• Title/Summary/Keyword: transient signal

Search Result 507, Processing Time 0.029 seconds

A Study on the Development of a Transient Voltage Stocking Device for Signal and Telecommunication Lines (신호.통신회로용 과도전압 차단장치 개발에 관한 연구)

  • 송재용;이종혁;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.11a
    • /
    • pp.490-493
    • /
    • 1999
  • Due to the miniaturization of electrical components and assembles on signal and telecommunication circuits, transient overvoltages caused by switching operation or lightning surge has become more interesting concern to the field of electrical engineering. This paper describes the development of transient voltage blocking devices (TBDs) that can protect sensitive signal and telecommunication devices from overvoltages. Two kinds of TBDs are designed and tested by using a combination surge generator which can produce the standard impulse current of 8/20${\mu}$s 2.1kA according to the IEC 1000-4-5 standard. From the simulation and experimental reults, it is confirmed that the proposed TBD has an enough protection performance in low insertion loss and tight clamping voltage.

  • PDF

The Response of a Wide-Range Oxygen Sensor to the Flow of Misfired Gas and Its Application for the Misfire Detection (실화가스 흐름에 대한 광역 산소센서의 응답특성 및 이를 이용한 실화감지)

  • 정영교;최상민;배충식;명차리
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.2
    • /
    • pp.41-49
    • /
    • 2000
  • To understand the signal fluctuation of a wide-range oxygen sensor installed at the exhaust confluence point, when a misfiring is triggered in a cylinder, the steady state and the transient response characteristics of the sensor to the flow of the misfired gas were investigated quantitatively. It was recognized that the steady state output voltage of the sensor increased higher when it contacted the misfired gas even though the fueling condition was the same as the normal combustion case and this characteristic enabled the application of the wide-range oxygen sensor for the misfire detection. The transient response was compared at different engine speeds and it was found that the response speed increased with the engine speed. The signal fluctuation was also estimated quantitatively, using these steady state and transient response of the sensor, and the estimated signal showed satisfactory correlation with the measurements.

  • PDF

Fault Detection and Location using SWT on Underground Power Cable System (SWT를 이용한 지중송전계통의 고장검출 및 고장점 추정)

  • Jung, Chae-Kyun;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.51-53
    • /
    • 2004
  • In this paper, we are going to propose the new algorithms to detect, classify, discriminate the transient and the reflected signal from noise and thus discriminate the fault section and locale the fault accurately on underground power cable system. Actually, at this system, it's very difficult to discriminate the transient because of the reflected signal including many noises. Therefore, how to solve the noise interference is a big problem. In this paper, authors present a solution based on multiple scales correlation of the transient using stationary wavelet transform. It's simple, quick and straightforward. For applying all algorithms, we just use the signal captured in single end.

  • PDF

Investigation on propagation characteristics of AE signal with FEM (FEM을 이용한 음향신호의 전달특성에 관한 연구)

  • Seo, Pan-Seok;Koo, Kyung-Wan;Kim, Jong-Seok;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.274-277
    • /
    • 2001
  • This paper describes the simulation study. conducted on the propagation characteristics of AE signal. In the case of gas insulation, such as $SF_6$, the equipment is less affected by the environment condition than air insulation, because the component parts of equipment were placed in the enclosure, which is filled with compressed gas. But. when the breakdown in the electric insulation occurs. it takes much time and economical efforts to repair. Therefore it is very important to diagnose the equipment before the accident. And. in general. UHF and AE signal is the most common transducer to diagnose the state of the power equipment, so, in this investigation, we make a experimental apparatus with aluminum plate and transient analysis with ANSYS to observe the propagation characteristics of AE signal. Through the result of the analysis. we can make a further understanding on the propagation characteristics of AE signal, and get the fundamental skills for the GIS diagnosis.

  • PDF

Investigation on propagation characteristics of AE signal with FEM (FEM을 이용한 음향신호의 전달특성에 관한 연구)

  • 서판석;구경완;김종석;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.274-277
    • /
    • 2001
  • This paper describes the simulation study, conducted on the propagation characteristics of AE signal. In the case of gas insulation, such as SF6, the equipment is less affected by the environment condition than air insulation, because the component parts of equipment were placed in the enclosure, which is filled with compressed gas. But, when the breakdown in the electric insulation occurs, it takes much time and economical efforts to repair. Therefore it is very important to diagnose the equipment before the accident. And, in general, UHF and AE signal is the most common transducer to diagnose the state of the power equipment, so, in this investigation, we make a experimental apparatus with aluminum plate and transient analysis with ANSYS to observe the propagation characteristics of AE signal. Through the result of the analysis, we can make a further understanding on the propagation characteristics of AE signal, and get the fundamental skills for the GIS diagnosis.

