• Title/Summary/Keyword: transient loads

Search Result 222, Processing Time 0.038 seconds

A Single-Input Single-Output Approach by using Minor-Loop Voltage Feedback Compensation with Modified SPWM Technique for Three-Phase AC-DC Buck Converter

  • Alias, Azrita;Rahim, Nasrudin Abd.;Hussain, Mohamed Azlan
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.829-840
    • /
    • 2013
  • The modified sinusoidal pulse-width modulation (SPWM) is one of the PWM techniques used in three-phase AC-DC buck converters. The modified SPWM works without the current sensor (the converter is current sensorless), improves production of sinusoidal AC current, enables obtainment of near-unity power factor, and controls output voltage through modulation gain (ranging from 0 to 1). The main problem of the modified SPWM is the huge starting current and voltage (during transient) that results from a large step change from the reference voltage. When the load changes, the output voltage significantly drops (through switching losses and non-ideal converter elements). The single-input single-output (SISO) approach with minor-loop voltage feedback controller presented here overcomes this problem. This approach is created on a theoretical linear model and verified by discrete-model simulation on MATLAB/Simulink. The capability and effectiveness of the SISO approach in compensating start-up current/voltage and in achieving zero steady-state error were tested for transient cases with step-changed load and step-changed reference voltage for linear and non-linear loads. Tests were done to analyze the transient performance against various controller gains. An experiment prototype was also developed for verification.

Development of Enhanced Contingency Screening and Selection Algorithm for On-line Transient Security Assessment (과도안전도 평가를 위한 개선된 상정고장 선택 및 여과 알고리즘 개발)

  • Kim Yong-Hak;Song Sung-Geun;Nam Hae-Kon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.6
    • /
    • pp.306-314
    • /
    • 2005
  • In this paper, a new approach that is based on EEAC & only with network solutions for CS&S in the transient stability assessment is developed. The proposed CS&S algorithm in conjunction with EEAC to include the capability of performing on-line TSA without TDS is used to calculate the critical clearing time for stability index. In this algorithm, all generators are represented by classical models and all loads are represented by constant impedance load models. The accelerating & synchronizing power coefficient as an index is determined at its disturbance through solving network equation directly. As mentioned above, a new index for generator is generally used to determine the critical generators group. The generator rotor angle is fixed for non-critical generators group, but has equal angle increments for critical generators group. Finally, the critical clearing time is calculated from the power-angle relationship of equivalent OMIB system. The proposed CS&S algorithm currently being implemented is applied to the KEPCO system. The CS&S result was remarkably similar to TSAT program and SIME. Therefore, it was found to be suitable for a fast & highly efficient CS&S algorithm in TSA. The time of CS&S for the 139 contingencies using proposed CS&S algorithm takes less than 3 seconds on Pentium 4, 3GHz Desktop.

Surge Characteristics Analysis of Three-phase Virtual Chopping at Vacuum Circuit Breaker (진공차단기 3상 동시 차단시의 서지 특성 분석)

  • Kim, Jong-Gyeum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.9
    • /
    • pp.1159-1164
    • /
    • 2018
  • Vacuum circuit breakers(VCB) are widely used for current interruption of high-voltage inductive loads such as induction motors. This VCB can be chopped off before the current zero due to its high arc-extinguishing capability. One of the outstanding features of VCB is that it can cut off high frequency re-ignition current more than other circuit breakers. If the transient recovery voltage generated in the arc extinguishing is higher than the dielectric strength of the circuit breaker, a re-ignition phenomenon occurs. The surge voltage of the re-ignition is very high in magnitude and the steepness of the waveform is so severe that it can act as a high electrical stress on the winding. If the high frequency current of one phase affects the other two phases when the re-ignition occurs, it may cause a high surge voltage due to the virtual current chopping. If the magnitude of the voltage allowed in the motor winding is high or the waveform level is too severe, it may lead to insulation breakdown. Therefore, it is necessary to reduce the voltage to within a certain range. In this study, we briefly explain the various phenomena at the time of interruption, analyzed the magnitude of the dielectric strength and the transient recovery voltage at the simultaneous three-phase interruption that can give the greatest influence to the inductive load, proposed a method to reduce the impact.

An improved adaptive control technique for the Voltage Bus Conditioner with parallel loads in the DC Power Distribution System (병렬 부하를 갖는 DC배전 시스템을 위한 Voltage Bus Conditioner의 향상된 적응제어)

  • Lee, Byung-Hun;Chang, Han-sol;La, Jae-Du;Kim, Young-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.249-250
    • /
    • 2011
  • In DC Power Distribution System(DC PDS), a bus voltage instability is occurred by multiple parallel loads. The Voltage Bus Conditioner(VBC) is used to mitigate the DC bus voltage transient. An adaptive controller of the VBC is designed and the simulation result of the controller is verified by PSIM simulation package for the proposed control technique.

