• 제목/요약/키워드: transfer connection

검색결과 440건 처리시간 0.023초

내측연결 시스템에서 임플란트 고정체의 경부 형태에 따른 지지골에서의 유한요소 응력분석 (Finite Element Stress Analysis in Supporting Bone according to Crest Module Shape of Fixture in Internal Connection System)

  • 박영남;김희중;오상호;정재헌
    • 구강회복응용과학지
    • /
    • 제22권1호
    • /
    • pp.55-74
    • /
    • 2006
  • The external contour of an implant can have significant effects on the load transfer characteristics and may result in different bone failure rates for different implant system. The purpose of this study was to investigate the effects of crest module shape and occlusal load direction on bone failure modes of five commercially available dental implant systems. Five different implant systems with internal connection; ITI (Model 1), Astra (Model 2), Bicon (Model 3), Friadent (Model 4), and Paragon (Model 5), comparable in size, but different in thread profile and cest module shapes, were compared using the finite element method. Conclusively, in the internal connection system of the implant-abutment connection methods, the stress-induced pattern at the supporting bone according to the abutment connection form had differenence among them, and implants with narrowing crestal module cross-sections at the top of the cortical bone created more favorable load transfer characteristics in this region. But it is considered that the future study is necessary about how this difference in the magnitude of the stress have an effect on the practical clinic.

수도권 광역철도역 환승센터 및 연계시설확충을 위한 법제도 개선방안 (Reformation of Legislation and System for Improving Seoul Metropolitan Railway Transfer Center and Connection Transportation Facility)

  • 김시곤;김지연
    • 대한토목학회논문집
    • /
    • 제37권1호
    • /
    • pp.119-124
    • /
    • 2017
  • 본 논문에서는 경기도 철도역 203개소 중 이용자 수요수준, 연계교통망 수준, 관련계획 수준을 종합적으로 고려하여 광역환승센터로서 18개 역사를 도출하였다. 이를 바탕으로 18개 역사의 연계서비스 수준을 분석하였다. 그 결과 9개소가 "D~F"등급 수준으로 매우 열악한 수준으로 분석되었다. 광역환승센터의 기능을 확보하고 철도이용의 편리성을 극대화하기 위해서는 연계서비스수준을 "C"등급 이상 수준으로 향상시키는 방법론을 제시하였다. 최종적으로는 경기도 18개 광역환승센터의 원활한 확보를 위하여 환승센터에 대한 중앙정부 재정 지원비율을 명시하고 있는 대도시권 광역교통 관리에 관한 특별법 시행령 개선방안으로 현행 30%에서 50%까지 향상시키는 방안과 지원대상을 총사업비로 확대하는 방안을 제안하였다. 또한, 연계서비스 수준을 확보하기 위하여 국가통합교통체계효율화법 시행령에서 연계도로는 50%, 연계철도는 70% 지원하는 방안을 제시하였다.

H형강 보-기둥 접합부의 보 웨브 단부접합길이에 따른 모멘트전달효율 평가 (Evaluation of Moment Transfer Efficiency According to the Connection Length of the Column Flange and the Beam Web of the H-beam Column Connection)

  • 홍영주;오상훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권6호
    • /
    • pp.193-203
    • /
    • 2022
  • 본 연구는 국내에서 주로 사용되는 강구조 보-기둥 접합상세와 논스캘럽접합상세의 내진성능을 비교하기 위해 실대형 정적반복실험과 실험과 동일한 모델링 통한 FEM해석을 진행하였다. 정량적인 수치비교를 위해 이전연구에서 사용된 변형률집중지수와 모멘트전달효율을을 인용하였다. 보 웨브의 용접면적 감소에 따라 플랜지 부분의 변형률이 증가되어 회전각에 따른 소성변형능력이 감소되거나 취성파단이 일어나는 현상을 보였다. 해석결과와 실험결과 비교시 H형 전체단면적에 대한 웨브 용접비가 60%이하로 떨어질 경우 취성파단이 일어날 가능성이 높아지는 경향이 나타났다.

Shear transfer mechanism in connections involving concrete filled steel columns under shear forces

  • De Nardin, Silvana;El Debs, Ana Lucia H.C.
    • Steel and Composite Structures
    • /
    • 제28권4호
    • /
    • pp.449-460
    • /
    • 2018
  • This paper reports the experimental results of three through bolt beam-column connections under pure shear forces using modified push-out tests. The investigated specimens include extended end-plates and six through-bolts connecting square concrete-filled steel tubular column (S-CFST) to steel beams. The main goal of this study is to investigate if and how the mechanical shear connectors, such as steel angles and stud bolts, contribute to the shear transfer mechanisms in the steel-concrete interface of the composite column. The contribution of shear studs and steel angles to improve the shear resistance of steel-concrete interface in through-bolt connections was investigated using tests. The results showed that their contribution is not significant when the beam-column connection is included in the push-out tests. The specimens failed by pure shear of the long bolts, and the ultimate load can be predicted using the shear resistance of the bolts under shear forces. The predicted values of load allowed obtaining a good agreement with the tests results.

