• Title/Summary/Keyword: transmission recovery

Search Result 380, Processing Time 0.022 seconds

An Effective Error-Concealment Approach for Video Data Transmission over Internet (인터넷상의 비디오 데이타 전송에 효과적인 오류 은닉 기법)

  • 김진옥
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.6
    • /
    • pp.736-745
    • /
    • 2002
  • In network delivery of compressed video, packets may be lost if the channel is unreliable like Internet. Such losses tend to of cur in burst like continuous bit-stream error. In this paper, we propose an effective error-concealment approach to which an error resilient video encoding approach is applied against burst errors and which reduces a complexity of error concealment at the decoder using data hiding. To improve the performance of error concealment, a temporal and spatial error resilient video encoding approach at encoder is developed to be robust against burst errors. For spatial area of error concealment, block shuffling scheme is introduced to isolate erroneous blocks caused by packet losses. For temporal area of error concealment, we embed parity bits in content data for motion vectors between intra frames or continuous inter frames and recovery loss packet with it at decoder after transmission While error concealment is performed on error blocks of video data at decoder, it is computationally costly to interpolate error video block using neighboring information. So, in this paper, a set of feature are extracted at the encoder and embedded imperceptibly into the original media. If some part of the media data is damaged during transmission, the embedded features can be extracted and used for recovery of lost data with bi-direction interpolation. The use of data hiding leads to reduced complexity at the decoder. Experimental results suggest that our approach can achieve a reasonable quality for packet loss up to 30% over a wide range of video materials.

A Study on the Automation of MVDC System-Linked Digital Substation (MVDC 시스템연계 디지털변전소 자동화 연구)

  • Jang, Soon Ho;Koo, Ja Ik;Mun, Cho Rong
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.10 no.7
    • /
    • pp.199-204
    • /
    • 2021
  • Digital substation refers to a substation that digitizes functions and communication methods of power facilities such as monitoring, measuring, control, protection, and operation based on IEC 61850, an international standard for the purpose of intelligent power grids. Based on the intelligent operating system, efficient monitoring and control of power facilities is possible, and automatic recovery function and remote control are possible in the event of an accident, enabling rapid power failure recovery. With the development of digital technology and the expansion of the introduction of eco-friendly renewable energy and electric vehicles, the spread of direct current distribution systems is expected to expand. MVDC is a system that utilizes direct current lines with voltage levels and transmission capacities between HVDCs applied to conventional transmission systems and LVDCs from consumers. Converting existing lines in substations, where most power equipment is alternating current centric, to direct current lines will reduce transmission losses and ensure greater current capacity. The process bus of a digital substation is a communication network consisting of communication equipment such as Ethernet switches that connect installed devices between bay level and process level. For MVDC linkage to existing digital substations, the process level was divided into two buses: AC and DC, and a system that can be comprehensively managed in conjunction with diagnostic IEDs as well as surveillance and control was proposed.

SR-ARQ Retramsission Persistence Management to Avoid TCP Spurious Timeout in a Wireless Environment (무선 환경에서 TCP 스퓨리어스 타임아웃 방지를 위한 SR-ARQ 재전송 지속성 관리 방안)

  • Kim, Beom-Joon;Han, Je-Chan
    • The KIPS Transactions:PartC
    • /
    • v.17C no.6
    • /
    • pp.451-458
    • /
    • 2010
  • To detect and recover packet losses over wireless links is very important in terms of reliability in packet transmission. Most wireless communication systems adopt an automatic repeat request (ARQ) protocol operating at link layer. However, it has been constantly addressed that the interaction not harmonized sufficiently between ARQ and TCP rather degrades TCP performance. In this paper, therefore, we propose an improved scheme from the aspect of the interaction with TCP loss recovery mechanism that can be applied to selective repeat ARQ (SR-ARQ) protocol and prove that the proposed scheme improves TCP performance significantly by OPNET simulations.