  • PDF

The design of the Sliding Mode Controller of Voltage Bus Conditioner for a DC Power Distribution System with multiple parallel loads in the Electrical Vehicles (다중 병렬 부하를 갖는 전기 자동차의 DC 배전 시스템을 위한 Voltage Bus Conditioner의 슬라이딩 모드 제어기 설계)

  • Chang, Han-Sol;Jeon, Yong-Sung;La, Jae-Du;Kim, Young-Jo;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1141-1142
    • /
    • 2011
  • An electrical vehicle (EV) is a huge issue in the automotive industry. The EV have many electrical units: electric motors, batteries, converters, ets. The DC power distribution system (PDS) is essential for the EV. The DC PDS offers many advantages. However, multiple loads in the DC PDS may affect the severe instability on the DC bus voltage. Therefore, a voltage bus conditioner (VBC) may use the DC PDS. The VBC is used to mitigate the voltage transient on the bus. In this paper, sliding mode controller (SMC) is designed for the VBC of DC PDS in the EV. The simulation results by PISM simulation package are presented for validating the proposed control technique.

  • PDF

A Study on the strength evaluation for T-type Composite Beam (T형 합성보의 내력평가에 관한 연구)

  • Kim, Sang Mo;Kim, Kyu Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.4 s.65
    • /
    • pp.467-474
    • /
    • 2003
  • Composite action can be achieved by providing shear connectors between the steel top flange and concrete topping. Composite sections are stiffer than the sum of the individual stiffness of slab and beam. They can therefore carry heavier loads or similar loads with appreciably smaller deflection. They are also less prone to transient vibration. In this study, T-type Steel Composite beam (TSC-beam) was developed and tested. The test results of TSC beam were compared with the theoretical results based on composite actions.

The Influence of Inductive Loads on Power System Voltage Stabilization (유도부하가 전력 계통의 전압안정화에 미치는 영향)

  • Chung, Jai-Kil;Park, Sung-Dae;Cho, Yang-Haeng;Oh, Chang-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.35-37
    • /
    • 1993
  • This paper shows that the presence of constant impedance loads and induction motors in power system's loading contents can lead to transient voltage instabilities during normal system manipulations such as switchings. The abnormal induction motor characteristics during system transients which initiate the voltage instabilities are illustrated. The influence of motor and network parameters, such as motor inertia mechanical load quantity and nature on the severity of the voltage instability are studied.

  • PDF

EMTP Modeling and Dynamic Analysis of Microturbine Based Microsource for Application to Microgrid (마이크로그리드 적용을 위한 마이크로터빈 기반 마이크로소스의 EMTP 모델링과 동특성 시뮬레이션)

  • Jyung, Tae-Young;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.42-48
    • /
    • 2009
  • Microgrid supplies loads with power interconnected grid. And it is defined a independent power system compounded micro sources over two devices which have enough capacity to operate independently, storage devices and loads. The energy sources of micro source have different dynamic characteristics corresponding to classes and application skills. However their transient responses are various from a few seconds to minutes. Therefore it is limitation for understanding operation characteristics of microsource modeling constant voltage source or constant current source. This paper shows that we designed EMTP/RV model of micro source which is microturbine based energy source. And we performed dynamic analysis of micro source corresponding to operation mode of microgrid.

A Disturbance Observer-Based Robust Controller Against Load Variations in a Single Phase DC/AC Inverter System (단상 DC/AC 인버터 시스템의 부하변동을 고려한 외란 관측기 기반 제어기)

  • Kim, Sung-Jong;Son, Young-Ik;Jeong, Yu-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.110-112
    • /
    • 2007
  • Output voltage waves of a DC/AC inverter system are likely to be distorted if variable loads e.g. motors or rectifiers exist in the output terminal. This paper designs a disturbance observer-based PI controller for a single-phase inverter system that is robust against load changes. In this paper, we regard the output voltage changes due to various loads as disturbances of the control system, Then we design a disturbance observer for estimation of the disturbances caused by the load current and any other error sources (such as parameter uncertainties and model mismatches etc.). In order to test the performance of the proposed control law, simulation studies are carried out for a single-phase inverter system using SimPowerSystems of Matlab Simulink. Compared to a simple PI control, the disturbance observer-based controller shows enhanced performance in transient responses for step load changes.

  • PDF

A parametric study of indicial function models in bridge deck aeroelasticity

  • Borri, C.;Costa, C.
    • Wind and Structures
    • /
    • v.7 no.6
    • /
    • pp.405-420
    • /
    • 2004
  • In common approaches, bridge dynamics under wind action is analyzed by modeling the interaction between fluid and structure by means of transient wind loads acting over the structure itself. Amid various possible manners to describe such types of loads, a representation based on families of 'indicial functions' is adopted here. The aim is to investigate its flexibility to capture the main features of wind-bridge interaction. A set of coefficients is involved in indicial functions. The values that one may attribute to them suffer uncertainties coming from experimental errors affecting data. Here, the sensitivity of a 2-DOF schematic model to the variations of these coefficients is investigated at fixed values of dynamic derivatives and for various types of indicial functions. It is shown how parameter variations influence phase portraits.