• 제목/요약/키워드: transient wear

검색결과 20건 처리시간 0.023초

Tribology of Si incorporated Diamond-like Carbon Films

  • Kim, Myoung-Geun;Lee, Kwang-Rveol;Eun, Kwang-Yong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1998년도 제14회 학술발표회 논문개요집
    • /
    • pp.44-44
    • /
    • 1998
  • It was observed that the friction coefficient decreased with increasing Si concentration in the l ilms. Furthermore, the friction behavior became more s때ble even when very small amount of S Si of less than 0.5 at. % was incorporatA:회 By analyzing the composition of the debris f formed, we could show that the low and stabilized friction coefficient is in마nately relatA:었 w with the formation of the Si rich oxide debris. These result supports the mechanism that the h hydrated silica debris is the reason for low friction coefficient in humid environment. Second e evidence of the role of Si rich oxide debris could be found in the triOO-chemical reactions d during initial stage of triho-test. When the Si concen$\sigma$ation was less than 5 at.%, initial t transient period of high friction coefficient was commonly observed. Mter the transient period, m the friction coefficient becomes lower with increasing contact cycles. The initial $\sigma$ansient p peri여 becomes shorter and the starting and maximum friction coefficients in $\sigma$ansient 야,riod d decreased with increasing Si concentration. Composition of the debris on the wear scar s surface was analyzed by Auger spe따'Oscopy at v뼈ous stages in the initial transient period. W We observed that when the friction coefficient increased in earlier stage of the $\sigma$'ansient p period, iron and oxygen was observed in the debris. However, decrease in the 당iction c coefficient in the later stage of the transient period was associated with the formation of s silicon rich oxide debris. This result also supports the friction mechanism of Si-DLC films t that the formation of Si rich oxide debris results in low friction coefficient in ambient a atmosphere. atmosphere.

  • PDF

PLC와 인버터의 동시 제어를 통한 기계식 주차설비의 과도 상태 성능 향상 (Improved transient performance of mechanical parking facilities through simultaneous PLC and inverter control)

  • 김창영;이교범
    • 전기전자학회논문지
    • /
    • 제25권1호
    • /
    • pp.116-127
    • /
    • 2021
  • 본 논문에서는 과도 상태 성능 향상이 있는 PLC와 인버터의 동시 제어기법을 제안한다. 기존 기계식 주차설비에서는 PLC만을 활용한 제어 방식이어서 유도전동기에 과전류를 발생시킬 확률이 높고, 브레이크 패드에 마찰로 인한 마모와 손상으로 승차감이 낮아지고, 수명이 단축된다. 이를 개선하기 위해서 PLC와 인버터의 동시 제어를 통한 제어 기법을 적용한 경우 유도전동기에 과전류를 방지하며 브레이크 패드를 보호하고, 승차감 향상, 제어성 상승과 안전성을 확보한다. 제안한 PLC와 인버터의 동시 제어를 통한 제어 방식을 기계식 주차설비에 적용하여 그 타당성을 검증한다.

Study on transient performance of tilting-pad thrust bearings in nuclear pump considering fluid-structure interaction

  • Qiang Li;Bin Li;Xiuwei Li;Quntao Xie;Qinglei Liu;Weiwei Xu
    • Nuclear Engineering and Technology
    • /
    • 제55권6호
    • /
    • pp.2325-2334
    • /
    • 2023
  • To study the lubrication performance of tilting-pad thrust bearing (TPTBs) during start-up in nuclear pump, a hydrodynamic lubrication model of TPTBs was established based on the computational fluid dynamics (CFD) method and the fluid-structure interaction (FSI) technique. Further, a mesh motion algorithm for the transient calculation of thrust bearings was developed based on the user defined function (UDF). The result demonstrated that minimum film thickness increases first and then decreases with the rotational speed under start-up condition. The influence of pad tilt on minimum film thickness is greater than that of collar movement at low speed, and the establishment of dynamic pressure mainly depends on pad tilt and minimum film thickness increases. As the increase of rotational speed, the influence of pad tilt was abated, where the influence of the moving of the collar dominated gradually, and minimum film thickness decreases. For TPTBs, the circumferential angle of the pad is always greater than the radial angle. When the rotational speed is constant, the change rate of radial angle is greater than that of circumferential angle with the increase of loading forces. This study can provide reference for improving bearing wear resistance.

