• 제목/요약/키워드: transfer length

검색결과 1,313건 처리시간 0.028초

Deflection Limit based on Vibration Serviceability of Railway Bridges Considering the Correlation between Train Speed and Vertical Acceleration on Coach (열차의 주행속도와 차체연직가속도의 상관관계를 고려한 철도교량의 진동사용성 처짐 한계)

  • Jeon, Bub-Gyu;Kim, Nam-Sik;Kim, Sung-Il
    • Journal of the Korean Society for Railway
    • /
    • 제14권6호
    • /
    • pp.545-554
    • /
    • 2011
  • In order to get dynamic serviceability of a train travelling on a railway bridge, comfort limits with the deflection of bridge and vertical acceleration on car body are proposed in Eurocode, Shinkansen design criteria, The design guideline of the Honam High-speed railway. The design guideline of the Honam High-speed railway has quoted Eurocode. Therefore it is expected that supplementation of comfort limit of railway bridge according to expansion of span length and the improvement traveling speed of trains in the future would relatively fall behind developed countries in railway. Therefore, in order to secure technological competitiveness in world market, the study was conducted to propose the deflection limit based on vibration serviceability of railway bridges that can consider bridge-train interaction and travelling speed increase. The parameter study and bridge-train dynamic interaction analysis was conducted to figure out the correlation of vertical acceleration on car body and bridge displacement according to the increase in travelling speed. Also, the trend of increasing vertical acceleration on car body according to the increase in travelling speed was confirmed, and the amplification coefficient of vertical acceleration on car body was suggested. And the deflection form and vibration of the bridge were assumed to be in harmonic motion, and transfer function and the amplification coefficient were used to develop the dynamic serviceability deflection limit of the high-speed railway bridge as a formula.

Study on the stress distribution depending on the bone type and implant abutment connection by finite element analysis (지대주 연결 형태와 골질에 따른 저작압이 임프란트 주위골내 응력분포에 미치는 영향)

  • Park, Hyun-Soo;Lim, Sung-Bin;Chung, Chin-Hyung;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • 제36권2호
    • /
    • pp.531-554
    • /
    • 2006
  • Oral implants must fulfill certain criteria arising from special demands of function, which include biocompatibility, adequate mechanical strength, optimum soft and hard tissue integration, and transmission of functional forces to bone within physiological limits. And one of the critical elements influencing the long-term uncompromise functioning of oral implants is load distribution at the implant- bone interface, Factors that affect the load transfer at the bone-implant interface include the type of loading, material properties of the implant and prosthesis, implant geometry, surface structure, quality and quantity of the surrounding bone, and nature of the bone-implant interface. To understand the biomechanical behavior of dental implants, validation of stress and strain measurements is required. The finite element analysis (FEA) has been applied to the dental implant field to predict stress distribution patterns in the implant-bone interface by comparison of various implant designs. This method offers the advantage of solving complex structural problems by dividing them into smaller and simpler interrelated sections by using mathematical techniques. The purpose of this study was to evaluate the stresses induced around the implants in bone using FEA, A 3D FEA computer software (SOLIDWORKS 2004, DASSO SYSTEM, France) was used for the analysis of clinical simulations. Two types (external and internal) of implants of 4.1 mm diameter, 12.0 mm length were buried in 4 types of bone modeled. Vertical and oblique forces of lOON were applied on the center of the abutment, and the values of von Mises equivalent stress at the implant-bone interface were computed. The results showed that von Mises stresses at the marginal. bone were higher under oblique load than under vertical load, and the stresses were higher at the lingual marginal bone than at the buccal marginal bone under oblique load. Under vertical and oblique load, the stress in type I, II, III bone was found to be the highest at the marginal bone and the lowest at the bone around apical portions of implant. Higher stresses occurred at the top of the crestal region and lower stresses occurred near the tip of the implant with greater thickness of the cortical shell while high stresses surrounded the fixture apex for type N. The stresses in the crestal region were higher in Model 2 than in Model 1, the stresses near the tip of the implant were higher in Model 1 than Model 2, and Model 2 showed more effective stress distribution than Model.

