times}$35 $\textrm{cm}^2$, the error could exceed 1.0%. Conclusion:The tray factor increased with increasing field size or decreasing tray thickness. The difference of tray factor between the small field and the large field increased with increasing tray thickness. Furthermore, the standard tray factor was valid in most clinical cases except for when the field size was greater than 30${\times}$30 $\textrm{cm}^2$, wherein the error could exceed 1.0%.

  • PDF

A Study on the Effect of Energy Saving with Newly Implemented Vertical Circulating Tray Mixer in Anaerobic digester (혐기성 소화조의 에너지 효율 향상을 위한 수직 왕복형 교반기 적용에 관한 연구)

  • Joo, Yoon-Sik;Son, Guntae;Bae, Youngjun;Park, Jungsoo;Lee, Seunghwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.13-19
    • /
    • 2017
  • Relatively low efficiency in anaerobic digestion process is mainly caused by unproper mixing method. In this study, tray motion type agitator was applied in actual anaerobic digestion tank in order to improve the digestion efficiency, equalize the flow velocity distribution and energy saving. The impeller of tray motion type agitator was reciprocated vertically. Gas lift type agitator and tray motion type agitator appears almost same mixing efficiency include digestion rates. However, tray motion type agitator have shown that lower energy consumption compared to the conventional gas lift type agitator. Implementation of tray motion type agitator in the anaerobic digestion tanks contributed to the stabilization of mixing environment, efficiency and energy efficiency of the tank.

THE EFFECT OF INDIVIDUAL TRAY DESIGN AND IMPRESSION METHOD ON THE BORDER EXTENSION AND CONTOUR OF DENTURE (개인 트레이의 설계와 인상채득방법이 의치 변연의 형태에 미치는 영향에 관한 연구)

  • Lee, Jeong-Woo;Oh, Sang-Chun;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.1
    • /
    • pp.13-23
    • /
    • 1995
  • The purpose of this study is to inquire about the effects of individual tray design and impression method on the border extension and contour of denture. 10 students at the dentistry college who have normal occlusion and symmetric facial form and normal facial muscle activity were selected. The tray was designed three types (large, medium, small tray). After border molding was done by dentist and operator, final impression was taken. The length of impression body and width of border were measured by a vernier caliper on the cast. The obtained results were as follows : 1. As the tray border was shortened, the length of impression body and width of border was short (P<0.01). 2. When the impression was taken with the small tray, the length of impression body was short in passive border molding than active border molding. 3. When the medium tray was used, the width of impression body was short in passive border molding than active border molding.

  • PDF

Performance-based earthquake engineering methodology for seismic analysis of nuclear cable tray system

  • Huang, Baofeng
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2396-2406
    • /
    • 2021
  • The Pacific Earthquake Engineering Research (PEER) Center has been developing a performance-based earthquake engineering (PBEE) methodology, which is based on explicit determination of performance, e.g., monetary losses, in a probabilistic manner where uncertainties in earthquake ground motion, structural response, damage estimation, and losses are explicitly considered. To carry out the PEER PBEE procedure for a component of the nuclear power plant (NPP) such as the cable tray system, hazard curve and spectra were defined for two hazard levels of the ground motions, namely, operation basis earthquake, and safe shutdown earthquake. Accordingly, two sets of spectral compatible ground motions were selected for dynamic analysis of the cable tray system. In general, the PBEE analysis of the cable tray in NPP was introduced where the resulting floor motions from the time history analysis (THA) of the NPP structure should be used as the input motion to the cable tray. However, for simplicity, a finite element model of the cable tray was developed for THA under the effect of the selected ground motions. Based on the structural analysis results, fragility curves were generated in terms of specific engineering demand parameters. Loss analysis was performed considering monetary losses corresponding to the predefined damage states. Then, overall losses were evaluated for different damage groups using the PEER PBEE methodology.