• 제목/요약/키워드: transmission power

검색결과 5,780건 처리시간 0.028초

부하 특성을 고려한 TCSC 전력송전 시스템의 고조파 해석 (Harmonic Analysis of TCSC Power Transmission System considering Load Characteristics)

  • 정교범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.468-471
    • /
    • 2000
  • This paper investigates the harmonics of TCSC power transmission system having nonlinear VI characteristic loads. Nonlinear VI characteristic components are modelled with Nortons harmonic current sources. The system parameters such as line impedances admittances and node voltages and the thyristor switching action are described in complex Fourier series. EMTP simulation studies with a detailed three-phase TCSC power transmission system are also performed in order to verify the harmonic analysis at the steady state.

  • PDF

혼잡에 의한 시장지배력 산정 방안 (Estimation of Local Market Power under Transmission Congestion)

  • 이동진;신영균;정구형;김발호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.494-496
    • /
    • 2003
  • Transmission congestion is one of the key factors to local market power in competitive electricity markets. This paper presents an alternative methodology in estimating market power under transmission congestion. The proposed methodology was demonstrated with the Optimal Power Flow(OPF).

  • PDF

Mid-Span Spectral Inversion 기법을 채택한 장거리 광 전송 시스템에서의 증폭기 간격에 따른 비트 에러율 (Bit Error Rate Dependence on Amplifier Spacing in Long-Haul Optical Transmission System with Mid-Span Spectral Inversion)

  • 이성렬
    • 한국항행학회논문지
    • /
    • 제9권2호
    • /
    • pp.109-120
    • /
    • 2005
  • 본 논문에서는 MSSI 보상 기법을 채택한 1,200 km의 WDM 전송 시스템에서의 비트 에러율, 수신 감도, 입사 전력 최소 허용치를 증폭기 간격에 따라 수치적으로 살펴보았다. 변조 파형 형식에 관계없이 수신 감도와 입사 전력 최소 허용치 모두 증폭기 간격이 증가할수록 나빠지는 것을 알 수 있었다. 수신 감도 측면에서는 NRZ 전송보다 RZ 전송을 하는 경우 감도를 개선할 수 있었지만 실제 입사 전력 허용치 면에서는 NRZ가 RZ 전송보다 유리한 것을 확인하였다. 아울러 증폭기 간격을 50 km 이하로 해야만 수신 감도와 입사 전력 최소 허용치 모두 분산 계수, 채널 파장, 펌프광 전력에 비교적 영향을 적게 받는 것을 확인할 수 있었다.

  • PDF

2-모드 기계유압식 무단변속기의 성능 및 전달효율해석 (Performance and Transmission Efficiency Analysis of 2-Mode Hydro Mechanical Transmission)

  • 정규홍;김형의;김종기
    • 한국자동차공학회논문집
    • /
    • 제13권1호
    • /
    • pp.90-98
    • /
    • 2005
  • HMT is a type of continuously variable transmission which has split power flow path characteristics with gear train and hydro static unit. The benefit of improved fuel economy and high power capacity enables it to be a promising application fur large vehicles. This paper presents the analysis results including velocity, static torque, transmission efficiency and dynamic model of the HMT that is developed for city buses. The speeds or gear shafts, the static clutch torque and split power ratio for each mode are detailed here. From the analysis of HMT transmission efficiency considering the power loss in meshed gear and hydraulic unit, we can conclude that minimization of hydraulic power is necessary for improved fuel economy design. Also, the dynamic simulation result for mode shift characteristics shows that little shift shock is observed because of the synchronized rotation speed in clutch.

멀티케이블을 이용한 초전도 전력케이블의 구성에 관한 연구 (A Study on the Composition of Superconducting Power Cable Using the Multi-cable)

  • 최석진;이상진;심기덕;조전욱;이수길;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권1호
    • /
    • pp.42-46
    • /
    • 2010
  • The HTS power cable is composed of 2 layers for transmission and 1 layer for shield. The superconducting tapes of transmission layers and shield layer are wound in a cylindrical shape with a winding pitch. The radius of cylinder and the number of superconducting tapes are decided considering to the transmission current capacity and the critical current of superconducting tapes. The increasement of transmission current capacity will increase in volume of HTS cable system. In this paper, the composition method of supercondcuting power cable using the multi-cable is presented. The coated conductor tape can be wound on the smaller cylinder because it has the smaller critical bending diameter than the BSCCO tape. A small-scale cable was composed using the coated conductor tapes and a multi-cable is composed using a small-scale cable considering to transmission current capacity. Even increase of transmission current capacity, this method has advantage that the HTS superconducting power cable can be composed easily. The 22.9 kV and 154 kV superconducting power cable was composed using the presented method.

전압플리커 저감과 역률 보상 기능을 갖는 배전용 STATCOM의 실계통연계 운전결과 분석 (Analysis of the Distribution STATCOM for Improving the power factor and Mitigation of Voltage Flicker in Real System)

  • 오관일;전영수;박상태;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.245-248
    • /
    • 2000
  • This paper presents the test and operation results of the domestic demonstration of the reactive power compensation device called STATCOM (STATic COMpensator). The object of the paper is to describe the reliability of the unit based on the extensive operation databases. By controlling reactive power, the technology offers utilities the opportunity for increased efficiency and their capabilities will permit transmission planners make the best use of their existing transmission resources STATCOM is a custom power device in a way and can be used in a similar way for the dynamic compensation of power transmission systems, mitigation of voltage flicker and improving the power factor. It is shown that the STATCOM has clear advantages in areas such as: mitigation of voltage flicker and improving power factor.

