Development of Novel Method of Seismic Slope Stability Analysis (신(新) 유사정적 사면안정해석 기법 개발)

  • Yun, Seung;Park, Duhee;Lee, Seungho;Hwang, Youngchul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.1
    • /
    • pp.49-54
    • /
    • 2009
  • The seismic slope stability is most often evaluated by the pseudo-static limit analysis, in which the earthquake loading is simplified as static inertial loads acting in horizontal and/or vertical directions. The transient loading is represented by constant acceleration via the pseudostatic coefficients. The result of a pseudostatic analysis is governed by the selection of the value of the pseudostatic coefficient. However, selection of the value is very difficult and often done in an ad hoc manner without a sound physical reasoning. In addition, the maximum acceleration is commonly estimated from the design guideline, which cannot accurately estimate the dynamic response of a slope. There is a need to perform a 2D dynamic analysis to properly define the dynamic response characteristics. This paper develops a new hybrid pseudostatic method that links the modified one-dimensional seismic site response analysis and the pseudostatic algorithm. The modified site response analysis adjusts the density of the layers to simulate the change in mass and weight of the layers of the slope with depth. Multiple analyses were performed at various locations within the slope to estimate the change in seismic response of the slope. The calculated peak acceleration profiles with depth from the developed procedure were compared to those by the two-dimensional analyses. Comparisons show that the two methods result in remarkable match. The calculated profiles are used to perform pseudostatic analysis. The results show that use of peak or a fraction of acceleration at the surface can seriously underestimate or overestimate the factor of safety, and that the proposed procedure significantly enhances the reliability of a standard procedure.

  • PDF

Improvement of Dynamic Behavior of Shunt Active Power Filter Using Fuzzy Instantaneous Power Theory

  • Eskandarian, Nasser;Beromi, Yousef Alinejad;Farhangi, Shahrokh
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1303-1313
    • /
    • 2014
  • Dynamic behavior of the harmonic detection part of an active power filter (APF) has an essential role in filter compensation performances during transient conditions. Instantaneous power (p-q) theory is extensively used to design harmonic detectors for active filters. Large overshoot of p-q theory method deteriorates filter response at a large and rapid load change. In this study the harmonic estimation of an APF during transient conditions for balanced three-phase nonlinear loads is conducted. A novel fuzzy instantaneous power (FIP) theory is proposed to improve conventional p-q theory dynamic performances during transient conditions to adapt automatically to any random and rapid nonlinear load change. Adding fuzzy rules in p-q theory improves the decomposition of the alternating current components of active and reactive power signals and develops correct reference during rapid and random current variation. Modifying p-q theory internal high-pass filter performance using fuzzy rules without any drawback is a prospect. In the simulated system using MATLAB/SIMULINK, the shunt active filter is connected to a rapidly time-varying nonlinear load. The harmonic detection parts of the shunt active filter are developed for FIP theory-based and p-q theory-based algorithms. The harmonic detector hardware is also developed using the TMS320F28335 digital signal processor and connected to a laboratory nonlinear load. The software is developed for FIP theory-based and p-q theory-based algorithms. The simulation and experimental tests results verify the ability of the new technique in harmonic detection of rapid changing nonlinear loads.

Dynamic Analysis of Structures under Moving Loads in Time and Frequency Domain (이동하중을 받는 구조물에 대한 시간영역과 주파수영역에서의 동적해석)

  • Kong, Min Sik;Yhim, Sung Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.87-94
    • /
    • 2007
  • A structural dynamic analysis can be divided into a time domain analysis and a frequency domain analysis. The time domain analysis makes use of a direct integration method or a mode superposition method and the frequency domain analysis applies a DFT method. Generally the DFT method is more effective method in case of calculating response of periodic excitation. But in case of transient excitation exact solution can not be acquired. So, by modifying the response or increasing the period accuracy of solution can be enhanced. Accordingly this study analyzed dynamic responses of structures under aperiodic moving load in time domain and frequence domain. Consequently it is concluded that exact solution would be get enough using DFT method by increasing the duration of free vibration or modifying the dynamic response.

A Study on the Sloshing Impact Response Analysis for the Insulation System of Membrane Type LNG Cargo Containment System (LNG 탱크 방열구조의 슬로싱 충격 응답 해석법에 관한 연구)

  • Nho, In-Sik;Ki, Min-Seok;Lee, Jae-Man;Kim, Sung-Chan
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.531-538
    • /
    • 2011
  • To ensure the structural integrity of membrane type LNG tank, the rational assessment of impact pressure and structural responses due to sloshing should be preceded. The sloshing impact pressures acting on the insulation system of LNG tank are typical irregular loads and the structural responses caused by them also very complex behaviors including fluid structure interaction. So it is not easy to estimate them accurately and huge time consuming process would be necessary. In this research, a simplified method to analyze the dynamic structural responses of LNG tank insulation system under pressure time histories obtained by sloshing model test or numerical analysis was proposed. This technique basically based on the concept of linear combination of the triangular response functions which are obtained by the transient response analysis under the unit triangular impact pressure acting on structures in time domain. The validity of suggested method was verified through the example calculations and applied to the structural analysis of real Mark III type insulation system using the sloshing impact pressure time histories obtained by model test.

  • PDF

Effects of Rotor Misalignment in Airgap on Dynamic Response of an Eccentric Rotor in BLDC Motor

  • Kim, Tae-Jong;Kim, Kyung-Tae;Hwang, Sang-Moon;Park, No-Gill;Lee, Shi-Bok
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.12
    • /
    • pp.1576-1582
    • /
    • 2002
  • Vibration of a BLDC motor is a coupled phenomenon between mechanical characteristics and magnetic origins which takes place through the motor airgap. When relative misalignment of a rotor in the airgap is introduced during assembly, the dynamic characteristics of the motor system are affected. The rotor-motor system used in a washing machine is modeled using FETM and magnetic forces in a BLDC motor with radial rotor eccentricity are determined analytically The transient whirl responses of a rotor system supported on two roller bearings with relative misalignment in the motor airgap are investigated by considering mechanical and magnetic coupling effects. Results show that rotor misalignment in the airgap considerably affects the vibration of the rotor-motor system.

