• Title/Summary/Keyword: transient mixed flow

Search Result 17, Processing Time 0.025 seconds

Flow and Heat Transfer Analysis of Reactor Coolant Pump in Transient Conditions (원자로 냉각재 펌프의 과도 상태의 유동 및 열전달 해석 연구)

  • Hur, N.;Kim, S.;Yoo, K.-P.;Kim, S. T.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.245-251
    • /
    • 1999
  • The structural analysis of a reactor coolant pump(RCP) of a nuclear power plant is very important for the safety assessment of the plant. Accurate boundary conditions for the heat transfer coefficient are required for reliable thermal stress analysis of the pump casing, especially in transient operations of the pump since the coolant properties are largely dependent on operational conditions. In the present study, a 3D mixed flow type coolant pump was modeled from the RCP drawings and analyzed in the steady state and number of transient flow conditions by using a commercial code STAR-CD. From the result of the computation, it is seem that the average heat transfer coefficients for the cases considered are found to be the suggested values of the manufacturer, Westinghouse Energy System. The unevenness in local heat transfer coefficients, however, is found to be considerable so that the use of average heat transfer coefficients in all boundaries might not give reliable thermal stresses.

  • PDF

Flow and Heat Transfer Analysis of a Reactor Coolant Pump in Transient Conditions (원자로 냉각재 펌프의 과도 상태의 유동 및 열전달 해석 연구)

  • Hur, N.;Kim, S.;Yoo, K.-P.;Kim, S. T.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.2 s.7
    • /
    • pp.24-30
    • /
    • 2000
  • The structural analysis of a reactor coolant pump(RCP) of a nuclear power plant is very important for the safety assessment of the plant. Accurate boundary conditions for the heat transfer coefficient are required for reliable thermal stress analysis of the pump casing, especially in transient operations of the pump since the coolant properties are largely dependent on operational conditions. In the present study, a 3D mixed flow type coolant pump was modeled from the RCP drawings and analyzed in the steady state and number of transient flow conditions by using a commercial code STAR-CD. From the result of the computation, it is seen that the average heat transfer coefficients for the cases considered are found to be the suggested values of the manufacturer, Westinghouse Energy System. The unevenness in local heat transfer coefficients, however, is found to be considerable so that the use of average heat transfer coefficients in all boundaries might not give reliable thermal stress predictions.

  • PDF

Two Spool Mixed-Flow Turbofan Engine Performance Analysis Modeling (2 스풀 혼합흐름 배기방식 터보팬 엔진 성능해석 모델링)

  • Seungheon Lee;Hyoung Jin Lee;Sangjo Kim;Gyujin Na;Jung Hoe Kim
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.27 no.1
    • /
    • pp.37-48
    • /
    • 2023
  • In this study, performance analysis modeling of two spool mixed flow type turbofan engine according to steady-state and transient is performed. The target engine is selected as F100-PW-229 from Pratt & Whitney, and main engine components including fan, high pressure compressors, combustion, high pressure turbines, low pressure turbines, mixer, convergent-divergent nozzle are modeled. The cooling effect of turbine through secondary flow path are considered in engine simulation model. We develop in-house Matlab/Simulink-based engine performance analysis program capable of analyzing internal engine state and compare it with GASTURB which is generally used as a commercial engine analysis program.

Finite Element Analysis of Collapse of a Water Dam Using Filling Pattern Technique and Adaptive Grid Refinement of Triangular Elements (삼각형 요소의 형상 충전 및 격자 세분화를 이용한 붕괴하는 물 댐의 유한 요소 해석)

  • Kim, Ki-Don;Yang, Dong-Yol;Jeong, Jun-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.4
    • /
    • pp.395-405
    • /
    • 2004
  • The filling pattern and an adaptive grid refinement based on the finite element method and Eulerian mesh advancement approach have been developed to analyze incompressible transient viscous flow with free surfaces. The governing equation for flow analysis is Navier-Stokes equation including inertia and gravity effects. The mixed FE formulation and predictor-corrector method are used effectively for unsteady numerical simulation. The flow front surface and the volume inflow rate are calculated using the filling pattern technique to select an adequate pattern among four filling patterns at each triangular control volume. By adaptive grid refinement, the new flow field that renders better prediction in flow surface shape is generated and the velocity field at the flow front part is calculated more exactly. In this domain the elements in the surface region are made finer than those in the remaining regions for more efficient computation. Using the proposed numerical technique, the collapse of a water dam has been analyzed to predict flow phenomenon of fluid and the predicted front positions with respect to time have been compared with the reported experimental results.

Three Dimensional Finite Element Analysis of Free Surface Flow Using Filling Pattern Technique and Adaptive Grid Refinement (형상 충전 및 격자 세분화를 이용한 삼차원 자유 표면 유동의 유한 요소 해석)

  • Kim, Ki-Don;Yang, Dong-Yol;Jeong, Jun-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1348-1358
    • /
    • 2004
  • The filling pattern and an adaptive grid refinement based on the finite element method and Eulerian mesh advancement approach have been developed to analyze incompressible transient viscous flow with free surfaces. The governing equation fur flow analysis is Navier-Stokes equation including inertia and gravity effects. The mixed FE formulation and predictor-corrector method are used effectively for unsteady numerical simulation. The flow front surface and the volume inflow rate are calculated using the filling pattern technique to select an adequate pattern among seven filling patterns at each tetrahedral control volume. By adaptive grid refinement, the new flow field that renders better prediction in flow surface shape is generated and the velocity field at the flow front part is calculated more exactly. In this domain the elements in the surface region are made finer than those in the remaining regions for more efficient computation. The collapse of a water dam and the filling of a fluidity spiral have been analyzed. The numerical results have been in good agreement with the experimental results and the efficiency of the adaptive grid refinement and filling pattern techniques have been verified.

