• 제목/요약/키워드: tray

검색결과 580건 처리시간 0.027초

Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorations

  • Ozay Onoral;Sevcan Kurtulmus-Yilmaz;Dilem Toksoy;Oguz Ozan
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권6호
    • /
    • pp.290-301
    • /
    • 2023
  • PURPOSE. The study aimed to determine the influence of implant angulation on the trueness of multi-unit implant impressions taken through different techniques and strategies. MATERIALS AND METHODS. As reference models, three partially edentulous mandibular models (Model 1: No angulation; Model 2: No angulation for #33, 15-degree distal angulation for #35 and #37; Model 3: No angulation for #33, 25-degree distal angulation for #35 and #37) were created by modifying the angulations of implant analogues. Using a lab scanner, these reference models were scanned. The obtained data were preserved and utilized as virtual references. Three intraoral scanning (IOS) strategies: IOS-Omnicam, ISO-Quadrant, and IOS-Consecutive, as well as two traaditional techniques: splinted open tray (OT) and closed tray (CT), were used to create impressions from each reference model. The best-fit alignment approach was used to sequentially superimpose the reference and test scan data. Computations and statistical analysis of angular (AD), linear (LD), and 3D deviations (RMS) were performed. RESULTS. Model type, impression technique, as well as interaction factor, all demonstrated a significant influence on AD and LD values for all implant locations (P < .05). The Model 1 and SOT techniques displayed the lowest mean AD and LD values across all implant locations. When considering interaction factors, CT-Model 3 and SOT-Model 1 exhibited the highest and lowest mean AD and LD values, respectively. Model type, impression technique, and interaction factor all revealed significant effects on RMS values (P ≤ .001). CT-Model 3 and SOT-Model 1 presented the highest and lowest mean RMS values, respectively. CONCLUSION. Splinted-OT and IOS-Omnicam are recommended for multi-unit implant impressions to enhance trueness, potentially benefiting subsequent manufacturing stages.

국립암센터의 양성자 치료를 위한 수동형 다엽 콜리메이터 개발 (Development of Manual Multi-Leaf Collimator for Proton Therapy in National Cancer Center)

  • 이누리;김태윤;강동윤;최재혁;정종휘;신동호;임영경;박정훈;김태현;이세병
    • 한국의학물리학회지:의학물리
    • /
    • 제26권4호
    • /
    • pp.250-257
    • /
    • 2015
  • 양성자 치료를 위해서는 Snout이 부착된 받침대(gantry)를 사용하는데 빔의 형태를 만들기 위해 환자 종양의 크기와 거리에 맞게 황동 차폐체(aperture)가 많이 사용된다. 또한 빔의 거리를 보정하기 위해 PMMA를 이용한 거리 보상체도 사용된다. 이렇게 황동으로 만들어진 차폐체의 경우 가공하는데 많은 시간이 소요되며 비용 발생이 높다. 또한 치료 사용되었던 차폐체의 방사선 노출에 따라 재사용이 어렵다. 이러한 단점을 보안하기 위해 황동 차폐체 대신 X-선 치료에서 사용되는 수동형 다엽 콜리메이터 시스템을 도입하였다. 수동형 다업 콜리메이터는 여러 개의 황동판을 조립하여 차폐체를 제작하는 방식이다. 본 연구는 제작된 수동형 다엽 콜리메이터의 방사화 실험 및 필름을 이용해 선량측정을 진행하였다. 다엽 콜리메이터를 투과한 2차 발생 선량 1% 이하였으며, 여러 번의 230 MeV의 빔에서도 방사화가 2시간 이내에서 감소하였다. 이렇게 개발된 수동형 다엽 콜리메이터를 임상에 적용하여 일반 차폐체와 수동형 다엽 콜리메이터를 감마지표 분석을 했을 시 99.74%의 높은 일치도가 측정되었다. 또한, 일반 황동 차폐체에 비해 수동형 다엽 콜리메이터를 제작하는데 소요되는 비용과 시간을 1/10 이상 단축시킬 수 있다. 개발된 수동형 다엽 콜리메이터는 성공적으로 양성자 환자치료에 사용하고 있다.

