• 제목/요약/키워드: transducers

검색결과 855건 처리시간 0.023초

초음파 트랜스듀서에서의 Cross talk 분석 및 방지 방안 (Analysis and Reduction of the Cross Talk in Ultrasonic Transducers)

  • 노용래;김영신;이수성
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2001년도 추계학술발표대회 논문집 제20권 2호
    • /
    • pp.215-218
    • /
    • 2001
  • Finite element models are constructed using the commercial code ANSYS for two most representative types of ultrasonic transducers, cMUTs and piezoelectric transducers. Calculation result shows the origin and level of cross talk between array elements in each transducer type For reduction of the cross talk level, the effects of various structural variations are Investigated for each transducer type. The results say that proper design of the coupling isolation structures between the transducing elements can significantly reduce the cross talk in ultrasonic transducers.

  • PDF

이방성을 고려한 원통형 압전 변환기의 반경방향 진동 특성 해석 (Radial Vibration Analysis of Cylindrical Piezoelectric Transducers Considering Anisotrpy)

  • 이정구;김진오
    • 대한기계학회논문집A
    • /
    • 제28권3호
    • /
    • pp.274-280
    • /
    • 2004
  • This paper presents the analysis fur the radial vibration characteristics of cylindrical piezoelectric transducers. Taking into account the piezoelectric anisotropy, the differential equations of piezoelectric radial motion have been derived in terms of radial displacement and electric potential. Applying mechanical and electric boundary conditions has yielded a characteristic equation for radial vibration. Numerical analysis also has been carried out by using the finite element method. Theoretical calculations of the fundamental natural frequency have been compared with the experimental observations for transducers of several sizes. Comparison with the previous report of theoretical analysis simplifying the piezoelectric anisotropy into isotropy concludes that isotropic analysis is a reasonable process to predict the vibration characteristics of piezoelectric transducers.

압전 비틀림 파동 변환기 제작 및 평가 (Fabrication and Evaluation of Piezoelectric Torsional Transducers)

  • 권오수;김진오
    • 비파괴검사학회지
    • /
    • 제21권4호
    • /
    • pp.434-438
    • /
    • 2001
  • 봉에서 전파하는 비틀림파를 발생시키는 압전 비틀림 파동 변환기를 제작하였다. 비틀림 파동을 발생시키는 원리는 원주방향으로 분극된 압전 원판에 인가된 두께 방향 전압에 의해 나타나는 원주방향 전단운동이다. 압전 비틀림 원판을 제작한 후, 공진 주파수를 낮추기 위하여 랑주방(Langevin)형 비틀림 변환기를 제작하였다. 제작된 변환기들의 공진 주파수를 측정한 결과, 해석에 의해 예상된 특성과 잘 일치하였다.

  • PDF

압전 세라믹-고분자 1-3형 복합 압전체 트랜스듀서의 펄스에코 특성 (Pulse-echo Response of Piezoceramic-Polymer 1-3 Type Composite Transducers)

  • 최헌일;박정학;이수호;사공건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1403-1405
    • /
    • 1994
  • In this study, the piezoelectric transducers with 1-3 connectivity have maded. A piezoelectric ceramic PZT prepared by Wet-Dry Combination method is used as a filler in Eccogel polymer matrix. The pulse-echo response for 1-3 type composite transducers were carried out in water. It was observed that the transmitting and receiving sensitivity of 1-3 type composite transducers were improved in comparison with that or solid PZT transducer. The reason is for that 1-3 composites have a hish piezoelectric voltage coefficients, The period of pulse-echo response for the transducer is in a good agreement with the resonant frequency of self-maded composite transducer.

