• 제목/요약/키워드: transient improvement

검색결과 323건 처리시간 0.026초

Personal experience with microvascular decompression and partial sensory rhizotomy for trigeminal neuralgia

  • Lee, Jung Hwan;Lee, Jae Meen;Choi, Chang Hwa
    • Journal of Yeungnam Medical Science
    • /
    • 제38권3호
    • /
    • pp.202-207
    • /
    • 2021
  • Background: Trigeminal neuralgia (TN) is a severe, paroxysmal pain in the distribution of the fifth cranial nerve. Microvascular decompression (MVD) is the most widely used surgical treatment for TN. We undertook this study to analyze the effects of and complications of MVD and to refine the surgical procedure for treating TN. Methods: A total of 88 patients underwent for TN underwent surgery at our hospital. Among them, 77 patients underwent MVD alone, and 11 underwent partial sensory rhizotomy (PSR) with or without MVD. The medical records of these patients were retrospectively analyzed for patient characteristics, clinical results, offending vessels, and complications if any. Results: The mean follow-up duration was 43.2 months (range, 3-216 months). The most common site of pain was V2+V3 territory (n=27), followed by V2 (n=25) and V3 (n=23). The most common offending vessels were the superior cerebellar artery and anterior inferior cerebellar artery in that order. The overall rate of postoperative complications was 46.1%; however, most complications were transient. There were two cases of permanent partial hearing disturbance. In the MVD alone group, the cure rate was 67.5%, and the improvement rate was 26.0%. Among 11 patients who underwent PSR with or without MVD, the cure rate was 50.0%, and the improvement rate was 30.0%. Conclusion: The clinical results of MVD were satisfactory. Although the outcomes of PSR were not as favorable as those of pure MVD in this study, PSR can be considered in cases where there is no significant vascular compressive lesion or uncertainty of the causative vessel at the surgery.

디젤엔진 요소수 분사 SCR 시스템에서 촉매 내 암모니아 흡장량의 증가에 따른 NOx 저감효율 향상 특성에 관한 연구 (A Study on the Improvement of Diesel NOx Conversion Efficiency by Increasing the Ammonia Amount Adsorbed in a SCR Catalyst)

  • 김양화;임옥택;김홍석
    • 한국분무공학회지
    • /
    • 제25권4호
    • /
    • pp.196-203
    • /
    • 2020
  • Nowadays, urea SCR technology is considered as the most effective NOx reduction technology of diesel engine. However, low NOx conversion efficiency under low temperature conditions is one of its problems to be solved. This is because injection of UWS (Urea Water Solution) is impossible under such a low temperature condition due to the problem of insufficient of urea decomposition and urea deposits. In several previous studies, it has been reported that appropriate control of the amount of ammonia adsorbed on SCR catalyst can improve the NOx conversion efficiency under low temperature conditions. In this study, we tried to find out how much the NOx conversion efficiency increases with respect to the amount of ammonia adsorbed on the catalyst, and what the temperature conditions that the ammonia slip occurs. This study shows the results of 8 times repeated WHTC test with a diesel engine, in which UWS was injected with NH3/NOx mole ratio of '1'. Through this study, it was found that 13% of the NOx conversion efficiency of WHTC increased while the θ (ammonia adsorption rate) increased from "0%" to "22%". In addition, it is found that in cases of high θ value, the significant improvement of NOx conversion efficiency at low temperatures presented during the beginning period of WHTC and at high temperature and transient conditions presented during last part of WHTC test. The NH3 slip occurring condition was 250℃ of catalyst temperature and 10% of θ, and the amount of NH3 slip increased as the temperature and θ are increased.

Improvement of transmission-line-based fault locating for typical traveling-wave accelerator with constant-gradient structures

  • T.N. Hu;Y.F. Zeng;K. Peng;H. Hu;H.M. Wang;K.F. Liu
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2011-2018
    • /
    • 2024
  • Since RF breakdown is one of the primary limitations to improving the performances of RF accelerators, extensive efforts have been dedicated to locating the breakdowns. However, most existing methods rely on specialized techniques, resulting in high financial burdens. Although the method based on transient response of transmission line (TL) is suitable for facilities with sporadic recoverable breakdowns, practical operations are susceptible to notable errors. This study revisits the fundamental theories of lossless TL and investigates the wave process to understand the characteristics of the reversed pulse induced by the breakdowns. By utilizing steadystate response of the TL and employing phasor method, we derive analytical formulas to determine the exact location of breakdowns within the faulty cell for constant-gradient TW accelerator. Furthermore, the derived formulas demonstrate their independence from RF phase, thereby distinguishing them from traditional phasebased methods. Additionally, experimental validations are conducted at the HUST injector, and the results confirm the consistency of the analysis. Thus, the proposed method represents a promising improvement over the TL-based approaches and serves as a valuable complement to current techniques. Importantly, this method demonstrates particular advantages for constructed TW accelerators seeking to achieve a balance among high performance, low costs, and compact layouts.

