엘리베이터 사고예방을 위한 승강기 부품의 최적 수명 추정에 관한 연구 (A Study on the Estimation of the Optimum Lifetime of Elevator Components for Elevator Accident Prevention)

  • 김한진;황민수;최옥만;이안기;김재철
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1278-1284
    • /
    • 2017
  • As of December 2016, there are 608,828 elevators in operation in Korea and 179,790 elevators in more than 15 years. 30.4% of all elevator are aging. Improved maintenance of the elevator and proactive replacement of the parts of the elevator can extend the lifetime of the elevator and ensure safety. An unclean environment reduces the lifetime of elevator parts. If you do not clean the environment and prevent preventive parts replacement, eventually shortening the lifetime of the parts connected to the failed part or causing more damage will result in greater economic loss. Also, the risk of elevator safety accidents due to failures of elevator parts will be increased accordingly. The study of optimum replacement time of elevator parts will contribute to prevention of safety accident of elevator and prolongation of lifetime of elevator through preventive replacement of elevator parts.

악성코드 포렌식을 위한 패킹 파일 탐지에 관한 연구 (Packed PE File Detection for Malware Forensics)

  • 한승원;이상진
    • 정보처리학회논문지C
    • /
    • 제16C권5호
    • /
    • pp.555-562
    • /
    • 2009
  • 악성코드 사고 조사에서 가장 중요한 것은 신속하게 악성코드를 탐지하고 수집하는 것이다. 기존의 조사 방법은 시그니쳐 기반의 안티바이러스 소프트웨어를 이용하는 것이다. 시그니쳐 기반의 탐지는 실행파일 패킹, 암호화 등을 통해 쉽게 탐지를 회피할 수 있다. 그렇기 때문에 악성코드 조사에서 패킹을 탐지하는 것도 중요한 일이다. 패킹탐지는 패킹 시그니쳐 기반과 엔트로피 기반의 탐지 방법이 있다. 패킹 시그니쳐기반의 탐지는 새로운 패킹을 탐지하지 못하는 문제가 있다. 그리고 엔트로피 기반의 탐지 방법은 오탐의 문제가 존재한다. 본 논문에서는 진입점 섹션의 엔트로피 통계와 패킹의 필수적인 특징인 'write' 속성을 이용하여 패킹을 탐지하는 기법을 제시한다. 그리고 패킹 PE 파일을 탐지하는 도구를 구현하고 도구의 성능을 평가한다.

결상 시 누전전류 발생과 오동작 방지 기능을 갖는 결상보호기 개발에 관한 연구 (A Study on Development of Open-Phase Protector Having Leakage Current Generation and Incapable Operation Prevention at Open-Phase Accident)

  • 곽동걸
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.182-187
    • /
    • 2015
  • In the three-phase power system, when any one-phase or two-phases is open-phase, the unbalanced current flows and the single-phase power supplies to three-phase loads. Specially, motor coil and transformer coil receive over-current. As a result, great damage as well as electrical fire can occur to the power system. In order to improve these problems, this paper proposes that an open-phase detection device is designed by a new algorithm using electric potential difference between the resultant voltage of neutral point and ground, and a control circuit topology of open-phase protector is composed of highly efficient semiconductor devices. It improves response speed and reliability. The control algorithm circuit also operates the cut-off of a conventional residual current protective device (RCD) which flows an enforced leakage current to ground wire at open-phase accident. Furthermore, time delay circuit is added to prevent the incapable operation of open-phase protector about instantaneous open-phase not open-phase fault. The time delay circuit improves more reliability.

