• 제목/요약/키워드: transformer windings

검색결과 224건 처리시간 0.025초

50 kV, 10kW 소형 고주파 전원장치 변압기 개발 (Development of a Compact 50 kV, 10 kW Transformer for High Frequency Switch Mode)

  • 손윤규;오종석;장성덕;조무현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2027-2029
    • /
    • 1998
  • We have developed a compact high frequency switch mode converter (HFSMC) power supply with DC 50 kV output voltage and 10 kW output power. Since the inverter circuit uses 25 kHz rescharging scheme, the current is flowing with t kHz. For the efficient output voltage transform performed a simple design process using the transformer principle and the commercial specification. For the DC 50 kV output, we employed 7 pa windings of secondary coils for the series stac connection of the output with full-bridge rectifi In this paper the design detail and the test re the high frequency transformer together with HFSMC power supply are presented.

  • PDF

진동신호 분석을 위한 On-Line 시스템 개발 (Developement of On-Line System for Vibration Signal Analysis)

  • 김언석;임성정;김영식;이영길;김재철;정찬수;정상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.616-619
    • /
    • 1995
  • This paper describes developement of on-line system for vibration signal analysis. In the power system, the main reason of transformer fault is due to a large amount of current by a short-circuit and a ground-fault. The electromagnetic force caused by fault-current deforms transformer windings and results in vibration pattern change. Therefore if the continuous on-line vibration monitoring on transformer is performed, an incipient failure can be detected. The developed system is composed of data acquisition devices, user interface program, signal processing program, diagnosis and trend analysis program, self diagnosis program and communication program.

  • PDF

도로/궤도 매립형 무접촉 집전장치의 전력전달 성능 개선을 위한 특성해석 (Characteristic analysis of inductive contactless power transformer used for the road/railway to improve the performance.)

  • 한경희;백수현;이병송;배창한;변윤섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1304-1306
    • /
    • 2004
  • Recently, the study for development of system having affinity for environment is on investigation. This issue is also applicable to transportation system. This paper suggested the inductive power transformer used for the road/railway applied to contactless power transfer system. The two secondary windings, large gaped magnetic structure and horizontal alignment between primary and secondary coil for that transformer approach a process for improvement of contactless power transfer system performance.

  • PDF

A Transformer Protection Relay Based on Induced Voltages

  • Kang, Yong-Cheol;Lee, Byung-Eun
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권2호
    • /
    • pp.70-78
    • /
    • 2003
  • This paper describes a transformer protection relay based on induced voltages. The ratio of the induced voltages of the primary and secondary windings is equal to the turns ratio during normal operating conditions such as magnetic inrush, overexcitation, and steady state, but it differs from the turns ratio in the case of internal faults. For a single-phase and a three-phase Y-Y transformer, the induced voltages are estimated and the ratios are compared with the turns ratio. For three-phase Y-Δ transformers, the differences between the induced voltages are estimated to use the line currents because delta-winding currents are practically unavailable. The proposed relay is tested under various conditions such as magnetic inrush, internal winding faults, overexcitation, and different core characteristics. The results evidently indicate that the relay successfully discriminates internal faults from magnetic inrush and overexcitation. This paper concludes by implementing the relay into a TMS320C6701 digital signal processor and reports satisfactory results. The relay requires no hysteresis data and can reduce the operating time of a relay.

평면 동판 권선을 이용한 Flyback 변압기 설계에 관한 연구 (A Study on the Design of Flyback Transformer using Flat copper winding)

  • 김종해
    • 전기전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.445-455
    • /
    • 2022
  • 본 논문에서는 90W급 LED-TV용 DC-DC Flyback 컨버터에 사용되고 있는 소형화 및 권선 자동화에 적합한 사출형 평면 동판 권선 방식의 Flyback 변압기 최적화 설계에 대해서 나타낸다. 또한 본 논문에서는 수동권선방식의 기존 양산 Flyback 변압기에 비해 권선 자동화, Trans 체적 저감 및 전기적 특성 동질성 향상이 가능한 사출형 평면 동판 권선 방식의 Flyback 변압기를 제안한다. 특히 본 논문에서 제안한 사출형 평면 동판 권선 변압기는 권선 자동화를 위하여 수직형 권선 방식으로 구성한다. 본 논문 제안한 사출형 평면 동판 권선 방식의 Flyback 변압기의 1차측과 2차측 권선은 각각 기존 권선, 3중 절연 권선 및 사출형 평면 동판권선을 사용하였다. 최종적으로 Maxwell 2D 및 3D Tool을 이용한 시뮬레이션 결과를 토대로 본 논문에서 제안한 소형화 및 권선 자동화에 적합한 사출형 평면 동판 권선 방식의 Flyback 변압기 최적화 설계를 수행하였다.

