• 제목/요약/키워드: transfer time

검색결과 4,873건 처리시간 0.034초

루프 전달 회복을 통한 이중 적분 모터의 무진동 제어 (Vibration-free Control of Double Integrator Typed Motor via Loop Transfer Recovery)

  • 서상민
    • 한국소음진동공학회논문집
    • /
    • 제20권10호
    • /
    • pp.900-906
    • /
    • 2010
  • This note proposes vibration-free motor control through modified LQG/LTR methodology. A conventional LQG/LTR method is a design tool in the frequency domain. However, unlike the conventional one, the proposed one is a time response based design method. This feature is firstly designed by parameterized settling time control gain through the target loop design procedure and the feature is secondly realized by loop transfer recovery. In order to show convergence to the target loop transfer functions, asymptotic behaviors of the open and the closed loop transfer functions are shown. At the conclusion, it is verified that the proposed method is robustly stable to parametric uncertainties through ${\mu}$-plot.

Convection Heat Transfer Coefficient of a Meat Cube in a Continuous Flow Sterilizing System

  • Hong, Ji-Hyang;Han, Young-Joe;Chung, Jong-Hoon
    • Food Science and Biotechnology
    • /
    • 제14권3호
    • /
    • pp.328-333
    • /
    • 2005
  • Finite difference model and dynamic thermal property evaluation system were developed to estimate convection heat transfer coefficient by modeling temperature-time profile of beef cube in continuous flow sterilizing system. As input parameters of the model, specific heat and thermal conductivity values of beef frankfurter meat were independently measured from 20 to $80^{\circ}C$. Convection heat transfer coefficient was estimated by comparing simulated and measured temperature-time profiles. Actual temperature-time profiles of meat cube were measured at flow rates of 15, 30, and 45 L/min and viscosities from 0 to 15 cp, and mean values of convection heat transfer coefficients ranged from 792 to $2107\;W/m^2{\cdot}K$. Convection heat transfer coefficient increased with increase in flow rate and decreased as viscosity increased.

수직관 내 초임계상태 물의 천이상태 대류열전달현상에 관한 연구 (A Study on the Transient Convective Heat Transfer for Supercritical Water in a Vertical Tube)

  • 이상호
    • 설비공학논문집
    • /
    • 제17권12호
    • /
    • pp.1095-1105
    • /
    • 2005
  • Numerical analysis has been carried out to investigate transient turbulent convective heat transfer in a vertical tube for supercritical water near the thermodynamic critical point. Heat transfer and fluid flow in the tube we strongly coupled due to the large variations of thermodynamic and transport properties such as density, specific heat, and turbulent viscosity. As pressure in the tube approaches to the critical pressure, the properties variation with time becomes larger. Heat transfer coefficient rapidly decreases along the tube near the pseudocritical temperature at the tube wall for $P_R<1.2$. Stanton number variation with time is largely reduced in the region of gas-like phase in comparison with Nusselt number. Turbulent viscosity ratio close to the wall increases near the pseudocritical temperature and it gradually decreases with time.

한우에서 수정란 이식의 효율 증진에 관한 연구 III. 이식 시기의 조건이 수정란 이식 후 수태율에 미치는 영향 (Studies on the Improvement of Embryo Transfer Efficiency in Korean Cattle III. Effect of Pregnancy Rate after Embryo Transfer by Condition of Transfer Time)

  • 김흥률;김덕임;김진호;박철진;이문성;김창근;정영채
    • 한국수정란이식학회지
    • /
    • 제13권1호
    • /
    • pp.69-76
    • /
    • 1998
  • This study was carried out to establish an effective system for embryo transfer techniques by analyzing several factors affecting in-vivo embryo transfer in Korean cattle Embryos were transferred into a toral of 301 recipients. The results obtained in studies on the factors affecting pregnancy rate after embryo transfer by condition of transfer time were as follows ; 1. The pregnancy rate by the seasons of transferred fresh and frozen embryos were not different, but the pregnancy rate was slightly higher in summer(80.8%). 2. The pregnancy rate by the days of embryo transfer after estrus were not different when fresh embryos were transferred, but the pregnancy rate was highest at 8 days when frozen embryos were transferred(P<0.01, 40.0%). 3. The pregnancy rate at estrus synchronization was remarkably higher with PGF$_2$$\alpha$ treated than natural (P<0.05, 70.4%, 43.4%). 4. The pragnancy rate by the degree of estrus synchronization was best when the estrus was synchronized in both fresh and frozen embryos (83.3% and 29.7%, respectively), but the pregnancy rate was not different among $\pm$2 days. But the pregnancy rate of frozen embryos were slightly higher when the recipients exhibited estrus earlier than donors.

  • PDF

지자기장 및 지자기 전달함수의 시간적 변동성 분석

  • 양준모;이덕기;권병두;류용규;윤용훈
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2004년도 대한지구물리학회.한국지구물리탐사학회 공동학술대회 초록집
    • /
    • pp.103-113
    • /
    • 2004
  • We investigate the time-variational characteristics of power spectrum and transfer function of geomagnetic field by robust estimation technique. In the case of power spectrums of geomagnetic field, there are some the periodic fluctuations related with solar activity, Meanwhile, the geomagnetic transfer function shows so considerable weak time-variational fluctuation that the estimations of transfer function seem to be comparatively stable in time-variant view.