Coupled temperature-displacement modeling to study the thermo-elastic instability in disc brakes

  • Ramkumar, E.;Mayuram, M.M.
    • Coupled systems mechanics
    • /
    • 제1권2호
    • /
    • pp.165-182
    • /
    • 2012
  • Macroscopic hot spots formed due to the large thermal gradients at the surface of the disc brake rotor, make the rotor to fail or wear out early. Thermo-elastic deformation results in contact concentration, leading to the non uniform distribution of temperature making the disc susceptible to hot spot formation. The formation of one hot spot event will predispose the system to future hot spotting at the same location. This leads to the complete thermo-elastic instability in the disc brakes; multitude parameters are responsible for the thermo elastic instability. The predominant factor is the sliding velocity and above a certain sliding velocity the instability of the brake system occurs and hot spots is formed in the surface of the disc brake. Commercial finite element package ABAQUS(R) is used to find the temperature distribution and the result is validated using Rowson's analytical model. A coupled analysis methodology is evolved for the automotive disc brake from the transient thermo-elastic contact analysis. Temperature variation is studied under different sliding speeds within the operation range.

부분 모델을 이용한 접촉하중을 받는 코팅층이 있는 부재의 열적/기계적 응력해석 (Thermo-Mechanica1 Stress Analyses of Part with Coated Layer under Contact Load Using Partial Model)

  • 권영두;김석삼;신세현;추상우
    • Tribology and Lubricants
    • /
    • 제18권3호
    • /
    • pp.228-234
    • /
    • 2002
  • Generally, space structures are subjected to severe situations, such as, sublimation, strong evaporation of lubricants, thermal stresses, high temperature gradients, irradiation, impacts by microscopic meteorites, and other factors. Recent]y, various kinds of coatings are applied to the parts under heavy contact stresses, in order to insure long wear-free lives and/or reduce friction coefficients. In space structures, molybdenum disulfide is using frequently. Moreover TiN, Al$_2$O$_3$, PTFE(Poly Tetra Fluor Ethylene) are introduced recently for space structure. In this part we are going to apply the partial model method, developed in reference[11] to analyze part with coated layer. In referencer[l1], we compute the reasonable size of partial model and aspect ratio. Using these data, we analyze the structures coated with TiN, Al$_2$O$_3$, PTFE under contact load, temperature and crack model . Beside, we consider the stress analysis under time dependent load and transient thermal effect.

철도용 전기기기의 고장요인 및 절연열화 분석 (Analysis of faust cause & insulation degradation on the electrical equipments for railway)

  • 왕종배;전한준;박옥정;온정근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.207-210
    • /
    • 2001
  • Electrical equipment for railway is always experiencing wear and degradation by mechanical, electrical and environmental stress in service and the fault or the accident of high voltage main circuit directly causes operation interruption. Particularly propulsion drive of high speed switching inverter takes the form of specific degradation mechanism such as fast rising transient surge, reflective overvoltage and harmonic stress, and it is known that it threatens the long life and the reliability of electrical equipment. In this paper, statistics of fault and accident on main electrical equipment for railway are presented and also insulation degradation mechanism, which governs end life of electrical device, is analyzed. Finally the method of fault respondence and reliability improvement on the main electrical equipments will be reviewed in order to prevent operation interruption.

  • PDF

내마모 철계 소결합금(Fe-5Cr-lMo-2Cu-0.5P-3C)에서 정합변형이 액상석출물의 모양에 미치는 영향 (The Effect of Elastic Anisotropy on the Shape of a Liquid Precipitate in a Wear-Resistant Fe-Base Alloy(Fe-5Cr- lMo-2Cu-0.5P-3C))

  • 신형상
    • 한국분말재료학회지
    • /
    • 제1권1호
    • /
    • pp.60-65
    • /
    • 1994
  • When a commercial prealloyed Fe-powder(Fe-5Cr-lMo-2Cu-0.5P-3C) is liquid phase sintered at 116$0^{\circ}C$, liquid precipitates with various shapes form within solid grains during the initial stage of sintering. The shape of a liquid precipitate changes pith the increment of their size from sphere(with radius<0.3$\mu\textrm{m}$), a transient polyhedron with more than 7 faces(1~2 $\mu\textrm{m}$), cuboid(3~5 $\mu\textrm{m}$), and finally to sphere(>5 $\mu\textrm{m}$). The shapes of liquid precipitates closely resemble the growth shapes predicted on the basis of solid-liquid interfacial energy and the coherency strain energy with anisotropic elastic constants in the diffusion zone around the precipitates.

