• 제목/요약/키워드: transmission power

검색결과 5,780건 처리시간 0.029초

송전선로에서 발생하는 전자계 제약을 고려한 발전력의 최적 재분배 (An Optimal Rescheduling of Power Generation to Constrain the EM Field Emitted from Power Transmission Lines)

  • 김종형;신명철;라완수;박일한
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권10호
    • /
    • pp.464-471
    • /
    • 2001
  • Power utilities must satisfy both supplying high quality power economically and reducing EMF levels. In general, in order to reduce EMF levels from transmission line, it is effective to install shielding wires, configure wires with minimal space or modify structure of other conductors, etc., but these techniques require much cost and time. To some extent, the EMF levels associated with critical transmission lines can be reduced by redistributing the scheduled power generation, since it can change the power flows. There this technique can be readily applied without modifying other structures. This paper considers the OPF(Optimal Power Flow) with the EMF constraints in transmission lines to determine the power generation redistributions and demonstrates numerically the effectiveness of the approach.

  • PDF

3상 대용량 무선 전력 전송 시스템 (Three-phase high power wireless transmission system)

  • 오정식;이명진;차승태;김주용;이광운;박태식
    • 전기전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.195-201
    • /
    • 2017
  • 대용량 무선 전력 전송 시스템은 ESS, 배터리 장치 등의 발전을 위한 핵심 기술이다. 무선 전력 전송 장치는 현재 자기유도 및 자기공진 기술들이 주를 이루고 있으며 유선 전력 전송에 비해 전력 전송 용량이 낮고 효율이 낮은 단점이 있다. 이 논문에서는 자기 결합을 갖는 가변속 모터 시스템을 기반으로 하는 대용량 무선 전력 전송 시스템을 제안하고자 한다. 제안된 방식은 대용량 전력 전송이 가능하며, 고효율과 낮은 고장 가능성의 장점을 가지고 있으며 시뮬레이션과 실험을 통해 제안된 기법의 성능을 검증하였다.

오차를 고려한 송전선 보호 거리계전 정정룰에 대한 고찰 (Examination with Transmission Line Distance Relay Setting Rule Considering Error)

  • 조성진;최면송;현승호;김종욱;이주왕;조범섭;유영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.12-15
    • /
    • 2002
  • Korea Power System Protection Setting Rule was used from the rectify 1990's. Thereafter transmission voltage is raised the voltage into 765kV, and introduction to new technology of Power System, and was many of variation but, it is using. The present is using Digital type distance relay for 765kV transmission line protection. If impedance value of transmission line were to value lower than setting, this would be operating and relay setting rule is for 85% into Zone 1 self section, and Zone 2 is a 125%, Zone 3 is a 225%. Which's $15{\sim}25%$ include current transformer error 5%, potential transformer 5%, relay calculation error 5% and margin factor from the field experience. This paper is discussed transmission protective relay and relay setting rule of high voltage power system and we verify the correctness relay setting rule with distance relay using Matlab simulation.

  • PDF

Ad Hoc네트워크의 Cross-Layer설계를 위한 Opportunistic Scheduling과 Power Control기법 (Opportunistic Scheduling and Power Control for Cross-Layer Design of Ad Hoc Networks)

  • 레이젤 카사끼테;함병운;황원주
    • 한국통신학회논문지
    • /
    • 제31권9A호
    • /
    • pp.856-867
    • /
    • 2006
  • This paper proposes a new algorithm for opportunistic scheduling that take advantage of both multiuser diversity and power control. Motivated by the multicast RTS and priority-based CTS mechanism of OSMA protocol, we propose an opportunistic packet scheduling with power control scheme based on IEEE 802.11 MAC protocol. The scheduling scheme chooses the best candidate receiver for transmission by considering the SINR at the nodes. This mechanism ensures that the transmission would be successful. The power control algorithm on the other hand, helps reduce interference between links and could maximize spatial reuse of the bandwidth. We then formulate a convex optimization problem for minimizing power consumption and maximizing net utility of the system. We showed that if a transmission power vector satisfying the maximum transmission power and SINR constraints of all nodes exist, then there exists an optimal solution that minimizes overall transmission power and maximizes utility of the system.

Establishing Best Power Transmission Path using Receiver Based on the Received Signal Strength

  • 엄정숙;손희동;박용완
    • 인터넷정보학회논문지
    • /
    • 제18권6호
    • /
    • pp.15-23
    • /
    • 2017
  • Wireless power transmission (WPT) for wireless charging is currently attracting much attention as a promising approach to miniaturize batteries and increase the maximum total range of an electric vehicle. The main advantage of the laser power beam (LPB) approach is its high power transmission efficiency (PTE) over long distance. In this paper, we present the design of a laser power beam based WPT system, which has a best WPT channel selection technique at the receiver end when multiple power transmitters and single power receiver are operated simultaneously. The transmitters send their transmission channel information via optically modulated laser pulses. The receiver uses the received signal strength indicator and digitized data to choose an optimum power transmission path. We modeled a vertical multi-junction photovoltaic cell array, and conducted an experiment and simulation to test the feasibility of this system. From the experimental result, the standard deviation between the mathematical model and the measured values of normalized energy distribution is 0.0052. The error between the mathematical model and measured values are acceptable, thus the validity of the model is verified.