중국인과 일본인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구 (A Study on the Fitness of Adjustable Dental Impression Trays on the Chinese and Japanese)

  • 강한중;이진한;최종인;이인섭;동진근
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.175-184
    • /
    • 2008
  • 연구목적: 본 연구는 가변형 트레이 개발의 일환으로 그 시제품을 제작하고 비가역성 수성 콜로이드 인상재를 사용하여 중국인과 일본인에서 인상채득 시 트레이의 구강 내 적합성를 알아보고자 하였다. 연구재료 및 방법: 가변형 트레이는 한국 성인 악궁의 크기 분석결과를 기본으로 하여 설계하였으며, 먼저 CAD-CAM 작업을 통하여 견본 모형을 제작한 후, 이를 똑같이 복제한 실리콘 간이금형을 만들었다. 그리고 이 금형에 polyurethane을 주입하여 다수의 시제품을 완성하였다. 시제품을 이용하여 중국인으로는 상해 제2의과대학교 구강의학원 학생 60명 (남자 30명, 여자 30명)을 대상으로 하였고, 일본인으로는 일본 구마모토 고등학교 졸업생 60명 (남자 30명, 여자 30명)을 대상으로 인상채득을 실시하고, 측정부위별로 인상체의 두께와 길이를 측정한 후 통계처리를 하여 그 적합성을 평가하였다. 결과: 1. 중국인과 일본인 모두 스탑과 경사면에 의해 트레이의 폭이 적절히 조절되어 대체적으로 3-6mm의 균일한 인상체의 두께를 얻을 수 있었다. 2. 중국인의 상악 트레이에서는 전치 순측 변연부에서 두께가 6.2mm, 견치 순측 변연부에서 두께가 5.9mm, 구개부 중앙은 10.5 mm, 구개부 후방은 9.7mm 높이로 비교적 인상체의 두께가 크게 측정되었다. 3. 중국인의 하악 트레이에서는 제1, 2소구치 접촉점 설측 변연부에서 인상체의 길이가 8.9mm, 전치 설측 변연부에서 7.2mm로 길게 나타났으며, 견치 순측 6.8mm, 소구치 순측 7.0mm로 인상체의 두께가 크게 측정되었다. 4. 일본인의 상악 트레이에서는 전치 순측 변연부에서 두께가 7.4mm, 견치 순측 변연부에서 7.7mm, 구개부 중앙은 9.1mm 높이로 인상체의 두께가 비교적 크게 측정되었다. 5. 일본인의 하악 트레이에서는 견치 순측 7.4mm, 제1, 2소구치 접촉점 순측 변연부 8.4mm로 인상체의 두께가 크게 측정되었다. 결론: 본 가변형 치과 인상용 트레이는 한국인 모형 계측치를 바탕으로 설계되어 한국인에서 적합성이 우수하며, 본 실험의 결과 중국인과 일본인에서도 적합성이 좋아 본 트레이를 범용하여 쉽고 정확한 인상채득을 할 수 있을 것이다.

식물공장 육묘공정 자동화를 위한 육묘트레이 자동적재장치 개발 (Development of Automatic Loading Equipment of Seedling Tray for Automatic Process of Raising Seedlings in Plant Factory)

