• Title/Summary/Keyword: transmission power

Search Result 5,780, Processing Time 0.035 seconds

An Optimal Rescheduling of Power Generation to Constrain the EM Field Emitted from Power Transmission Lines (송전선로에서 발생하는 전자계 제약을 고려한 발전력의 최적 재분배)

  • Kim, Jong-Hyeong;Sin, Myeong-Cheol;Ra, Wan-Su;Park, Il-Han
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.10
    • /
    • pp.464-471
    • /
    • 2001
  • Power utilities must satisfy both supplying high quality power economically and reducing EMF levels. In general, in order to reduce EMF levels from transmission line, it is effective to install shielding wires, configure wires with minimal space or modify structure of other conductors, etc., but these techniques require much cost and time. To some extent, the EMF levels associated with critical transmission lines can be reduced by redistributing the scheduled power generation, since it can change the power flows. There this technique can be readily applied without modifying other structures. This paper considers the OPF(Optimal Power Flow) with the EMF constraints in transmission lines to determine the power generation redistributions and demonstrates numerically the effectiveness of the approach.

  • PDF

Three-phase high power wireless transmission system (3상 대용량 무선 전력 전송 시스템)

  • Oh, Jungsik;Lee, Myungjin;Cha, Seungtae;Kim, Juyoung;Lee, Kwangwoon;Park, Taesik
    • Journal of IKEEE
    • /
    • v.21 no.3
    • /
    • pp.195-201
    • /
    • 2017
  • High-power wireless transmission system becomes a key technology for the advance of battery-powered devices. The wireless power transfer devices are currently dominated by the inductive and capacitive wireless power transfer systems, which have relatively low power transmission capacity and low efficiency rather than the wired power transmission. The work presented in this paper proposes an alternative method of high-power transmission system, based on a variable speed motor system with a magnetic coupling. It enables high-capacity power transmission, high efficiency, and low possibility of failures, and the performance of the proposed scheme is verified by simulation and experiments.

Examination with Transmission Line Distance Relay Setting Rule Considering Error (오차를 고려한 송전선 보호 거리계전 정정룰에 대한 고찰)

  • Cho, Seong-Jin;Choi, Myeong-Song;Hyun, Seung-Ho;Kim, Joung-Wook;Lee, Joo-Wang;Cho, Bum-Sub;Yoo, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.12-15
    • /
    • 2002
  • Korea Power System Protection Setting Rule was used from the rectify 1990's. Thereafter transmission voltage is raised the voltage into 765kV, and introduction to new technology of Power System, and was many of variation but, it is using. The present is using Digital type distance relay for 765kV transmission line protection. If impedance value of transmission line were to value lower than setting, this would be operating and relay setting rule is for 85% into Zone 1 self section, and Zone 2 is a 125%, Zone 3 is a 225%. Which's $15{\sim}25%$ include current transformer error 5%, potential transformer 5%, relay calculation error 5% and margin factor from the field experience. This paper is discussed transmission protective relay and relay setting rule of high voltage power system and we verify the correctness relay setting rule with distance relay using Matlab simulation.

  • PDF

Opportunistic Scheduling and Power Control for Cross-Layer Design of Ad Hoc Networks (Ad Hoc네트워크의 Cross-Layer설계를 위한 Opportunistic Scheduling과 Power Control기법)

  • Casaquite Reizel;Ham Byung-Woon;Hwang Won-Joo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.9A
    • /
    • pp.856-867
    • /
    • 2006
  • This paper proposes a new algorithm for opportunistic scheduling that take advantage of both multiuser diversity and power control. Motivated by the multicast RTS and priority-based CTS mechanism of OSMA protocol, we propose an opportunistic packet scheduling with power control scheme based on IEEE 802.11 MAC protocol. The scheduling scheme chooses the best candidate receiver for transmission by considering the SINR at the nodes. This mechanism ensures that the transmission would be successful. The power control algorithm on the other hand, helps reduce interference between links and could maximize spatial reuse of the bandwidth. We then formulate a convex optimization problem for minimizing power consumption and maximizing net utility of the system. We showed that if a transmission power vector satisfying the maximum transmission power and SINR constraints of all nodes exist, then there exists an optimal solution that minimizes overall transmission power and maximizes utility of the system.

Establishing Best Power Transmission Path using Receiver Based on the Received Signal Strength

  • Eom, Jeongsook;Son, Heedong;Park, Yongwan
    • Journal of Internet Computing and Services
    • /
    • v.18 no.6
    • /
    • pp.15-23
    • /
    • 2017
  • Wireless power transmission (WPT) for wireless charging is currently attracting much attention as a promising approach to miniaturize batteries and increase the maximum total range of an electric vehicle. The main advantage of the laser power beam (LPB) approach is its high power transmission efficiency (PTE) over long distance. In this paper, we present the design of a laser power beam based WPT system, which has a best WPT channel selection technique at the receiver end when multiple power transmitters and single power receiver are operated simultaneously. The transmitters send their transmission channel information via optically modulated laser pulses. The receiver uses the received signal strength indicator and digitized data to choose an optimum power transmission path. We modeled a vertical multi-junction photovoltaic cell array, and conducted an experiment and simulation to test the feasibility of this system. From the experimental result, the standard deviation between the mathematical model and the measured values of normalized energy distribution is 0.0052. The error between the mathematical model and measured values are acceptable, thus the validity of the model is verified.

