• Title/Summary/Keyword: transmission distance

Search Result 1,229, Processing Time 0.036 seconds

Lifetime Improvement of Wireless Sensor Network using the Distribution of a Transmission Distance in the SEP (SEP에서 전송 거리 분배를 이용한 무선 센서 네트워크 수명 개선)

  • Lee, Chang-Hee;Lee, Jong-Yong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.5
    • /
    • pp.133-138
    • /
    • 2015
  • In this paper, we propose a method for improving the lifetime of the sensor network SEP through the wireless sensor network divided into two spaces by reducing the transmission distance of the cluster head in the layer in the distance. With reference to the position information of the node, the base station divides the layer based on the midpoint of the nearest node and the furthest distance away from the base station node. And the cluster head in the outer layer far from the base station is transmitted the data to the base station via the cluster head in the inner layer base station to transmit data. That is, we are proposed the layered SEP by reducing the transmission distance of the cluster head in the outer layer for the energy consumption to a minimum. The proposed algorithm is verified by comparison with the existing SEP.

The Real-Time Distance Relay Algorithm Using fault Location Estimation Information for Parallel Transmission Line (병행 2회선 송전선로에서 고장점 위치 추정정보를 이용한 실시간 거리계전 알고리즘)

  • 이재규;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.3
    • /
    • pp.183-192
    • /
    • 2003
  • This paper presents the real-time implemented distance relay algorithm which the fault distance is estimated with only local terminal information. When a single-phase-to-earth fault on a two-parallel transmission line occurs, the reach accuracy of distance relay is considerably affected by the unknown variables which are fault resistance, fault current at the fault point and zero- sequence current of sound line The zero-sequence current of sound line is estimated by using the zero sequence voltage which is measured by relaying location Also. the fault resistance is removed at the Process of numerical formula expansion. Lastly, the fault current through a fault point is expressed as a function of the zero-sequence current of fault line, zero-sequence current of sound line, and line, and fault distance. Therefore, the fault phase voltage can be expressed as the quadratic equation of the fault distance. The solution of this Quadratic equation is obtained by using a coefficient of the modified quadratic equation instead of using the square root solution method. After tile accurate fault distance is estimated. the mote accurate impedance is measured by using such an information.

Damage Process Appraisal of Gears in Automobile Transmission (자동차 트랜스미션 기어의 손상과정 평가)

  • 배효준;조연상;이충엽;서영백;박흥식
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.272-278
    • /
    • 1999
  • It is the effective method to diagnosis damage process of gear system such as automobile transmission to observe wear particle in gear oil. We tested with new transmission and took out gear oil according to drive distance. 4 shape parameters of wear particles in gear oil were calculated and wear volume were presumed with the image processing system. To be applied to damage diagnosis of gear system in transmission of automobile, we discuss number of wear particles, shape characteristics and total wear volume according to driving distance.

  • PDF

A Study on Digital Fault Locator for Transmission Line (송전선로용 디지털 고장점 표정장치에 관한 연구)

  • Lee, Kyung-Min;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.291-296
    • /
    • 2015
  • Transmission line is exposed to a large area, and then faults are likely to occur than the other component of power system. When a fault occurs on a transmission line, fault locator helps fast recovery of power supply on power system. This paper deals with the design of a digital fault locator for improvement accuracy of the fault distance estimation and a fault occurrence position for transmission line. The algorithm of a fault locator uses a DC offset removal filter and DFT filter. The algorithm utilizes a fault data of GPS time synchronized. The computed fault information is transmitted to the other side substation through communication. The digital fault locator includes MPU module, ADPU module, SIU module, and a power module. The MMI firmware and software of the fault locator was implemented.

A Study on the Wireless Power Transfer System using Magnetic Resonance at the 1[MHz] Frequency Band (1[MHz] 대역의 자계 공명을 이용한 무선 전력 전송 장치에 관한 연구)

  • Park, Jeong-Heum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.75-81
    • /
    • 2012
  • In this paper, the wireless power transfer system using the magnetic resonance was designed, analyzed by circuit analysis methode and the calculated transfer function was compared with the measured one. The self-resonant coil was made up of the commonly used capacitor which had the lumped capacitance and it enabled the stable magnetic resonance not to be affected by the circumstance. The transmission efficiency of this system was 70[%] at the 15[cm] between the transmission and receiving coil and the measured transfer function was similar to the calculated one, which means the circuit analysis methode is valid in this system. When the intermediate coils were added between the transmission and receiving coil, the transmission efficiency was increased, which produced the increase of transfer distance. In the case of the five intermediate coils adding, the 35[%] transmission efficiency was achived at the 90[cm] distance.

