• Title/Summary/Keyword: tray

Search Result 579, Processing Time 0.032 seconds

Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorations

  • Ozay Onoral;Sevcan Kurtulmus-Yilmaz;Dilem Toksoy;Oguz Ozan
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.6
    • /
    • pp.290-301
    • /
    • 2023
  • PURPOSE. The study aimed to determine the influence of implant angulation on the trueness of multi-unit implant impressions taken through different techniques and strategies. MATERIALS AND METHODS. As reference models, three partially edentulous mandibular models (Model 1: No angulation; Model 2: No angulation for #33, 15-degree distal angulation for #35 and #37; Model 3: No angulation for #33, 25-degree distal angulation for #35 and #37) were created by modifying the angulations of implant analogues. Using a lab scanner, these reference models were scanned. The obtained data were preserved and utilized as virtual references. Three intraoral scanning (IOS) strategies: IOS-Omnicam, ISO-Quadrant, and IOS-Consecutive, as well as two traaditional techniques: splinted open tray (OT) and closed tray (CT), were used to create impressions from each reference model. The best-fit alignment approach was used to sequentially superimpose the reference and test scan data. Computations and statistical analysis of angular (AD), linear (LD), and 3D deviations (RMS) were performed. RESULTS. Model type, impression technique, as well as interaction factor, all demonstrated a significant influence on AD and LD values for all implant locations (P < .05). The Model 1 and SOT techniques displayed the lowest mean AD and LD values across all implant locations. When considering interaction factors, CT-Model 3 and SOT-Model 1 exhibited the highest and lowest mean AD and LD values, respectively. Model type, impression technique, and interaction factor all revealed significant effects on RMS values (P ≤ .001). CT-Model 3 and SOT-Model 1 presented the highest and lowest mean RMS values, respectively. CONCLUSION. Splinted-OT and IOS-Omnicam are recommended for multi-unit implant impressions to enhance trueness, potentially benefiting subsequent manufacturing stages.

Development of Manual Multi-Leaf Collimator for Proton Therapy in National Cancer Center (국립암센터의 양성자 치료를 위한 수동형 다엽 콜리메이터 개발)

  • Lee, Nuri;Kim, Tae Yoon;Kang, Dong Yun;Choi, Jae Hyock;Jeong, Jong Hwi;Shin, Dongho;Lim, Young Kyung;Park, Jeonghoon;Kim, Tae Hyun;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.250-257
    • /
    • 2015
  • Multi-leaf collimator (MLC) systems are frequently used to deliver photon-based radiation, and allow conformal shaping of treatment beams. Many proton beam centers currently make use of aperture and snout systems, which involve use of a snout to shape and focus the proton beam, a brass aperture to modify field shape, and an acrylic compensator to modulate depth. However, it needs a lot of time and cost of preparing treatment, therefore, we developed the manual MLC for solving this problem. This study was carried out with the intent of designing an MLC system as an alternative to an aperture block system. Radio-activation and dose due to primary proton beam leakage and the presence of secondary neutrons were taken into account during these iterations. Analytical calculations were used to study the effects of leaf material on activation. We have fabricated tray model for adoption with a wobbling snout ($30{\times}40cm^2$) system which used uniform scanning beam. We designed the manual MLC and tray and can reduce the cost and time for treatment. After leakage test of new tray, we upgrade the tray with brass and made the safety tool. First, we have tested the radio-activation with usually brass and new brass for new manual MLC. It shows similar behavior and decay trend. In addition, we have measured the leakage test of a gantry with new tray and MLC tray, while we exposed the high energy with full modulation process on film dosimetry. The radiation leakage is less than 1%. From these results, we have developed the design of the tray and upgrade for safety. Through the radio-activation behavior, we figure out the proton beam leakage level of safety, where there detects the secondary particle, including neutron. After developing new design of the tray, it will be able to reduce the time and cost of proton treatment. Finally, we have applied in clinic test with original brass aperture and manual MLC and calculated the gamma index, 99.74% between them.

A Study on the Fitness of Adjustable Dental Impression Trays on the Chinese and Japanese (중국인과 일본인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구)

