• Title/Summary/Keyword: transverse measurements

Search Result 187, Processing Time 0.022 seconds

A CLINICAL STUDY ON ANCHORAGE CONTROL OF MOLAR ANCHORING SPRING(MAS) DURING RETRACTION OF THE MAXILLARY CANINE (상악 견치 후방견인시 MAS(Molar Anchoring Spring)의 저항원 조절에 대한 임상적 연구)

  • Kim, Sun-Min;Rhee, Joon-No;Row, Joon;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.269-276
    • /
    • 1998
  • In maxillary canine retraction by means of sliding mechanics, we designed MAS(molar anchoring spring) to prevent anchorage loss and uncontrolled tipping of tooth movement and have applied it in clinical cases. The anchorage control of the maxillary first molar and type of tooth movement of the maxillary canine were studied in 31 subjects. The measurements were made on cephalograms, orthopantomograms and dental casts. The obtained results were as follows. 1. In case of the maxillary first molar, there was a little sagittal anchorage loss, but there was no vertical & transverse anchorage loss. 2. In case of the maxillary canine, there was distal tipping movement and also there was a little intrusion tendency.

  • PDF

THE INFLUENCE OF IMPRESSION TRAYS ON THE ACCURACY OF THE STONE CASTS POURED FROM COMPLETE-ARCH IMPRESSIONS (전악인상채득시 인상용 트레이가 경석고 모형의 정확도에 미치는 영향)

  • Ryu Su-In;Chang Ik-Tae;Kim Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.1
    • /
    • pp.1-14
    • /
    • 1992
  • The purpose of this study was to evaluate the accuracy of reproduction of stone casts made from complete-arch impressions using different trays. The trays used were : 1) nonperforated custom tray, 2) perforated custom tray, 3) nonperforated Rim-Lock tray, 4) perforated stock tray. Impressions were made from an dentulous acrylic resin model with metal inserts in first premolars and second molars. Transverse distance, sagittal distance and diagonal distance were measured using 4 landmarks. Measurements were made by using 3 dimensional measuring machine. The impression material used was an addition silicone. Impressions were poured at once with a Type IV dental stone. Data were analyzed using ANOVA and student t-test with a sample size of five. The results were as follows : 1. There were statistical differences in amount of dimensional change in according to the tray types. In amount of mean dimensional change, perforated custom tray was the first smallest, nonperforated custom tray was the second, nonperforated Rim-Lock tray and perforated stock tray were the largest. 2. There were statistical differences in amount of dimensional change between nonperforated custom tray and nonperforated Rim-Lock tray, and between perforated custom tray perforated stock tray. 3. There were satistical differences in amount of dimensional change between nonperforated custom tray and perforated custom tray, but there was not a statistical difference between nonperforated Rim-Lock tray and perforated stock tray. 4. There was not a statistical difference in amount of dimensional change between upper and lower arch in all tray types.

  • PDF

Optical power splitters and optical intensity modulators utilizing Strain-Optic Waveguides of LiNbO3 (LiNbO3의 스트레인광학형 광도파로를 이용한 세기 광 변조기와 광 파워 분배기)

  • 정홍식
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.1
    • /
    • pp.38-43
    • /
    • 2003
  • Fabrication process of strain-induced channel waveguides in $LiNbO_3$ was developed using strain-optic effect and compressional strain due to ~1.4 $\mu\textrm{m}$ surface Mo/Pt metal film. Characterization of the channel waveguides revealed a single transverse and depth mode in both TE and TM polarizations. Measurements showed total insertion loss of 6.2 and 7.7 ㏈/cm for TM and TE polarizations. respectively. Electro-optic intensity modulators with 11 mm long electrode length and 21 $\mu\textrm{m}$ electrode gap at $\lambda$ = 1.15 ${\mu}{\textrm}{m}$have been produced in $LiNbO_3$ substrates using strain-induced channel waveguides. Modulation depth of 100% at $\pi$-radian voltage of 16.1V has been demonstrated. Also, 1$\times$2 on/off power splitters at $\lambda$ = 0.63 $\mu\textrm{m}$ have been produced using strain-induced channel waveguides. On/off voltage of $\pm$ 25V has been demonstrated.

A Study on Design and Application of Tissue Compensator for 6MV X-rays (6MV X-선에 대한 조직 보상체의 제작 및 응용에 관한 연구)

  • Chai Kyu Young;Choi Eun Kyung;Chung Woong Ki;kang Wee Saing;Ha Sung Whan;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.123-132
    • /
    • 1989
  • A radiation beam incident on an irregular or sloping surface produces the non-uniformity of absorded dose. The use of a tissue compensator can partially correct this dose inhomogeneity. The tissue compensator is designed based on the patient's three dimensional contour. After required compensator thickness was determined according to tissue deficit at $25cm\pm25cm$ field size, 10cm depth for 6MV x-rays, tissue deficit was mapped by isoheight technique using laser beam system. Compensator was constructed along the designed model using 0.8mm lead sheet or 5mm acryl plate. Dosimetric verification were peformed by film dosimetry using humanoid phantom. Dosimetric measurements were normalized to central axis full phantom readings for both compensated and non-compensated field. Without compensation, the percent differences in absorbed dose ranged as high as $12.1\%$ along transverse axis, $10.8\%$ along vertical axis. With the tissue compensators in place, the difference was reduced to $0\~43\%$ Therefore, it can be concluded that the compensator system constructed by isoheihnt technique can produce good dose distribution with acceptible inhomogeneity, and such compensator system can be effectively applied to clinical radiotherapy.