  • PDF

Analysis of Wireless Power Transfer Characteristics for Multiple Receivers by Time Sharing Technique

  • Park, Jong-Min;Nam, Sang-Wook
    • Journal of electromagnetic engineering and science
    • /
    • 제11권3호
    • /
    • pp.183-185
    • /
    • 2011
  • A multiple charging method for a wireless power transfer system (WPTS) in the near-field region is proposed. We analyzed the frequency characteristics of multiple receivers in the near-field region. The results suggested that the time division WPTS can achieve efficient and equal power transmission at multiple receivers. We conclude that this system has an advantage for charging multiple receivers.

Geometrically non-linear dynamic analysis of plates by an improved finite element-transfer matrix method on a microcomputer

  • Chen, YuHua
    • Structural Engineering and Mechanics
    • /
    • 제2권4호
    • /
    • pp.395-402
    • /
    • 1994
  • An improved finite element-transfer matrix method is applied to the transient analysis of plates with large displacement under various excitations. In the present method, the transfer of state vectors from left to right in a combined finite element-transfer matrix method is changed into the transfer of generally incremental stiffness equations of every section from left to right. Furthermore, in this method, the propagation of round-off errors occurring in recursive multiplications of transfer and point matrices is avoided. The Newmark-${\beta}$ method is employed for time integration and the modified Newton-Raphson method for equilibrium iteration in each time step. An ITNONDL-W program based on this method using the IBM-PC/AT microcomputer is developed. Finally numerical examples are presented to demonstrate the accuracy as well as the potential of the proposed method for dynamic large deflection analysis of plates with random boundaries under various excitations.

Dynamics of Resonant Energy Transfer in OH Vibrations of Liquid Water

  • Yang, Mi-No
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권3호
    • /
    • pp.885-892
    • /
    • 2012
  • Energy transfer dynamics of excited vibrational energy of OH stretching bonds in liquid water is theoretically studied. With time-dependent vibrational Hamiltonian obtained from a mixed quantum/classical calculation, we construct a master equation describing the energy transfer dynamics. Survival probability predicted by the master equation is compared with numerically exact one and we found that incoherent picture of energy transfer is reasonably valid for long-time population dynamics. Within the incoherent picture, we assess the validity of independent pair approximation (IPA) often introduced in the theoretical models utilized in the analysis of experimental data. Our results support that the IPA is almost perfectly valid as applied for the vibrational energy transfer in liquid water. However, proper incorporation of radial and orientational correlations between two OH bonds is found to be critical for a theory to be quantitatively valid. Consequently, it is suggested that the Forster model should be generalized by including the effects of the pair correlations in order to be applied for vibrational energy transfer in liquid water.

막비등 영역에서 액적-벽면 충돌 시 충돌각도가 열전달에 미치는 영향에 관한 실험적 연구 (Experimental Study of Collision Angle Effects on Heat Transfer During Droplet-wall Collision in Film Boiling Regime)

  • 박준석;김형대
    • 한국분무공학회지
    • /
    • 제22권3호
    • /
    • pp.129-136
    • /
    • 2017
  • Effects of collision angle on heat transfer characteristics of a liquid droplet impinging on a heated wall above the Leidenfrost point temperature were experimentally investigated. The heated wall and droplet temperatures were $506^{\circ}C$ and $100^{\circ}C$, respectively, and the impact angle varied from $20^{\circ}$ to $90^{\circ}$ while the normal collision velocity was constant at 0.27 m/s. The droplet collision behaviors and the surface temperature distribution were measured using synchronized high-speed video and infrared cameras. The major physical parameters influencing upon droplet-wall collision heat transfer, such as residence time, wall heat flux, effective heat transfer area, heat transfer amount, were analyzed. It was found at the constant normal collision velocity that the residence time, wall heat flux and effective heat transfer area were hardly not changed, resulting in the almost constant heat transfer amount.

이차함수 근사화를 이용한 가용송전용량과 송전신뢰 및 설비편익 여유도 산정 (Calculation of CBM, TRM and ATC using Quadratic Function Approximation)

  • 이효상;신상헌;신동준;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권5호
    • /
    • pp.296-301
    • /
    • 2004
  • The Available Transfer Capability (ATC) is defined as the measure of the transfer capability remaining in the physical transmission network for further commercial activity above already committed uses. Available Transfer Capability (ATC) calculation is a complicated task, which involves the determination I of total transfer capability (TTC), transmission reliability margin (TRM) and capability benefit margin (CBM). As the electrical power industry is restructured and the electrical power exchange is updated per hour, it is important to accurately and rapidly quantify the available transfer capability (ATC) of the transmission system. In ATC calculation,. the existing CPF method is accurate but it has long calculation time. On the contrary, the method using PTDF is fast but it has relatively a considerable error. This paper proposed QFA method, which can reduce calculation time comparing with CPF method and has few errors in ATC calculation. It proved that the method can calculate ATC more fast and accurately in case study using IEEE 24 bus RTS.