원자로 용기 외벽냉각을 위한 1차원 이상유동 실험 및 해석 (1-D Two-phase Flow Investigation for External Reactor Vessel Cooling)

  • 김재철;박래준;조영로;김상백;김신;하광순
    • 대한기계학회논문집B
    • /
    • 제31권5호
    • /
    • pp.482-490
    • /
    • 2007
  • When a molten corium is relocated in a lower head of a reactor vessel, the ERVC (External Reactor Vessel Cooling) system is actuated as coolant is supplied into a reactor cavity to remove a decay heat from the molten corium during a severe accident. To achieve this severe accident mitigation strategy, the two-phase natural circulation flow in the annular gap between the external reactor vessel and the insulation should be formed sufficiently by designing the coolant inlet/outlet area and gap size adequately on the insulation device. For this reason, one-dimensional natural circulation flow tests and the simple analysis were conducted to estimate the natural circulation flow under the ERVC condition of APR1400. The experimental facility is one-dimensional and scaled down as the half height and 1/238 channel area of the APR1400 reactor vessel. The calculated circulation flow rate was similar to experimental ones within about ${\pm}$15% error bounds and depended on the form loss due to the inlet/outlet area.

차량-보행자 충돌사고 재구성 해석: 차량 속도 계산과 불확실성 (Reconstruction Analysis of Vehicle-pedestrian Collision Accidents: Calculations and Uncertainties of Vehicle Speed)

  • 한인환
    • 한국자동차공학회논문집
    • /
    • 제19권5호
    • /
    • pp.82-91
    • /
    • 2011
  • In this paper, a planar model for mechanics of a vehicle/pedestrian collision incorporating road gradient is derived to evaluate the pre-collision speed of vehicle. It takes into account a few physical variables and parameters of popular wrap and forward projection collisions, which include horizontal distance traveled between primary and secondary impacts with the vehicle, launch angle, center-of-gravity height at launch, distance from launch to rest, pedestrian-ground drag factor, the pre-collision vehicle speed and road gradient. The model including road gradient is derived analytically for reconstruction of pedestrian collision accidents, and evaluates the vehicle speed from the pedestrian throw distance. The model coefficients have physical interpretations and are determined through direct calculation. This work shows that the road gradient has a significant effect on the evaluation of the vehicle speed and must be considered in accident cases with inclined road. In additions, foreign/domestic empirical cases and multibody dynamic simulation results are used to construct a least-squares fitted model that has the same structure of the analytical one that provides an estimate of the vehicle speed based on the pedestrian throw distance and the band within which the vehicle speed would be expected to be in 95% of cases.

반주기 변조된 송신파형과 대지전위 측정을 이용한 지중 케이블 누전 고장점 탐지 시스템 (Electric Leakage Point Detection System of Underground Power Cable Using Half-period Modulated Transmission Waveform and Earth Electric Potential Measurement)

  • 전정채;유재근
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2113-2118
    • /
    • 2016
  • The precise detection of electric leakage point of underground power cable is very important to reduce cost and time of maintenance and prevent electric shock accident through expedite repair of electric leakage point. This paper proposes a electric leakage point detection system underground power cable using of half-period modulated transmission waveform and earth electric potential measurement. The developed system is composed of transmitter to generate the wanted pulse waveform, receiver to measure and display earth electric potential by the transmitted pulse in electric leakage point and PC Software program to display of GPS coordinate on detection cable line. The performance of the electric leakage point detection system was tested in the constructed underground cable leakage detection test bed. The test results on signal generation voltage precision of signal transmitter, mean detection earth voltage, mean detection leakage current and electric leakage point detection error showed the developed system can be used in electric leakage point detection underground power cable.

냉각탑 백연방지의 성능 향상에 관한 실험적 연구 (An Experimental Study on the Cooling Tower of Plume Prevention and Performance Improvements)

  • 정순영;이병천;김성
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.578-584
    • /
    • 2019
  • The occurrence of white plume in the cooling tower is phenomenon that the steam in the air through the cooling tower fan is condensed again by the cold ambient air to become saturated moist air. Accordingly, this can cause many problems like spoiling landscape around the cooling tower, odor of ambient air, falling accident by frozenness in the winter, and traffic accident, etc. This study was to install the heat exchanger in the inside of the cooling tower in order to prevent the white plume phenomenon in the cooling tower without affecting the performance of cooling tower. In addition, this study was to discharge the part of cooling water into the atmosphere through the recirculation of heat exchanger after creating dry air by heating the saturated moist air to the dew point temperature. At that time, this study was to conduct the experimental study in order to secure the optimal design data to prevent the white plume in the cooling tower because it checked the dry·moist temperature and relative humidity in the inside·outside of cooling tower on the moist air, and evaluated the performance of the heat exchanger.