프리캐스트 전단벽 시스템의 건식접합부에 관한 연구 (Dry Connections for Precast Shear Wall Systems)

  • 홍성걸;임우영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.530-533
    • /
    • 2006
  • This thesis investigates the behavior of precast wall systems with a new vertical connection which are proportioned by the displacement based design. The proposed precast wall systems are supposed to provide additional spaces and seismic strengthening in remodeling existing residential buildings. For a fast remodeling constructions using PC walls require an efficient, economic fabrication method. A C-type vertical connections for PC wall systems is proposed for transfer of bending moment between walls in the vertical direction while a shear key in the center of wall is prepared to transfer shear forces by bearing. The proposed vertical connection allows us easy fabrication because of different direction of slots at the edges of wall. The dimension of C-type connection components are determined by engineering models and a series of test.

  • PDF

C형 접합부를 이용한 프리캐스트 전단벽 시스템에 관한 연구 (Precast Shear Wall Systems with C Type Connections)

  • 홍성걸;임우영
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.217-224
    • /
    • 2006
  • This thesis investigates the behavior of precast wall systems with a new vertical connection which are proportioned by the displacement based design. The proposed precast wall systems are supposed to provide additional spaces and seismic strengthening in remodeling existing residential buildings. For a fast remodeling constructions using PC wails require an efficient, economic fabrication method. A C-type vertical connections for PC wall systems is proposed for transfer of bending moment between walls in the vertical direction while a shear key in the center of wall is prepared to transfer shear forces by bearing. The proposed vertical connection allows us easy fabrication because of different direction of slots at the edges of wall. The dimension of C-type connection components are determined by engineering models and a series of test.

  • PDF

Experimental investigations on resilient beam-column end-plate connection with structural fuse

  • Arunkumar Chandrasekaran;Umamaheswari Nambiappan
    • Steel and Composite Structures
    • /
    • 제47권3호
    • /
    • pp.315-337
    • /
    • 2023
  • The steel structure is an assembly of individual structural members joined together by connections. The connections are the focal point to transfer the forces which is susceptible to damage easily. It is challenging to replace the affected connection parts after an earthquake. Hence, steel plates are utilised as a structural fuse that absorbs connection forces and fails first. The objective of the present research is to develop a beam-column end plate connection with single and dual fuse and study the effect of single fuse, dual fuse and combined action of fuse and damper. In this research, seismic resilient beam-column end plate connection is developed in the form of structural fuse. The novel connection consists of one main fuse was placed horizontally and secondary fuse was placed vertically over main fuse. The specimens are fabricated with the variation in number of fuse (single and dual) and position of fuse (beam flange top and bottom). From the fabricated ten specimens five specimens were loaded monotonically and five cyclically. The experimental results are compared with Finite Element Analysis results of Arunkumar and Umamaheswari (2022). The results are critically assessed in the aspect of moment-rotation behaviour, strain in connection components, connection stiffness, energy dissipation characteristics and ductility. While comparing the performance of total five specimens, the connection with fuse exhibited superior performance than the conventional connection. An equation is proposed for the moment of resistance of end-plate connection without and with structural fuse.

각형강관 기둥을 가진 철골모멘트 접합부의 변형능력 (Deformation Capacity of Steel Moment Connections with RHS Column)

  • 김영주;오상훈;유홍식
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.249-258
    • /
    • 2006
  • In this paper, deformation capacity of steel moment connections with RHS column was investigated. Initially, non-linear finite element analysis of five bate steel beam models was conducted. The models were designed to have different detail at their beam-to-column connection, so that the flexural moment capacity was different respectively. Analysis results showed 4hat the moment transfer efficiency of the analytical model with RHS-column was poor when comparing to model with WF(Wide flnage)-column due to out-of-plane deformation of the RHS-column flange. The presence of scallop and thin plate of RHS column was also a reason of the decrease of moment transfer efficiency, which would result in a potential fracture of tile steel beam-to-column connections. Further test on beam-to-column connections with RHS column revealed that the moment transfer efficiency of a beam web decreased due to the out-of-plane deformation of column flange, which led to premature failure of the connection.

  • PDF

T 형강을 사용한 합성골조 보-기둥 접합부의 휨 저항성능에 관한 연구 (A Study on the Moment Resisting Performance of the Hybrid Beam-Column Connection System with Structural Tee)

  • 임대성;최광호;김상식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.597-602
    • /
    • 1998
  • The composite systems, consisting of R/C Columns-Steel Beams, are reasonable structures because of their constructional and economical advantages, workability and so on. But, it is difficult to apply the composite systems to actual design due to material dissimilarity and complicate stress flow in the connection. This study aims to propose the hybrid beam-column connection system with structural tee and through experimental research make clear the shear and moment resistance capacity and stress transfer mechanism.

  • PDF

시뮬레이션을 이용한 ATM 교환기 연결 절단율 추정 연구 (The Estimation of Cutoff Connection Rates on the ATM Switching System Using Simulation)

  • 정명기
    • 한국시뮬레이션학회논문지
    • /
    • 제6권2호
    • /
    • pp.117-124
    • /
    • 1997
  • A simulation model for the estimation of cutoff connection rate in the asynchronous transfer mode (ATM) switching system under multimedia traffic environments is presented. The simulator is developed by the integration of the AweSim tool with user-written C++ routines that model the internal structures of operational details of the switching system. For the case study, the simulator is applied to the ATM switching system developed by Electronics and Telecommunications Research Institute (ETRI) to compare design alternatives according to the cutoff connection rates.

  • PDF