• Title/Summary/Keyword: transverse interval

Search Result 40, Processing Time 0.028 seconds

Inverse Offset Method for Adaptive Cutter Path Generation from Point-based Surface

  • Kayal, Prasenjit
    • International Journal of CAD/CAM
    • /
    • v.7 no.1
    • /
    • pp.21-30
    • /
    • 2007
  • The inverse offset method (IOM) is widely used for generating cutter paths from the point-based surface where the surface is characterised by a set of surface points rather than parametric polynomial surface equations. In the IOM, cutter path planning is carried out by specifying the grid sizes, called the step-forward and step-interval distances respectively in the forward and transverse cutting directions. The step-forward distance causes the chordal deviation and the step-forward distance produces the cusp. The chordal deviation and cusp are also functions of local surface slopes and curvatures. As the slopes and curvatures vary over the surface, different step-forward and step-interval distances are appropriate in different areas for obtaining the machined surface accurately and efficiently. In this paper, the chordal deviation and cusp height are calculated in consideration with the surface slopes and curvatures, and their combined effect is used to estimate the machined surface error. An adaptive grid generation algorithm is proposed, which enables the IOM to generate cutter paths adaptively using different step-forward and step-interval distances in different regions rather than constant step-forward and step-interval distances for entire surface.

Complete denture artificial teeth arrangement deformation in wax denture after festooning: deformation over time (총의치의 납의치 상에서 치은 형성 시행 후에 나타나는 시간에 따른 인공 치아 이 동에 대한 평가)

  • Lee, Sea-Han;Kwak, Young-Hun;Kim, Hee Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.262-269
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the deformation of the complete denture artificial teeth arrangement after festooning over time. Materials and Methods: 10 wax dentures of equal teeth arrangement and equal gingival contour were used in this study. Festooning of the wax dentures were conducted and 3D model scans were conducted every 10 minutes for 120 minutes. Interdental transverse distances were measured with the scanned images. Statistical analyses were performed with SPSS Ver. 22. 0. Results: Interdental transverse distance between teeth varied from 0.0999 mm to 0.1787 mm. Mean rate of deformation showed statistically significant change between the 40 - 50 minute interval and 50 - 60 minute interval and between the 50 - 60 minute interval and 60 - 70 minute interval. No statistically significant change of the mean rate of deformation was observed later on. Conclusion: Monitoring of the interdental transverse distance for 120 minute after festooning have shown the deformation and displacment of the artificial teeth arrangement. From after the 60 - 70 minute interval after festooning, the mean deformation showed no statistically significant change of the mean rate of deformation was observed. Within the limitations of this in vitro study results suggest that the final occlusal adjustment in wax denture before complete denture curing should be proceeded at least 60 minutes later after festooning.

Static and vibration analysis of thin plates by using finite element method of B-spline wavelet on the interval

  • Xiang, Jiawei;He, Zhengjia;He, Yumin;Chen, Xuefeng
    • Structural Engineering and Mechanics
    • /
    • v.25 no.5
    • /
    • pp.613-629
    • /
    • 2007
  • A finite element method (FEM) of B-spline wavelet on the interval (BSWI) is used in this paper to solve the static and vibration problems of thin plate. Instead of traditional polynomial interpolation, the scaling functions of two-dimensional tensor product BSWI are employed to construct the transverse displacements field. The method combines the accuracy of B-spline functions approximation and various basis functions for structural analysis. Some numerical examples are studied to demonstrate the proposed method and the numerical results presented are in good agreement with the solutions of other methods.

A study on the program development for optimizing the supply and exhaust port opening ratio in road tunnels with transverse ventilation system (횡류식 도로터널의 급배기구 개도율 최적화 프로그램 개발 연구)

  • Jo, Hyeong-Je;Chun, Kyu-Myung;Min, Dea-Kee;Kim, Jong-Won;Beak, Jong-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.517-532
    • /
    • 2017
  • The transverse ventilation system, commonly applied to urban tunnel, is necessary to be distributed with airflow uniformly. In this study, we developed a program that can optimize the opening ratio of ports to ensure ventilation performance of design criteria through a uniform airflow distribution even though ventilation interval becomes longer. And program's prediction performance was verified by comparison with TUNVEN DUCT program. For comparison, Semi-transverse ventilation system was applied. Both programs predicted a similar port size and air flow distribution, and the variation range of the calculated values was 11.71% and 1.36%, respectively. This program is very useful for port optimization design of transverse and semi-transverse ventilation system, because it is possible to analyze various tunnel lengths and supply/exhaust port installation conditions.

