• 제목/요약/키워드: transmission power

검색결과 5,792건 처리시간 0.038초

Optical Power Transfer of Grating - Assisted Directional Coupler with Three - Guiding Channels : TM modes Case

  • Ho, Kwang-Chun;Ho, Kwang-Soo
    • Journal of the Optical Society of Korea
    • /
    • 제8권4호
    • /
    • pp.149-155
    • /
    • 2004
  • Newly developed modal transmission-line theory(MTLT) is used to analyze rigorously the optical power distribution in grating-assisted directional couplers(GADCs) with three guiding channels. By defining a novel coupling efficiency ${\eta}$ amenable to the rigorous analytical solutions of modal transmission-line theory, we explicitly evaluate the power coupling and distribution of TM modes. The results reveal that the incident power is sensitively partitioned through three output channels in terms of such grating parameters as the grating period, the duty cycle, and the operating wavelength.

송전 전력 제어를 위한 분산 정지형 직렬 보상기에 관한 연구 (Distributed static series compensator based flexible AC transmission system)

  • 윤한종;조영훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 추계학술대회 논문집
    • /
    • pp.29-30
    • /
    • 2016
  • This paper describes a distributed static series compensator (DSSC) which is a type of distributed flexible ac transmission system (DFACTS). The control principles including the power flow control and the current regulation are explained in detail. In order to verify the effectiveness of the DSSC, the simulation results are offered.

  • PDF

POWER AWARE ROUTING OPTIMIZATION: AN ENHANCEMENT

  • Nguyen, VanDong;Song, Joo-Seok
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2004년도 춘계학술발표대회
    • /
    • pp.1453-1456
    • /
    • 2004
  • PARO, a power-aware routing optimization mechanism, is proposed in [1] to minimize the transmission power needed to forward packets between wireless devices in ad hoc network. The mechanism works by redirecting the route to pass through one or more intermediate nodes on behalf on source-destination pairs, then reducing the end-to-end transmission power. This paper will show an extension of this model and provide an analysis of the geometrical area lying between source and destination in which the intermediate node elects to perform redirection. The duration the intermediate node stays in that area is also computed.

  • PDF

송변전 지리정보 시스템을 이용한 고압 송전선과 거주지 간 이격거리에 대한 인식 평가 (Evaluating the Perception of Distance to High-Voltage Power Lines from Home Using Transmission and Substation Geographic Information System)

  • 옥민수;이무송;전보민;김화정;류현미;명성호;민석원
    • 한국전자파학회논문지
    • /
    • 제26권7호
    • /
    • pp.646-655
    • /
    • 2015
  • 이번 연구에서는 송변전 지리정보 시스템(Transmission and substation Geographic Information System: TGIS)을 이용하여 일반인들이 판단한 고압 송전탑 및 송전선, 변전소와 거주지 간 거리 인식이 실측 거리와 일치하는지 확인해 보았다. 총 725명의 응답자 중 136명이 고압 송전탑 및 송전선, 변전소가 눈에 보이는 거리에 있다고 응답하였고, 이 중 114명이 TGIS로 분석할 수 있는 유효한 주소를 제공하였다. 114명 중 42명(36.8 %)은 실측 거리보다 인식 거리가 짧았으며, 15명(13.2 %)은 인식 거리보다 실측 거리가 짧았다. 일반인들의 고압 송전탑 및 송전선, 변전소와 거주지 간 거리 예측의 타당도가 높지 않은 점을 바탕으로 했을 때, 이를 극저주파 전자기장 노출량의 대용물로 사용하는 것은 부적절할 것으로 보인다.

상용차 변속기 내부 기어 경량화에 따른 연비 저감 효과에 대한 연구 (Fuel Consumption Effect by Mass Reduction of Low Speed Transmission Gears in Commercial Vehicles)

  • 한성길;신유인;정종규;송철기
    • 동력기계공학회지
    • /
    • 제20권5호
    • /
    • pp.60-65
    • /
    • 2016
  • Dynamic performance of transmission has a substantial effect on dynamic performance and fuel efficiency of a vehicles. Dynamic performance of transmission and mass moments of inertia of transmission gears are related directly each other. Then a smaller amount of kinetic energy from vehicles that repeat acceleration and deceleration requires lighter rotating part in transmission. It is going to increases fuel efficiency as a result. In this study, equivalent inertia moments of inertia at different speeds were calculated by simplifying the transmission system. To find out lightening effect at low speed level gear on fuel efficiency, the powerflow of transmission was analyzed. And the lightning effect of the rotating parts in transmission is compared with the mass reduction of sprung parts in vehicle.