Correlation between Epidurographic Contrast Flow Patterns and Clinical Effectiveness in Chronic Lumbar Discogenic Radicular Pain Treated with Epidural Steroid Injections Via Different Approaches

  • Gupta, Ruchi;Singh, Saru;Kaur, Sukhdeep;Singh, Kulvinder;Aujla, Kuljeet
    • The Korean Journal of Pain
    • /
    • 제27권4호
    • /
    • pp.353-359
    • /
    • 2014
  • Background: Epidural steroid injections are an accepted procedure for the conservative management of chronic backache caused by lumbar disc pathology. The purpose of this study was to evaluate the epidurographic findings for the midline, transforaminal and parasagittal approaches in lumbar epidural steroid injections, and correlating them with the clinical improvement. Methods: Sixty chronic lower back pain patients with unilateral radiculitis from a herniated/degenerated disc were enrolled. After screening the patients according to the exclusion criteria and randomly allocating them to 3 groups of 20 patients, fluoroscopic contrast enhanced epidural steroids were injected via midline (group 1), transforaminal (group 2) and parasagittal interlaminar (group 3) approaches at the level of the pathology. The fluoroscopic patterns of the three groups were studied and correlated with the clinical improvement measured by the VAS over the next 3 months; any incidences of complications were recorded. Results: The transforaminal group presented better results in terms of VAS reduction than the midline and parasagittal approach groups (P < 0.05). The epidurography showed a better ventral spread for both the transforaminal (P < 0.001) and the paramedian approaches (P < 0.05), as compared to the midline approach. The nerve root filling was greater in the transforaminal group (P < 0.001) than in the other two groups. The ventral spread of the contrast agent was associated with improvement in the VAS score and this difference was statistically significant in group 1 (P < 0.05), and highly significant in groups 2 and 3 (P < 0.001). In all the groups, any complications observed were transient and minor. Conclusions: The midline and paramedian approaches are technically easier and statistically comparable, but clinically less efficacious than the transforaminal approach. The incidence of ventral spread and nerve root delineation show a definite correlation with clinical improvement. However, an longer follow-up period is advisable for a better evaluation of the actual outcom.

The Design and Simulation of a Fuzzy Logic Sliding Mode Controller (FLSMC) and Application to an Uninterruptible Power System Control

  • Phakamach, Phongsak;Akkaraphong, Chumphol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.389-394
    • /
    • 2004
  • A Fuzzy Logic Sliding Mode Control or FLSMC for the uninterruptible power system (UPS) is presented, which is tracking a sinusoidal ac voltage with specified frequency and amplitude. The FLSMC algorithm combines feedforward strategy with the Variable Structure Control (VSC) or Sliding Mode Control (SMC) and fuzzy logic control. The control function is derived to guarantee the existence of a sliding mode. FLSMC has an advantage that the stability of FLSMC can be proved easily in terms of VSC. Furthermore, the rules of the proposed FLSMC are independent of the number of system state variables because the input of the suggested controller is fuzzy quantity sliding surface value. Hence the rules of the proposed FLSMC can be reduced. The simulation results illustrate that the purposed approach gives a significant improvement on the tracking performances. It has the small overshoot in the transient and the smaller chattering in the steady state than the conventional VSC. Moreover, its can achieve the requirements of robustness and can supply a high-quality voltage power source in the presence of plant parameter variations, external load disturbances and nonlinear dynamic interactions.

  • PDF

Research on the Power Sharing Control and Stability of VSGs

  • Xie, Dong;Zang, Da-Jin;Gao, Peng;Wang, Jun-Jia
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.542-550
    • /
    • 2017
  • Aiming at the deficiencies of power sharing control performances when a traditional droop control is adopted for microgrid inverters, this paper proposes a microgrid inverter power sharing control strategy based on a virtual synchronous generator. This control method simulates the electromechanical transient characteristics of a synchronous generator in a power system by an ontology algorithm and the control laws of a synchronous generator by control over the speed governor and excitation regulator. As a result, that the microgrid system is able to effectively retain the stability of the voltage and frequency, and the power sharing precision of the microgrid inverter is improved. Based on an analysis of stability of a microgrid system controlled by a virtual synchronous generator, design thoughts are provided for further improvement of the power sharing precision of inverters. The simulation results shows that when the virtual synchronous generator based control strategy was adopted, the power sharing performances of microgrid inverters are improved more obviously than those using the droop control strategy.

