• 제목/요약/키워드: transformers

검색결과 1,166건 처리시간 0.026초

The Condition Assessment of Cast Resin Molded Transformer Windings Using Vertical Analysis of Thermal Distribution

  • Lim Young-Bae;Jung Jong-Wook;Jung Jin-Soo;Cho Seong won;Kim Joon-Bum
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권5호
    • /
    • pp.191-195
    • /
    • 2005
  • This paper presents an assessment method in integrity of the windings in cast resin molded transformers by using vertical analysis of thermal distribution. The proposed method is to compare the temperature distribution in a sound specimen with that in the faulted specimen with a layer to layer short circuit. Temperature distribution was acquired by an infrared thermography system, and the Arrhenius equation was adopted to the accelerated test. The proposed method can be used to detect the failures in the transformers.

고조파 저감을 위한 다중 레벨 PWM 인버터 (A multilevel PWM Inverter for Harmonics Reduction)

  • 강필순;박성준;김철우
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권11호
    • /
    • pp.645-651
    • /
    • 2002
  • In this paper, a multilevel PWM inverter employing a cascaded transformer is presented to reduce the harmonics of output voltage and load currents. The proposed PWM inverter consists of two full-bridge modules and their corresponding transformers. The secondarics of each transformer are series-connected. So continuous output voltage levels can be synthesized from the suitable selection of the turns ratio of trasformer. And it appears an integral ratio to input DC source. Because of the cascaded connection of transformers, output filter inductor is not necessary. The operational principles and analysis are explained, and it is compared with a conventional isolated H-bridge PWM inverter. The validity of proposed multilevel inverter is verified through simulated and experimental waveform and their FFT results.

Effects of the Insulation Quality on the Frequency Response of Power Transformers

  • Abeywickrama Nilanga;Ekanayake Chandima;Serdyuk Yuriy V.;Gubanski Stanislaw M.
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권4호
    • /
    • pp.534-542
    • /
    • 2006
  • This paper presents results of frequency domain spectroscopy (FDS) measurements on oil-impregnated pressboard insulation, their analyses and use of the data for modeling high frequency response (FRA) of transformers. The dielectric responses were measured in a broad frequency range, i.e. from 0.1 mHz to 1 MHz, on model samples containing different amount of moisture. The responses were parameterized with terms representing dc conductivity, low frequency dispersion and Cole-Cole polarization mechanisms and they were thereafter used to model the FRA response of a three-phase transformer.

압전특성 및 부하변화에 따른 압전트랜스포머의 전기적 특성 (Electrical Characteristics of the Piezoelectric Transformer as a Function of Piezoelectric Properties and Load Variations)

  • 민석규;윤광희;류주현
    • 한국전기전자재료학회논문지
    • /
    • 제14권4호
    • /
    • pp.289-296
    • /
    • 2001
  • The piezoelectric transformers of 2.0x10x48 ㎣ size were fabricated with PSN-PMN-PZT(T10 and PNW-PMN-PZT(T2) composition ceramics. Effects of micro structural and piezoelectric properties on the electrical characteristics of the piezoelectric transformers were investigated. Under the fixed output power of 6 W, temperature rise of T1 transformer at the optimum load was smaller than T2 one because of fine grain size effect. Voltage step-up ratio of T1 transformer showed higher value than T2 one T1 transformer showed an excellent properties with voltage step-up ratio of 12.41, efficiency of 95.23% and temperature rise of 7.2$^{\circ}C$ at 200㏀ load resistance. And also, T2 transformer showed an excellent properties with voltage step up ratio of 9.81, efficiency of 95.51% and temperature rise of 9$^{\circ}C$ at 150㏀ load resistance.

  • PDF

고 에너지 밀도 펄스 변압기 설계 (Design of A High Energy Density Pulse Transformer)

  • 남상훈;박성수;하기만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2186-2188
    • /
    • 1999
  • A high frequency and energy density pulse transformer is a critical component of a high voltage power supply in a traveling wave tube (TWT) amplifier system. In this paper, processes of design, manufacturing, and test of the transformer are discussed. Primary voltage of the transformer is 240 V. The transformer secondary have two outputs which are 4100 V (Helix) and 2050 V (Collector). Total output power is 860 W. Normal operating frequency of the transformer is 10 kHz. In high energy density pulse transformers, temperature rise is a main problem during its operation. From our study, it was found that resonant current due to leakage inductance and stray capacitance was the main cause of temperature rise. This happens because of the inherently high turn-ratio in high voltage transformers. Solutions to reduce stray components are presented.

