• 제목/요약/키워드: transient vibration

검색결과 408건 처리시간 0.026초

병진 또는 회전하여 위치 이동하는 유연 외팔보의 잔류진동 저감을 위한 최적 명령 입력 및 입력 다듬기 방법과의 비교 (Optimal Command Input for Suppressing the Residual Vibrations of a Flexible Cantilever Beam Subjected to a Transient Translation or Rotation Motion and Its Comparison with the Input Shaping Method)

  • 신기홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.589-594
    • /
    • 2007
  • In this paper, the optimal command input is considered in order to minimize the residual vibrations of a flexible cantilever beam when the beam simply changes its position by translation or rotation. Although a cantilever beam has many modes of vibration, it is shown that the consideration of the first mode is sufficient in this case. Thus, the problem becomes a singledegree-of-freedom system subjected to a ground excitation. Two simple methods are proposed to find the optimal command input based on the Shock Response Spectrum (SRS). The first method is the simplest and can be applied to lightly damped cases, and the second method is applicable to more general problems. The second method gives almost the same results as the input shaping method. However the proposed method gives a easier and clearer control strategy.

  • PDF

지중발파에 의한 건물의 진동 거동에 관한 연구 (A Study on the Vibration Behavior of Building Structures due to Undergroud Blasting)

  • 조병윤;문형구
    • 터널과지하공간
    • /
    • 제6권2호
    • /
    • pp.157-165
    • /
    • 1996
  • In order to analyze the effects of ground vibration caused by underground blasting having an effect on structure, the particle velocity and acceleration are calculated by using DYNPAK program. The DYNPAK program analyzes nonlinear transient dynamic problem and adopts the very popular and easily implemented, explicit, central difference scheme. In this program, the material behavior is assumed to be elasto-viscoplastic. Using the particle acceleration history, modal analysis method is applied to the forced vibration response of multiple-degree-of-freedom(MDOF) systems using unclupled equations of motion expressed in terms of the system's natural circular frequencies and modal damping factors. AS a means of evaluating the vibration behavior of building structure subjected to underground blasting, the time response of the displacements relative to the ground of five-story building is determined. It is concluded that the amount of explosives consumed per round, the location of structure, the properties of rock medium, the stiffness fo structure, etc. act on the important factors influencing on the safety of building and that the response of a structure subjected to a forced excitation can usually be obtained with reasonable accuracy by the modal analysis of only a few mode of the lower frequencies of the system.

  • PDF

PEEK 와셔를 적용한 충격저감장치의 파이로 충격 및 진동 특성 (Pyroshock and Vibration Characteristics of PEEK Washer Shock Absorbers)

  • 윤세현;장영순;한재홍
    • 한국항공우주학회지
    • /
    • 제36권3호
    • /
    • pp.285-290
    • /
    • 2008
  • 파이로 충격은 고주파 영역까지 큰 가속도가 유발되는 천이 진동 현상으로 발사체에서는 주로 화약에 의한 분리 장치의 작동에 의해 발생하게 된다. 일반적인 발사체의 경우 단 분리, 페어링 분리, 위성 분리 이벤트에서 파이로 충격이 발생하게 되는데 이에 의해 위성 또는 발사체의 전자 장비가 비정상적인 기능을 보이거나 작동 불능 상태가 될 수 있다. 본 논문에서는 이러한 파이로 충격의 특성을 소개하고 PEEK 와셔를 적용한 충격저감장치를 실제 전자 장비에 적용하여 그 효과를 살펴보았다. 충격저감장치의 적용에 의해 고주파 영역에서의 충격 저감 효과가 있음을 확인하였고 저주파에서의 진동 특성에는 영향을 끼치지 않음을 시험을 통해 검증하였다.

ER 유체를 이용한 반능동 완충장치의 동적 특성 (Dynamic Characteristics of Semi-Active Shock Absorber Using Electrorheological Fluid)

  • 김도형;조기대;정용현;이인
    • 한국소음진동공학회논문집
    • /
    • 제11권4호
    • /
    • pp.13-21
    • /
    • 2001
  • Electrorheological(ER) fluid is a kind of smart material with variable shear stress and dynamic viscosity under various electric field intensity. Electric field can control the damping characteristics of ER damper. The objective of this study is the analysis of the performance of ER damper and its application to shock absorber. Idealized nonlinear Bingham plastic shear flow model is used to predict the velocity profile between electrodes. Cylindrical dashpot ER damper with moving electrode is constructed and tested under various electric fields. The analytic and experimental results for damping force are compared and discussed. Drop test system using ER damper is prepared to identify transient vibration characteristics. The rebound is eased as the applied electric field increases. When semi-active control algorithm is applied, rebound phenomenon disappears and vibration energy level decays faster than the case of zero electric field.

  • PDF

전력용변압기의 구조진동해석 및 능동소음제어 (Structure Vibration Analysis and Active Noise Control of Power Transformer)

  • 정윤미;최은지;김영달
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1771-1776
    • /
    • 2013
  • Most cases of power transformer failure are caused by physical factors linked to the transient vibrations of multiple 120Hz combinations. In addition, the noise generated in the transformer from this vibration not only directly contributes to the worsening of the work environment but also causes psychological stress, resulting in the worsening of the workers efficiency and of the living environment of the inhabitants around the power plant. Thus, to remedy these problems, the mechanical-excitation forces working on a power transformer were categorized in this study, and the mechanical-damage mechanism was identified through the vibration transfer paths acting on machines or structures. In addition, a study on active noise cancellation in a transformer using the FXLMS algorithm was conducted to develop a system that is capable of multiple-sound/channel control, which resulted in the active noise reduction effect when applied on the field.

