An Analysis of the Transmission Performance Degradation Cased by the ADSL Subscriber Line Environment (ADSL 가입자선로 환경에 따른 전송성능 저해요인)

  • 김원근;김기현;이종영
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.218-221
    • /
    • 2003
  • In this report, we test the features that the outside environment of subscriber lines have an effects on ADSL's electrical transmission performance with a suspected cases of line. I observed an influence of AM broadcasting jamming, and also analysis of an incoming lines of various kinds, a line distance, a connection way, Bridge Tap influencing ADSL's electrical transmis-sion performance. To have a maximum effect of Adsl electrical transmission, I came to a conclusion that we have to make use of the older copper wire cable line to fit the situation at the present and we must change it into the excellent optical fiber cable one by one.

  • PDF

Analysis of Crosstalk Reduction by Metal Filled Via Hole Fence in Bent Transmission Lines (구부러진 전송선에서 비아 홀 펜스에 의한 누화 감소 해석)

  • Kim Jong-Ho;Han Jae-Kwon;Park Dong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.10 s.101
    • /
    • pp.1036-1042
    • /
    • 2005
  • The crosstalk between bent transmission lines and the effects of additional trace with the metal filled via holes on alleviating the crosstalk are investigated using the circuit concept approach for transmission line sections and impedance modeling for via hole sections. All sections are represented by ABCD matrices and then cascaded. Finally the calculated results by proposed method are confirmed that they agree with the measured results in less than 3 dB except a band of low frequency.

Calculation of the induced voltage and current for a human and a car close to 765 kV AC double circuit transmission line (765 kV 교류 2회선 송전선 하의 인체 및 자동차에 유도되는 전압, 전류 계산)

  • 민석원;김응식;명성호;이병윤;박종근
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.301-309
    • /
    • 1996
  • This paper estimates the electric field effect near 765[kV] AC double transmission line with numerical data. The induced voltage and current of a human and car under who kinds of phase arrangement are calculated when each of two objects is insulated or grounded. When the calculated results of the low-reactance and superposition phase arrangement are compared, it is proved that the induced voltage and current of the former are about 30 [%] smaller than that of the latter. The induced current of a human and car are less than 0.5[mA] which is about 10[%] less than that of the American National Standard Code. Also the induced voltage and current of dead lines by other live lines are calculated. Finally the effective number and position of shield wires to reduce the field in ground level are considered. charge simulation method and surface charge method are used to simulate the 2 or 3 dimensional transmission line model respectively.

  • PDF

Security Monitoring System for Apartment House Building Using Paver Line Carrier (전력선 통신을 이용한 집단주택 안전관리 시스템)

  • Kim, In-Soo;Kim, Kwan-Ho;Kim, Yo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.476-478
    • /
    • 1993
  • Instead of installing new communication wiring to each house in the apartment house building. the power distribution network. which is already installed in the building. can be use as communication medium. In a safty management, by adoption of power line communication system, at remote we can monitor safty related sensors such as fire, gas leakage, burglar intrusion and emergency call which are located at each house. From this viewpoint, we developed security monitoring system for apartment house building using power lines. Security monitoring system consists of Power Line Communication-Sub Controller (PLC-SC). Power Line Communication-Main Controller (PLC-MC) and Management System (MS). Between a PLC-MC and a PLC-SC, the transmission rate is 1200 bps in power lines and modulation technique is frequency shirt keying (FSK). In between a PLC-MC and a MS, the transmission rate is 1200 bps in communication line (RS-485). As a result of this research. transmission loss is 0.1dB per meter of intrabuilding distribution network. Transmission can be reach in 250 meters. So it is enough to communicate for security monitoring system in apartment house building.