  • PDF

유한요소법을 이용한 Tonpilz형 수중 음향 트랜스듀서 설계 (Tonpilz Type Underwater Acoustic Transducers Design using Finite Element Method)

  • 조요한;김정석;이정민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.247-250
    • /
    • 2005
  • Underwater acoustic transducers are widely used for SONAR application, whose important design parameters are shapes, materials, dimensions and supporting structures. Practical design method of transducers consists of manufacturing, experiments and modifications so that It requires much time and expenses. In this study, an analytical method was developed for the Tonpilz type transducers using the commercial finite element analysis code ATILA which can solve the electro-mechanical coupling Problems. A finite element model was established including the transducer elements such as ceramic stack, head mass, tall mass, tensile bolt, and molding layers. The proposed model was verified and modified by comparing the in-air and in-water test results of prototypes. The developed analysis method will be effectively used for the sensitivity analysis of design parameters in transducer design process.

  • PDF

광대역 심벌 트랜스듀서 배열 설계 (Design of a wideband cymbal transducer array)

  • 김동현;노용래
    • 한국음향학회지
    • /
    • 제39권3호
    • /
    • pp.170-178
    • /
    • 2020
  • 심벌 트랜스듀서는 높은 품질계수와 낮은 에너지 변환 효율성을 가지기 때문에 단일보다는 배열형으로 많이 사용된다. 단, 배열형으로 사용하면 구성 트랜스듀서들 간의 상호작용으로 인해 주파수 특성에 많은 변화가 나타난다. 본 연구에서는 이러한 성질을 이용하여 초광대역 특성을 가지는 배열형 심벌 트랜스듀서의 구조를 설계하였다. 먼저, 특정 중심 주파수를 가지는 심벌 트랜스듀서를 설계하였다. 그리고 설계된 심벌 트랜스듀서들로 2×2 평면 배열을 구성하는데, 구성 트랜스듀서들이 모두 동일하거나 엇갈리는 분극 방향을 가지도록 하였다. 이 배열구조에 대해서 구성 트랜스듀서들 간의 중심 주파수 차이와 트랜스듀서들 중심과 중심 간의 간격이 전체 배열 구조의 음향특성에 미치는 영향을 분석하였다. 이 결과를 바탕으로 비대역폭이 최대가 되는 배열형 심벌 트랜스듀서의 구조를 도출하였다.

A Cost-effective Light Emitting Diode-acoustic System for Preclinical Ocular Applications

  • Choi, Hojong;Ryu, Jaemyung;Yeom, Jung-Yeol
    • Current Optics and Photonics
    • /
    • 제2권1호
    • /
    • pp.59-68
    • /
    • 2018
  • Opto-acoustic systems provide structural and functional information regarding biological tissues. Conventional opto-acoustic systems typically employ continuous or pulsed lasers as transmission sources. Compared to lasers, light emitting diodes (LEDs) are cost-effective and relatively portable excitation sources but are non, coherent. Therefore, in this study, a relatively low cost lens - a type of Ramsden eyepiece - was specially designed to theoretically calculate the illumination and achieve a constant brightness across the pupil of an eye. In order to verify the capability of the developed light-emitting diode-acoustic (LEDA) systems, we carried out experiments on bovine and bigeye tuna eyeball samples, which are of similar size to the human eye, using low frequency (10 MHz) and high frequency (25 MHz) ultrasound transducers. High frequency ultrasound transducers are able to provide higher spatial resolution compared to low frequency ultrasound transducers at the expense of penetration depth. Using the 10 MHz and 25 MHz ultrasound transducers, acceptable echo signals (3.82, 3.94, and 5.84 mV at 10 MHz and 282, 1557, 2356 mV at 25 MHz) from depth greater than 3 cm and 6 cm from the anterior surface of the eye were obtained. We thereby confirmed that the LEDA system using a pulsed LED with the designed Ramsden eyepiece lens, used in conjunction with low and high frequency ultrasound transducers, has the potential to be a cost-effective alternative method, while providing adequate acoustic signals from bovine and bigeye tuna ocular areas.