8단 자동변속기의 유성기어 가공을 위한 동력 흐름 해석 (I) : 1-3단 (Power Flow Analysis for Manufacturing of Planetary Gears in a 8-Speed Automatic Transmission (I): 1-3 Speeds)

  • 이경진;김정민
    • 한국기계가공학회지
    • /
    • 제15권5호
    • /
    • pp.48-56
    • /
    • 2016
  • In this paper, we analyze the power flow of an eight-speed automatic transmission by using a lever analogy for the manufacturing of planetary gears. The results indicate that the engine power is passed down to the carrier and ring gear in the first double pinion planetary gear (DPPG1), and to the sun gear, carrier, and ring gear in DPPG3 for the first speed. Although the power flow is similar in the second speed, the power circulation occurs in the second single pinion planetary gear (SPPG2). For the third speed, the engine power is passed from the carrier to the ring gear in DPPG, at which point the power is split between the sun gears of SPPG2 and DPPG3.

A Fully Integrated 5-GHz CMOS Power Amplifier for IEEE 802.11a WLAN Applications

  • Baek, Sang-Hyun;Park, Chang-Kun;Hong, Song-Cheol
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제7권2호
    • /
    • pp.98-101
    • /
    • 2007
  • A fully integrated 5-GHz CMOS power amplifier for IEEE 802.11a WLAN applications is implemented using $0.18-{\mu}m$ CMOS technology. An on-chip transmission-line transformer is used for output matching network and voltage combining. Input balun, inter-stage matching components, output transmission line transformer and RF chokes are fully integrated in the designed amplifier so that no external components are required. The power amplifier occupies a total area of $1.7mm{\times}1.2mm$. At a 3.3-V supply voltage, the amplifier exhibits a 22.6-dBm output 1-dB compression point, 23.8-dBm saturated output power, 25-dB power gain. The measured power added efficiency (PAE) is 20.1 % at max. peak, 18.8% at P1dB. When 54 Mbps/64 QAM OFDM signal is applied, the PA delivers 12dBm of average power at the EVM of -25dB.

345KV 송전선의 과도안정도계산 I (A study on transient stability of 345 KV power transmission line)

  • 이재숙
    • 전기의세계
    • /
    • 제18권1호
    • /
    • pp.24-29
    • /
    • 1969
  • This is preliminary study concerning the future construction and operation of 345KV power transmission line in Korea which will be added to the existing 161KV power system by the end of 1970 in order to increase the power carrying capacity between Seoul and Pusan area; 350 kilo meters aparts, in accordance with the ambitious second five years power development schedule of Korea Electric Company. The result of this study says that an intermidiate switching station should be installed at the middle position of the line to improve the transient stability of the system, considerable amount of capacitors or synchronous condenser are to be installed to reduce the voltage drop at receving end of line during the heavy load hours, and also in some measure to avoid the voltage rise by self-excitation of power generators during the light load hours and while energizing the line. This is the first attempt to realize the EHV power transmission line in Korea so that the additional study is necessary on the kind and size of conductors, the necessary number of insulators and the suitable clearance distances between conductor and steel tower or earth from the technical and economical view points. These are necessary steps to be taken by the writer before getting into the calculation on the transient stablity of the power system.

  • PDF

A Novel Non-contact Measurement Method for the Detection of Current Flowing Through Concealed Conductors

  • Yang, Fan;Liu, Kai;Zhu, Liwei;Hu, Jiayuan;Wang, Xiaoyu;Shen, Xiaoming;Luo, Hanwu;Ammad, Jadoon
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.43-48
    • /
    • 2017
  • In order to detect the current flowing through concealed conductor, this paper proposes a new method based on derivative method. Firstly, this paper analyzes the main peak characteristic of the derivative function of magnetic field generated by a current-carrying conductor, and a relationship between the current flowing through the conductor and the main peak of the derivative function is obtained and applied to calculate the current. Then, the method is applied to detect the conductor current flowing through grounding grids of substations. Finally, the numerical experimental and field experiment verified the feasibility and accuracy of the method, and the computing results show that the method can effectively measure the conductor current of grounding grids with low error, and the error is within 5 %.