  • PDF

A Design of Dual Band Amplifier Using Left Handed Transmission Lines (LH 전송선로를 이용한 이중대역 증폭기의 설계)

  • Lim, Jong-Sik;Lee, Jae-Hoon;Lee, Jun;Koo, Ja-Kyung;Jeong, Yong-Chae;Han, Sang-Min;Ahn, Dal
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.2032-2037
    • /
    • 2010
  • This paper describes a design of dual band amplifier using left handed (LHJ) transmission line, which is a part of composite right/left handed (CRLH) transmission line. It is well known that CRLH transmission lines show dual band frequency response. At first, two single-band amplifiers for frequency f1 and f2 are designed, and their matching networks at both amplifiers are synthesized into the dual band matching network by adopting CRLH structure. As an example for proving the validity of the proposed design, a dual band amplifier operating at 1800MHz and 2300MHz is designed, fabricated and measured. The simulation and measurement show that the proposed amplifier operates well at the desired dual bands with the gain of 13.65dB and 19dB at 1850MHz and 2360MHz, respectively, and a good matching performances. In addition, a quite good agreement between the simulation and measurement is observed.

A Study on Estimation of Breakdown Location using UHF Sensors for Gas Insulated Transmission Lines (UHF센서를 이용한 가스절연송전선로 절연파괴 위치 추정에 관한 연구)

  • Park, Hung-Sok;Han, Sang-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.805-810
    • /
    • 2011
  • This paper deals with the method and algorithm used to find fault locations in gas insulated transmission line. The method uses UHF sensors and digital oscilloscope to detect discharge signals emitted to the outside through insulating spacer in the event of breakdown inside GIL. UHF sensors are the external type and installed at outside of insulating spacers of GIL. And we used wavelet signal processing to analyze the discharge signals and confirm the exact fault location findings in the GIL test line. This method can overcome demerit of TDR(Time Domain Reflectometer) method having been applied to detect fault location for conventional underground transmission lines, and Ground Fault Sensors used in conventional GIS systems. TDR method requires high level of specialty and experience in analyzing the measured signals. Ground fault sensors are installed inside GIL and can be destroyed by high transient voltage. This paper's method can simplify the fault location process and minimize the damage of sensors. In addition, this method can estimate the fault location only by the time difference when discharge signals are arrived to detecting sensors at the ends of GIL sections without reasons of breakdown. To test the performance of our method, we installed sensors at the ends of test line of GIL(84m) and sensed discharge signals occurred in GIL, energized with AC voltage generator up to 700kV.

A study on the Site Survey and Detection Efficiency for Kepco Lightning Detection and Information Network (낙뢰측정 네트워크(KLDNet)를 위한 감지기 사이트서베이와 낙뢰 감지율 검토)

  • Woo, J.W.;Kwak, J.S.;Moon, J.D.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.11
    • /
    • pp.532-537
    • /
    • 2006
  • Lightning induced faults accounts for more than 66% at the transmission lines of KEPCO. The lightning causes damages to power system equipments including transmission line, the blackout of electricity and the electro-magnetic interference. Because of this reason, we need the real time lightning information for the optimal operation of power system. And, it is required to obtain and accumulate the lightning current parameters for the insulation design. In 2005, KEPRI constructed a lightning detection network, the KLDNet (i.e. Kepco Lightning Detection & Information System) and launched a lightning information service for KEPCO customers. It is intended to provide data service on the operation of transmission lines and collect lightning-related data, which is the most important factor regulating power system design and operation. The new system will replace LPATS, the old detection system, which has been operating since 1995 and is rapidly failing in terms of both detection performance and location accuracy. The purpose of this paper is to explain the work performed and the results of that work in performing a site survey of several locations. The purpose of the site survey is to find locations acceptable for the installation of a lightning location receiver in support of a Lightning detection system(LDS). A restriction was placed on the surveyed locations, as they must belong to the Korea Electric Power Company. This requirement was made to facilitate the communication needs of the LDS network. Total of 15 sites were evaluated as possible LDS sensor sites. Some of the sites were rejected for physical reasons and therefore no electrical testing was performed. Of the 15 sites, total of 10 sites were considered acceptable and 5 sites were rejected for various reason. In this paper, we would like to explain the site survey and detection efficiency for LDS.

