• Title/Summary/Keyword: transmission power

Search Result 5,780, Processing Time 0.054 seconds

Calculation of Reclosing Dead Time of 500 kV Horizontal Single Circuit Transmission Line (500 kV 수평배열 1회선 송전선로의 재폐로 무전압시간 산정)

  • Shim, E.B.;Kwak, J.S.;Joo, H.J.;Park, H.S.;Kang, Y.W.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.641-643
    • /
    • 2005
  • It is usual to operate the long transmission line with transposition of each phase in order to avoid voltage unbalance due to unbalanced capacitances at each phase of the line end. This paper described the Ferranti voltage rise of line end, charging current and secondary arc current according to the transposition of line or not. The positive and negative sequence current was derived by the phase current, and then the unbalanced rate was calculated. Then, we obtained the reclosing dead time of the single phase reclosing scheme for 500 kV single circuit horizontal arrangement transmission line system.

  • PDF

A Study on the Performance of Continuously Variable Transmission composed of V-belt Drive and 2K-H type Differential Gear Unit (2K-H형 차동기어장치와 V-belt를 결합한 무단변속기의 성능에 관한 연구)

  • 박재민;김연수;최상훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.739-742
    • /
    • 1997
  • Continuously variable transmission(CVT) mechanisms are proposed, which can offer a backward mode, a geared neutral, an underdrive mode and an overdriver mode. They are not required of a starting device as a torque converter. CVT mechanisms developed here present two distinct operating modes which are a power circulation mode and a power split mode. The transition of two modes takes place at the particular CVU speed ratio. For these CVT mechanisms, performance analysis related to speed ratio, power ratio and theoretical efficiency are executed.

  • PDF

Performance comparison of the RF-DC converter circuit for wireless power transmission (무선전력전송을 위한 RF-DC 변환기 회로의 성능비교)

  • Choi, Ki-Ju;Hwang, Hee-Yong
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.145-149
    • /
    • 2009
  • A RF-DC converter is one of the most important components for a wireless power transmission. It has been developed for many applications such as space solar power system, and Radio Frequency Identification(RFID). In this paper, we designed three types of RF-DC converter and compare the performance of each. All types RF-DC convertoer have a maximum conversion efficiency at input power level of 0 dBm~5 dBm and RF-DC converter of third type was the best performance that has a 21.9% of conversion efficiency.

  • PDF

An Investigation of Characteristics of the Operating Modes of Two-Module Thyristor Controlled Series Compensator

  • Chung, Gyo-Bum
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.903-908
    • /
    • 1998
  • This paper aims at investigating the characteristics of the operating modes of two-module Thyristor Controlled Series Compensator (TCSC) in a power transmission system. The operating modes of two-module TCSC are defined, analyzed and compared to those of single-module TCSC are defined, analyzed and compared to those of single-module TCSC. The load flow program, the stability calculation program and Electro Magnetic Transient Program (EMTP) simulation of a TCSC power transmission system are developed for the performance evaluation of two-module TCSC as a power flow controller. In the process of the simulation study, the potential problem areas of the TCSC power transmission system are identified.

  • PDF

Overvoltage Analysis and Air Clearance Design of 345kV/154kV Transmission Tower (345kV/154kV 계통 과전압 해석과 공기절연간격 산정)

  • Shim, E.B.;Woo, J.W.;Kwak, J.S.;Yoon, S.H.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.449-451
    • /
    • 2001
  • This paper described the switching overvoltage analysis on the 345kV and 154kV transmission system by EMTP(Electromagnetic transient Program) for the enactment of current insulation design standards of KEPCO. The air clearance design of current transmission tower was reviewed and revised by the calculated result, considering swing angle for the each type of insulator string by the wind velocity.