  • Kang, Han-Joong;Lee, Jin-Han;Choi, Jong-In;Lee, In-Seop;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.175-184
    • /
    • 2008
  • Purpose: This study was designed to investigate the fitness of adjustable dental impression trays on the Chinese and the Japanese. Material and methods: Initial design of the adjustable dental trays was developed from the results of the dental arch size of Korean adults. This design was applied to the CAD-CAM process in order to create tray model samples. Simple silicon-base molds were then replicated based on these sample models. Polyurethane injection into the silicon- base molds completed the process of creating a large number of test products. 60 Chinese dental students (male:30, female:30) from the Shanghai Second Medical University and 60 Japanese alumni from the Kumamoto high school (male:30, female:30) were selected for taking irreversible hydrocolloid impression with these trays. The width and length of the impression body were measured on several measuring points by Vernier caliper. The results were analyzed statistically to evaluate the fitness of the trays. Results: 1. Uniform impression material thickness was achieved on the Chinese and Japanese by controlling the width of the tray using stops and beveled guides. The material thickness was generally within the range of 3 mm to 6 mm. 2. In the maxillary tray of the Chinese, average thickness of the impression material of the labial vestibule of the incisal teeth was 6.2 mm, the canine was 5.9 mm and the midpalatal part 10.5 mm and the posterior palatal part 9.7 mm. These were relatively large values. 3. In the mandibular tray of the Chinese, average length of the impression material of the lingual vestibule of first, second premolar contact point was 8.9 mm, the incisal teeth was 7.8 mm and thickness of the labial part of canine was 6.8 mm and premolars 7.0 mm. These were relatively large values. 4. In the maxillary tray of the Japanese, average thickness of the impression material of the labial vestibule of the incisal teeth was 7.4 mm, the canine was 7.7 mm and the midpalatal part 9.1 mm. These were relatively large values. 5. In the mandibular tray of the Japanese, average thickness of the impression material of the labial vestibule of first, second premolar contact point was 8.4 mm, and thickness of the labial part of canine was 7.4 mm. These were relatively large values. Conclusion: This adjustable dental tray shows good accuracy to Korean because it was designed by the analysis of the dental arch size of Korean adult model. With this result, it can be applied to Chinese and Japanese, we can take more easy and accurate dental impressions.

Development of Automatic Loading Equipment of Seedling Tray for Automatic Process of Raising Seedlings in Plant Factory (식물공장 육묘공정 자동화를 위한 육묘트레이 자동적재장치 개발)

  • Park, Sang-Min;Min, Young-Bong;Lee, Gong-In;Kim, Dong-Ouk;Kang, Dong-Hyun;Moon, Sung-Dong
    • Journal of agriculture & life science
    • /
    • v.45 no.5
    • /
    • pp.105-113
    • /
    • 2011
  • This study was carried out to develop an automatic loading equipment that can load seedling trays on loading position of the seedling bed driving on enclosed-type rail installed for interconnecting each process of raising seedlings in plant factory. The experiment of transferring the seedling tray by monorail pusher was carried out to figure out the required transfer force and problems during push type device of transporting the plastic seedling trays, that has completed its sowing process, which are installed onto the board of different materials. From the results of this experiment, the loading equipment which can exactly load three of the seedling trays orderly on the loading position of the seedling bed was designed and made. When three sowed trays on every board are transferred by pusher with the speed is at 30 cm/s, the maximum peak transfer force with maximum overshooting at initial transient state and the maximum transfer force at stead state are were respectively 32.8 N, 29.4 N on rubber board, 29.7 N, 22.5 N on a wooden board, 26.9 N, 19.6 N on a acrylic board, and 27.6 N, 19.1 N on an iron board. Changes in the transfer force occurred its maximum at the moment when the pusher collided with the tray, after the collision gradually decreased until it became stable. When two or three trays placed it in order of widthwise are transferred, it is occurred the overlapping of the tray's external bracket. The developed automatic loading equipment with PLC controller did not make any operation error through 100 times of tests, its maximum seedling tray loading speed was 2 sec/tray and its maximum error of transferred location of the tray was 0.5 cm.

The study of the fluoridation effect via individual tray compared with other methods (개인 트레이를 이용한 불소도포 효과에 관한 실험적 연구)

  • Cho, Byeng-Ken;Seo, Eun-Ju
    • Journal of Korean society of Dental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.251-260
    • /
    • 2001
  • The purpose of this article was to compare the fluoridation effect via individual tray with other professional methods. In oder to compare the fluoridation effect, 40 extracted human teeth was divided into 4 groups(each group was composed of 10 teeth) and the surface hardness of each group was tested in untreated, after fluoridation, after fluoridation and etching by 10% lactic acids. group I: no fluoridation(control) group II : fluoridation with 123%APF group III : fluoridation by iontophoresis with 2% NaF group IV : fluoridation by individual tray with 4% SnF2 gel Surface hardness was measured with Micro hardness tester(Shimadzu Co. Japan), Data analysis was conducted using the repeated measures ANOVA test. The results were as follows: 1. Four tested groups demonstrated nearly the same SMH in extracted state. 2. The SMH after fluoridation showed $330.57{\pm}139.09kg/mm^2$ in group IV, $221.79{\pm}187.48kg/mm^2$ in group II, $186.43{\pm}53.13kg/mm^2$ in group III. So the SMH of group IV, II were was significantly increased(p<0.01). 3. The SMH of group II, III, IV after acid etching was higher than the control group(p<0.01). 4. The SMH between group II, III, and IV after acid etching was not different significantly.