  • 박상민;민영봉;이공인;김동억;강동현;문성동
    • 농업생명과학연구
    • /
    • 제45권5호
    • /
    • pp.105-113
    • /
    • 2011
  • 본 연구는 식물공장의 각 공정 간을 연결하는 육묘라인을 폐쇄형 레일로 설정하고, 그 레일 상에서 구름바퀴 이동을 하는 육묘베드가 있고, 이 육묘 베드위의 일정위치에 육묘트레이를 자동으로 올려놓는 자동적재장치를 개발하기 위하여 수행되었다. 이 장치의 개발을 위한 기초시험으로 바닥재 위에 육묘트레이를 올려놓고 밀기이송을 하는 시험을 실시하고, 밀기이송력의 변화를 측정 분석하여 최적의 육묘트레이 자동적재장치를 개발하였다. 바닥 위에 파종완료한 트레이를 올려놓고 밀기 이송을 할 때 최대 이송력은 이송속도 30 cm/s에서 트레이 3개를 이송할 때로 초기이송시점에서 최대 피크이송력과 초기 과도상태 이후 최대 정상상태 이송력이 각각 바닥재료가 고무판에서는 32.8 N, 29.4 N, 목재판 29.7 N, 22.5 N, 아크릴판 26.9 N, 19.6 N, 철판 27.6 N, 19.1 N으로 나타났다. 이 이송력의 변화는 모노레일 컨베이어가 트레이와 충돌 직후 최대로 발생했으며, 이후 점차 줄어들어 안정적으로 변화되는 것으로 나타났다. 트레이를 2개 이상 맞대어 밀기이송 시 트레이 외각 받침날의 겹침현상이 일어났다. 최종적으로 개발한 육묘트레이 적재이송장치는 100회의 작동시험 결과 작동에러는 없었으며, 최대 육묘트레이 적재이송 작업속도는 2초/매, 트레이 이송위치 최대오차는 0.5 cm로 나타났다.

개인 트레이를 이용한 불소도포 효과에 관한 실험적 연구 (The study of the fluoridation effect via individual tray compared with other methods)

  • 조병근;서은주
    • 한국치위생학회지
    • /
    • 제1권2호
    • /
    • pp.251-260
    • /
    • 2001
  • The purpose of this article was to compare the fluoridation effect via individual tray with other professional methods. In oder to compare the fluoridation effect, 40 extracted human teeth was divided into 4 groups(each group was composed of 10 teeth) and the surface hardness of each group was tested in untreated, after fluoridation, after fluoridation and etching by 10% lactic acids. group I: no fluoridation(control) group II : fluoridation with 123%APF group III : fluoridation by iontophoresis with 2% NaF group IV : fluoridation by individual tray with 4% SnF2 gel Surface hardness was measured with Micro hardness tester(Shimadzu Co. Japan), Data analysis was conducted using the repeated measures ANOVA test. The results were as follows: 1. Four tested groups demonstrated nearly the same SMH in extracted state. 2. The SMH after fluoridation showed $330.57{\pm}139.09kg/mm^2$ in group IV, $221.79{\pm}187.48kg/mm^2$ in group II, $186.43{\pm}53.13kg/mm^2$ in group III. So the SMH of group IV, II were was significantly increased(p<0.01). 3. The SMH of group II, III, IV after acid etching was higher than the control group(p<0.01). 4. The SMH between group II, III, and IV after acid etching was not different significantly.

  • PDF

Development of a Vegetable Transplanting Robot

  • Kang, Dong-Hyeon;Kim, Dong-Eok;Lee, Gong-In;Kim, You-Ho;Lee, Hye-Jin;Min, Young-Bong
    • Journal of Biosystems Engineering
    • /
    • 제37권3호
    • /
    • pp.201-208
    • /
    • 2012
  • Purpose: This study was conducted to develop a vegetable transplanting robot which transplants seedlings from a nursery tray to a plant pot using its four fingers. Method: The robot consists of the transplanting part, nursery tray moving part, plant pot moving part, main frame and controller. Two moving parts are controlled by the photo sensor and servo motor. The transplanting part was composed with two components; transporting device using E-MY2H(SMC Corp., Japan) for controlling finger position accurately and finger for transplanting the seedling. Results: Head lettuce using the transplanting robot was transplanted in 21 days after sowing based upon the seed shape measurement and removing examination. The optimal finger shape was thin pin type because it caused minimum damage to the roots of seedlings. Conclusions: The four inclined pin type was applied to remove the seedlings from the nursery tray. In addition, the transplanting capacity of the developed robot was 2800 pots per hour and the rate of success was 99% and above.