AE 측정을 위한 탐촉자의 보정에 대한 고찰 (A Study on the Transducer Calibration for Acoustic Emission Measurement)

  • 김교원
    • 지질공학
    • /
    • 제6권2호
    • /
    • pp.53-58
    • /
    • 1996
  • 암석 시료의 파괴시에 발생하는 AE신호를 측정하여 파괴와 관련된 미세균열의 발생원에 대한 연구를 위하여서는 탐촉자에서 기록장치까지 전과정에 대한 검증이 필요하다. 특히 탐촉자는 기계적인 진동을 전기신호로 전환하는 기능을 가진 예민한 장치로서 다양한 인자에 의하여 예민도가 달라질 수 있기 때문에 보정시험을 실리하여야 한다. 압전 압력형 PAC 탐촉자를 NBS나 DG의 변위형 탐촉자에 의하여 보정하는 시험을 실시하였다. NBS 및 PAC탐촉자는 파의 입사방위각에는 무관하나 입사각에는 예민하게 반응한다. 즉, 입사각이 $90^{\circ}$ 일 때에는 입사각 $15^{\circ}$ 이하 일 때보다 약 10배의 큰 출력을 나타내었다. 또한, 시험에 사용된 PAC 탐촉자가의 경우 강도에 대한 개별 예민도의 차이가 최대 약 40%이었다. 압력형 PAC 탐촉자는 변위형 표준탐촉자로 절대치 보정시험을 실시한 결과 보정계수는 평균 77mv/pm이었다.

  • PDF

Concrete structural health monitoring using piezoceramic-based wireless sensor networks

  • Li, Peng;Gu, Haichang;Song, Gangbing;Zheng, Rong;Mo, Y.L.
    • Smart Structures and Systems
    • /
    • 제6권5_6호
    • /
    • pp.731-748
    • /
    • 2010
  • Impact detection and health monitoring are very important tasks for civil infrastructures, such as bridges. Piezoceramic based transducers are widely researched for these tasks due to the piezoceramic material's inherent advantages of dual sensing and actuation ability, which enables the active sensing method for structural health monitoring with a network of piezoceramic transducers. Wireless sensor networks, which are easy for deployment, have great potential in health monitoring systems for large civil infrastructures to identify early-age damages. However, most commercial wireless sensor networks are general purpose and may not be optimized for a network of piezoceramic based transducers. Wireless networks of piezoceramic transducers for active sensing have special requirements, such as relatively high sampling rate (at a few-thousand Hz), incorporation of an amplifier for the piezoceramic element for actuation, and low energy consumption for actuation. In this paper, a wireless network is specially designed for piezoceramic transducers to implement impact detection and active sensing for structural health monitoring. A power efficient embedded system is designed to form the wireless sensor network that is capable of high sampling rate. A 32 bit RISC wireless microcontroller is chosen as the main processor. Detailed design of the hardware system and software system of the wireless sensor network is presented in this paper. To verify the functionality of the wireless sensor network, it is deployed on a two-story concrete frame with embedded piezoceramic transducers, and the active sensing property of piezoceramic material is used to detect the damage in the structure. Experimental results show that the wireless sensor network can effectively implement active sensing and impact detection with high sampling rate while maintaining low power consumption by performing offline data processing and minimizing wireless communication.

압전 세라믹을 이용한 스마트 웨어용 진동-촉각 액추에이터 (Vibro-tactile Actuator for Smart Wear Applications Using Piezoelectric Ceramic Transducers)

  • 손정우;강한결;최승복;김기우
    • 한국소음진동공학회논문집
    • /
    • 제26권7호
    • /
    • pp.881-887
    • /
    • 2016
  • In this study, the vibration-based tactile actuator for smart wear applications is presented by using piezoelectric ceramic transducers. The compact wireless actuation system is constructed with a high voltage piezoelectric amplifier, a microcontroller, wireless communication module, and rechargeable lithium-polymer battery. For the wireless communication between a hardware and an operator, the bluetooth-based wireless communication system is prepared and the user interface is provided via smart phone applications. From a series of experimental user studies, it is demonstrated that the proposed vibro-tactile actuator based on piezoelectric ceramic transducers can be effectively applied to smart wear applications.