A Cascaded D-STATCOM Integrated with a Distribution Transformer for Medium-voltage Reactive Power Compensation

  • Lei, Ertao;Yin, Xianggen;Chen, Yu;Lai, Jinmu
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.522-532
    • /
    • 2017
  • This paper presents a novel integrated structure for a cascaded distribution static compensator (D-STATCOM) and distribution transformer for medium-voltage reactive power compensation. The cascaded multilevel converter is connected to a system via a group of special designed taps on the primary windings of the Dyn11 connection distribution transformer. The three-phase winding taps are symmetrically arranged and the connection point voltage can be decreased to half of the line-to-line voltage at most. Thus, the voltage stress for the D-STATCOM is reduced and a compromise between the voltage rating and the current rating can be achieved. The spare capacity of the distribution transformer can also be fully used. The working mechanism is explained in detail and a modified control strategy is proposed for reactive power compensation. Finally, both simulation and scaled-down prototype experimental results are provided to verify the feasibility and effectiveness of the proposed connection structure and control strategy.

High Efficiency Alternating Current Driver for Capacitive Loads Using a Current-Balance Transformer

  • Baek, Jong-Bok;Cho, Bo-Hyung;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제11권1호
    • /
    • pp.97-104
    • /
    • 2011
  • This paper proposes a new alternating current driving method for highly capacitive loads such as plasma display panels or piezoelectric actuators, etc. In the proposed scheme, a current balance transformer, which has two windings with the same turn-ratio, provides not only a resonance inductance for energy recovery but also a current balance among all of the switching devices of the driver for current stress reduction. The smaller conduction loss than conventional circuits occurs due to the dual conduction paths which are parallel each other in the current balance transformer. Also, the leakage inductances of the transformer are utilized as resonant inductors for energy recovery by the series resonance to the capacitive load. Furthermore, the resonance contributes to the small switching losses of the switching devices by soft-switching operation. To confirm the validity of the proposed circuit, prototype hardware with a 12-inch mercury-free flat fluorescent lamp is implemented. The experimental results are compared with a conventional energy-recovery circuit from the perspective of luminance performances.

쇄교자속비를 이용한 변압기 보호 알고리즘 (A Transformer protective Relaying Algorithm Based on Increment of Flux Linkages)

  • 강용철;이병은;김은숙;원성호;임의재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.53-55
    • /
    • 2003
  • This paper propose a transformer protective relaying algorithm based on the increment of flux linkages (RIFL) of the Primary and secondary windings. The RIFL is equal to the turn ratio for all operating conditions except an internal faults. For a single-phase transformer and three-phase Y-Y transformer, the increments of flux linkages are calculated and their ratios are compared with the turn ratio. For a three-phase Y-$\triangle$ transformer, the difference of the increments of flux linkages are calculated to use the line currents instead of the delta winding currents, which are practically unavailable. Their ratios are compared with the turn ratio. The results of various tests show that the algorithm successfully discriminates internal faults from normal operation conditions such as magnetic inrush and overexcitation. The algorithm can not only detect internal winding faults, but reduce the relay's operating time.

  • PDF

2차권선의 병렬연결에 따른 하이브리드형 초전도 한류기의 특성 (Characteristics of Hybrid-Type SFCL according to the Parallel Connection of Secondary Windings)

  • 황종선;조용선;최효상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.208-211
    • /
    • 2006
  • We have analyzed operating characteristics of hybrid-type superconducting fault current limiter (SFCL) according to the parallel connection of secondary windings with $YBa_{2}Cu_{3}O_{7}$ (YBCO) films. The turn ratio between the primary and secondary windings of each reactor was 63:21. Hybrid-type SFCL using a transformer with parallel reactors could reduce the unbalanced quench caused by differences of the critical current density between YBCO films. We found that hybrid-type SFCL having parallel connection induced simultaneous quench between the superconducting elements. The quench-starting point at this time was almost same. When the applied voltage was 200V, the limiting current in the hybrid-type SFCL with a serial connection was lowered to 34 percent than that in the SFCL with a parallel connection. In the meantime, when the voltage generated in the superconducting elements was the same, the current value in the parallel connection was 60 percent less than in the serial connection. The voltage generated in the primary winding also showed the similar behavior. In conclusion, we found that the fault current was limited more effectively in the SFCL with the serial connection but the power burden of the superconducting elements was reduced in the parallel connection.

  • PDF

Study on the Transfer Functions for Detecting Windings Displacement of Power Transformers with Impulse Method

  • Shon, Chae-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.876-883
    • /
    • 2012
  • The paper investigates three types of transfer function methods for detecting displacements of winding in a model transformer. To acquire these transfer functions, the measuring method of input voltage, current and its response is used in impulse method. The applied impulse voltages had three rising times, which were short rising time (less than 0.6 ${\mu}s$), medium rising time (about 0.8 ${\mu}s$) and long rising time (about 1 ${\mu}s$) in front waves. Every 10 measurements of voltage and current waves were averaged from 50 measurements of voltage and current waves. These transfer functions were tested in normal, 24mm elevated and 48mm elevated windings conditions and were analyzed with correlation coefficients and spectrum deviations. In the analysis, the results depend on the types of transfer functions and the rising times of input voltages.