• 제목/요약/키워드: transient energy function

검색결과 107건 처리시간 0.042초

에너지함수법을 이용한 ATC 계산에 관한 연구 (A Study for ATC Computation Using an Energy Function Method)

  • 김양일;정성원;김재현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.465-466
    • /
    • 2007
  • Available transfer capability(ATC) quantifies the viable increase in real power transfer from one point to another in a power system. ATC calculation has predominantly focussed on steady-state viability. In many power systems, point-to-point transfer is not restricted by steady-state limits, but by undesirable dynamic behavior following large disturbance. In this paper, an energy function method for transient stability ATC computation is proposed, which utilizes a between the potential energy and energy function.

  • PDF

간헐디젤분무의 액적크기 및 속도의 공동확률밀도함수 (Joint probability density function of droplet sizes and velocities in a transient diesel spray)

  • 김종현;구자예;오두석
    • 대한기계학회논문집B
    • /
    • 제22권5호
    • /
    • pp.607-617
    • /
    • 1998
  • Comparisons of joint probability density distribution obtained from the raw data of measured droplet sizes and velocities in a transient diesel fuel spray with computed joint probability density function were made. Simultaneous droplet sizes and velocities were obtained using PDPA. Mathematical probability density functions which can fit the experimental distributions were extracted using the principle of maximum likelihood. Through the statistical process of functions, mean droplet diameters, non-dimensional mass, momentum and kinetic energy were estimated and compared with the experimental ones. A joint log-hyperbolic density function presents quite well the experimental joint density distribution which were extracted from experimental data.

위그너-빌 분포 함수 기반의 고유치 분해를 이용한 수중 천이 신호 식별 (Underwater Transient Signal Classification Using Eigen Decomposition Based on Wigner-Ville Distribution Function)

  • 배건성;황찬식;이형욱;임태균
    • 한국음향학회지
    • /
    • 제26권3호
    • /
    • pp.123-128
    • /
    • 2007
  • 본 논문에서는 수중 천이 신호에 대한 식별 알고리즘을 제안한다. 일반적으로 해양의 배경잡음은 스펙트럼 특성 및 에너지 변화가 적은 정재성을 갖는 반면에 천이 신호는 스펙트럼 및 에너지 변화가 큰 비정재성을 가진다. 따라서 수중 천이 신호 식별을 위하여 선행되어져야 하는 수중 천이 신호 탐지에서는 프레임 단위로 스펙트럼 변이와 에너지 변화를 이용한다. 제안한 수중 천이 신호 식별 알고리즘에서는 특징 벡터를 추출하기 위하여 위그너-빌 분포 함수를 기반으로 고유치 분해를 이용한다. 추출된 특징 벡터를 기반으로 탐지된 수중 천이 신호의 특징 벡터와 식별하고자 하는 데이터베이스에 있는 기준 신호의 특징 벡터와의 상관 값을 프레임 단위로 계산하고, 각 클래스별로 프레임 사상도를 산출하여 최대 값을 갖는 기준 신호로 탐지된 수중 천이 신호를 식별한다.

하이브리드 방법을 이용한 전력계통 안정도 해석 (Power System Stability Analysis Using a Hybrid Approach)

  • 서규석;박지호
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.21-25
    • /
    • 2010
  • This paper explains hybrid method that combines Time domain simulation technique with the direct method of Transient stability analysis. First, it calculate trajectory of real system by Time domain Simulation using OOP(Object Oriented Programming method) and evaluate Transient Energy Function to induce stability index to calculate Transient stability margin. Once the status of system(stable or unstable) has been identified, proper criteria are proposed to stop time-domain simulation to reduce CPU time.

지/단락실증시험에서 MW급 계통연계형 ESS 절연/보호시스템 성능 분석에 관한 연구 (Analysis on Insulation and Protection Characteristics of Grid Connected ESS in Ground/Short-Circuit Fault)

  • 김진태;이승용;박상진;차한주;김수열
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권2호
    • /
    • pp.119-122
    • /
    • 2020
  • With recent ESS (Energy Storage System) fire accident, the fault protection performance is becoming more important. However, there has never been any experiments with the protection performance on the faults in the ESS system level. In this study, the effect of AC ground fault and IGBT (Insulated Gate Bipolar mode Transistor) short-circuit failure on MW class ESS was performed experimentally for the first time in the world. First of all, the effect of the AC single line ground fault on battery was analyzed. Moreover, the transient voltage was investigated as a function of the battery capacity and the power level. Finally, the breaking capability and insulation performance of ESS were examined under PCS short-circuit fault condition. Through the tests, it was found that ESS protection system safely blocked the faulty current regardless of the faults, whereas the electronic parts such as IGBT and MC (Magnetic Contactor) were broken by the fault current. Also, the electrical breakdown in ESS resulted from the transient voltage during the protection process.