A Study on the Power System Application of High-Tc Superconducting Fault Current Limiter (고온초전도 한류기의 전력계통 적용에 관한 연구)

  • Bae, Hyeong-Thaek;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.115-116
    • /
    • 2006
  • Since the discovery of the high-temperature superconductors, many researches have been performed for the practical applications of superconductivity technologies in various fields. As results, significant progress has been achieved. Especially, Superconducting Fault Current Limiter (SFCL) offers an attractive means to limit fault current in power systems. The SFCLS, in contrast to current limiting reactors or high impedance transformers, are capable of limiting short circuit currents without adding considerable voltage drop and energy loss to power systems during normal operation. Under fault conditions, a resistance is automatically inserted into the power grid to limit the peak short-circuit current by transition from the superconducting state to the normal state, the quench. The advantages, like fail safe operation and quick recovery, make SFCL very attractive, especially for rapidly growing power systems with higher short-circuit capacities. In order to verify the effectiveness of the SFCL, in this paper, the analysis of fault current and voltage stability assessment in a sample distribution system and a transmission system are performed by the PSCAD/EMTDC based simulation method. Through the simulation, the advantage of SFCL application is shown, and the effective parameters of the SFCL are also recommended for both distribution and transmission systems. A resistive type component of SFCL is adopted in the analysis. The simulation results demonstrate not only the effectiveness of the proposed simulation scheme but also SFCL parameter assessment technique.

  • PDF

Efficient Energy and Position Aware Routing Protocol for Wireless Sensor Networks

  • Shivalingagowda, Chaya;Jayasree, P.V.Y;Sah, Dinesh.K.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.5
    • /
    • pp.1929-1950
    • /
    • 2020
  • Reliable and secure data transmission in the application environment assisted by the wireless sensor network is one of the major challenges. Problem like blind forwarding and data inaccessibility affect the efficiency of overall infrastructure performance. This paper proposes routing protocol for forwarding and error recovery during packet loss. The same is achieved by energy and hops distance-based formulation of the routing mechanism. The reachability of the intermediate node to the source node is the major factor that helps in improving the lifetime of the network. On the other hand, intelligent hop selection increases the reliability over continuous data transmission. The number of hop count is factor of hop weight and available energy of the node. The comparison over the previous state of the art using QualNet-7.4 network simulator shows the effectiveness of proposed work in terms of overall energy conservation of network and reliable data delivery. The simulation results also show the elimination of blind forwarding and data inaccessibility.

A Study on the Application of Under Voltage Load Shedding Scheme in Line Contingency considering Motor Load (모터부하를 고려한 상정사고 발생 시 저전압 부하차단 적용 방안에 대한 연구)

  • Lee, Yun-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.1
    • /
    • pp.21-26
    • /
    • 2017
  • Failure of high-voltage transmission line, which is responsible for large-scale power transmission, can be reason for system voltage instability. There are many methods to prevent voltage instability like adjustment of equipment, the generator voltage setting, and load shedding. Among them, the load shedding, have a problem of economic loss and cascading effect to power system. Therefore, the execution of load shedding, amount and timing is very important. Conventionally, the load shedding setting is decided by the preformed simulation. Now, it is possible to monitor the power system in real time by the appearance of PMU(Phasor Measurement Unit). By this reason, some of research is performed about decentralized load shedding. The characteristics of the load can impact to amount and timing of decentralized load shedding. Especially, it is necessary to consider the influence of the induction motor loads. This paper review recent topic about under voltage load shedding and compare with decentralized load shedding scheme with conventional load shedding scheme. And simulations show the effectiveness of proposed method in resolving the delayed voltage recovery in the Korean Power System.

An Embedded Timing Loss Detector for Robust Data Transmission (데이터 전송을 위한 타이밍 손실 검출기)

  • 이용환
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.9
    • /
    • pp.1404-1411
    • /
    • 1993
  • Unlike voice communication, data transmission, can be seriously affected by transient channel impairments. In some cases, timing synchronization between the transmitter and the receiver may not be recovered in the presence of these kinds of impairments without a forced reinitialization process. Therefore, it is highly desirable for data communication equipment to have an efficient timing loss detector for robust recovery. In this paper, one such detector is proposed for data transceivers haying a secondary channel embedded in the main channel. A known sequence multiplexed with the secondary channel data is repeatedly sent through the embedded secondary channel. For continuous watch-dog like operation, the detection is sequentially performed based on a modified up/down counter scheme. The performance of the proposed detector is analytically evaluated In closed form.