Bearing Strength of Steel Baseplate under Eccentric Loads (편심축력(偏心軸力)을 받는 철골구조(鐵骨構造) 주각부(柱脚部)의 지압강도(支壓强度))

  • Choi, Mun Sik;Min, Byung Yeol
    • Journal of Korean Society of Steel Construction
    • /
    • 제15권6호통권67호
    • /
    • pp.683-691
    • /
    • 2003
  • Recently, the steel has been increaseingly used as an integrated part of high-rise buildings, which often composed of steel structures, steel reinforced concrete structures and composite structures. The steel base is designed to transfer the stresses induced from steel column to the reinforced concrete footing through the base plate. However, in the design of steel structures and steel reinforced concrete structure, it is generally difficult to evaluate the bearing strength of the steel base subjected to large axial force. Furthermore, the material used in steel base is quite different from those used in other connections and a load transferring mechanism of steel base is very complicated in nature. Therefore, a special attention must be placed in design and construction of steel base. In generally, the bearing strength test and research of the steel base subjected to concentrated load are carried out. But, in the design of the structures, uniaxial eccentric load is loaded to the steel base of the steel structures. In this research, the bearing strength and the me of failure considering eccentric loads and eccentric length, were experimented when eccentric load is loaded to the steel base of steel structures. Based on the test results, a basic design reference is suggested for a reasonable design of steel structures, steel reinforced concrete structures and composite structures.

CMOS 소자 응용을 위한 Plasma doping과 Silicide 형성

  • Choe, Jang-Hun;Do, Seung-U;Seo, Yeong-Ho;Lee, Yong-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.456-456
    • /
    • 2010
  • CMOS 소자가 서브마이크론($0.1\;{\mu}m$) 이하로 스케일다운 되면서 단채널 효과(short channel effect), 게이트 산화막(gate oxide)의 누설전류(leakage current)의 증가와 높은 직렬저항(series resistance) 등의 문제가 발생한다. CMOS 소자의 구동전류(drive current)를 높이고, 단채널 효과를 줄이기 위한 가장 효율적인 방법은 소스 및 드레인의 얕은 접합(shallow junction) 형성과 직렬 저항을 줄이는 것이다. 플라즈마 도핑 방법은 플라즈마 밀도 컨트롤, 주입 바이어스 전압 조절 등을 통해 저 에너지 이온주입법보다 기판 손상 및 표면 결함의 생성을 억제하면서 고농도로 얕은 접합을 형성할 수 있다. 그리고 얕은 접합을 형성하기 위해 주입된 불순물의 활성화와 확산을 위해 후속 열처리 공정은 높은 온도에서 짧은 시간 열처리하여 불순물 물질의 활성화를 높여주면서 열처리로 인한 접합 깊이를 얕게 해야 한다. 그러나 접합의 깊이가 줄어듦에 따라서 소스 및 드레인의 표면 저항(sheet resistance)과 접촉저항(contact resistance)이 급격하게 증가하는 문제점이 있다. 이러한 표면저항과 접촉저항을 줄이기 위한 방안으로 실리사이드 박막(silicide thin film)을 형성하는 방법이 사용되고 있다. 본 논문에서는 (100) p-type 웨이퍼 He(90 %) 가스로 희석된 $PH_3$(10 %) 가스를 사용하여 플라즈마 도핑을 실시하였다. 10 mTorr의 압력에서 200 W RF 파워를 인가하여 플라즈마를 생성하였고 도핑은 바이어스 전압 -1 kV에서 60 초 동안 실시하였다. 얕은 접합을 형성하기 위한 불순물의 활성화는 ArF(193 nm) excimer laser를 통해 $460\;mJ/cm^2$의 에니지로 열처리를 실시하였다. 그리고 낮은 접촉비저항과 표면저항을 얻기 위해 metal sputter를 통해 TiN/Ti를 $800/400\;{\AA}$ 증착하고 metal RTP를 사용하여 실리사이드 형성 온도를 $650{\sim}800^{\circ}C$까지 60 초 동안 열처리를 실시하여 $TiSi_2$ 박막을 형성하였다. 그리고 $TiSi_2$의 두께를 측정하기 위해 TEM(Transmission Electron Microscopy)을 측정하였다. 화학적 결합상태를 분석하기 위해 XPS(X-ray photoelectronic)와 XRD(X-ray diffraction)를 측정하였다. 접촉비저항, 접촉저항과 표면저항을 분석하기 위해 TLM(Transfer Length Method) 패턴을 제작하여 I-V 특성을 측정하였다. TEM 측정결과 $TiSi_2$의 두께는 약 $580{\AA}$ 정도이고 morphology는 안정적이고 실리사이드 집괴 현상은 발견되지 않았다. XPS와 XRD 분석결과 실리사이드 형성 온도가 $700^{\circ}C$에서 C54 형태의 $TiSi_2$ 박막이 형성되었고 가장 낮은 접촉비저항과 접촉저항 값을 가진다.

