• 제목/요약/키워드: transmission line

검색결과 3,297건 처리시간 0.034초

EMTDC를 이용한 765/345kV 병가선로의 불평형 계통 해석 (Unbalanced Power System Analysis in 765/345kV Parallel Transmission Line by Using EMTDC)

  • 김종율;윤재영;최흥관;이운희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.199-201
    • /
    • 2003
  • Because of Korean power system characteristics and increasing power demand, the need of 765kV transmission line is growing gradually. Now a days, KEPCO's 765kV transmission line has been tested and stands for commercial operation. During the first stage, 765kV transmission line will be operated with two voltage grades of 765kV and 345kV, which results the unbalance of power system. So unbalanced current such as zero sequence current flows in the transmission line. In this paper, we describes the simulation study of 765/345kV parallel transmission line by using EMTDC program.

  • PDF

사고현장과 사령실간 화상전송기술에 관한 연구(III) (A Study on the moving picture transmission method between the accident sites and control center)

  • 조봉관;장석각;최규형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1412-1414
    • /
    • 2004
  • Railway takes an important role of transporting massive passenger and freight. Accidents which occur related to trains have a risk of serious loss of lives, so those accidents need to be controlled urgently. Therefore moving picture transmission system is required which transmits exact information of moving picture of accident status to CTC and also communication line is also required with it. By using WTB line as a wayside transmission line, railway telephones, fax and train service information are provided to local offices. As transmission line improving project, optical cabling work is being processed by phases. Therefore optical fiber line is more effective way for a communicating way between stations than coaxial transmission line. This paper consider's connecting method when optical fibers is used for moving picture data transmission of train accidents and its problems.

  • PDF

지게차용 동력전달장치의 조립라인 전용시험기 개발 (Development of the Assembly Line Tester of Power Transmission for Lift Truck)

  • 장경열;유우식
    • 산업공학
    • /
    • 제23권1호
    • /
    • pp.58-67
    • /
    • 2010
  • The purpose of this paper is to present the development processes of the assembly line tester of power transmission for lift truck. Because power transmission is most important part of lift truck, all assembled powertrain parts must be inspected for operational defects, pressures and RPM. Developed assembly line tester is designed to take about 25 minutes for inspecting each assembled power transmission and located it at the end of assembled line. The assembly line no-load tester consists of three parts: (1) the driving hardware part; for installing and operating the transmission. (2) control PCB part; send data from sensors to a computer and control driving part, (3) operation software of no-load tester; for an automatic inspection or manual inspection, for database management and printing transcripts.

Coupled Line으로 구성된 작고 넓은 대역폭을 가지는 3-dB Ring Hybrids (Compact and Wideband Coupled-Line 3-dB Ring Hybrids)

  • 안희란;김정준;김범만
    • 한국전자파학회논문지
    • /
    • 제19권8호
    • /
    • pp.862-877
    • /
    • 2008
  • 두 종류의 넓은 대역폭을 갖는 ring hybrids(하나는 coupled line이 포함되어 있고, 다른 하나는 left-handed transmission line을 포함한 ring hybrids)가 비교되었으며, 비교 결과로부터 coupled line을 포함한 ring hybrid가 모든 면에서 우수한 특성을 가짐을 보여줬다. 그러나, coupled line을 포함한 ring hybrid는 -3 dB coupling power를 가질 경우에 한해서만이 perfect matching이 이루어지기 때문에, perfect matching을 갖는 coupled line ring hybrid는 2차원으로 구현하기는 거의 불가능하다. 이 문제를 해결하기 위해서 coupled line을 해석했고, 그 해석 결과로부터 coupling coefficient에 관계없이 어느 경우에도 perfect matching을 이룰 수 있는 설계 식을 유도했다. 이 설계식을 이용하여, transmission line의 길이가 ${\pi}$보다 큰 경우에도 적용될 수 있는 크기를 줄이기 위한 새로운 형태의 transmission line 등가회로를 제시했다. 이 새로운 형태의 transmission line의 등가회로를 이용하면 기존의 ring hybrid의 $3\;{\lambda}/4$의 transmission line을 줄이는 데 사용할 수 있기 때문에 ring hybrid의 크기를 더욱 줄이는데 장점이 될 수 있다. 이 등가회로를 증명하기 위해서, coupling power를 고정하고 또는 transmission line의 길이를 고정하는 2가지 형태의 simulation을 하였으며, 대역폭은 coupled line의 coupling power에 직접적인 상관 관계가 있음을 보였다. 기존의 등가회로와 새로운 형태의 등가회로를 이용하여, 작고 넓은 대역폭을 가지는 ring hybrid를 제시하였다. 새로 제시된 ring hybrid를 이용하여, 기존의 ring hybrid와 비교하였다. 비교 결과로부터, 본 논문에서 제시한 ring hybrid의 전체 ring 둘레가 1/3보다 더 작음에도 불구하고, 대역폭이 훨씬 넓음을 보여줬다. 작고 넓은 대역폭을 가지는 ring hybrid를 측정했으며, 측정 결과는 -2.78 dB, -3.34 dB, -2.8 dB, -3.2 dB의 power division 특성을 보여줬으며, matching과 isolation은 20 % 이상의 대역폭에서 -20 dB보다 좋은 특성을 보여줬다.

송전선로 DC화에 따른 융통조류 마진 분석 (Analysis of system power flow margin on replacement of transmission line to DC line)

  • 황성철;이재형;황평익;윤민한;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.420-421
    • /
    • 2015
  • Recently construction of new transmission line is getting harder because of social hostility to transmission tower. Howevere, load is converged in metropolitan area and power plants near this area are old and life of generator will end soon. Therefore, power to supply load in this area should be transmitted from east coast area and southern area. For these reasons, securement of transmission capacity without new transmission line construction is important. In this paper, effect of one circuit AC line change to DC transmission at the same transmission tower on the system available transfer capacity is analyzed.