지중배전케이블의 허용전류용량 증대를 위한 적정 회선배치 및 관로 이격거리 분석 (Analysis on Proper Cable Arrangement and Duct Distance to Maximize Ampacity of Underground Distribution Cable)

  • 조아라;문원식;이승재;김재철
    • 조명전기설비학회논문지
    • /
    • 제30권2호
    • /
    • pp.57-64
    • /
    • 2016
  • Power demand has continuously increased with technological and economical development. The load density is also growing in the center of downtown area. In particular, underground facilities have been increased on the purpose of the prevention of urban disasters and pedestrian environment improvement. Based on this situation, the underground space in urban surroundings has gradually decreased because of the limited space. The ampacity of buried cables is affected by various factors such as cable size, soil thermal resistance, burial depth and filling material. The thermal capacity of the facilities is determined by the absorb heat surrounding the cable and the soil. The maximum operating temperature of cable is the highest temperature when the insulator of cable is not damaged in the case of high enough temperature. In this paper, the most effective cabling configuration is suggested using the duct array adjustment. It was also considered to increase the number of cable line. This underground distribution system was simulated by using ETAP(Electrical Transient Analysis Program).

혈중 아연 농도가 정상인 모유수유를 한 미숙아에서 보인 장병성 선단 피부염 1례 (A Case of Acrodermatitis Enteropathica with Normal Serum Zinc Level in a Breastfed Preterm Infant)

  • 백정현;박철;박규희;이정화;홍영숙;이주원;백유상;송해준;이장훈
    • Neonatal Medicine
    • /
    • 제18권2호
    • /
    • pp.383-386
    • /
    • 2011
  • Acrodermatitis enteropathica due to zinc deficiency is characterized by periorificial dermatitis, alopecia, and intractable diarrhea. Here we report a case of transient acrodermatitis enteropathica in a 2-month-old preterm infant, whose skin is erythematous, scaly, eczematous, with an eruption starting from the periorificial area. While her serum zinc level was normal at 118.2 ug/dL, the serum alkaline phosphatase level was low at 48 IU/L and the serum alkaline phosphatase level get increased concordant with clinical improvement after zinc supplementation. Hence, this case shows that the diagnosis of zinc deficiency can be aided with a low level of serum alkaline phoaphatase although serum zinc level is normal.

전기철도 차량 내 변압기의 여자돌입전류 저감에 관한 연구 (A Study on the Reduction of Onboard Transformer Inrush Current of Electric Railway)

  • 허재선;강병욱;신희상;김재철
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2125-2130
    • /
    • 2010
  • The neutral section on electric railway system is significant sector in order to prevent short circuit of two electric powers. However, while electric trains pass the neutral section, those speed is decreased and the accident of AC electric traction system and the electric train would be occurred. So the countermeasures are urgently needed. The automatic power switching technology system that is current being research and development is system to improve these problems. Because main object of this system is power change using static switch in the neutral section, it's expected to cause a variety of transients. Especially, onboard transformer inrush current for electric railway train can be occurred more than rated current according to switching time. Therefore, the analysis and improvement are needed to ensure the stability of this system. In this paper, we analyze the operating characteristics of the automatic power switching technology system. Especially, it reviews inrush current according to the closing phase angle. And we propose control plan of inrush current considering the case that voltage is maintained due to counter electromotive force and regenerative braking operation of electric railway train. Finally, the proposed control scheme was reviewed using the transient analysis program.

3상 PWM AC/AC Buck 컨버터를 사용한 3상 전압 위상천이기 (Three Phase Voltage Phase Shifter Using Three Phase PWM AC/AC Buck Converter)

  • 최남섭
    • 한국정보통신학회논문지
    • /
    • 제5권6호
    • /
    • pp.1116-1121
    • /
    • 2001
  • 전력의 흐름제어와 전원시스템의 과도안정성 개선을 위하여 전압의 위상을 제어할 필요성이 있는 경우가 있다. 이제까지 위상 천이기는 주로 상변압기와 사이리스터 탭변환기를 사용하여 구성하였는데, 이는 응답속응성이 느리고 제어안정성이 떨어지는 단점이 있다. 본 논문에서는 PWM AC/AC 컨버터를 사용한 3상 전압 위상천이기를 제안한다. 제안된 3상 전압 위상천이기는 PWM제어에 의하여 응답속응성이 우수하고 과도상태에서의 제어안정성을 개선시킬 수 있는 장점이 있다. 본 논문에서는 제안된 시스템의 회로구성, 동작원리와 특성 등을 설명하여 그 특징과 장단점을 나타내고, 이를 PSIM 컴퓨터 시뮬레이션을 통하여 동작과 해석의 타당성을 확인한다.

  • PDF