• 제목/요약/키워드: transfer column

검색결과 361건 처리시간 0.029초

Investigation of shear transfer mechanisms in repaired damaged concrete columns strengthened with RC jackets

  • Achillopoulou, D.V;Karabinis, A.I
    • Structural Engineering and Mechanics
    • /
    • 제47권4호
    • /
    • pp.575-598
    • /
    • 2013
  • The study presents the results of an experimental program concerning the shear force transfer between reinforced concrete (RC) jackets and existing columns with damages. In order to investigate the effectiveness of the repair method applied and the contribution of each shear transfer mechanism of the interface. It includes 22 concrete columns (core) (of 24,37MPa concrete strength) with square section (150mm side, 500 mm height and scale 1:2). Ten columns had initial construction damages and twelve were subjected to initial axial load. Sixteen columns have full jacketing at all four faces with 80mm thickness (of 31,7MPa concrete strength) and contain longitudinal bars (of 500MPa nominal strength) and closed stirrups spaced at 25mm, 50mm or 100mm (of 220MPa nominal strength). Fourteen of them contain dowels at the interface between old and new concrete. All columns were subjected to repeated (pseudo-seismic) axial compression with increasing deformation cycles up to failure with or without jacketing. Two load patterns were selected to examine the difference of the behavior of columns. The effects of the initial damages, of the reinforcement of the interface (dowels) and of the confinement generated by the stirrups are investigated through axial- deformation (slip) diagrams and the energy absorbed diagrams. The results indicate that the initial damages affect the total behavior of the column and the capacity of the interface to shear mechanisms and to slip: a) the maximum bearing load of old column is decreased affecting at the same time the loading capacity of the jacketed element, b) suitable repair of initially damaged specimens increases the capacity of the jacketed column to transfer load through the interface.

구아니딘계 초염기 흡수제에 의한 충진탑에서의 이산화탄소 포집 특성 (Carbon Dioxide Absorption in a Packed Column Using Guanidine-based Superbase Solution)

  • 최영민;홍연기;유정균
    • Korean Chemical Engineering Research
    • /
    • 제54권5호
    • /
    • pp.648-652
    • /
    • 2016
  • 본 연구에서는 구아니딘계 초염기인 1,1,3,3-테트라메틸 구아니딘(TMG)과 에틸렌 글라이콜로 구성된 비수계 흡수제를 충진탑에 적용하여 이산화탄소 흡수특성을 고찰하였다. 흡수탑은 내경이 1 in이고 높이는 0.6 m이며 탑 내부는 $0.16in{\times}0.16in$의 규격을 갖는 다공 충진물로 채웠다. 흡수탑에서의 이산화탄소 제거 효율에 대한 흡수제 농도, 조업온도 등의 영향 뿐 아니라 이들이 물질전달 저항에 미치는 영향을 고찰하였다. 이산화탄소에 대한 TMG의 로딩값은 약 ${\alpha}=1.0mol_{CO2}/mol_{TMG}$에 달하였으며 이산화탄소가 적게 로딩된 흡수제에서는 총괄 물질전달 계수가 TMG의 농도에 비례하였으나 ${\alpha}=0.5$ 이상의 로딩값에서는 총괄 물질전달계수가 오히려 감소하였다. 이는 흡수제의 이산화탄소에 대한 로딩값에 따른 흡수제 점도 증가로 인한 액체상에서의 물질전달 저항 증가로 해석할 수 있다.

A study on the fire performance and heat transfer of the HPC column with fiber-cocktail in ISO fire under loading condition

  • Kim, Hyung-Jun;Kim, Heung-Youl;Kwon, In Kyu;Kwon, Ki-Hyuk;Min, Byung-Yeol;Cho, Bum-Yean
    • Computers and Concrete
    • /
    • 제12권5호
    • /
    • pp.717-737
    • /
    • 2013
  • In this study, experiment and numerical analysis were conducted to identify the heat transfer characteristics and behavior of high-strength concrete upon a fire. The numerical analysis was employed to forecast the characteristics and properties of the high-strength concrete upon a fire, which can not be accomplished through a fire test due to the specific conditions and restrictions associated with the test. The result of the numerical analysis was compared with that of the test to verify the reliability of the analysis. In the numerical analysis of the heat transfer characteristics and behavior of 80 and 100 MPa high-strength concrete upon a fire, the commercial software of ABAQUS(V.6.8) was used. It was observed from the experiment that the contraction of the concrete with fiber-cocktail was mitigated by 25~55 % compared with that without fiber-cocktail because the fiber controlled the heat transfer of the concrete and thus improved the fire-resistance performance of the column.

Structural Design and Construction of Mega Braced Frame System for Tall Buildings

  • Chung, Kwangryang;Yoo, Seounghoon
    • 국제초고층학회논문집
    • /
    • 제8권3호
    • /
    • pp.169-175
    • /
    • 2019
  • Recently, two unique high rise buildings have been designed and constructed in Korea. The two buildings, which consist of mega braces and mega columns, are 70-story, 105-story high rise buildings. Through two external structural frame systems, it will be analyzed mechanical and structural characteristic mega column and mega brace system in this report. Particularly, the joint has been studied through the analytical method based on the load transfer mechanism at the point where a mega brace and mega column meets.