정유압 기계식 변속장치의 동력전달특성 (Power Transmission Characteristics of a Hydro-Mechanical Transmission)

  • 성덕환;김형의;이근호;김현수
    • 대한기계학회논문집A
    • /
    • 제25권11호
    • /
    • pp.1854-1862
    • /
    • 2001
  • In this paper, power flow characteristics of a hydromechanical transmission(HMT) are investigated using network analysis. The HMT used in this study consist of a hydrostatic unit(HSU), planetary gear sets, clutches and brakes providing forward 4 speeds and backward 2 speeds. Since the HMT power flows showing a closed loop and the HSU efficiency varies depending on the pressure and speed, a systematic approach is required to analyze the power transmission characteristics of the HMT. In order to analyze the closed loop power flow and the HSU power loss which changes depending on the pressure and speed, network model is constructed fur each speed range. In addition, an algorithm is proposed to calculate an accurate HSU loss corresponding to the experimental results. It is found from the network analysis that the torque and speed of each transmission element including the HSU can be obtained as well as direction of the power flow by the proposed algorithm. It is expected that the network analysis can be used in the design of relatively complicated transmission system such as HMT.

그린 컴퓨팅을 위한 무선 네트워크 전송 파워 조절에서 고출력 전송의 성능 불공평성에 대한 연구 (Study on The Throughput Unfairness of High-power transmission in The Transmission Power Controlled Wireless Networks Considering Green Computing)

  • 이희진;김종권
    • 대한전자공학회논문지TC
    • /
    • 제47권10호
    • /
    • pp.27-35
    • /
    • 2010
  • 무선 패킷 망에서 무선 자원과 무선 단말의 전력을 얼마나 효율적으로 사용할 수 있는가 하는 것은 무선 패킷 망 보급을 위한 기본 해결 과제이다. 이에 단말의 전력 소모를 줄이면서 무선 망 용량 (capacity)을 증가시키는 기법으로 전송 파워 조절 기법이 주목받고 있다. 무선 패킷 망에 전송 파워 조절 기법을 적용할 때 전송 파워의 세기에 따라 공평한 전송성능을 보장하지 못하고 기아상태에 이르는 전송 불공평성 문제가 지금까지 깊이 연구되지 않고 있다. 이에 본 연구에서는 전송 파워의 세기에 따른 성능 불공평성을 경쟁자 수의 차이에 의한 불공평한 매체 접근 기회에 있음을 분석을 통해 보이고 불공평성을 해결하기 위한 간단한 물리-맥 (PHY-MAC) 계층 간 접근법을 제안한다.

정유압기계식 변속장치의 동력특성해석 (Power Characteristics Analysis of Hydro-Mechanical Transmission)

  • 성덕환;이근호;김현수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.519-524
    • /
    • 2001
  • In this paper, power flow characteristics of a hydromechanical transmission(HMT) are investigated using network analysis. The HMT used in this study consist of a hydrostatic unit(HSU), planetary gear sets, clutches and brakes providing forward 4 speeds and backward 2 speeds. Since the HMT power flows showing a closed loop and the HSU efficiency varies depending on the pressure and speed, a systematic approach is required to analyze the power transmission characteristics of the HMT. In order to analyze the closed loop power flow and the HSU power loss which changes depending on the pressure and speed, network model is constructed for each speed range. In addition, an algorithm is proposed to calculate an accurate HSU loss corresponding to the experimental results. It is found from the network analysis that the torque and speed of each transmission element including the HSU can be obtained as well as direction of the power flow by the proposed algorithm. It is expected that the network analysis can be used in the design of relatively complicated transmission system such as HMT.

  • PDF

송전망 이용요금 산정을 위한 교육용 시뮬레이터 개발 (A Windows-based Software for Education and Training of Transmission Network Charge)

  • 김현홍;조기선;정윤원;박종배;신중린
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1373-1381
    • /
    • 2007
  • This paper presents a graphical windows-based software for the education and training of transmission network charge. The motivation for the development of the simulator is to provide students with a simple and useable tool for gaining an intuitive feel for transmission network charge. The developed simulator consists of the main module (MMI, GUI), the power flow module (PF), the power flow tracing module (PFT), and usage cost DB module (UCD). Each module has a separate graphical and interactive interfacing window. The developed simulator provides with two power system analysis methods (i.e., DC-PF and Modified DC-PF) and supports the PSS/E input data format to load input data of power system. Also, power flow tracing can be calculate using four methods such as "Felix Wu", "Modified Felix Wu", "DCLF ICRP", and "Reverse MW mile". Results of calculation for transmission usage cost are displayed and compared on the window through the table and/or chart. Therefore, the developed simulator can be utilize as a useful tool for effective education and training of transmission network charge.

345kV 인천화력 송전선로 철탑도괴 원인분석 및 대책 (345kV Overhead Transmission Line Collapse Analysis and Countermeasures)

  • 박재웅;신태우;최진성;최한열;민병욱
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.531-535
    • /
    • 2010
  • 345kV Incheon Thermal Power Plant Transmission Line Collapse Analysis and Countermeasures. The Typhoon Galmaegi which had been formed in July 15, 2008 diminished into a tropical cyclone and cooled the air above the West Sea. The cooled air colliding with the warm inland air caused a strong whirlwind at some places in the west seaside; the whirlwind battered the 345kV Incheon Thermal Power Plant Transmission Line to be collapsed. The resistance of transmission towers against wind pressure, one of the key elements in transmission line engineering, is designed to endure the pressure corresponding to the maximum instantaneous wind speed. Before the above accident happened, no transmission line has ever been collapsed by a whirlwind. So this paper is aimed to analyze causes that collapsed 345kV Incheon Thermal Power Plant transmission line and to introduce countermeasures.