The Dual-Mode Ring-Resonator Bandpass Filter Using Artificial-Transmission-Lines (인공전송선로를 이용한 이중모드 링-공진기 대역통과 여파기)

  • Sim, Kyung-sub;Hwang, Hee-yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.5
    • /
    • pp.424-429
    • /
    • 2016
  • This paper presents dual-mode ring-resonator bandpass filter using LUC of artificial-transmission-lines. The conventional ring-resonator bandpass filter has limitation in miniaturization because the conventional ring-resonator is based on a one wavelength operation, and problem due to undesire harmonics. The ring-resonator bandpass filter is miniaturized and show higher order mode rejection by configuring a ring-resonator with LUC of artificial-transmission-lines. The two-stage bandpass filter is designed and fabricated with a ring-resonator and input/output interdigital coupled line. A fabricated filter shows dual-mode, rejection of whole ultra wide band, sharp skirt characteristics and has ring area reduced by 60 % compared to the conventional ring-resonator bandpass filter.

A Study on Utilization Ratio and Operation of Transmission Lines (송전선로의 이용률 평가 및 합리적 운영에 관한 연구)

  • Kim, Dong-Min;Bae, In-Su;Cho, Jong-Man;Kim, Jin-O
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.10
    • /
    • pp.426-432
    • /
    • 2006
  • This paper describes the concepts of Static Line Rating (SLR) and Dynamic Line Rating (DLR) and the computational methods to demonstrate them. Calculation of the line capacity needs the heat balance equation which is also used for computing the reduced tension in terms of line aging. SLR is calculated with the data from the worst condition of weather throughout the year. Even now, the utilization ratio is obtained from this SLR data in Korea. DLR is the improved method compared to SLR. A process for DLR reveals not only improved line ratings but also more accurate allowed line ratings based on line aging and real time conditions of weather. In order to reflect overhead transmission line aging in DLR, this paper proposes the method that considers the amount of decreased tension since the lines have been installed. Therefore, the continuous allowed temperature for remaining life time is newly acquired. In order to forecast DLR, this paper uses weather forecast models, and applies the concept of Thermal Overload Risk Probability (TORP). Then, the new concept of Dynamic Utilization Ratio (DUR) is defined, replacing Static Utilization Ratio (SUR). For the case study, the two main transmission lines which are responsible for the north bound power flow in the Seoul metropolitan area are chosen for computing line rating and utilization ratio. And then line rating and utilization ratio are analyzed for each transmission line, so that comparison of the present and estimated utilization ratios becomes available. Finally, this paper proves the validity of predictive DUR as the objective index, with simulations of emergency state caused by system outages, overload and so on.

Fabrication of novel micromachined microstrip transmission line for millimeter wave applications (마이크로머시닝 기술을 이용한 새로운 형태의 고주파 저손실 Microstrip 전송선의 제작)

  • 이한신;김성찬;임병옥;신동훈;김순구;박현창;이진구
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.8
    • /
    • pp.37-44
    • /
    • 2004
  • This paper describes a new GaAs-based surface-micromachined microstrip line supported by dielectric post and air-gapped signal line with ground metal. This new type of dielectric-supported air-gapped microstripline(DAML) structure is developed using surface micromachining techniques to provide easy means of airbridge connection between the signal lines and to archive low losses at millimeter-wave frequency band with wide impedance range. Each DAMLs with the length of 5 mm are fabricated and the measured characteristics are compared with those of the conventional microstrip transmission line. These transmission lines are composed of 10 ${\mu}{\textrm}{m}$ height of signal line, post size of 10 ${\mu}{\textrm}{m}$ ${\times}$ 10 ${\mu}{\textrm}{m}$ and post height of 9 ${\mu}{\textrm}{m}$. By elevating the signal lines from the substrate using the micromachining technology, the substrate dielectric loss can be reduced Compared with of the conventional microstrip transmission line showing 7.5 dB/cm loss at 50 GHz, the loss can be reduced to 1.1 dB/cm loss at 50 GHz.