TLCD와 TSD를 이용한 새로운 형태의 양방향 감쇠기 설계변수 (Design Parameter of a New Type Bi-directional Damper Using a Tuned Liquid Column Damper and a Tuned Sloshing Damper)

  • 민경원
    • 한국소음진동공학회논문집
    • /
    • 제19권8호
    • /
    • pp.850-856
    • /
    • 2009
  • A new type bi-directional damper using a tuned liquid column damper(TLCD) and a tuned sloshing damper(TSD) is introduced in this study. Two dampers are usually needed to reduce wind-induced responses of tall buildings since they are along and across wind ones. The proposed damper has the advantage of controlling both responses with one damper. One of objectives of this study is to derive analytical dynamics to investigate coupled effects due to TLCD and TSD. Another objective is to address the effect of coupled control force due to TLCD and TSD on the dynamic characteristic of the damper based on analytical dynamics. Shaking table test is undertaken to experimentally grasp dynamic characteristics of the damper under white noise excitation. Its dynamic characteristic is expressed by the transfer function from the shaking table acceleration to the control force generated from the damper. Finally, its design parameters are identified based on the coupled dynamics, which include the mass ratio of horizontal liquid column to total liquid for a TLCD, the participation factor of the fundamental liquid sloshing for a TSD and damping ratio for both cases.

Passive control of seismically excited structures by the liquid column vibration absorber

  • Konar, Tanmoy;Ghosh, Aparna Dey
    • Structural Engineering and Mechanics
    • /
    • 제36권5호
    • /
    • pp.561-573
    • /
    • 2010
  • The potential of the liquid column vibration absorber (LCVA) as a seismic vibration control device for structures has been explored in this paper. In this work, the structure has been modeled as a linear, viscously damped single-degree-of-freedom (SDOF) system. The governing differential equations of motion for the damper liquid and for the coupled structure-LCVA system have been derived from dynamic equilibrium. The nonlinear orifice damping in the LCVA has been linearized by a stochastic equivalent linearization technique. A transfer function formulation for the structure-LCVA system has been presented. The design parameters of the LCVA have been identified and by applying the transfer function formulation the optimum combination of these parameters has been determined to obtain the most efficient control performance of the LCVA in terms of the reduction in the root-mean-square (r.m.s.) displacement response of the structure. The study has been carried out for an example structure subjected to base input characterized by a white noise power spectral density function (PSDF). The sensitivity of the performance of the LCVA to the coefficient of head loss and to the tuning ratio have also been examined and compared with that of the liquid column damper (LCD). Finally, a simulation study has been carried out with a recorded accelerogram, to demonstrate the effectiveness of the LCVA.

화해를 입은 철근콘크리트 기둥의 구조성능 저하 (Deterioration of Structural Capacity of Fire-Damaged Reinforced Concrete Column)

  • 이차돈;신영수;홍성걸;이승환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.371-374
    • /
    • 2003
  • The degree of changes in mechanical properties of fire-damaged reinforced concrete column depends mostly on sectional geometry, duration exposed to fire, and moisture containment. In order to reasonably assess the deterioration of structural capacity of fire-damaged reinforced concrete column, it is necessary to develop a theoretical model predicting column behavior based on nonlinear heat transfer equation in addition to the traditional mechanics. This research focuses on the development of theoretical model to predict moment-curvature relations of fire-damaged reinforced column. The model is used for the assessment of structural capacity of fire-damaged column in terms of moment-curvature relations and PM interaction curves.

  • PDF

태양열이용 직접접촉 열교환기내의 열전달 특성연구 (Heat Transfer Characteristics of Direct Contact Heat Exchanger Using Solar Energy)

  • 강용혁;전명석;윤환기;천원기
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1995년도 춘계학술발표회 초록집
    • /
    • pp.78-81
    • /
    • 1995
  • In the present study, the spray column type of direct contact heat exchangers are studied experimentally to analyze heat transfer characteristics for solar energy utilization. These experiments are carried out in the line of solar heating system, major results are as follows ; 1) the flow and aspect of working fluid drop for maxium heat transfer 2) efficiency and volumetric heat transfer coefficient of D. C. H. X. with a heavier working fluid are higher than those of D. C. H. X. with a lighter working fluid

  • PDF

Chromatography용 Paper, $\mu$RPC Column 및 Superose Column을 이용한 정자의 이동을 자극하는 난포액 성분의 분리 (Separation of Follicular Fluid Components Stimulating Sperm Migration with Chromatographic Paper, $=mu$RPC and Superose Columns)

  • 박영식
    • 한국수정란이식학회지
    • /
    • 제13권3호
    • /
    • pp.301-312
    • /
    • 1998
  • 난포액내 함유되어 있는 단백질성분 중에서 sucrose 층으로부터 정자의 swim-up 이동을 자 극하는 성분을 분리하기 위하여 paper chromatography (PC) 및 reverse phase column (RPC) 과 superose column (SC)를 이용한 액체 chromatography의 분리효과를 조사하였던 바 결과는 다음과 같다. 1. Chromatography용 paper로 분리한 각 band 의 성분은 첨가농도가 증가할수록 정자의 이동과 운동을 자극하였으며, 특히 band 1 성분은 정자의 이동을 유의하게 증가시켰다. 그러나, 동일 첨가수준에서 bands 성분의 정자 이동과 운동자극효과는 난포액의 효과에 비하여 유의하게 낮았다. 2. $\mu$RPC를 이용 2~5mm 난포로 부터 분리한 성분중 RT3.33, RT7.00, RTl3.87 및 RTl6.6A 성분은 정자의 이동을 자극하였으나, 자극효과는 매우 적었다. 3. $\mu$RPC를 이용 10mm 난포로 부터 분리한 성분은 정자의 이동과 활력을 자극하지 않았다. 4. SC를 이용 2-5mm 난포로 부터 분리한 성분 중 RVI.35 성분과 RV0.82 성분은 정자의 이동과 운동을 유의하게 자극하였다. 결론적으로 난포액내 정자의 이동과 운동을 자극하는 단백질 성분은 superose column을 이용하여 효과적으로 분리할 수 있으며, 분리된 RVI.35 성분과 RV0.82 성분은 정자의 swim-up 분리를 자극하였다.

  • PDF