An Experimental Study of The J-T Cryocooler with Mixed Refrigerant (혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구)

  • 이경수;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF

Hybrid numerical scheme for transient mixed flow in pipe (관망내 안정적인 흐름해석을 위한 수치기법)

  • An, Hyunuk;Lee, Seungsoo;Kim, Yeonsu;Noh, Joonwo;Kim, Sunghoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.293-293
    • /
    • 2018
  • 관망내 흐름의 수치 모델링은 도시 침수 분석, 하수도 관의 손상 탐지 또는 하수도 시스템 설계와 같은 넓은 분야에 적용되는 매우 중요한 문제 중 하나이다. 관망내 흐름상태는 자유수표면이 존재하는 개수로 흐름과 자유수표면이 관내에 존재하지 않는 관수로 흐름, 그리고 개수로 흐름과 관수로 흐름의 경계지점에 혼합흐름상태가 존재한다. 개수로 흐름과 관수로 흐름의 해석을 위해서는 일반적으로 다른 지배방정식의 적용이 필요하며 이는 관망내 흐름해석을 어렵게 만드는 원인 중 하나가 된다. 이러한 어려움을 극복하기 위해서 관망의 흐름해석에는 일반적으로 Preissmann slot 모델이 널리 사용되고 있다. 그러나 그럼에도 불구하고, Preissmann slot 모델의 수치해석 시 수치진동으로 인한 수치적 불안정이 발생하기 쉬우며, 특히 개수로 흐름에서 관수로 흐름으로 넘어가는 혼합흐름상태에서 이러한 수치진동이 쉽게 발생하는 것으로 알려져 있다. 이러한 수치진동은 수치적 불안정성을 유발할 뿐만 아니라, 해의 정확성을 크게 저하시킬 수 있다. 본 연구에서는 이러한 문제를 극복하기 위해 Preissmann slot 모델의 새로운 수치기법을 제안하였다. Approximate Reimann flux solver와 Centred flux solver를 결합하여 하이브리드 해석기법을 개발하였다. 수지진동 발생하기 쉬운 실험들의 모의를 통하여 수치기법의 성능을 검증하였다.

  • PDF

The Study on the Dynamics and Friction Characteristics of Piston Skirt with Consideration of Mixed Lubrication

  • Kim, Ji-Young;Han, Dong-Chul;Cho, Myung-Rae;Choi, Jae-Kwon
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.735-742
    • /
    • 2001
  • This paper reports on the dynamics and friction characteristics of piston skirt with consideration of mixed lubrication. Piston skirt is an important part of the engine that transforms fuel into mechanical energy. The durability and low friction characteristics are important recent issues in piston skirt design. In this paper, the piston skirt motion is analyzed with consideration of mixed lubrication and piston skirt tilting motion. The entire trajectory of piston motion is obtained by using transient numerical method. Also various parameter studies are performed for piston skirt design and the development of lower frictional engine.

  • PDF

A Numerical Study on Transient Performance Behavior of a Turbofan Engine with Variable Inlet Guide Vane and Bleed Air Schedules (가변 입구 안내익과 블리드 공기 스케줄에 따른 터보팬 엔진에서의 천이 성능특성에 관한 수치연구)

  • Kim, Sangjo;Son, Changmin;Kim, Kuisoon;Kim, Myungho;Min, Seongki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.5
    • /
    • pp.52-61
    • /
    • 2015
  • This paper performed a numerical study to analyse the transient performance behavior of a turbofan engine with variable inlet guide vane (IGV) and bleed air schedules. The low bypass ratio mixed flow turbofan engine was considered in this study. For modeling the compressor performance with IGV, the performance maps were generated by using a one-dimensional meanline analysis and feed to the engine simulation program. The IGV and bleed air according to the rotating speed were scheduled to satisfy 10% of surge margin at steady-state condition. The transient engine performance analysis was conducted with the schedules. The engine with IGV schedule showed a higher surge margin and lower turbine inlet temperature than the engine with bleed air schedule during the transient period.

Control of oscillatory Czochralski convection by ACRT (ACRT에 의한 초크랄스키 대류진동 제어)

  • Choe, Jeong-Il;Seong, Hyeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.7
    • /
    • pp.2397-2408
    • /
    • 1996
  • A numerical study was made of the control of transient oscillatory flow modes in Czochralski convection. The reduction of temperature oscillation was achieved by changing the rotation rate of crystal rod, .OMEGA.$_{S}$=.OMEG $A_{S0}$(1+ $A_{S}$sin(2.pi. $f_{S}$/ $t_{p}$t)). The temporal behavior of oscillation flow was scrutinized over broad ranges of two parameters, i.e., the rotation amplitude( $A_{S}$.leq.0.5) and the nondimensional frequency (0.9.leq. $f_{S}$.leq.1.5). The mixed convection parameter was ranged 0.225.leq.Ra/PrR $e^{2}$.leq.0.929, which encompassed the buoyancy-and forced-dominant convection regimes. Computational results revealed that the temperature oscillations could be reduced effectively by a proper adjustment of the control parameters. The uniformity of temperature distribution near the crystal rod was examined. The control of oscillatory flow modes was also made for a realistic, low value of Pr.