• 제목/요약/키워드: transmission line

검색결과 3,297건 처리시간 0.068초

조류에 의한 가공송전선로의 고장분석 및 예방대책 고찰 (The Study for Analysis and Prevention Measure of Overhead Transmission Line Fault with Birds)

  • 정시환;강철원;김완식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.96-98
    • /
    • 2006
  • Recently major power outages are increased, because of transmission line fault by birds. Therefore, after finding out the problem of the current prevention measure for the super high voltage transmission Line in Korea and analyzing the protection measure of other foreign power companies for the transmission facilities fault by birds, this paper describes an effective device for power line fault protection by birds which has no legal problem and also protects birds. The described prevention measure of power outage by birds in this paper, has a special feature that is able to be installed on the current overhead transmission facilities without a replacement or change.

  • PDF

점탄성감쇠기를 이용한 송전철탑 풍하중의 저감 (Wind Load Mitigation for Transmission Tower using Viscoelastic Damper)

  • 민경원;박지훈;문병욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.955-958
    • /
    • 2005
  • In this study, the wind load characteristics for a transmission tower is investigated considering the effect of the transmission lines through stochastic analysis. The assemblage of the transmission line and insulator are modeled as a double pendulum system connected to the SDOF model of the tower It is observed that the background component of the overturing moment induced by the wind response of the transmission line has considerable portion in the total overturning moment. Based on this result, a rotational viscoelastic damper (VED) is proposed for the mitigation of the transmission line reactions, which act as wind load transferred to the tower. To verify the effectiveness of the proposed strategy, time history analysis is conducted for different wind velocities and VED damping constants. From the analysis, the proposed VED is proved to be effective for mitigation of the background component rather than the resonance component of the transmission line reaction.

  • PDF

송전 선로의 사고 거리에 따른 특성 주파수 해석 (Analysis of Characteristic Frequency along Fault Distance on a Transmission Line)

  • 남순열;홍정기;강상희;박종근
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권8호
    • /
    • pp.432-437
    • /
    • 2004
  • Since the characteristic frequency is decreased in proportion to the fault distance, the characteristic frequency component may be insufficiently eliminated by a low-pass filter on a long transmission line. In order to set a standard for the cut-off frequency of the low-pass filter, this paper proposes a method for obtaining the characteristic frequencies due to line faults. The application results of the proposed method are presented for line to ground (LG) faults and line to line (LL) faults on a 345 kV 200 km overhead transmission line. The EMTP is used to generate fault signals under different fault locations and fault inception angles. By comparison between the characteristic frequencies obtained from the proposed method and the EMTP simulation, it is shown that the proposed method accurately obtains the characteristic frequency.

RLH-TL (Right/left-handed transmission line)을 이용한 8 port 전력 분배기 설계 및 분석 (Design and Analysis of 8-Port Power Divider for Using RLH-TL(Right/Left-Handed Transmission Line))

  • 김형미;이범선
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.29-32
    • /
    • 2005
  • 본 논문에서는 right/left-handed특성을 이용한 8 포트 동위상 전력분배기를 제안한다. 이 전력분배기는 사용되는 전송선의 전기적 길이에 상관없이 동위상 분배가 가능하기 때문에 전력 분배기의 크기를 크게 줄일 수 있다. 전력분배기에 사용되는 전송선의 길이가 짧을수록 광대역 특성을 보이며 분배기의 크기는 줄어든다.

  • PDF

345kV 인천화력 송전선로 철탑도괴 원인분석 및 대책 (Analysis and Countermeasures of 345kV Incheon-TP Overhead Transmission Lines Collapse)

  • 민병욱;신태우;최진성;최한열;박재웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.323_324
    • /
    • 2009
  • 345kV Incheon Thermal Power Plant Transmission Line Collapse Analysis and Countermeasures. The Typhoon Galmaegi which had been formed in July 15, 2008 diminished into a tropical cyclone and cooled the air above the West Sea. The cooled air colliding with the warm inland air caused a strong whirlwind at some places in the west seaside; the whirlwind battered the 345kV Incheon Thermal Power Plant Transmission Line to be collapsed. The resistance against wind pressure, one of the key elements in transmission line engineering, is designed to endure the pressure corresponding to the maximum instantaneous wind speed. Before the above accident happened, no transmission line has ever been collapsed by a whirlwind. So this paper is aimed to analyze causes that collapsed 345kV Incheon Thermal Power Plant transmission line and to introduce countermeasures.

  • PDF

전력전송구간을 분할하여 데이터 신호를 전송하는 전력선 통신방법 (Power Line Communication Method with Splitting of Power Transmission Interval)

  • 조재승;황일규
    • 전력전자학회논문지
    • /
    • 제17권3호
    • /
    • pp.252-258
    • /
    • 2012
  • This paper studies the power line communication method with splitting of power transmission interval in the small DC power system using pulse width modulation. The method divides the entire interval for transmitting power and data into a power transmission interval where power is supplied to a load and a data transmission interval where power from the power supply to the load is disconnected. The circuit is designed for the implementation to separate the power line from the power supply and load. The results of tests show the feasibility of the proposed power line communication method.