The development of high fidelity Steam Generator three dimensional thermal hydraulic coupling code: STAF-CT

  • Zhao, Xiaohan;Wang, Mingjun;Wu, Ge;Zhang, Jing;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • 제53권3호
    • /
    • pp.763-775
    • /
    • 2021
  • The thermal hydraulic performances of Steam Generator (SG) under both steady and transient operation conditions are of great importance for the safety and economy in nuclear power plants. In this paper, based on our self-developed SG thermal hydraulic analysis code STAF (Steam-generator Thermalhydraulic Analysis code based on Fluent), an improved new version STAF-CT (fully Coupling and Transient) is developed and introduced. Compared with original STAF, the new version code STAF-CT has two main functional improvements including "Transient" and "Fully Three Dimensional Coupling" features. In STAF-CT, a three dimensional energy transferring module is established which can achieve energy exchange computing function at the corresponding position between two sides of SG. The STAF-CT is validated against the international benchmark experiment data and the results show great agreement. Then the U-shaped SG in AP1000 nuclear power plant is modeled and simulated using STAF-CT. The results show that three dimensional flow fields in the primary side make significant effect on the energy source distribution between two sides. The development of code STAF-CT in this paper can provide an effective method for further SG high fidelity research in the nuclear reactor system.

여자기 제어 효과를 고려한 에너지함수 유도 및 적용가능성에 관한 기초 연구 (Derivation of the Energy Function Reflecting Exciter Control Effects)

  • 김구한;최병곤;박정도;문영현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.125-128
    • /
    • 2000
  • This paper presents an energy function which provides the direct relationships between the system stability and parameters of the exciter system. The energy function is derived from the energy conservation law by using the first motion integral. he time derivative does not absolutely satisfy the seminegativeness. However dE/dt usually has big negative value just after the fault clearing so that the energy is rapidly decreased. In this situation, the system state can be obviously confined in a stable region if the intial energy is less than the UEP energy. With these observation, two theorems are developed regarding the state confinement and asymptotic stability. Based on two theorems a new approximated direct energy method is developed to analyze the transient stability with the consideration of the exciter control effects. The proposed method has been tested for a single-machine-infinite bus system.

  • PDF

ANALYSIS OF A STATION BLACKOUT SCENARIO WITH AN ATLAS TEST

  • Kim, Yeon-Sik;Yu, Xin-Guo;Kang, Kyoung-Ho;Park, Hyun-Sik;Cho, Seok;Choi, Ki-Yong
    • Nuclear Engineering and Technology
    • /
    • 제45권2호
    • /
    • pp.179-190
    • /
    • 2013
  • A station blackout experiment called SBO-01 was performed at the ATLAS facility. From the SBO-01 test, the station blackout scenario can be characterized into two typical phases: A first phase characterized by decay heat removal through secondary safety valves until the SG dryouts, and a second phase characterized by an energy release through a blowdown of the primary system after the SG dryouts. During the second phase, some physical phenomena of the change over a pressurizer function, i.e., the pressurizer being full before the POSRV $1^{st}$ opening and then its function being taken by the RV, and the termination of normal natural circulation flow were identified. Finally, a core heatup occurred at a low core water level, although under a significant amount of PZR inventory, whose drainage seemed to be hindered owing to the pressurizer function by the RV. The transient of SBO-01 is well reproduced in the calculation using the MARS code.

ANS과도조건 I 및 II에서 17x17 KOFA 핵연료봉의 기계적 건전성이 유지되는 과도상태 허용 출력준위에 관한 연구 (Investigation on the Allowable Transient Power Levels to Maintain the Mechanical Integrity of the 17$\times$17 KOFA Fuel Rod During the ANS Conditions I and II)

  • Lee, Chan-Bock;Kim, Ki-Hang;Kim, Kyu-Tae
    • Nuclear Engineering and Technology
    • /
    • 제26권1호
    • /
    • pp.119-125
    • /
    • 1994
  • 핵연료봉의 과도상태 출력준위는 핵연료봉의 과도상태 거동에서 가장 중요한 변수중의 하나이다. 핵연료 성능 데이타베이스의 분석과 핵연료의 과도상태 거동에 영향을 줄 수 있는 핵연료봉 출력이력, 속중성자속, 농축도 및 주기길이 등의 인자들의 민감도 분석을 통해서, ANS 과도조건 I 및 II에서 핵연료봉의 기계적 건전성이 유지되는 허용가능 과도상태 출력을 구하기 위해 일반적으로 적용이 가능한 방법론이 유도되었으며, 이를 통해 17$\times$17 KOFA 핵연료봉의 허용가능 과도상태 출력이 연소도의 함수로써 결정되었다. 이 방법론을 도입함으로써, 현재와 같이 매 주기마다 핵연료봉 과도상태 설계분석을 수행할 필요가 없이 단지 해당주기에서의 과도상태 최대 출력준위 평가로써 핵연료봉의 과도상태 설계를 대체할 수 있으며, 17$\times$17 KOFA 핵연료에 대하 낮은 연소도영역에서 기존의 최대 허용 과도상태 출력 준위인 591 w/cm보다 큰 최대 689.5 w/cm까지 허용함으로써 원자로 운전에 유연성을 줄 수 있다.

  • PDF

과도안정도 향상을 위한 직렬콘덴서의 최적화 방안 (An Optimization Method of Series Condenser for Improvement of Transient Stability)

  • 유석구;문병서;김규호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.890-892
    • /
    • 1996
  • This paper presents a method for optimal placement of series condenser in order to improve the power system transient stability using genetic algorithms(GAs). In applying GAs, this approach utilizes two kinds of strings, one is coded by a binary finite-length for the selection of lines to install series condenser, the other is coded by a real value for the determination of injected condenser capacitance. For the formulation. this paper considers multi-objective function which is the critical energy as decelerating energy in power systems and the total injected condenser capacitance. The proposed method is applied to 9-bus, 18-line, 3-machine model system to show its effectiveness in determining the locations to install series condenser and the series condenser capacitance to be injected, simultaneously.

  • PDF