3-D Numerical Experiment for Estimation of Equivalent Resistance Coefficient due to Multi-piers : Effect of Transverse Intervals (상당저항계수식 산정을 위한 3차원 수치실험 : 횡방향 이격거리의 영향)

  • Kim, Hyeong-Seok;Choi, Jun-Woo;Ko, Kwang-Oh;Yoon, Sung-Bum
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.21 no.3
    • /
    • pp.216-223
    • /
    • 2009
  • A transverse drag interaction coefficient of the equivalent resistance coefficient formula for square multi-piers higher than water depth and arranged with equal intervals was studied. From the assumption that the energy loss due to drag interaction according to transverse intervals of resistance bodies is essentially identical to the energy loss due to thick orifice according to porosities, the transverse drag interaction coefficient was derived by employing the orifice's energy loss coefficient. The equivalent resistance coefficient formula including the drag interaction coefficient was compared with the numerical experiments using FLOW-3D, the performance of which was verified by Kim et al.(2008) in the experimental condition with the multi-piers. The comparisons showed good agreement and thus, the equivalent resistance coefficient formula, which does not only consider frictional resistance but also consider the multi-piers' drag resistance varied according to the intervals in longitudinal or transverse direction, was verified.

ESTIMATION OF ERRORS IN THE TRANSVERSE VELOCITY VECTORS DETERMINED FROM HINODE/SOT MAGNETOGRAMS USING THE NAVE TECHNIQUE

  • Chae, Jong-Chul;Moon, Yong-Jae
    • Journal of The Korean Astronomical Society
    • /
    • v.42 no.3
    • /
    • pp.61-69
    • /
    • 2009
  • Transverse velocity vectors can be determined from a pair of images successively taken with a time interval using an optical flow technique. We have tested the performance of the new technique called NAVE (non-linear affine velocity estimator) recently implemented by Chae & Sakurai using real image data taken by the Narrowband Filter Imager (NFI) of the Solar Optical Telescope (SOT) aboard the Hinode satellite. We have developed two methods of estimating the errors in the determination of velocity vectors, one resulting from the non-linear fitting ${\sigma}_{\upsilon}$ and the other ${\epsilon}_u$ resulting from the statistics of the determined velocity vectors. The real error is expected to be somewhere between ${\sigma}_{\upsilon}$ and ${\epsilon}_u$. We have investigated the dependence of the determined velocity vectors and their errors on the different parameters such as the critical speed for the subsonic filtering, the width of the localizing window, the time interval between two successive images, and the signal-to-noise ratio of the feature. With the choice of $v_{crit}$ = 2 pixel/step for the subsonic filtering, and the window FWHM of 16 pixels, and the time interval of one step (2 minutes), we find that the errors of velocity vectors determined using the NAVE range from around 0.04 pixel/step in high signal-to-noise ratio features (S/N $\sim$ 10), to 0.1 pixel/step in low signa-to-noise ratio features (S/N $\sim$ 3) with the mean of about 0.06 pixel/step where 1 pixel/step corresponds roughly to 1 km/s in our case.

Muscle Ultrastructural Changes by Lysosomal Enzymes -2. Scanning Electron Microscopic Studies- (Lysosomal Enzyme에 의(依)한 근육조직(筋肉組織)의 변화(變化) -제(第)2보(報) Scanning Electron Microscopy에 의(依)한 고찰(考察)-)

  • Cho, Moo-Je;Yoon, Tae-Gyu;Bailey, Milton E.
    • Korean Journal of Food Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.36-45
    • /
    • 1978
  • Surface ultrastructural changes in endomysial connective tissue, sarcolemma and transverse ridges of bovine psoas muscle produced by leukocyte lysosomal enzymes in vitro at different pH (pH 7.0 and 4.0), temperature (37 and $4^{\circ}C$) and time interval (12, 24 hours at $37^{\circ}C$ and 36, 168 hours at $4^{\circ}C$ were studied by scanning electron microscope. Muscle incubated with leukocyte lysosomal enzymes at pH 7.0 produced severe degradation of endomysial and sarcolemmal connective tissue and transverse ridges but at pH 4.0 endomysial and sarcolemmal structures remain moderately stable and tranverse ridges are very stable even after 24 hours incubation at $37^{\circ}C$ and 7 days incubation at $4^{\circ}C$.