  • PDF

Transient osteoporosis of the hip with a femoral neck fracture during follow-up: a case report

  • Yusuke Tabata;Shuhei Matsui;Masabumi Miyamoto;Koichiro Omori;Yoichiro Tabata;Tokifumi Majima
    • Journal of Yeungnam Medical Science
    • /
    • v.40 no.2
    • /
    • pp.212-217
    • /
    • 2023
  • We report a case of transient osteoporosis of the hip with a femoral neck fracture found during follow-up. A 53-year-old man presented with left hip pain without trauma. The pain did not improve after 2 weeks and he was brought to our hospital by ambulance. Magnetic resonance imaging (MRI) of the left hip joint showed diffuse edema in the bone marrow, which was identified by low signal intensity on T1-weighted images, high signal intensity on T2-weighted images, and increased signal intensity on short tau inversion recovery. This edema extended from the femoral head and neck to the intertrochanteric area. He was diagnosed with transient osteoporosis of the left hip. Rest gradually improved his pain; however, 3 weeks later, his left hip pain worsened without trauma. X-ray, computed tomography, and MRI results of the hip joint demonstrated a left femoral neck fracture, and osteosynthesis was performed. Differential diagnoses included avascular necrosis of the femoral head, infection, complex regional pain syndrome, rheumatoid arthritis, leukemia, and other cancers. Transient osteoporosis of the hip generally has a good prognosis with spontaneous remission within a few months to 1 year. However, a sufficient length of follow-up from condition onset to full recovery is necessary to avoid all probable complications such as fractures.

Feature Extraction Algorithm for Underwater Transient Signal Using Cepstral Coefficients Based on Wavelet Packet (웨이브렛 패킷 기반 캡스트럼 계수를 이용한 수중 천이신호 특징 추출 알고리즘)

  • Kim, Juho;Paeng, Dong-Guk;Lee, Chong Hyun;Lee, Seung Woo
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.552-559
    • /
    • 2014
  • In general, the number of underwater transient signals is very limited for research on automatic recognition. Data-dependent feature extraction is one of the most effective methods in this case. Therefore, we suggest WPCC (Wavelet packet ceptsral coefficient) as a feature extraction method. A wavelet packet best tree for each data set is formed using an entropy-based cost function. Then, every terminal node of the best trees is counted to build a common wavelet best tree. It corresponds to flexible and non-uniform filter bank reflecting characteristics for the data set. A GMM (Gaussian mixture model) is used to classify five classes of underwater transient data sets. The error rate of the WPCC is compared using MFCC (Mel-frequency ceptsral coefficients). The error rates of WPCC-db20, db40, and MFCC are 0.4%, 0%, and 0.4%, respectively, when the training data consist of six out of the nine pieces of data in each class. However, WPCC-db20 and db40 show rates of 2.98% and 1.20%, respectively, while MFCC shows a rate of 7.14% when the training data consists of only three pieces. This shows that WPCC is less sensitive to the number of training data pieces than MFCC. Thus, it could be a more appropriate method for underwater transient recognition. These results may be helpful to develop an automatic recognition system for an underwater transient signal.

Shielding effect model and Signal Switching in the multi-layer interconnects (다층 배선에서 차폐효과 모델 및 스위칭에 미치는 영향)

  • 진우진;어영선
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.1145-1148
    • /
    • 1998
  • New capacitance modeling and transient analysis for multi-layer interconnects with shielding effect are presented. The upper layer capacitances with under-layer shielding lines are represented by introducing a filling factor η which can be defined as the ratio of upper-layer line length to the total under-layer line width. The upper-layer effective self capacitances considering two extreme cases which the underlayer metals are assumed as a ground or as a Vdd are modeled. The signal transient analysis with shielding effect model is performed.

  • PDF

Directional Harmonic Wavelet Analysis (방향성 조화 웨이블렛 해석 기법)

  • 한윤식;이종원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.267-272
    • /
    • 1998
  • A new signal processing technique, the directional harmonic wavelet map(dHWM), is presented to characterize the instantaneous planar motion of a measurement point in a structure from its transient complex-valued vibration signal. It is proven that the auto-dHWM essentially tracks the shape and directivity of the instantaneous planar motion, whereas the phase of the cross-dHWM indicates its inclination angle. Finally, the technique is successfully applied to an automobile engine for characterization of its transient motion during crank-on/idline/engine-off.

  • PDF

Development of Noise Cancellation Technique for Fault Location on Underground Power Cable System (지중송전계통 고장점 추정을 위한 노이지 제거 기법 개발)

  • Jung, Chae-Kyun;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.530-532
    • /
    • 2005
  • Actually, it's very difficult to discriminate the transient on underground power cable system because of the reflected signal including many noises. Therefore, in this paper, a solution based on multiple scales correlation of the transient using SWT(Stationary Wavelet Transform) is presented. It's quick and straightforward. For applying all algorithms, we just use the signal captured in single end.

  • PDF