영상해석을 통한 철도건널목 장애물 검지방법 개선 (Improvement of Obstruction Detecting Method at Railroad Crossing by Image Analyze)

  • 송현삼;김영달;이대동;심재명
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1444-1450
    • /
    • 2011
  • An analysis of the causes of railroad crossing accidents reveals that most train collision accidents that occur when safety crossing devices are functioning normally occur because vehicles either experience engine failure on the tracks or because drivers were not notified of the coming train, in which case they get trapped on the tracks when the crossing barriers descend. To prevent such an accident, obstacle detection device by using laser beams detecting the presence of obstacle and crossing bar direction controller by moving direction detection sensor using the Earth's magnetic field detection technology are used in the railroad crossing. Despite using the obstacles detector and crossing bar direction controller in the railroad crossing, the equipments for the railroad crossing does not prevent accidents completely. Therefore, this research has studied new method that can detect obstacles through image analyze and alternate existing equipments. There will be excellent effect to be preventing railroad crossing accident by developing a reliable and new obstacle detecting device.

전기철도용 소규모SCADA 시스템 설계방안에 관한 연구 (A Study on the Design of Small Unit SCADA System for Electric Railroad)

  • 이승철;신관우;이윤섭
    • 전기학회논문지P
    • /
    • 제53권2호
    • /
    • pp.89-93
    • /
    • 2004
  • Supervisory Control And Data Acquisition(SCADA) of electric power system refersto the system that displays, monitors and executes the control commands for remote electric power system. KNR's existing electric power control system is built on UNIX platform such that it costs more for system construction, and people with UNIX skills can only be an operator who controls and manages the system. Moreover, since the system is mainly operated in local offices, system operators must communicate with local operators to investigate the cause of the accident and react the accident every time the system fails. As a new integrated SCADA system is constructed, establishment of small-unit electric power control system, that alters local electric power control system in designated stations, is required. In this study, the electric power control system, which accommodates all functions of UNIX-based SCADA system and facilitates operation and even maintenance for local operators, is to be developed. In order to develop small-unit electric power control system, the industrial automation program, "Cimon", is used. The small-unit electric power control system that accommodatesRTU and newly installed electronic switchboard is being developed and tested at Chulam station of KNR.

차량형상과 충돌형태에 따른 보행자 거동 특성에 관한 연구 (Pedestrians Trajectory Characteristic for Vehicle Configuration and Pedestrian Postures)

  • 유장석;박경진;장명순
    • 한국자동차공학회논문집
    • /
    • 제13권4호
    • /
    • pp.8-18
    • /
    • 2005
  • Pedestrians involved in traffic accidents manifest unique trajectory characteristics depending on the collision speed, vehicle configuration, and pedestrian postures. However, the existing analytical models for pedestrian movements do not fully include the rotational characteristics of the pedestrians because they assume a two dimensional parabolic trajectory. This faulty assumption in the development of these models limits their applicability and reliability This study investigated the pedestrians movement at collision by computer simulation. The simulations are carried out by using HADYMO, which is a special simulation software system for dynamic movement analysis. Vehicles and pedestrians are modeled and verified via real crash worthiness experiments. Simulations are performed for various collision speeds, vehicle configuration, and pedestrian postures. Since the simulation uses multi-body dynamics, It can express irregular phenomena of the bodies quite well. The results can be exploited for vehicle design and traffic accident reconstruction.