파워스펙트럼 및 신경망회로를 이용한 기어박스의 결함진단 및 결함형태 분류에 관한 연구 (Fault Detection and Damage Pattern Analysis of a Gearbox Using the Power Spectra Density and Artificial Neural Network)

  • 이상권
    • 대한기계학회논문집A
    • /
    • 제27권4호
    • /
    • pp.537-543
    • /
    • 2003
  • Transient vibration generated by developing localized fault in gear can be used as indicators in gear fault detection. This vibration signal suffers from the background noise such as gear meshing frequency and its harmonics and broadband noise. Thus in order to extract the information about the only gear fault from the raw vibration signal measured on the gearbox this signal is processed to reduce the background noise with many kinds of signal-processing tools. However, these signal-processing tools are often very complex and time waste. Thus. in this paper. we propose a novel approach detecting the damage of gearbox and analyzing its pattern using the raw vibration signal. In order to do this, the residual signal. which consists of the sideband components of the gear meshing frequent) and its harmonics frequencies, is extracted from the raw signal by the power spectral density (PSD) to obtain the information about the fault and is used as the input data of the artificial neural network (ANN) for analysis of the pattern of gear fault. This novel approach has been very successfully applied to the damage analysis of a laboratory gearbox.

능동진동제어를 이용한 유연보의 끝단위치 명령추종연구 (Tip Position Command Tracking of a Flexible Beam Using Active Vibration Control)

  • Lee, Young-Sup;Elliott, Stephen-J
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.643-648
    • /
    • 2003
  • The problem considered in this paper is that the tip position of a flexible cantilever beam is controlled to follow a command signal, using a pair of piezoelectric actuators at the clamped end. The beam is lightly damped and so the natural transient response is rather long, and also since the sensor and actuator are not collocated, the plant response is non-minimum phase. Two control strategies were investigated. The first involved conventional PID control in which the feedback gains were adjusted to give the fastest closed-loop response to a step input. The second control strategy was based on an internal model control (IMC) architecture. The control filter in the IMC controller was a digital FIR device designed to minimize the expectation of the mean square tracking error. The IMC controller designed fur the beam was found to have very much reduced settling times to a step input compared with those of the PID controller.

  • PDF

압전 작동기/감지기를 이용한 평판의 혼합형 능동 진동제어 기술 (Hybrid Technique for Active Vibration Control of Plate using Piezoceramic Actuators/Sensors)

  • 김영식;이철;김인수
    • 소음진동
    • /
    • 제10권6호
    • /
    • pp.1048-1058
    • /
    • 2000
  • 본 논문에서는 압전 세라믹 재료를 작동기 및 감지기로 이용한 사각 경계면이 고정된 얇은 사각평판의 능동 진동제어 방법을 제시한다. 실험 데이터에 기초한 다중 입출력계의 주파수영역 모델링방법을 이용하여 분포된 센서 및 구동기 특성이 포함된 구조물의 동적 특성이 규명된다. 제어기 구조로는 혼합형을 채택하고 되먹임 제어기는 LQG 제어기법에 의해 설계된다. 앞먹임 제어기는 다중 filtered-$x$ 최소자승오차법에 의해 적응되도록 한다. 진동제어에 대한 시뮬레이션 및 실험결과는 제안된 제어기법이 지속적 외란 및 과도적 외란에 효율적으로 적용될 수 있음을 보인다.

  • PDF

열차하중으로 인한 궤도-지반의 3D 진동평가 및 저감방법에 관한 연구 (A Study on 3D Evaluation and Reduction Method for Vibration of Track-Roadbed due to Railway Load)

  • 강보순
    • 한국철도학회논문집
    • /
    • 제14권1호
    • /
    • pp.39-48
    • /
    • 2011
  • 본 논문에서는 열차가 주행할 때 궤도를 통해 전달되는 진동크기가 구조물의 안전성뿐 만아니라 선로 인근주민, 가축 및 건물에게 미치는 영향을 최소화하기 위해 규정된 진동한계범위에 도달하는 가를 다양한 지반과 궤도구조물의 상호작용에 의한 3D 수치해석을 통해 정확히 예측하고 다양한 지반에 적절한 진동저감을 가져오는 궤도의 단면 및 형태를 결정하는 방법에도 이결과를 사전에 활용할 수 있도록 하였다. 예로서 열차운행으로 인해 발생되는 터널, 성토 및 교량 3종류의 서로 다른 시설물의 진동을 지반-구조물의 상호작용에 의한 3D수치해석을 통해 Spec과 비교분석하여 평가하였으며 주변 환경에 적합한 토층의 변화를 통해 진동저감방법의 한예를 수행하였다.

볼스크류 이송계의 진동 최소화를 위한 이송속도 최적화 (A Study on the Feed Rate Optimization of a Ball Screw Feed Drive System for Minimum Vibrations)

  • 최영휴;홍진현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.962-966
    • /
    • 2004
  • Ball screw feed drive systems have been broadly used in machine tools or precision automatic feed systems. Recently, modern machine tools require high speed and high precision and drive system to achieve high productivity. Unfortunately, a feed drive system, even though it was optimum designed, may experience severe transient vibrations during high-speed operation if its feed rate control is unsuitable. A rough feed rate curve having discontinuity in its acceleration profile causes a serious vibration problem in the feed slide system. This paper presents a feed rate optimization of a machine tool feed slide system, which is driven by a ball screw, for its minimum vibrations. Firstly, a 6-degree-of-freedom lumped parameter model was proposed for the vibration analysis of a ball screw driven machine tool feed drive system. Next, a feed rate optimization of the feed slide was carried out for minimum vibrations. The feed rate curve optimization strategy is to find out the most appropriate acceleration profile having finite jerk. Of course, the optimized feed rate should approximate to the desired one as possible. A genetic algorithm with variable penalty function was used in this feed rate optimization.

  • PDF