고속열차 배전반의 냉각성능 신뢰성 향상 방법에 대한 연구 (The design concept of the cubicle to improve freezing performance for high speed train)

  • 최권희;정병호;이병석;박종훈;이종우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.905-910
    • /
    • 2007
  • The cubicle of high speed train is the equipment where the important train- operating equipments are concentrated, so it requires the higher safety and reliability than any other equipment. Recently, the power car cubicle of KTX-II is, basically similar to that of KTX-I and HSR350x in its size, but consequently, as more sophisticated ATP/ATC and other parts are added, the order company points out the problem of rising temperature in summer. Especially, the interpretation about the possibility of guaranteeing the minimum freezing performance becomes necessary, when Fan Tray is out of order. This paper presents the method of improving the freezing performance while minimizing the effect of dust, and the method of guaranteeing the present freezing performance by the best arrangement of Fan Tray, when Fan Tray is out of order. And as a method of verifying this, we would like to predict the pressure, speed of a running fluid and temperature distribution of cubicle through the flow analysis.

  • PDF

시비수준과 차광처리가 자생 Thalictrum 속 식물의 유묘생장에 미치는 영향 (Effect of Fertilizer Levels and Shading Rate on Seeding Growth of Thalictrum Species Native to Korea)

  • 이완희;이승연;강정화;이택주;김기선
    • 한국환경복원기술학회지
    • /
    • 제18권1호
    • /
    • pp.83-89
    • /
    • 2015
  • Thalictrum species belongs to the Ranunculaceae and are perennial landscape plants which are available in the garden and potted plants. This experiment was conducted to find out the basic data for the growth effects of fertilizer levels and shading rate in seedling plug cell tray in the Thalictrum rochebrunianum, T. uchiyamai and T. coreanum. For T. rochebrunianum and T. uchiyamai, growth increased by all fertilizer level treatments as compared to non-treatment. Hyponex 1000 times of treatment showed the highest growth. All growth increased in 35% shading as compared to other treatments for T. rochebrunianum and T. coreanum. But, for T. uchiyamai growth increased in 55% shading. In general, growth of three Thalictrum species was worse in 75% shading, as compared to other shading rates. Based on the results, Thalictrum species seedling can be produced by 35-55% shading and fertilization of Hyponex 1000 times by using plug tray.

가변형 치과 인상용 트레이로 제작된 모형의 재현성에 관한 연구 (ACCURACY OF STONE CAST PRODUCED BY ADJUSTABLE DENTAL IMPRESSION TRAY)

  • 엄상호;오상천
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.453-465
    • /
    • 2005
  • Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and methods: The metal stock, individual, and adjustable stock trays were used for 60 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a vinyl polysiloxane impressions and allowed to set for one hour. The master model and the duplicated casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software(CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results : There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch and the diagonal arch length and arch length on one side of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study cast produced by them.

종합공동육묘장의 설비 자동화에 관한 연구 -파종시스템- (Study on Automation of Integrated Seedling Production System - Planting Device-)

  • 최창현;노광모;이규창;김재민
    • Journal of Biosystems Engineering
    • /
    • 제21권2호
    • /
    • pp.123-133
    • /
    • 1996
  • An automatic drum seeder was developed to improve the seeding operation. It consisted of a conveyor to transfer seedling trays, a seed-hopper to supply seeds, a drum to drop seeds on the tray, and an air blower to remove extra seeds. A photo sensor was used to detect the transfer of seedling trays, and its signal was fed into microcomputer which operated a stepping motor driving the drum. The seeds were adhered to the surface of drum by vacuum pressure, and were dropped into tray cells by compressed air. An air connection unit was devised to alternate between vacuum pressure and compressed air. A control program for the system, written in C language, could operate the drum at the given number of revolutions and revolutions per minute. The results showed that the air connection unit could operate well and the seeds were dropped satisfactorily into tray cells. In case of cabbage and perilla seeds, which are regular and spherical shape, the missing rate was low and the single seeding rate was more than 97%. Low missing rate and high multiple seeding rate were observed in lettuce seeds which have narrow ends with tight weight. The missing rate of pepper seed was very high because of heavy weight and irregular shape. To improve the performance of the seeder, adjustment of vacuum pressure based upon shape and weight of the seeds, careful selection of the material of drum, maintenance of consistent air blower pressure, and replacement of stepping motor to DC motor are recommended.

  • PDF