  • PDF

Effects of Excising In Vitro-Formed Roots on Acclimatization of Micropropagated Cassava Plantlets (카사바의 미세증식에서 기내 발생 부정근의 절단이 순화에 미치는 영향)

  • Yoon, Sil;Cho, Duck-Yee;Soh, Woong Young
    • Korean Journal of Plant Tissue Culture
    • /
    • 제28권2호
    • /
    • pp.103-108
    • /
    • 2001
  • The in vitro plantlets of cassava (Manihot esculenta Crantz cv. MColl 22) could be regenerated from nodal explant cultures in a liquid MS basal medium containing 0.01 mg/L zeatin for 2 weeks. The plantlets of 1.5∼2.5 cm in shoot length were transplanted to a glass bottle containing fine sand and acclimated under non-sterile conditions after excising their intact roots by: 1) prune leaving roots base of 1∼1.5 cm; 2) complete removal of roots; and 3) cutting off the rooting zone. The majority of in vitro-formed intact roots continued growth after transferred to soil, and all of the damaged roots stopped further growth. The plantlets with excised roots began to develop new roots within 7∼10 days after being transferred to a glass bottle, and a few of the pruned roots developed lateral roots from the remaining portion. Pruning and removal of in vitro roots resulted in a high survival rate (>87%), and did not significantly affect ex vitro root regeneration and acclimation, but the plantlets in which the rooting zone had been cut-off showed 73% survival rate. Pruning or removal of in vitro roots before transfer of plantlets is recommended for useful method of commercial micropropagation because of easier handling and high survival rate of plantlets.

  • PDF

A New High-Yielding and Late Bolting Welsh Onion Cultivar 'Yeomyeong' (만추대 다수성 파 신품종 '여명')

  • Kim, Cheol-Woo;Lee, Eul-Tai;Choi, In-Hu;Jang, Young-Seok;Suh, Sae-Jung;Hyun, Dong-Yun;Bang, Jin-Ki
    • Korean Journal of Breeding Science
    • /
    • 제43권3호
    • /
    • pp.180-183
    • /
    • 2011
  • 'Yeomyeong', a new welsh onion (Allium fistulosum L.) variety, is developed by the Bioenergy Crop Research Center, NICS, RDA in 2004. This variety, as interspecific $F_1$ hybrid, is developed by a cross between onion (Allium. cepa L.) and welsh onion (A. fistulosum L). The first cross was conducted in 2003 between MOS8, onion male sterile line and G2, welsh onion inbred line. Horticultural and yield characteristics of this hybrid $F_1$ line was investigated in greenhouse for 2 years from 2004 to 2005 with fall cropping cultivation. It has a single pseudostem plant type, anthocyanin-colored pseudostem, and male sterile umbel. It showed intermediate plant type of the maternal parents in overall plant characteristics. 'Yeomyeong' is fall sawing variety and has higher plant height and pseudostem length than that of check variety 'Gumjang'. The yield potential of this variety was about 130.1MT/ha in greenhouse in spring harvseting season. This variety would be adaptable to the fall sowing cultivation in green house.