  • PDF

핀부시 베어링 소재의 계면접합특성에 관한 실험적 연구 (Experimental Study on the Interface Bonding Characteristics of a Pin-bushing Bearing)

  • 김청균;김도현
    • Tribology and Lubricants
    • /
    • 제24권6호
    • /
    • pp.315-319
    • /
    • 2008
  • This paper presents the interface bonding characteristics between a phosphor bronze and a steel plate for pin-bush bearings. The pin-bush bearing is an important component in which is used to reduce a friction loss and a wear against the piston pin. The pin-bush bearing is manufactured by hot-pressing a phosphor bronze and a back metal of a steel plate. This paper investigated the bonding interface characteristics in which is manufactured by melting a copper based bronze and a steel plate. The hardness from the inner surface of a bronze to the outer one of steel has been measured using a Vickers hardness tester. The experimental results show that the hardness of a bronze is superior to that of the conventional bronze and the transient hardness of pin-bush bearings is gradually increasing to the hardness of the steel back metal. This means that the bonding interface zone of pin-bush bearings may be fabricated by defusing a bronze to the steel plate due to a density difference between two materials.

FLUID-STRUCTURE INTERACTION IN A U-TUBE WITH SURFACE ROUGHNESS AND PRESSURE DROP

  • Gim, Gyun-Ho;Chang, Se-Myoung;Lee, Sinyoung;Jang, Gangwon
    • Nuclear Engineering and Technology
    • /
    • 제46권5호
    • /
    • pp.633-640
    • /
    • 2014
  • In this research, the surface roughness affecting the pressure drop in a pipe used as the steam generator of a PWR was studied. Based on the CFD (Computational Fluid Dynamics) technique using a commercial code named ANSYS-FLUENT, a straight pipe was modeled to obtain the Darcy frictional coefficient, changed with a range of various surface roughness ratios as well as Reynolds numbers. The result is validated by the comparison with a Moody chart to set the appropriate size of grids at the wall for the correct consideration of surface roughness. The pressure drop in a full-scale U-shaped pipe is measured with the same code, correlated with the surface roughness ratio. In the next stage, we studied a reduced scale model of a U-shaped heat pipe with experiment and analysis of the investigation into fluid-structure interaction (FSI). The material of the pipe was cut from the real heat pipe of a material named Inconel 690 alloy, now used in steam generators. The accelerations at the fixed stations on the outer surface of the pipe model are measured in the series of time history, and Fourier transformed to the frequency domain. The natural frequency of three leading modes were traced from the FFT data, and compared with the result of a numerical analysis for unsteady, incompressible flow. The corresponding mode shapes and maximum displacement are obtained numerically from the FSI simulation with the coupling of the commercial codes, ANSYS-FLUENT and TRANSIENT_STRUCTURAL. The primary frequencies for the model system consist of three parts: structural vibration, BPF(blade pass frequency) of pump, and fluid-structure interaction.

Short- to mid-term outcomes of radial head replacement for complex radial head fractures

  • Baek, Chung-Sin;Kim, Beom-Soo;Kim, Du-Han;Cho, Chul-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • 제23권4호
    • /
    • pp.183-189
    • /
    • 2020
  • Background: The purpose of the current study was to investigate short- to mid-term outcomes and complications following radial head replacement (RHR) for complex radial head fractures and to identify factors associated with clinical outcomes. Methods: Twenty-four patients with complex radial head fractures were treated by RHR. The mean age of the patients was 49.8 years (range, 19-73 years). Clinical and radiographic outcomes were evaluated for a mean follow-up period of 58.9 months (range, 27-163 months) using the visual analog scale (VAS) score for pain, the Mayo elbow performance score (MEPS), the quick disabilities of the arm, shoulder and hand (Quick-DASH) score, and serial plain radiographs. Complications were also evaluated. Results: At the final follow-up, the mean VAS score, MEPS, and Quick-DASH score were 0.6±1.1, 88.7±11.5, and 19.4±7.8, respectively. The mean range of motion was 132.7° of flexion, 4.7° of extension, 76.2° of pronation, and 77.5° of supination. Periprosthetic lucency was observed in six patients (25%). Heterotopic ossification was observed in four patients (16.7%). Arthritic change of the elbow joint developed in seven patients (29.2%). Capitellar wear was found in five patients (20.8%). Arthritic change of the elbow joint was significantly correlated with MEPS (P=0.047). Four cases of complications (16.6%) were observed, including two cases of major complications (one stiffness with heterotopic ossification and progressive ulnar neuropathy and one stiffness) and two cases of minor complications (two transient ulnar neuropathy). Conclusions: RHR for the treatment of complex radial head fractures yielded satisfactory short- to mid-term clinical outcomes, though radiographic complications were relatively high.