  • PDF

고온초전도 전력케이블 적용효과 검토 (A Study on the Application Effects of HTS Power Cable)

  • 성기철;조전욱;김해종;권영길;최상봉;류강식;김봉태;유인근
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권2호
    • /
    • pp.32-36
    • /
    • 2000
  • In this study, we performed the long-term expansion planning for the conceptual design of HTS power cable in Seoul area. In Korea, underground power cable has been required gradually with increasing demand of electric power transmission density and low loss characteristics in the comparison with a conventional power cables, so we assumed that the HTS power cable is applied between the downtown area and the outskirts of the city for the large power transmission capacity. This paper is to show the effects of HTS power cables in Seoul based on the power system analysis.

  • PDF

Wireless Energy Transmission High-Efficiency DC-AC Converter Using High-Gain High-Efficiency Two-Stage Class-E Power Amplifier

  • Choi, Jae-Won;Seo, Chul-Hun
    • Journal of electromagnetic engineering and science
    • /
    • 제11권3호
    • /
    • pp.161-165
    • /
    • 2011
  • In this paper, a high-efficiency DC-AC converter is used for wireless energy transmission. The DC-AC convertter is implemented by combining the oscillator and power amplifier. Given that the conversion efficiency of a DC-AC converter is strongly affected by the efficiency of the power amplifier, a high-efficiency power amplifier is implemented using a class-E amplifier structure. Also, because of the low output power of the oscillator connected to the input stage of the power amplifier, a high-gain two-stage power amplifier using a drive amplifier is used to realize a high-output power DC-AC converter. The high-efficiency DC-AC converter is realized by connecting the oscillator to the input stage of the high-gain high-efficiency two-stage class-E power amplifier. The output power and the conversion efficiency of the DC-AC converter are 40.83 dBm and 87.32 %, respectively, at an operation frequency of 13.56 MHz.

풍하중을 받는 송전철탑의 정적, 동적 및 좌굴해석 (Static, Dynamic and Buckling Analyses of a Power Transmission Tower under Wind Load)

  • 정형조;신동승;문병욱;박지훈;이성경;민경원
    • 한국전산구조공학회논문집
    • /
    • 제19권4호
    • /
    • pp.369-374
    • /
    • 2006
  • 가섭선 및 애자가 연결되어 있는 복잡한 구조물인 송전철탑의 3차원 모델링을 통하여 동특성을 파악하고, 풍하중에 대한 응답 특성을 정적, 동적 및 좌굴 해석을 가섭선의 절단 유무에 따라 분석하였다. 우선, 고유치해석을 통해, 송전철탑이라는 구조시스템이 일반 건축물과는 달리 극소수의 저차 모드가 구조물의 동적 거동을 좌우하지 않고, 상대적으로 많은 모드들이 동적 거동에 기여한다는 것을 확인하였다. 두 번째로, 정적 해석과 좌굴 해석을 통해, 대상 구조물이 정적인 개념의 풍하중에 대해서 구조적으로 안전하고 좌굴에 대해서도 충분한 안전율을 확보하고 있음을 확인하였다 그러나, 모든 가섭선이 단절되는 극단적인 경우에는 안전율이 상당히 낮아졌으며 이러한 경우에 구조물의 붕괴 및 전도를 방지할 대책에 대한 검토가 필요하다고 사료된다 마지막으로, 풍하중의 시간에 따른 변화를 고려한 동적해석을 통해, 풍하중의 동적 변동성분이 구조물의 응답을 증가시키고 있음을 확인하였다.

Economic analysis of a 22.9 kV HTS power cable and conventional AC power cable for an offshore wind farm connections

  • Jung, Ga-Eun;Dinh, Minh-Chau;Sung, Hae-Jin;Park, Minwon;Yu, In-Keun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권4호
    • /
    • pp.60-64
    • /
    • 2018
  • As the offshore wind farms increase, interest in the efficient power system configuration of submarine cables is increasing. Currently, transmission system of the offshore wind farm uses almost AC system. High temperature superconducting (HTS) power cable of the high capacity has long been considered as an enabling technology for power transmission. The HTS cable is a feasible way to increase the transmission capacity of electric power and to provide a substantial reduction in transmission losses and a resultant effect of low CO2 emission. The HTS cable reduces its size and laying sectional area in comparison with a conventional XLPE or OF cable. This is an advantage to reduce its construction cost. In this paper, we discuss the economic feasibility of the 22.9 kV HTS power cable and the conventional AC power cables for an offshore wind farm connections. The 22.9 kV HTS power cable cost for the offshore wind farm connections was calculated based on the capital expenditure and operating expense. The economic feasibility of the HTS power cable and the AC power cables were compared for the offshore wind farm connections. In the case of the offshore wind farm with a capacity of 100 MW and a distance of 3 km to the coast, cost of the 22.9 kV HTS power cable for the offshore wind farm connections was higher than 22.9 kV AC power cable and lower than 70 kV AC power transmission cable.