  • PDF

Development of a Vegetable Transplanting Robot

  • Kang, Dong-Hyeon;Kim, Dong-Eok;Lee, Gong-In;Kim, You-Ho;Lee, Hye-Jin;Min, Young-Bong
    • Journal of Biosystems Engineering
    • /
    • v.37 no.3
    • /
    • pp.201-208
    • /
    • 2012
  • Purpose: This study was conducted to develop a vegetable transplanting robot which transplants seedlings from a nursery tray to a plant pot using its four fingers. Method: The robot consists of the transplanting part, nursery tray moving part, plant pot moving part, main frame and controller. Two moving parts are controlled by the photo sensor and servo motor. The transplanting part was composed with two components; transporting device using E-MY2H(SMC Corp., Japan) for controlling finger position accurately and finger for transplanting the seedling. Results: Head lettuce using the transplanting robot was transplanted in 21 days after sowing based upon the seed shape measurement and removing examination. The optimal finger shape was thin pin type because it caused minimum damage to the roots of seedlings. Conclusions: The four inclined pin type was applied to remove the seedlings from the nursery tray. In addition, the transplanting capacity of the developed robot was 2800 pots per hour and the rate of success was 99% and above.

The design concept of the cubicle to improve freezing performance for high speed train (고속열차 배전반의 냉각성능 신뢰성 향상 방법에 대한 연구)

  • Choi, Kwon-Hee;Jeong, Byung-Ho;Lee, Byung-Seok;Park, Jong-Hun;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.905-910
    • /
    • 2007
  • The cubicle of high speed train is the equipment where the important train- operating equipments are concentrated, so it requires the higher safety and reliability than any other equipment. Recently, the power car cubicle of KTX-II is, basically similar to that of KTX-I and HSR350x in its size, but consequently, as more sophisticated ATP/ATC and other parts are added, the order company points out the problem of rising temperature in summer. Especially, the interpretation about the possibility of guaranteeing the minimum freezing performance becomes necessary, when Fan Tray is out of order. This paper presents the method of improving the freezing performance while minimizing the effect of dust, and the method of guaranteeing the present freezing performance by the best arrangement of Fan Tray, when Fan Tray is out of order. And as a method of verifying this, we would like to predict the pressure, speed of a running fluid and temperature distribution of cubicle through the flow analysis.

  • PDF

Effect of Fertilizer Levels and Shading Rate on Seeding Growth of Thalictrum Species Native to Korea (시비수준과 차광처리가 자생 Thalictrum 속 식물의 유묘생장에 미치는 영향)

  • Lee, Wan-Hee;Lee, Seung-Youn;Kang, Jung-Hwa;Lee, Taek-Joo;Kim, Ki-Sun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.1
    • /
    • pp.83-89
    • /
    • 2015
  • Thalictrum species belongs to the Ranunculaceae and are perennial landscape plants which are available in the garden and potted plants. This experiment was conducted to find out the basic data for the growth effects of fertilizer levels and shading rate in seedling plug cell tray in the Thalictrum rochebrunianum, T. uchiyamai and T. coreanum. For T. rochebrunianum and T. uchiyamai, growth increased by all fertilizer level treatments as compared to non-treatment. Hyponex 1000 times of treatment showed the highest growth. All growth increased in 35% shading as compared to other treatments for T. rochebrunianum and T. coreanum. But, for T. uchiyamai growth increased in 55% shading. In general, growth of three Thalictrum species was worse in 75% shading, as compared to other shading rates. Based on the results, Thalictrum species seedling can be produced by 35-55% shading and fertilization of Hyponex 1000 times by using plug tray.

ACCURACY OF STONE CAST PRODUCED BY ADJUSTABLE DENTAL IMPRESSION TRAY (가변형 치과 인상용 트레이로 제작된 모형의 재현성에 관한 연구)

  • Eom Sang-Ho;Oh Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.453-465
    • /
    • 2005
  • Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and methods: The metal stock, individual, and adjustable stock trays were used for 60 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a vinyl polysiloxane impressions and allowed to set for one hour. The master model and the duplicated casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software(CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results : There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch and the diagonal arch length and arch length on one side of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study cast produced by them.

Study on Automation of Integrated Seedling Production System - Planting Device- (종합공동육묘장의 설비 자동화에 관한 연구 -파종시스템-)

  • 최창현;노광모;이규창;김재민
    • Journal of Biosystems Engineering
    • /
    • v.21 no.2
    • /
    • pp.123-133
    • /
    • 1996
  • An automatic drum seeder was developed to improve the seeding operation. It consisted of a conveyor to transfer seedling trays, a seed-hopper to supply seeds, a drum to drop seeds on the tray, and an air blower to remove extra seeds. A photo sensor was used to detect the transfer of seedling trays, and its signal was fed into microcomputer which operated a stepping motor driving the drum. The seeds were adhered to the surface of drum by vacuum pressure, and were dropped into tray cells by compressed air. An air connection unit was devised to alternate between vacuum pressure and compressed air. A control program for the system, written in C language, could operate the drum at the given number of revolutions and revolutions per minute. The results showed that the air connection unit could operate well and the seeds were dropped satisfactorily into tray cells. In case of cabbage and perilla seeds, which are regular and spherical shape, the missing rate was low and the single seeding rate was more than 97%. Low missing rate and high multiple seeding rate were observed in lettuce seeds which have narrow ends with tight weight. The missing rate of pepper seed was very high because of heavy weight and irregular shape. To improve the performance of the seeder, adjustment of vacuum pressure based upon shape and weight of the seeds, careful selection of the material of drum, maintenance of consistent air blower pressure, and replacement of stepping motor to DC motor are recommended.

  • PDF