  • PDF

FDTD Analysis of Lossy Multiconductor Transmission Lines Terminated in Linear Loads (선형소자로 종단된 손실이 있는 다중 전송선의 FDTD 해석)

  • 박범준;주재철;이형영;박동철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.3
    • /
    • pp.419-428
    • /
    • 2000
  • Multiconductor transmission line(MTL) equations are solved by FDTD(Finite-Difference Time-Domain) method to predict crosstalk and fields to transmission line coupling on lossy multiconductor transmission lines terminated in arbitrary linear loads. Skin effect losses as well as dc losses are included in the analysis. In order to increase computational efficiency, the convolution integral of internal impedance of conductors and the line currents is computed by using Prony method. For boundary conditions of MTLs terminated in linear loads, state-variable formulation is adopted. The simulated results by FDTD method are compared with the measured ones obtained by using TEM cell. The predictions are in good agreement with the measurements. In addition, it has been found that skin effect losses as well as dc losses of the conductors should be included for accurate predictions on relatively high loss transmission lines such as PCB. It has also been found that dc losses and skin-effect losses affect late-time responses and early-time responses, respectively.

  • PDF

Does hyrax expansion therapy affect maxillary sinus volume? A cone-beam computed tomography report

  • Darsey, Drew M.;English, Jeryl D.;Kau, Chung H.;Ellis, Randy K.;Akyalcin, Sercan
    • Imaging Science in Dentistry
    • /
    • v.42 no.2
    • /
    • pp.83-88
    • /
    • 2012
  • Purpose : The aim of this study was to investigate the initial effects of maxillary expansion therapy with Hyrax appliance and to evaluate the related changes in maxillary sinus volume. Materials and Methods : Thirty patients (20 females, 10 males; 13.8 years) requiring maxillary expansion therapy, as part of their comprehensive orthodontic treatment, were examined. Each patient had cone-beam computed tomography (CBCT) images taken before (T1) and after (T2) maxillary expansion therapy with a banded Hyrax appliance. Multiplanar slices were used to measure linear dimensions and palatal vault angle. Volumetric analysis was used to measure maxillary sinus volumes. Student t tests were used to compare the pre- and post-treatment measurements. Additionally, differences between two age groups were compared with Mann-Whitney U test. The level of significance was set at p=0.05. Results : Comparison of pre-treatment to post-treatment variables revealed significant changes in the transverse dimension related to both maxillary skeletal and dental structures and palatal vault angle, resulting in a widened palatal vault (p<0.05). Hard palate showed no significant movement in the vertical and anteroposterior planes. Nasal cavity width increased on a mean value of 0.93mm(SD=0.23, p<0.05). Maxillary sinus volume remained virtually stable. No significant age differences were observed in the sample. Conclusion : Hyrax expansion therapy did not have a significant impact on maxillary sinus volume.

Numerical Analysis of Flow Characteristics of a Twin-skeg Container Ship with Variation of Stern Hull Shape (쌍축 컨테이너선의 선미선형 변화에 따른 유동 특성에 대한 수치해석)

  • Kim, Hee-Taek;Van, Suak-Ho;Kim, Hyoung-Tae
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.44 no.6
    • /
    • pp.551-563
    • /
    • 2007
  • Numerical analysis for flow characteristics of a twin skeg container ship was carried out according to skeg vertical angles($0^{\circ}$, $10^{\circ}$, $20^{\circ}$) and skeg distances(16m, 20m, 24m) by using a commercial CFD code, FLUENT. Computed: pressure distributions, wake distributions and resistance coefficients have been compared with experimental and WAVIS results carried out by MOERI. Flow characteristics from numerical analysis such as nominal wake fractions, wake distribution and directions of the transverse vectors give good agreement with WAVIS results, even though there are quantitative discrepancy comparing with experimental measurements at the propeller plane. It is found that the better resistance performance can be obtained with the increase of the skeg vertical angle and the decrease of the skeg distance, which are mainly caused by viscous pressure resistance due to the skeg form and pressure recovery around the skeg. In addition, a vertical angle of the skeg gives more effect to the resistance coefficient comparing with the skeg distance. On the basis of results of the present study, it shows that numerical analysis using the commercial code, FLUENT, is useful and efficient tool for the evaluation of the complex stern hull form with twin-skegs.