  • PDF

배전용 변압기를 통한 저압전원선으로의 뇌서지 전파 (Propagation of Lightning Surges on Power AC Lines through Distribution Transformers)

  • 이복희;이수봉;이동문
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.468-471
    • /
    • 2002
  • A strong need to improve the quality of electric power is increased because of increasing use of the sensitive and small-sized electronic devices. The surges on the low-voltage ac power lines are induced by nearby lightning return strokes, and the facilities for HA, OA, FA, ME as well as computer are easily damaged by high-voltage transients. The behaviors of lightning surge characteristics transferred from the primary winding to the secondary winding in distribution transformers using a Marx generator were experimentally investigated. The transfer characteristics of lightning surge associated with a custom service ground of secondary side were also examined.

  • PDF

절연계의 결함별 부분방전 패턴분석 (Analysis of PD Patterns Depending on Defect Types in Insulation System)

  • 박찬용;김황국;김성욱;지홍근;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.912-918
    • /
    • 2009
  • In this paper, we carried out a comparative analysis of partial discharge(PD) patterns caused by deterioration of cast-resin and oil insulation systems. Various electrode systems were fabricated such as needle-needle, needle-plane and plane-plane to simulate defects that may exist in the insulation system of transformers. A low-noise amplifier which has a gain of 40 dB and a frequency bandwidth of 500 kHz $\sim$ 30 MHz (-3 dB) was designed to detect small PD signals. From the analysis of acquired PD signals, we could find that a unique PD pattern is formed according to types of defect. These data will be applied usefully to diagnose insulation condition of transformers.

  • PDF

UHF 기술을 이용한 온라인 부분방전 모니터링 (On-line Insulation Diagnostic by PD Monitoring Field Practical of UHF Technique for On-line PD Monitoring)

  • 오용;최용성;황종선;이경섭
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.176-180
    • /
    • 2008
  • A field-oriented UHF system for on-line PD monitoring of transformers is designed, which has been installed inside the oil tank of transformer in a substation by two ways: on-line installing mode through the oil-valve and pre-installing mode through the man hole/hand hole cover. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

절연유에서 부분방전에 의한 극초단파 신호 특성분석 (Signal Characteristics of Ultra-high Frequency Radiation from Partial Discharge in Insulation Oil)

  • 주형준;구선근;박기준;한기선;윤진열
    • 전기학회논문지P
    • /
    • 제57권1호
    • /
    • pp.56-59
    • /
    • 2008
  • We have designed 4 types(void in insulation paper, protrusion electrode, floating electrode, surface discharge) of partial discharge(PD) defect to simulate typical faults found in oil filled power transformers. Ultra-high frequency(UHF) radiation due to PD was measured using a UHF measuring system and a conventional PD measuring system, simultaneously. Electromagnetic radiation spectra of these defects show UHF radiation up to about 1.5-2 GHz range. The phase resolved partial discharge(PRPD) patterns of UHF radiation from the PD defects were also measured and the pattern reveals distinct feature for each defect types. The UHF measuring could be used to detect PDs in oil filled transformers and analysis of the PRPD pattern should provide useful information on origin of PD signal.

다계 H-브리지 모듈로 구성된 UPFC(Unified Power Flow Compensator)의 실험적 동작분석 (Experimental Operation Analysis of Unified Power Flow Controller with Cascaded H-Bridge Modules)

  • 백승택;배병열;한병문;백두현;장병훈;윤종수;김수열
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.389-391
    • /
    • 2005
  • This paper describes experimental analysis of UPFC, which is composed of cascaded H-bridge modules and single-phase multi-winding transformers for isolation. The operational characteristic was analyzed through experimental works with a scaled model, and simulation results with PSCAD/EMTDC. The UPFC proposed In this paper can be directly connected to the transmission line without series injection transformers. It has flexibility to expand the operation voltage by increasing the number of H-bridge modules. The analysis results can be utilized to design the actual UPFC system applicable for the transmission system.

  • PDF