Dual-Transmission-Line Microstrip Equiripple Lowpass Filter with Sharp Roll-Off

  • Velidi, Vamsi Krishna;Sanyal, Subrata
    • ETRI Journal
    • /
    • 제33권6호
    • /
    • pp.985-988
    • /
    • 2011
  • A novel application of a dual-transmission line is proposed to design a lowpass filter (LPF). The proposed structure uses only transmission line elements to produce an equiripple LPF response with sharp roll-off. Design equations are derived using a lossless transmission line model. Controlling the electrical lengths, three transmission-zeros are realized in the stopband to obtain a sharp roll-off rate and wide stopband bandwidth. A single unit microstrip LPF with a 3-dB cut-off frequency at 1.0 GHz having a roll-off of 135 dB/GHz along with a stopband bandwidth of 69.5% is designed for validation.

송전선에 의해 송전철탑에 전달되는 풍하중 저감을 위한 회전형 점탄성감쇠기 (Rotational Viscoelastic Dampers for the Mitigation of Wind Loads on Transmission Tower Transferred from Transmission Lines)

  • 문병욱;민경원
    • 한국소음진동공학회논문집
    • /
    • 제16권4호
    • /
    • pp.420-427
    • /
    • 2006
  • In this study, wind loads transmitted to a transmission tower from transmission lines are mitigated using rotational viscoelastic dampers. First, the wind load characteristics in a transmission tower is investigated considering the effect of the transmission lines through stochastic analysis. The assemblage of the transmission line and insulator are modeled as a double pendulum system connected to the SDOF model of the tower. From the result of the stochastic analysis, the background component of the overturing moment caused by the wind loads acting on the transmission lines are found to have considerable portion in the total overturning moment. Based on this observation result, a strategy Installing rotational viscoelastic damper (VED) between tower arm and transmission line is proposed for the mitigation of the transmission line reactions, which play a role as dynamic loads on a transmission tower. For the purpose of verification, time history analysis is conducted for different wind velocities and VED parameters. The analysis result shows that the rotational VED is effective for the mitigation of the background component rather than the resonance component of the transmission line reactions and achieves the reduction ratio of 50% even for higher wind speed.

삼각 패치형 인공 전송 선로를 이용한 브랜치 라인 하이브리드 (A Branch-Line Hybrid Using Triangle-Patch Type Artificial Transmission Line)

  • 오송이;황희용
    • 한국전자파학회논문지
    • /
    • 제23권7호
    • /
    • pp.768-773
    • /
    • 2012
  • 본 논문에서는 슬롯을 갖는 삼각 패치형 인공 전송 선로를 이용한 브랜치 라인 하이브리드를 제안한다. 제안된 인공 전송 선로는 구조가 콤팩트하고 슬롯의 파라미터들을 변화시킴으로써 선로의 특성 임피던스와 전기적 길이를 조절하는 데 용이하여 일반적인 전송 선로를 소형화시키는 데 유용하다. 제안된 브랜치 라인 하이브리드는 이러한 직각 삼각형의 인공 전송 선로들을 이용하여 구현되었기 때문에 공간의 활용도가 높고 소형화되었다. 제작된 3 dB 브랜치 라인 하이브리드는 중심 주파수 2.45 GHz의 15 % 대역폭 내에서 ${\pm}0.5$ dB의 결합도 변화 특성과 두 출력 포트 간 $91^{\circ}{\pm}4^{\circ}$의 위상차 특성을 보였다. 또한, 제안된 브랜치 라인 하이브리드의 크기는 일반적인 브랜치 라인 하이브리드 크기의 38 %이다.

CPW와 Offset 결합 전송선로를 이용한 비대칭 다단 분배기 (Unequal Multi-Section Power Divider using CPW and Offset Coupled Transmission Lines)

  • 최종운;윤영철;성규제;김영
    • 한국항행학회논문지
    • /
    • 제23권4호
    • /
    • pp.309-315
    • /
    • 2019
  • 본 논문은 1:3과 1:4 분배 비율을 갖는 비대칭 분배기를 CPW와 offset 결합 전송선로를 이용하여 다단 구조로 구현한 것이다. 이 분배기는 다단 구조의 전송선로와 캐패시터와 저항이 병렬로 연결된 회로로 구성되어 있다. 다단 전송선로는 임의의 임피던스로 종단된 ${\lambda}/4$ 단일 전송선로를 분해하여 그것을 $90^{\circ}$ 전기적 길이보다 짧은 다단 전송선로로 정합시키는 방법으로 구현하였고, RC 병렬회로는 출력 포트의 반사계수와 출력 포트 사이의 고립 특성을 얻기 위해서 전송선로 사이에 연결하였다. 이러한 방법으로 2 GHz에서 설계된 전력분배기는 각 단의 전송선로는 ${\lambda}/4$보다 짧게 구현되어 기존 것 보다 최소 27% 작게 구현하였고, 광 대역 특성을 얻을 수 있음을 확인하였다.