Power Transmission Characteristics of a Hydro-Mechanical Transmission (정유압 기계식 변속장치의 동력전달특성)

  • Seong, Deok-Hwan;Kim, Hyeong-Ui;Lee, Geun-Ho;Kim, Hyeon-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.11
    • /
    • pp.1854-1862
    • /
    • 2001
  • In this paper, power flow characteristics of a hydromechanical transmission(HMT) are investigated using network analysis. The HMT used in this study consist of a hydrostatic unit(HSU), planetary gear sets, clutches and brakes providing forward 4 speeds and backward 2 speeds. Since the HMT power flows showing a closed loop and the HSU efficiency varies depending on the pressure and speed, a systematic approach is required to analyze the power transmission characteristics of the HMT. In order to analyze the closed loop power flow and the HSU power loss which changes depending on the pressure and speed, network model is constructed fur each speed range. In addition, an algorithm is proposed to calculate an accurate HSU loss corresponding to the experimental results. It is found from the network analysis that the torque and speed of each transmission element including the HSU can be obtained as well as direction of the power flow by the proposed algorithm. It is expected that the network analysis can be used in the design of relatively complicated transmission system such as HMT.

Study on The Throughput Unfairness of High-power transmission in The Transmission Power Controlled Wireless Networks Considering Green Computing (그린 컴퓨팅을 위한 무선 네트워크 전송 파워 조절에서 고출력 전송의 성능 불공평성에 대한 연구)

  • Lee, Hee-Jin;Kim, Jong-Kwon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.10
    • /
    • pp.27-35
    • /
    • 2010
  • In wireless packet networks, energy and wireless resource efficiency is critical issue to addressed for wide deployment. To achieve the both goals of saving the mobile station's energy and increasing the wireless capacity, transmission power control is introduced to wireless packet networks. In the transmission power controled networks, it is not deeply studied on unfairness among transmissions with different power levels that reaches starvation. Through the performance analysis, this paper explains the throughput unfairness of high power transmission with the unfair media access probability owing to the contending node number difference and proposes a simple PHY-MAC cross layer approach.

Power Characteristics Analysis of Hydro-Mechanical Transmission (정유압기계식 변속장치의 동력특성해석)

  • Sung, Duk-Hwan;Lee, Geun-Ho;Kim, Hyun-Soo
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.519-524
    • /
    • 2001
  • In this paper, power flow characteristics of a hydromechanical transmission(HMT) are investigated using network analysis. The HMT used in this study consist of a hydrostatic unit(HSU), planetary gear sets, clutches and brakes providing forward 4 speeds and backward 2 speeds. Since the HMT power flows showing a closed loop and the HSU efficiency varies depending on the pressure and speed, a systematic approach is required to analyze the power transmission characteristics of the HMT. In order to analyze the closed loop power flow and the HSU power loss which changes depending on the pressure and speed, network model is constructed for each speed range. In addition, an algorithm is proposed to calculate an accurate HSU loss corresponding to the experimental results. It is found from the network analysis that the torque and speed of each transmission element including the HSU can be obtained as well as direction of the power flow by the proposed algorithm. It is expected that the network analysis can be used in the design of relatively complicated transmission system such as HMT.

  • PDF

A Windows-based Software for Education and Training of Transmission Network Charge (송전망 이용요금 산정을 위한 교육용 시뮬레이터 개발)

  • Kim, Hyun-Houng;Cho, Ki-Seon;Jeong, Yun-Won;Park, Jong-Bae;Shin, Joong-Rin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1373-1381
    • /
    • 2007
  • This paper presents a graphical windows-based software for the education and training of transmission network charge. The motivation for the development of the simulator is to provide students with a simple and useable tool for gaining an intuitive feel for transmission network charge. The developed simulator consists of the main module (MMI, GUI), the power flow module (PF), the power flow tracing module (PFT), and usage cost DB module (UCD). Each module has a separate graphical and interactive interfacing window. The developed simulator provides with two power system analysis methods (i.e., DC-PF and Modified DC-PF) and supports the PSS/E input data format to load input data of power system. Also, power flow tracing can be calculate using four methods such as "Felix Wu", "Modified Felix Wu", "DCLF ICRP", and "Reverse MW mile". Results of calculation for transmission usage cost are displayed and compared on the window through the table and/or chart. Therefore, the developed simulator can be utilize as a useful tool for effective education and training of transmission network charge.

345kV Overhead Transmission Line Collapse Analysis and Countermeasures (345kV 인천화력 송전선로 철탑도괴 원인분석 및 대책)

  • Park, Jae-Ung;Shin, Tai-Woo;Choi, Jin-Sung;Choi, Han-Yeol;Min, Byeong-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.531-535
    • /
    • 2010
  • 345kV Incheon Thermal Power Plant Transmission Line Collapse Analysis and Countermeasures. The Typhoon Galmaegi which had been formed in July 15, 2008 diminished into a tropical cyclone and cooled the air above the West Sea. The cooled air colliding with the warm inland air caused a strong whirlwind at some places in the west seaside; the whirlwind battered the 345kV Incheon Thermal Power Plant Transmission Line to be collapsed. The resistance of transmission towers against wind pressure, one of the key elements in transmission line engineering, is designed to endure the pressure corresponding to the maximum instantaneous wind speed. Before the above accident happened, no transmission line has ever been collapsed by a whirlwind. So this paper is aimed to analyze causes that collapsed 345kV Incheon Thermal Power Plant transmission line and to introduce countermeasures.