  • PDF

Stereotactic Radiosurgery for Dural Arteriovenous Fistulas Involving the Transverse-Sigmoid Sinus : A Single Center Experience and Review of the Literatures

  • Baek, Hong-Gyu;Park, Seong-Hyun;Park, Ki-Su;Kang, Dong-Hun;Hwang, Jeong-Hyun;Hwang, Sung-Kyoo
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.458-466
    • /
    • 2019
  • Objective : We retrospectively assessed the efficacy of stereotactic radiosurgery (SRS) for dural arteriovenous fistulas (DAVFs) involving the transverse-sigmoid sinus and analyzed the angiographic and clinical results with our 8-year experience. Methods : Nine patients with intracranial DAVFs involving the transverse-sigmoid sinus underwent SRS using a Gamma $Knife^{(R)}$ (Elekta Inc., Atlanta, GA, USA) between 2009 and 2016. Five patients underwent SRS for residual DAVFs after embolization and four patients were treated with SRS alone. The median target volume was $1.9cm^3$ (range, 0.8-14.2) and the median radiation dose of the target was 17 Gy (range, 16-20). The median follow-up period was 37 months (range, 7-81). Results : Pulsating tinnitus (33%) was the most common symptom. DAVFs were completely obliterated in four patients (44%) and subtotally obliterated in five (56%). Six patients (67%) showed complete recovery of symptoms or signs, and three (33%) showed incomplete recovery. One patient experienced a recurrent seizure. Adverse radiation effects after SRS occurred in one patient (11%). The total obliteration rates after SRS were 16.7%, 37.5%, and 68.7% at 1, 2, and 3 years, respectively. The median interval from SRS to total obliteration of the fistula was 31 months (range, 12-38). The rates at which the symptoms started to improve were 40% at 1 month and 80% at 2 months after SRS. Symptoms started to improve at a median of 5 weeks after SRS (range, 3-21). Conclusion : SRS with or without embolization is a safe and effective treatment to relieve symptoms and obliterate DAVFs on the transverse-sigmoid sinus.

Ultrasonographic Estimation of Prostatic Size of Toy Breed Dogs (소형견의 전립선 크기에 관한 초음파적 연구)

  • 윤화중;최치봉;배춘식
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.168-172
    • /
    • 2000
  • Prostatic length and height on sagittal images and prostatic width and height on transverse images were measured ultrasonographically to establish upper limit of the prostate in 45 dogs which were clinically healthy and sexuallly intact. Linear 5regression and correlatin analysis were performed between prostatic parameters(length and height on sagittal images & width and height on transverse images) and parameters related to body size(body weight, left kidney length) and age of the dogs. Prostatic parameters were significantly correlated with body size and age of the dogs. Maximum predicted values with body weight and age for prostatic parameters were determined based o the upper limit of the 95% confidence interval of the mean predicted values. Such values should be useful for the small animal clinicians in determining if the prostate gland is too large for a given body weight and age, and may contribute to clinicl signs.

  • PDF

Transverse variability of flow and sediment transport in estuaries with an estuarine dam

  • Steven Figueroa;Minwoo Son
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.125-125
    • /
    • 2023
  • Estuarine dams are dams constructed in estuaries for reasons such as securing freshwater resources, controlling water levels, and hydroelectric power generation. These estuarine dams alter the flow of freshwater to the coastal ocean and the tidal properties of the estuaries which has implications for the estuaries' circulation and sediment transport. A previous study has analyzed the effect of estuarine dams on 1D (along-channel) circulation and sediment transport. However, the effect of estuarine dams on the transverse variability of along-channel and across-channel circulation and sediment transport has not been studied and is not known. In this study, a coupled hydrodynamic-sediment dynamic numerical model (COAWST) was used to analyze the transverse variability of along-channel and across-channel flow and sediment transport in estuaries with estuarine dams. The estuarine dam was found to change the 3D structure of circulation and sediment transport, and the result was found to depend on the estuarine type (i.e., strongly stratified (SS) or well-mixed (WM) estuary). The SS estuary had inflow in the channel and outflow over the shoals, consistent with estuarine circulation. Longer discharge interval reduced the estuarine circulation. The WM estuary had inflow over the shoals and outflow in the channel, consistent with tide-induced circulation. As the estuarine dam was located nearer to the estuary mouth, the tide-induced circulation was reduced and replaced with estuarine circulation. The lateral circualtion was the greatest in the tide-dominated estuaries. It was reduced and changed direction due to differential advection change as the dam was located nearer the mouth. Overall, the WM estuary transverse flow structure changed the most. Lateral sediment flux was important in all estuaries, particularly for transporting sediments to the tidal flats.

  • PDF