Performance Verification of WAVE Communication Technology for Railway Application (차량용 무선통신기술(WAVE)의 철도 적용을 위한 성능검증)

  • Kim, Keum-Bee;Ryu, Sang-Hwan;Choi, Kyu-Hyoung
    • Journal of the Korean Society for Railway
    • /
    • 제19권4호
    • /
    • pp.456-467
    • /
    • 2016
  • Wireless Access in Vehicular Environments (WAVE) communication technology, which provides vehicleto-vehicle and vehicle-to-infrastructure communication and offers safe and convenient service, has been developed for application to an Intelligent Transport System (ITS). This paper provides field test results on a study of the feasibility of WAVE technology application to railway communication systems. A test railway communication system based on WAVE technology has been built along the Daebul line and a newly developed EMU. Field tests have been carried out according to the communication function requirements for LTE - R. The test results show that the railway communication system based on WAVE technology meets the functional requirements: maximum transmission length is 730m, maximum transfer delay is 5.69ms, and maximum interruption time is 1.36s; other tests including throughput test, video data transmission test, VoIP data test, and channel switching test also produced results that meets the functional requirements. These results suggest that WAVE technology can be applied to the railway communication system, enabling Vehicle-to-Wayside communication.

Flow blockage analysis for fuel assembly in a lead-based fast reactor

  • Wang, Chenglong;Wu, Di;Gui, Minyang;Cai, Rong;Zhu, Dahuan;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3217-3228
    • /
    • 2021
  • Flow blockage of the fuel assembly in the lead-based fast reactor (LFR) may produce critical local spots, which will result in cladding failure and threaten reactor safety. In this study, the flow blockage characteristics were analyzed with the sub-channel analysis method, and the circumferentially-varied method was employed for considering the non-uniform distribution of circumferential temperature. The developed sub-channel analysis code SACOS-PB was validated by a heat transfer experiment in a blocked 19-rod bundle cooled by lead-bismuth eutectic. The deviations between the predicted coolant temperature and experimental values are within ±5%, including small and large flow blockage scenarios. And the temperature distributions of the fuel rod could be better simulated by the circumferentially-varied method for the small blockage scenario. Based on the validated code, the analysis of blockage characteristics was conducted. It could be seen from the temperature and flow distributions that a large blockage accident is more destructive compared with a small one. The sensitivity analysis shows that the closer the blockage location is to the exit, the more dangerous the accident is. Similarly, a larger blockage length will lead to a more serious case. And a higher exit temperature will be generated resulting from a higher peak coolant temperature of the blocked region. This work could provide a reference for the future design and development of the LFR.

Surrogate Models and Genetic Algorithm Application to Approximate Optimization of Discrete Design for A60 Class Deck Penetration Piece (A60 급 갑판 관통 관의 이산설계 근사최적화를 위한 대리모델과 유전자 알고리즘 응용)

  • Park, Woo Chang;Song, Chang Yong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • 제27권2호
    • /
    • pp.377-386
    • /
    • 2021
  • The A60 class deck penetration piece is a fire-resistant system installed on a horizontal compartment to prevent flame spreading and protect lives in fire accidents in ships and offshore plants. This study deals with approximate optimization using discrete variables for the fire resistance design of an A60 class deck penetration piece using different surrogate models and a genetic algorithm. Transient heat transfer analysis was performed to evaluate the fire resistance design of the A60 class deck penetration piece. For the approximate optimization of the piece, the length, diameter, material type, and insulation density were applied to discrete design variables, and temperature, productivity, and cost constraints were considered. The approximate optimum design problem based on the surrogate models was formulated such that the discrete design variables were determined by minimizing the weight of the piece subjected to the constraints. The surrogate models used in the approximate optimization were the response surface model, Kriging model, and radial basis function-based neural network. The approximate optimization results were compared with the actual analysis results in terms of approximate accuracy. The radial basis function-based neural network showed the most accurate optimum design results for the fire resistance design of the A60 class deck penetration piece.