  • PDF

A Coupled-Field Analysis of Galloping for Power Transmission Line

  • Kim, Hwan-Seong;Nguyen, Tuong-Long;Byun, Gi-Sig
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.74.3-74
    • /
    • 2002
  • . A Coupled-Field Analysis of Galloping for Power Transmission Line . Fluid-Structure interaction, Galloping, Power Transmission Line, ANSYS

  • PDF

765kV 2회선 송전선로를 765kV 및 345kV로 병행운전시 유도현상 예측 (Analysis of the electrostatic induction voltage and electromagnetic induction current on the Parallel Circuit in 765kV Double Circuit Transmission Line)

  • 우정욱;심응보;곽주식;전명렬;김기일;김태옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.169-171
    • /
    • 2002
  • The western route of KEPCO's 765kV transmission line has been tentatively operating as 345kV voltage before commercial operation. After finishing the test operation of 765kV substation in 2002. KEPCO decided to operate the 765kV line for commercial operation. During the applying of 765kV voltage to the transmission line, double circuit transmission line will be operated with two voltage grades of 765kV and 345kV. Because the earthing switch is installed on both end of transmission line, we had estimated the electrostatic induction voltage and electromagnetic induction current before the line energizing in order to confirm the ratings of earthing switch. The induced voltage and current is very important for the maintenance of parallel circuit. This paper describes the simulation study of electrical phenomena such as electrostatic induction voltage from the parallel line and electromagnetic induction current from the parallel circuit. The transmission line model was developed by EMTP (Electro-Magnetic Transient Program).

  • PDF

MMIC상에서 주기적으로 배치된 용량성 소자를 이용한 단파장 전송선로 (A Short Wavelength Transmission Line Employing Periodically Arrayed Capacitive Devices on MMIC)

  • 정장현;강석엽;윤영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권6호
    • /
    • pp.840-845
    • /
    • 2010
  • 본 논문에서는 MMIC상에서 온칩용 수동소자 제작을 위해서, 주기적으로 배치된 용량성 소자를 이용한 단파장 전송선로를 제안하였다. 제안된 PACD(periodically arrayed capacitive devices) 선로 구조는 기존의 마이크로스트립 선로에 비해 매우 짧은 선로파장 특성을 보였다. PACD 선로 구조는 주파수 5GHz에서 기존의 마이크로스트립 선로 파장의 8%의 파장단축 효과를 보였고, PPGM구조의 선로 파장의 38%의 파장단축 효과를 나타내었다. 이러한 PACD선로 구조는 MMIC상에서 온칩용 수동소자 제작에 유용한 특성으로 판단된다.

Response evaluation and vibration control of a transmission tower-line system in mountain areas subjected to cable rupture

  • Chen, Bo;Wu, Jingbo;Ouyang, Yiqin;Yang, Deng
    • Structural Monitoring and Maintenance
    • /
    • 제5권1호
    • /
    • pp.151-171
    • /
    • 2018
  • Transmission tower-line systems are commonly slender and generally possess a small stiffness and low structural damping. They are prone to impulsive excitations induced by cable rupture and may experience strong vibration. Excessive deformation and vibration of a transmission tower-line system subjected to cable rupture may induce a local destruction and even failure event. A little work has yet been carried out to evaluate the performance of transmission tower-line systems in mountain areas subjected to cable rupture. In addition, the control for cable rupture induced vibration of a transmission tower-line system has not been systematically conducted. In this regard, the dynamic response analysis of a transmission tower-line system in mountain areas subjected to cable rupture is conducted. Furthermore, the feasibility of using viscous fluid dampers to suppress the cable rupture-induced vibration is also investigated. The three dimensional (3D) finite element (FE) model of a transmission tower-line system is first established and the mathematical model of a mountain is developed to describe the equivalent scale and configuration of a mountain. The model of a tower-line-mountain system is developed by taking a real transmission tower-line system constructed in China as an example. The mechanical model for the dynamic interaction between the ground and transmission lines is proposed and the mechanical model of a viscous fluid damper is also presented. The equations of motion of the transmission tower-line system subjected to cable rupture without/with viscous fluid dampers are established. The field measurement is carried out to verify the analytical FE model and determine the damping ratios of the example transmission tower-line system. The dynamic analysis of the tower-line system is carried out to investigate structural performance under cable rupture and the validity of the proposed control approach based on viscous fluid dampers is examined. The made observations demonstrate that cable rupture may induce strong structural vibration and the implementation of viscous fluid dampers with optimal parameters can effectively suppress structural responses.

기체 전달 관로에 있어서 압력 전파의 주파수 응답에 대한 부하 임피던스의 영향 (The Effect of Load Impedances on the Frequency Response of Pressure Propagation in the Pneumatic Transmission Line)

  • 윤선주;손병진
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.344-353
    • /
    • 1994
  • This study numerically analyzed the dynamic characteristics of the frequency response on the pneumatic transmission line with load impedances. The pressure transfer function is represented by the distributed parameter line model. To validate the mathematical approximations of Bessel function ratios, the results of frequency response in a blocked line were compared with those obtained by the Infinite-product, Brown's and Square-root approximations. Special emphasis was given to the frequency response characteristics on the pneumatic transmission line with load impedances. Computations were carried out for the wide range of parameters in terms of load capacitance ratio and load resistance ratio. The present results indicated that the theoretical model is capable of accurately predicting the frequency response characteristics for any configuration of a fluid transmission line.

  • PDF