Morphometric Study of the Korean Adult Pituitary Glands and the Diaphragma Sellae

  • Ju, Kyo-Sung;Bae, Hack-Gun;Park, Hyung-Ki;Chang, Jae-Chil;Choi, Soon-Kwan;Sim, Ki-Bum
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.1
    • /
    • pp.42-47
    • /
    • 2010
  • Objective: To investigate the morphometric characteristics of the pituitary gland and diaphragma sellae in Korean adults. Methods: Using the 33 formaline fixed adult cadavers (23 male, 10 female), the measurements were taken at the diaphragma sellae and pituitary gland. The authors investigated the relationship between dura and structures surrounding pituitary gland, morphometric aspects of pituitary gland and stalk, and morphometric aspect of central opening of diaphragma sellae. Results: The boundary between the lateral surface of pituitary gland and the medial wall of cavernous sinus was formed by the thin dural layer and pituitary capsule. The pituitary capsule adherent tightly to the pituitary gland was observed to continue from the diaphragma sellae. Mean width, length, and height of the pituitary gland were 14.3${\pm}$2.1, 7.9${\pm}$1.3, and 6.0${\pm}$0.9 mm in anterior lobes, and 8.7${\pm}$1.7, 2.9${\pm}$1.1, and 5.8${\pm}$1.0 mm in posterior lobes, respectively. Although all dimensions of anterior lobe in female were slightly larger than those in male, statistical significance was noted in only longitudinal dimension. The ratio of posterior lobe to the whole length of pituitary gland was about 27%. The mean thickness of pituitary stalk was 2 mm. The diaphragmal opening was 5 mm or more in 26 (78.8%) of 33 specimen. The opening was round in 60.6% of the specimen, and elliptical oriented in an anterior-posterior or transverse direction in 39.4%. Conclusion: These results provide the safe anatomical knowledge during the transsphenoidal surgery and may be helpful to access the possibility of the development of empty sella syndrome.

Three-dimensional assessment of the temporomandibular joint and mandibular dimensions after early correction of the maxillary arch form in patients with Class II division 1 or division 2 malocclusion

  • Coskuner, Hande Gorucu;Ciger, Semra
    • The korean journal of orthodontics
    • /
    • v.45 no.3
    • /
    • pp.121-129
    • /
    • 2015
  • Objective: This study aimed to assess three-dimensional changes in the temporomandibular joint positions and mandibular dimensions after correction of dental factors restricting mandibular growth in patients with Class II division 1 or division 2 malocclusion in the pubertal growth period. Methods: This prospective clinical study included 14 patients each with Class II division 1 (group I) and Class II division 2 (group II) malocclusions. The quad-helix was used for maxillary expansion, while utility arches were used for intrusion (group I) or protrusion and intrusion (group II) of the maxillary incisors. After approximately 2 months of treatment, an adequate maxillary arch width and acceptable maxillary incisor inclination were obtained. The patients were followed for an average of 6 months. Intraoral and extraoral photographs, plaster models, and cone-beam computed tomography (CBCT) images were obtained before and after treatment. Lateral cephalometric and temporomandibular joint measurements were made from the CBCT images. Results: The mandibular dimensions increased in both groups, although mandibular positional changes were also found in group II. There were no differences in the condylar position within the mandibular fossa or the condylar dimensions. The mandibular fossa depth and condylar positions were symmetrical at treatment initiation and completion. Conclusions: Class II malocclusion can be partially corrected by achieving an ideal maxillary arch form, particularly in patients with Class II division 2 malocclusion. Restrictions of the mandible in the transverse or sagittal plane do not affect the temporomandibular joint positions in these patients because of the high adaptability of this joint.

Ultrasound-guided Distance Measurements of Vertebral Structures for Lumbar Medial Branch Block (초음파 유도하에서의 요추부 후관절 내측지 차단술을 위한 주요 척추 구조물의 거리 측정)

  • Moon, Jin Cheon;Shim, Jae Kwang;Jo, Kwang Yun;Yoon, Kyung Bong;Kim, Won Oak;Yoon, Duck Mi
    • The Korean Journal of Pain
    • /
    • v.20 no.2
    • /
    • pp.111-115
    • /
    • 2007
  • Background: Selective diagnostic blocks of the medial branches of the dorsal primary ramus are usually performed under the guidance of fluoroscopic or computed tomography. Recently, however, ultrasound guidance has been suggested as an altemative method. In this study, the distances between the vertebral structures were measured and compared with the values measured using magnetic resonance imaging (MRI) to assess the clinical feasibility of using ultrasound-guided block in Korean patients. Methods: Five male and 15 female patients were enrolled in this study. The target point of the medial branch block in our study was the groove at the base of the superior articular process, We measured the depth from the skin to the target point at the transverse process (d-TP) and to the most superficial point of the superior articular process (d-AP). Results: The d-TP and d-AP values measured under ultrasound guidance were concordant with the values measured using MRI. Conclusions: The images of the bony landmarks obtained under ultrasound examination could be useful for ultrasound-guided lumbar medial branch block.