A Study on Dynamic Strength Analysis of Submarine Considering Underwater Explosion (내충격 성능을 고려한 수중함 동적 강도 설계에 관한 연구)

  • Son, Sung-Wan;Choi, Su-Hyun;Kim, Kuk-Su
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1185-1191
    • /
    • 2000
  • In general, the strength of hull structures can be estimated from stress evaluation considering static and hydro-dynamic load due to sea-wave. However, war ships such as submarine, have frequently experienced the underwater explosion and local structures of ship as well as hull girder can be damaged by the dynamic response excited from underwater non-contact explosion. When explosion happens at underwater, shock wave is radiated In early short time, then gas bubbles are generated, and expansion and contraction are repeated as they float to the surface. The shock wave causes the damage of equipment and its supporting structures, on the other hand, the hull girder strength can be lost by resonance between bubble pulsation and lowest ship natural vibration period. In this paper, the hydro-Impulse force due to bubble was calculated. Based on these results the hull girder strength of submarine was estimated from transient response analysis by using NASTRAN. Also, shock analysis for some equipment supporting structures was carried out by using DDAM. In order to evaluate the strength of these local structures due to shock wave.

  • PDF

Micro-Cracked Textile Composite Structures‘ Behavior on the Dynamic Impact Loading (동적 충격하중에 의한 미소균열 직조복합구조의 특성)

  • Hur, Hae-Kyu;Kim, Min-Sung;Jung, Jae-Kwon;Kim, Yong-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.222-227
    • /
    • 2008
  • This study is focused on an integrated numerical modeling enabling one to investigate the dynamic behavior and failure of 2-D textile composite and 3-D orthogonal woven composite structures weakened by micro-cracks and subjected to an impact load. The integrated numerical modeling is based on: I) determination of governing equations via a three-level hierarchy: micro-mechanical unit cell analysis, layer-wise analysis accounting for transverse strains and stresses, and structural analysis based on anisotropic plate layers, II) development of an efficient computational approach enabling one to perform transient response analyses of 2-D plain woven and 3-D orthogonal woven composite structures featuring the matrix cracking and exposed to time-dependent loads, III) determination of the structural characteristics of the textile-layered composites and their degraded features under various geometrical yarn shapes, and finally, IV) assessment of the implications of stiffness degradation on dynamic response to impact loads.

  • PDF

Structural Reliability Analysis of Linear Dynamic Systems with Random Properties (확률론적 선형 동적계의 구조신뢰성 해석)

  • Kim, In-Hack;Yang, Young-Soon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.34 no.4
    • /
    • pp.91-98
    • /
    • 1997
  • Most dynamic systems have various random properties m excitation and system parameters. In this paper, a procedure for structural response and reliability analysis is proposed for the linear dynamic system with random properties in both excitation and system parameters. The system parameter and response with random properties are modeled by the perturbation technique, and then the response analysis is formulated by probabilistic and vibration theories. Probabilistic FEM is also used for the calculation of mean response which is difficult by the proposed response model. The first passage analysis by the integral equation method is used to analyze the probability of failure. The integral equation method results in the first passage probability in terms of crossing rates and first passage probability densities. In this study it is assumed that excitations, system parameters and responses are Gaussian. As an application example, the probabilities of failure at transient state are calculated for a sdof system with random mass and spring constant subjected to stationary white-noise excitation and the results are compared to those of numerical simulation.

  • PDF

A Study on the Vehicle Dynamic Characteristic of Displacement Sensitive Shock Absorber (변위감응형 충격흡수기의 차량 동력학적 특성에 관한 연구)

  • 이춘태;곽동훈;정봉호;이진걸
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.1
    • /
    • pp.187-195
    • /
    • 2003
  • The performance of shock absorber is directly related to the car behaviour and performance, both for handling and ride comfort. The displacement sensitive shock absorber has two modes of damping force (i.e. soft and hard) according to the position of piston. In this study, a mathematical nonlinear dynamic model is introduced to predict the performance of displacement sensitive shock absorber. Especially in this paper, the transient zone is considered and the simulation result is well fit with experimental data. And the vehicle dynamic characteristic of displacement sensitive shock absorber is presented using quarter car simulation model. The simulation results of frequency response are compared with passive shock absorber.

Dynamic Voltage Restorer Control Using $H_{\infty}$ Algorithm ($H_{\infty}$ 알고리즘을 이용한 Dynamic Voltage Restorer의 제어)

  • Chun, Yeong-Han;Kim, Ji-Won;Jeon, Jin-Hong
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.12
    • /
    • pp.561-565
    • /
    • 2001
  • Recent trend of increasing automated factories needs supply of high quality power from the utilities. Among the items of the power quality, voltage sag can be compensated by Dynamic Voltage Restorer(DVR). The key feature of the DVR is high response with less transient period to recover from the voltage sag due to the lightning or line-to-ground faults. In this paper we report that $H_{\infty}$ controller is very promising for the practical application to the controller of DVR. Experimental results shown in this paper was obtained by applying the control algorithm to 20 kVA DVR system. The experimental set consists of IGBT-based three phase inverter and the TMS320C32-60 DSP used for main processor of the control board. To simulate the 50% voltage sag, the SCR-based experimental set was constructed.

  • PDF