  • PDF

An analysis of the measured electric and magnetic fields of transmission lines in Korea (전국의 송전선로 전자계 측정치와 계산치와의 비교 분석)

  • Kim, S.B.;Cho, S.B.;Shin, K.Y.;Lee, D.I.;Kim, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2368-2370
    • /
    • 1999
  • A nationwide survey for electric and magnetic fields(EMFs) near overhead transmission lines has been conducted. The median values of the electric and magnetic fields of 208 transmission lines were 0.50 kV/m and 12.6 mG, respectively. The maximum values were 3.16 kV/m and 125 mG. The measured EMFs were compared with the calculated ones. The causes of the discrepancy between measured and calculated EMFs are also discussed.

  • PDF

Dynamic Coverage Control to Improve Channel Utilization in IEEE 802.11 (IEEE 802.11에서 채널 이용율을 높이기 위한 동적 커버영역 제어)

  • 양덕용;이태진
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.195-199
    • /
    • 2003
  • BEE 802.11 Wireless LAN protocol uses fixed transmission power. It does not consider a power control mechanism based on the distance between the transmitter and the receiver in order to improve overall channel utilization. In home environment, where stations generally lie around an AP, the AP is subject to use transmission power more than it needs. And wireless LAN stations may require different minimal desired received power. If there are many adjacent BSSs in densely populated WLAN area, they might cause RF interference to one another. In this paper we focus on the improvement of aggregate utilization by mitigating RF interference among BSSs. We show that RF interference by APs can be reduced by controlling transmission power using Link Margin information. The reduced interference will then lead to the increased aggregate throughput which is efficient resource utilization.

  • PDF

Development of An Expert System to Decide the Resetting Area of Protective Distance Relay in Power Transmission Systems (송전계통 보호 거리계전기 재정정 영역 판정 전문가시스템 개발)

  • 최면송;민병운;김기화;현승호;이승재
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.8
    • /
    • pp.437-443
    • /
    • 2003
  • In this paper an expert system is developed to decide the resetting area of protective devices in power transmission systems. A configuration change in power transmission networks from a substation extension such as new line or bus addition need resetting of protective devices around the point of configuration changes. To find the resetting area in complex power system is very difficult, especially when the distance protective relays are considered to be reset. The proposed expert system, in this paper to find the resetting area has many rules based on the changes of fault currents and apparent factors from the power system alteration. It solves the problem to find relay resetting area using the network information in the database and the rule-base. The case study shows a result of the problem to find relay resetting area in KEPCO system when there is any configuration change.

Influence of the Large Scaled Wind Farm Interconnected with 154 kV Power Networks on the Distance Relay (154 kV 계통 연계 대규모 풍력단지가 송전선 거리계전기에 미치는 영향)

  • Jang, Sung-Il;Kim, Kwang-Ho;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.334-336
    • /
    • 2003
  • This paper describes the influences of the large scaled wind farm interconnected with 154 kV power networks on the operational characteristics of distance relay applied in the transmission line. The wind farm composed of wind turbine generators are one of the great energy sources: they can supply the power into an interconnected network not only the normal conditions, but also the fault conditions of power network. Therefore, the distance relay applied in the transmission tine may mal-operate due to the contribution of wind farm. This paper presents the operational characteristics of distance relay for the fault occurred in the transmission line interconnected with wind farm. Simulation results show that it is difficult to recognize the fault location due to the power output of wind farm.

  • PDF

Matching Element Sensitivity Analysis for the Operation of a Dual-band Power Amplifier with CRLH Transmission Lines

  • Lee, Byeonguk;Kim, Changwook;Park, Youngcheol
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1050-1055
    • /
    • 2018
  • In this paper, we analyzed the sensitivity of matching elements for the dual-band operation of a power amplifier with composite right/left-handed (CRLH) transmission lines. Metamaterial theory enables CRLH transmission to support arbitrary impedance matching at dual frequencies. In general, at sub-GHz range, the CRLH matching networks are commonly implemented with lumped elements, which are prone to manufacturing distribution. In order to reduce the effect from the distribution of element values in design, we suggest a method to analyze the sensitivity of matching elements from the performance aspect of power amplifiers. Based on the analysis, a 40dBm dual-band power amplifier operating at 0.7GHz and 1.5GHz is designed.