  • PDF

Wavelength Integration Transmission Method for Hybrid-PON (Hybrid-PON을 위한 파장통합 전송방식)

  • Kim, Jin-Hee;Cheong, Ki-Tae;Chung, Hae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.11B
    • /
    • pp.1207-1215
    • /
    • 2009
  • The FTTH is known as an optimal solution to provide broadband services like IPTV and the W-PON is a good alternative to implement the FTTH. It is firstly commercialized in Korea but not widely deployed because of it's high price. In this paper, we suggest a wavelength integration method to drop the price and enhance the utilization of the W-PON. The method makes one logical channel with multiple wavelengths when the W-PON system has to accommodate a signal of which transmission rate is greater than the rate of a single wavelength. Accordingly, the system can accommodate any signal rate. We introduce a frame structure, suggest synchronization and clock recovery methods, and finally show actual applications for the Ethernet and the G-PON.

Channel Error Detwction and Concealment Technqiues for the MPEG-2 Video Standard (MPEG-2 동영상 표준방식에 대한 채널 오차의 검출 및 은폐 기법)

  • 김종원;박종욱;이상욱
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.10
    • /
    • pp.2563-2578
    • /
    • 1996
  • In this paper, channel error characteristics are investigated to alleviate the channel error propagation problem of the digital TV transmission systems. First, error propagation problems, which are mainly caused by the inter-frame dependancy and variable length coding of the MPEG-2 baseline encoder, are intensively analyzed. Next, existing channel resilient schemes are systematically classified into two kinds of schemes; one for the encoder and the other for the decoder. By comparing the performance and implementation cost, the encoder side schemes, such as error localization, layered coding, error resilience bit stream generation techniques, are described in this paper. Also, in an effort to consider the parcticality of the real transmission situation, an efficient error detection scheme for a decoder system is proposed by employing a priori information of the bit stream syntas, checking the encoding conditions at the encoder stage, and exploiting the statistics of the image itself. Finally, subsequent error concealment technique based on the DCT coefficient recovery algorithm is adopted to evaluate the performance of the proposed error resilience technique. The computer simulation results show that the quality of the received image is significantly improved when the bit error rate is as high as 10$^{-5}$ .

  • PDF

ELECTRON MICROSCOPIC STUDY OF THE IRRADIATION EFFECT ON THE RAT MANDIBULAR CONDYLE (방사선조사가 하악과두에 미치는 영향에 관한 전자현미경적 연구)

  • Park Myoung Seon;Park Tae Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.26 no.2
    • /
    • pp.45-63
    • /
    • 1996
  • In attempt to determine radiation effect on the mandibular condyle of the growing rat, 27 white female rats (Sprague-Dawley) were divided into 3 groups and irradiated respectively 5Gy, 10Gy, 20Gy using MK Cell Irradiator. Mandibular condyles from rats on the day of 1, 7, 14 after the irradiation day were obtained, sectioned sagittally and examined by light microscopy, and thereafter middle portion through anteroposterior direction on the sagittal plane was selected to examine the ultrastructural change by transmission electron microscopy. The obtained results are followings. 1. In the proliferative zone some cells showed little organelles in case of 5Gy irradiation, in addition the number of degenerative cells increased and in case of 10Gy irradiation, and in case of 20 Gy irradiation total number of cells decreased. 2. In the hypertrophic zone, narrowing of width and partial disorder in hypertrophic process were noted in case of 5 Gy irradiation, and more prominent narrowing of width and more irregular disorder in hypertrophic process in case of both 10Gy and 20Gy irradiation. 3. In the upper hypertrophic zone some chondrocytes seemed to be dying and the polarity of nuclei could not be seen, if any. 4. The periodic observation showed the severest change at day 7 and the signs of recovery at day 14 after irradiation.

  • PDF