Implementation and Performance Analysis of DGPS & RTK Error Correction Data Real-Time Transmission System for Long-Distance in Mobile Environments

  • Cho, Ik-Sung;Ha, Chang-Seung;Yim, Jae-Hong
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.291-291
    • /
    • 2002
  • DGPS(Differential Global Positioning System) and RTK(RealTime Kinematic) is in one of today's most widely used surveying techniques. But It's use is restricted by the distance between reference station and rover station and it is difficult to process data in realtime by it's own orgnizational limitation in precise measurement of positioning. To meet these new demands, In This paper, new DGPS and RTK correction data services through Internet and PSTN(Public Switched Telephony Network) have been proposed. For this purpose, we implemented performance a DGPS and RTK error correction data transmission system for long-distance using the internet and PSTN network which allows a mobile user to increase the distance at which the rover receiver is located from the reference in realtime. and we analyzed and compared DGPS and RTK performance by experiments through the Internet and PSTN network with the distance and the time.

  • PDF

Development of Low Cost Flight Test Equipment by Using Bang-pai Kite (방패연을 이용한 저비용 비행시험장치 개발)

  • Park, Jongseo;Kim, Bonggyun;Lee, Sangchul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.25 no.3
    • /
    • pp.68-73
    • /
    • 2017
  • In this study, we design a low-cost test equipment for real-time image observation and transmission/reception distance test using 1m by 1.5m bang-pai kite. The image observation is made by using two servo motors to enable the camera to control the two axis attitude. The image observation equipment is hung on the string of a kite and the test is performed to observe the real time image. The transmission and reception distance test of the wireless RF transceiver module is conducted on the ground and in the air.

Protective Management System followed Distance Relay characteristics for Transmission Line with the Unified Power Flow Controller (UPFC연계시 거리계전기 동작특성에 따른 보호 관리 시스템)

  • Suh, Jung-Nam;Jung, Chang-Ho;Cho, Jong-Man;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.296-298
    • /
    • 2001
  • This paper represents protective management system for transmission line involving the UPFC(Unified Power Flow Controller) device, which is the most vigorous component of FACTS. The presence of the UPFC significantly affects the line parameters of transmission system, which are also influenced by the distance relay setting. Moreover, depending on the UPFC location and its parameters, zones of setting the distance relay will be changed. Therefore, established protective system should be taken into account the variable injected voltage of the UPFC and constructed data base system.

  • PDF

Development of An Expert System to Decide the Resetting Area of Protective Distance Relay in Power Transmission Systems (송전계통 보호 거리계전기 재정정 영역 판정 전문가시스템 개발)

  • 최면송;민병운;김기화;현승호;이승재
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.8
    • /
    • pp.437-443
    • /
    • 2003
  • In this paper an expert system is developed to decide the resetting area of protective devices in power transmission systems. A configuration change in power transmission networks from a substation extension such as new line or bus addition need resetting of protective devices around the point of configuration changes. To find the resetting area in complex power system is very difficult, especially when the distance protective relays are considered to be reset. The proposed expert system, in this paper to find the resetting area has many rules based on the changes of fault currents and apparent factors from the power system alteration. It solves the problem to find relay resetting area using the network information in the database and the rule-base. The case study shows a result of the problem to find relay resetting area in KEPCO system when there is any configuration change.

Strong Connection Clustering Scheme for Shortest Distance Multi-hop Transmission in Mobile Sensor Networks (모바일 센서 네트워크에서 최단거리 멀티홉 전송을 위한 강한연결 클러스터 기법)

  • Wu, Mary
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.6
    • /
    • pp.667-677
    • /
    • 2018
  • Since sensor networks consist of sensor nodes with limited energy resources, so efficient energy use of sensor nodes is very important in the design of sensor networks. Sensor nodes consume a lot of energy for data transmission. Clustering technique is used to efficiently use energy in data transmission. Recently, mobile sink techniques have been proposed to reduce the energy load concentrated on the cluster header near a sink node. The CMS(Cluster-based Mobile sink) technique minimizes the generation of control messages by creating a data transmission path while creating clusters, and supports the inter-cluster one-hop transmission. But, there is a case where there is no connectivity between neighbor clusters, it causes a problem of having a long hop data transmission path regardless of local distance. In this paper, we propose a SCBC(Strong connection balancing cluster) to support the path of the minimum number of hops. The proposed scheme minimizes the number of hops in the data transmission path and supports efficient use of energy in the cluster header. This also minimizes a number of hops in data transmission paths even when the sink moves and establishes a new path, and it supports the effect of extending the life cycle of the entire sensor network.